![[HTML version]](/e/graphics/htmlborder.gif)
![[PDF version]](/e/graphics/pdfborder.gif)
![[Article Abstract]](/e/graphics/abstractborder.gif)
![[CIF]](/e/graphics/cifborder.gif)
![[3d view]](/e/graphics/3dviewborder.gif)
![[Structure Factors]](/e/graphics/structurefactorsborder.gif)
![[Buy article online]](/logos/buy.gif)
![[Contents scheme]](wn2125contents.gif)
Acta Cryst. (2007). E63, o2821-o2823 [ doi:10.1107/S1600536807018429 ]
Online 5 May 2007
No syntax errors found
Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR') is < 0.90 Tmin and Tmax reported: 0.644 0.929 Tmin(prime) and Tmax expected: 0.777 0.929 RR(prime) = 0.829 Please check that your absorption correction is appropriate. PLAT029_ALERT_3_C _diffrn_measured_fraction_theta_full Low ....... 0.97 PLAT061_ALERT_3_C Tmax/Tmin Range Test RR' too Large ............. 0.82 PLAT125_ALERT_4_C No _symmetry_space_group_name_Hall Given ....... ? PLAT154_ALERT_1_C The su's on the Cell Angles are Equal (x 10000) 300 Deg.
Alert level G PLAT199_ALERT_1_G Check the Reported _cell_measurement_temperature 293 K PLAT200_ALERT_1_G Check the Reported _diffrn_ambient_temperature . 293 K
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 5 ALERT level C = Check and explain 2 ALERT level G = General alerts; check 3 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 0 ALERT type 2 Indicator that the structure model may be wrong or deficient 3 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check
Copyright © International Union of Crystallography
IUCr Webmaster