[HTML version][PDF version][Article Abstract][CIF][3d view][Structure Factors][Issue contents]  [Buy article online]

[Contents scheme]

Acta Cryst. (2006). E62, m3425-m3428  [ doi:10.1107/S1600536806047386 ]

A structure with trigonally and tetrahedrally coordinated CuI cations: rac-(acetonitrile)[2,2'-bis(1-propyl-1H-benzimidazol-2-yl)biphenyl]copper(I) bis(acetonitrile)[2,2'-bis(1-propyl-1H-benzimidazol-2-yl)biphenyl]copper(I) bis(perchlorate)

R. T. Stibrany and J. A. Potenza

Online 24 November 2006


Key indicators

checkCIF/PLATON results

No syntax errors found




Alert level B PLAT220_ALERT_2_B Large Non-Solvent C Ueq(max)/Ueq(min) ... 4.24 Ratio PLAT221_ALERT_4_B Large Solvent/Anion O Ueq(max)/Ueq(min) ... 4.03 Ratio PLAT222_ALERT_3_B Large Non-Solvent H Ueq(max)/Ueq(min) ... 4.52 Ratio
Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR) is > 1.10 Tmin and Tmax reported: 0.867 1.000 Tmin and Tmax expected: 0.720 0.947 RR = 1.140 Please check that your absorption correction is appropriate. PLAT042_ALERT_1_C Calc. and Rep. MoietyFormula Strings Differ .... ? PLAT060_ALERT_3_C Ratio Tmax/Tmin (Exp-to-Rep) (too) Large ....... 1.14 PLAT062_ALERT_4_C Rescale T(min) & T(max) by ..................... 0.95 PLAT220_ALERT_2_C Large Non-Solvent C Ueq(max)/Ueq(min) ... 3.13 Ratio PLAT220_ALERT_2_C Large Non-Solvent N Ueq(max)/Ueq(min) ... 2.89 Ratio PLAT222_ALERT_3_C Large Non-Solvent H Ueq(max)/Ueq(min) ... 3.23 Ratio PLAT232_ALERT_2_C Hirshfeld Test Diff (M-X) Cu1 - N52 .. 5.53 su PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for N51 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for N52 PLAT601_ALERT_2_C Structure Contains Solvent Accessible VOIDS of . 47.00 A   3 PLAT720_ALERT_4_C Number of Unusual/Non-Standard Label(s) ........ 12
Alert level G ABSTM02_ALERT_3_G When printed, the submitted absorption T values will be replaced by the scaled T values. Since the ratio of scaled T's is identical to the ratio of reported T values, the scaling does not imply a change to the absorption corrections used in the study. Ratio of Tmax expected/reported 0.947 Tmax scaled 0.947 Tmin scaled 0.821
0 ALERT level A = In general: serious problem 3 ALERT level B = Potentially serious problem 12 ALERT level C = Check and explain 1 ALERT level G = General alerts; check 1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 7 ALERT type 2 Indicator that the structure model may be wrong or deficient 5 ALERT type 3 Indicator that the structure quality may be low 3 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

Copyright © International Union of Crystallography
IUCr Webmaster