[HTML version][PDF version][Article Abstract][CIF][3d view][Structure Factors][Issue contents]  [Buy article online]

[Contents scheme]

Acta Cryst. (2006). E62, o4899-o4901  [ doi:10.1107/S1600536806041067 ]

3-Bromo-5-tert-butyl-2-(4-isopropylphenyl)-2-methoxycyclohexan-1-one oxime

M. Periasamy, L. Anjana, S. Athimoolam, A. Ponnuswamy and S. Natarajan

Online 11 October 2006


Key indicators

checkCIF/PLATON results

No syntax errors found




Alert level B PLAT220_ALERT_2_B Large Non-Solvent C Ueq(max)/Ueq(min) ... 4.20 Ratio PLAT222_ALERT_3_B Large Non-Solvent H Ueq(max)/Ueq(min) ... 4.17 Ratio PLAT242_ALERT_2_B Check Low Ueq as Compared to Neighbors for C17
Alert level C PLAT026_ALERT_3_C Ratio Observed / Unique Reflections too Low .... 47 Perc. PLAT062_ALERT_4_C Rescale T(min) & T(max) by ..................... 0.78 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for C9 PLAT250_ALERT_2_C Large U3/U1 Ratio for Average U(i,j) Tensor .... 2.23 PLAT301_ALERT_3_C Main Residue Disorder ......................... 4.00 Perc. PLAT341_ALERT_3_C Low Bond Precision on C-C bonds (x 1000) Ang ... 8 PLAT480_ALERT_4_C Long H...A H-Bond Reported H11 .. O2 .. 2.72 Ang. PLAT779_ALERT_2_C Suspect or Irrelevant (Bond) Angle in CIF ...... 33.60 Deg. C152 -C13 -C15 1.555 1.555 1.555 PLAT779_ALERT_2_C Suspect or Irrelevant (Bond) Angle in CIF ...... 18.40 Deg. C152 -C13 -H131 1.555 1.555 1.555 PLAT779_ALERT_2_C Suspect or Irrelevant (Bond) Angle in CIF ...... 31.10 Deg. C151 -C13 -H132 1.555 1.555 1.555 PLAT779_ALERT_2_C Suspect or Irrelevant (Bond) Angle in CIF ...... 22.70 Deg. H13 -C13 -H132 1.555 1.555 1.555 PLAT779_ALERT_2_C Suspect or Irrelevant (Bond) Angle in CIF ...... 40.40 Deg. C13 -C15 -H131 1.555 1.555 1.555 PLAT779_ALERT_2_C Suspect or Irrelevant (Bond) Angle in CIF ...... 37.60 Deg. C13 -C151 -H132 1.555 1.555 1.555 PLAT779_ALERT_2_C Suspect or Irrelevant (Bond) Angle in CIF ...... 28.70 Deg. C13 -C152 -H131 1.555 1.555 1.555
Alert level G ABSTM02_ALERT_3_G When printed, the submitted absorption T values will be replaced by the scaled T values. Since the ratio of scaled T's is identical to the ratio of reported T values, the scaling does not imply a change to the absorption corrections used in the study. Ratio of Tmax expected/reported 0.780 Tmax scaled 0.776 Tmin scaled 0.756 PLAT199_ALERT_1_G Check the Reported _cell_measurement_temperature 293 K PLAT200_ALERT_1_G Check the Reported _diffrn_ambient_temperature . 293 K
0 ALERT level A = In general: serious problem 3 ALERT level B = Potentially serious problem 14 ALERT level C = Check and explain 3 ALERT level G = General alerts; check 2 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 11 ALERT type 2 Indicator that the structure model may be wrong or deficient 5 ALERT type 3 Indicator that the structure quality may be low 2 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

Copyright © International Union of Crystallography
IUCr Webmaster