Acta Cryst. (2007). D63, 486-492 [ doi:10.1107/S0907444907005264 ]
Abstract: In experiments conducted at the Bio-CARS beamline 14-BM-C (APS, Argonne National Laboratory, USA), Streptomyces rubiginosus D-xylose isomerase (EC 5.3.1.5) crystals were used to test the effect of cryogen temperature on radiation damage. Crystals cooled using a helium cryostat at an 8 K set temperature consistently showed less decay in the signal-to-noise ratio, <I/
(I)>, and in average intensity, <I>, compared with those cooled with a nitrogen cryostat set to 100 K. Multiple crystals grown using ammonium sulfate as precipitant were used at each cryostat set temperature and comparisons were made for crystals of similar size and diffraction resolution. Maximum resolution for the crystals was 1.1-1.3 Å, with He at <20 K extending the lifetime of the high-resolution data by >25% compared with crystals cooled with N2 at 100 K.
Keywords: cryocrystallography; radiation damage; helium.
![]() ![]() Portable Document Format (PDF) file (213.4 kbytes) | |
To open or display or play some files, you may need to set your browser up to use the appropriate software. See the full list of file types for an explanation of the different file types and their related mime types and, where available links to sites from where the appropriate software may be obtained.