[HTML version][PDF version] [Open access]

[Contents scheme]

Acta Cryst. (2008). E64, m464-m465  [ doi:10.1107/S1600536808003528 ]

trans-Carbonylchloridobis(tri-p-tolylphosphine)rhodium(I) acetone solvate

F. Lorenzini, B. O. Patrick and B. R. James

Online 8 February 2008


Key indicators

checkCIF/PLATON results

No syntax errors found




Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR') is < 0.90 Tmin and Tmax reported: 0.683 0.960 Tmin(prime) and Tmax expected: 0.864 0.960 RR(prime) = 0.791 Please check that your absorption correction is appropriate. PLAT061_ALERT_3_C Tmax/Tmin Range Test RR' too Large ............. 0.79 PLAT220_ALERT_2_C Large Non-Solvent C Ueq(max)/Ueq(min) ... 2.85 Ratio PLAT222_ALERT_3_C Large Non-Solvent H Ueq(max)/Ueq(min) ... 3.02 Ratio PLAT232_ALERT_2_C Hirshfeld Test Diff (M-X) Rh1 - C43 .. 7.14 su PLAT244_ALERT_4_C Low 'Solvent' Ueq as Compared to Neighbors for C44
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 6 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 2 ALERT type 2 Indicator that the structure model may be wrong or deficient 3 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

Copyright © International Union of Crystallography
IUCr Webmaster