Acta Cryst. (2001). E57, m576-m577 [ doi:10.1107/S1600536801018712 ]
Online 10 November 2001
No syntax errors found
ADDSYM reports no extra symmetryAlert Level A:
THETM_01 Alert A The value of sine(theta_max)/wavelength is less than 0.550 Calculated sin(theta_max)/wavelength = 0.5421
| Author response: The calculated sin(theta_max)/wavelength is 0.5424. That value is because our four circle diffractometer, Bruker P4, has a problem and it is not posible to increase the 2theta angle more than 113.5 degrees. But the calculated sin(theta_max)/wavelength is very close to the limit 0.550 |
General Notes
ABSTM_02 When printed, the submitted absorption T values will be replaced by the scaled T values. Since the ratio of scaled T's is identical to the ratio of reported T values, the scaling does not imply a change to the absorption corrections used in the study. Ratio of Tmax expected/reported 0.289 Tmax scaled 0.225 Tmin scaled 0.099
1 Alert Level A = Potentially serious problem
0 Alert Level B = Potential problem
0 Alert Level C = Please check
Copyright © International Union of Crystallography