[HTML version][PDF version][Article Abstract][CIF][3d view][Structure Factors][Issue contents]  [Buy article online]

[Contents scheme]

Acta Cryst. (2006). E62, m2987-m2989  [ doi:10.1107/S1600536806041997 ]

Di-[mu]-iodo-bis[diiodo(1,10-phenanthroline)bismuth(III)]

M. A. Tershansy, A. M. Goforth, M. D. Smith, L. R. Peterson Jr and H.-C. zur Loye

Online 25 October 2006


Key indicators

checkCIF/PLATON results

No syntax errors found




Alert level B PLAT232_ALERT_2_B Hirshfeld Test Diff (M-X) Bi1 - I3 .. 12.63 su PLAT232_ALERT_2_B Hirshfeld Test Diff (M-X) Bi1 - I3_a .. 17.23 su
Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR) is > 1.10 Tmin and Tmax reported: 0.133 0.200 Tmin and Tmax expected: 0.110 0.197 RR = 1.188 Please check that your absorption correction is appropriate. PLAT060_ALERT_3_C Ratio Tmax/Tmin (Exp-to-Rep) (too) Large ....... 1.18 PLAT232_ALERT_2_C Hirshfeld Test Diff (M-X) Bi1 - I2 .. 8.64 su
0 ALERT level A = In general: serious problem 2 ALERT level B = Potentially serious problem 3 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 3 ALERT type 2 Indicator that the structure model may be wrong or deficient 2 ALERT type 3 Indicator that the structure quality may be low 0 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

Copyright © International Union of Crystallography
IUCr Webmaster