[HTML version][PDF version][Article Abstract][CIF][3d view][Structure Factors][Issue contents]  [Buy article online]

[Contents scheme]

Acta Cryst. (2006). E62, m2855-m2857  [ doi:10.1107/S1600536806040670 ]

(6-Mercaptopurinato)(tricyclohexylphosphine)gold(I) ethanol solvate

S. Y. Ho and E. R. T. Tiekink

Online 11 October 2006


Key indicators

checkCIF/PLATON results

No syntax errors found



Alert level A PLAT223_ALERT_4_A Large Solvent/Anion H Ueq(max)/Ueq(min) ... 5.33 Ratio
Author Response: Owing to the disorder evident in this group, attempts were made to locate multiple sites. However, these attempts were unsuccessful suggesting that the disorder is dynamic in nature.

Alert level C PLAT062_ALERT_4_C Rescale T(min) & T(max) by ..................... 0.76 PLAT244_ALERT_4_C Low 'Solvent' Ueq as Compared to Neighbors for C41 PLAT360_ALERT_2_C Short C(sp3)-C(sp3) Bond C41 - C42 ... 1.42 Ang. PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 1 P1 -AU -S6 -C6 -120.80 0.70 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 2 S6 -AU -P1 -C11 -35.60 0.80 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 3 S6 -AU -P1 -C31 86.50 0.80 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 4 S6 -AU -P1 -C21 -156.10 0.70 1.555 1.555 1.555 1.555
Alert level G ABSTM02_ALERT_3_G When printed, the submitted absorption T values will be replaced by the scaled T values. Since the ratio of scaled T's is identical to the ratio of reported T values, the scaling does not imply a change to the absorption corrections used in the study. Ratio of Tmax expected/reported 0.757 Tmax scaled 0.757 Tmin scaled 0.298
1 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 7 ALERT level C = Check and explain 1 ALERT level G = General alerts; check 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 1 ALERT type 2 Indicator that the structure model may be wrong or deficient 1 ALERT type 3 Indicator that the structure quality may be low 7 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

Copyright © International Union of Crystallography