[HTML version][PDF version][Article Abstract][CIF][3d view][Structure Factors][Issue contents]  [Buy article online]

Acta Cryst. (2006). E62, i269-i271  [ doi:10.1107/S1600536806049063 ]

Europium(III) sulfate hydroxide

S.-H. Ding, X.-C. Sun, Y.-L. Zhu, Q. Chen and Y. Xu

Online 24 November 2006


Key indicators

checkCIF/PLATON results

No syntax errors found




Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR) is > 1.10 Tmin and Tmax reported: 0.291 0.408 Tmin and Tmax expected: 0.213 0.335 RR = 1.122 Please check that your absorption correction is appropriate. PLAT060_ALERT_3_C Ratio Tmax/Tmin (Exp-to-Rep) (too) Large ....... 1.13 PLAT062_ALERT_4_C Rescale T(min) & T(max) by ..................... 0.82 PLAT779_ALERT_2_C Suspect or Irrelevant (Bond) Angle in CIF ...... 37.58 Deg. O2 -S1 -EU1 1.555 1.555 3.665
Alert level G ABSTM02_ALERT_3_G When printed, the submitted absorption T values will be replaced by the scaled T values. Since the ratio of scaled T's is identical to the ratio of reported T values, the scaling does not imply a change to the absorption corrections used in the study. Ratio of Tmax expected/reported 0.822 Tmax scaled 0.335 Tmin scaled 0.239 PLAT199_ALERT_1_G Check the Reported _cell_measurement_temperature 293 K PLAT200_ALERT_1_G Check the Reported _diffrn_ambient_temperature . 293 K
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 4 ALERT level C = Check and explain 3 ALERT level G = General alerts; check 2 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 1 ALERT type 2 Indicator that the structure model may be wrong or deficient 3 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

Copyright © International Union of Crystallography
IUCr Webmaster