[HTML version][PDF version][Article Abstract][CIF][3d view][Structure Factors][Issue contents]  [Buy article online]

Acta Cryst. (2006). E62, i122-i123  [ doi:10.1107/S1600536806013328 ]

Pentaaquahydroxoscandium(III) dibromide, [Sc(H2O)5(OH)]Br2

U. Kolitsch

Online 21 April 2006


Key indicators

checkCIF/PLATON results

No syntax errors found




Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR) is > 1.10 Tmin and Tmax reported: 0.301 0.457 Tmin and Tmax expected: 0.221 0.395 RR = 1.179 Please check that your absorption correction is appropriate. PLAT041_ALERT_1_C Calc. and Rep. SumFormula Strings Differ .... ? PLAT045_ALERT_1_C Calculated and Reported Z Differ by ............ 0.50 Ratio PLAT060_ALERT_3_C Ratio Tmax/Tmin (Exp-to-Rep) (too) Large ....... 1.16 PLAT062_ALERT_4_C Rescale T(min) & T(max) by ..................... 0.86 PLAT199_ALERT_1_C Check the Reported _cell_measurement_temperature 293 K PLAT200_ALERT_1_C Check the Reported _diffrn_ambient_temperature . 293 K PLAT232_ALERT_2_C Hirshfeld Test Diff (M-X) Sc - O6 .. 5.19 su PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for Sc PLAT250_ALERT_2_C Large U3/U1 Ratio for Average U(i,j) Tensor .... 2.53 PLAT731_ALERT_1_C Bond Calc 0.87(4), Rep 0.866(18) ...... 2.22 su-Rat O2 -H2 1.555 1.555 PLAT731_ALERT_1_C Bond Calc 0.88(4), Rep 0.883(18) ...... 2.22 su-Rat O4 -H7 1.555 1.555 PLAT731_ALERT_1_C Bond Calc 0.86(4), Rep 0.859(19) ...... 2.11 su-Rat O5 -H9 1.555 1.555 PLAT731_ALERT_1_C Bond Calc 0.87(4), Rep 0.871(19) ...... 2.11 su-Rat O6 -H11 1.555 1.555 PLAT735_ALERT_1_C D-H Calc 0.87(4), Rep 0.866(18) ...... 2.22 su-Rat O2 -H2 1.555 1.555 PLAT735_ALERT_1_C D-H Calc 0.88(4), Rep 0.883(18) ...... 2.22 su-Rat O4 -H7 1.555 1.555 PLAT735_ALERT_1_C D-H Calc 0.86(4), Rep 0.859(19) ...... 2.11 su-Rat O5 -H9 1.555 1.555 PLAT735_ALERT_1_C D-H Calc 0.87(4), Rep 0.871(19) ...... 2.11 su-Rat O6 -H11 1.555 1.555 PLAT736_ALERT_1_C H...A Calc 2.40(4), Rep 2.401(19) ...... 2.11 su-Rat H7 -BR2 1.555 2.656
Alert level G ABSTM02_ALERT_3_G When printed, the submitted absorption T values will be replaced by the scaled T values. Since the ratio of scaled T's is identical to the ratio of reported T values, the scaling does not imply a change to the absorption corrections used in the study. Ratio of Tmax expected/reported 0.864 Tmax scaled 0.395 Tmin scaled 0.260
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 19 ALERT level C = Check and explain 1 ALERT level G = General alerts; check 13 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 3 ALERT type 2 Indicator that the structure model may be wrong or deficient 3 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion

Copyright © International Union of Crystallography
IUCr Webmaster