Acta Cryst. (2004). E60, m685-m686 [ doi:10.1107/S1600536804009663 ]
Online 30 April 2004
No syntax errors found
Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR') is < 0.90 Tmin and Tmax reported: 0.620 0.898 Tmin' and Tmax expected: 0.821 0.898 RR' = 0.755 Please check that your absorption correction is appropriate. PLAT061_ALERT_3_C Tmax/Tmin Range Test RR' too Large ............. 0.75 PLAT125_ALERT_4_C No _symmetry_space_group_name_Hall Given ....... ? PLAT341_ALERT_3_C Low Bond Precision on C-C bonds (x 1000) Ang ... 8 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 5 N1 -NI1 -O2 -C14 99.90 1.50 1.555 1.555 1.555 1.555
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 5 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 0 ALERT type 2 Indicator that the structure model may be wrong or deficient 3 ALERT type 3 Indicator that the structure quality may be low 2 ALERT type 4 Improvement, methodology, query or suggestion