[HTML version][PDF version][Article Abstract][CIF][3d view][Structure Factors][Supplementary Material][Issue contents]  [Open access]

[Contents scheme]

Acta Cryst. (2008). E64, m784  [ doi:10.1107/S1600536808012609 ]

catena-Poly[[bis[1-phenyl-3-(1H-1,2,4-triazol-1-yl)propan-1-one-[kappa]N4]cadmium(II)]-di-[mu]-azido-[kappa]4N1:N3]

Y. Guo, H. Cai, J. Li and G. Wan

Online 7 May 2008


Key indicators

checkCIF/PLATON results

No syntax errors found




Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR') is < 0.90 Tmin and Tmax reported: 0.760 1.000 Tmin(prime) and Tmax expected: 0.800 0.881 RR(prime) = 0.838 Please check that your absorption correction is appropriate. PLAT061_ALERT_3_C Tmax/Tmin Range Test RR' too Large ............. 0.83 PLAT062_ALERT_4_C Rescale T(min) & T(max) by ..................... 0.88 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for N15 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for N18 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for N19 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for N21 PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for Cd1 PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for N14 PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for N20 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 2 N24 -CD1 -N1 -C1 -47.70 0.80 1.455 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 7 N24 -CD1 -N1 -C2 127.00 0.70 1.455 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 13 N19 -CD1 -N4 -C13 15.40 1.20 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 18 N19 -CD1 -N4 -C12 -137.30 1.00 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 25 N13 -CD2 -N7 -C24 -2.90 1.20 1.655 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 30 N13 -CD2 -N7 -C23 147.60 0.90 1.655 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 39 N18 -CD2 -N10 -C34 50.30 1.00 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 44 N18 -CD2 -N10 -C35 -126.00 0.80 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 49 CD2 -N13 -N14 -N15 173.00 4.00 1.455 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 50 N13 -N14 -N15 -CD1 149.00 4.00 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 55 N16 -CD1 -N15 -N14 125.50 0.60 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 59 N15 -CD1 -N16 -N17 108.50 0.60 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 61 CD1 -N16 -N17 -N18 -116.00 12.00 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 62 N16 -N17 -N18 -CD2 -161.00 11.00 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 66 N10 -CD2 -N18 -N17 -83.50 0.90 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 71 N4 -CD1 -N19 -N20 -66.10 1.20 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 73 CD1 -N19 -N20 -N21 18.00 0.00 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 74 N19 -N20 -N21 -CD2 -145.00 5.00 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 79 N22 -CD2 -N21 -N20 -119.00 0.60 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 81 N21 -CD2 -N22 -N23 -111.20 0.60 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 85 CD2 -N22 -N23 -N24 115.00 14.00 1.555 1.555 1.555 1.555 PLAT710_ALERT_4_C Delete 1-2-3 or 2-3-4 Linear Torsion Angle ... # 86 N22 -N23 -N24 -CD1 16.00 0.00 1.555 1.555 1.555 1.655
Alert level G ABSTM02_ALERT_3_G When printed, the submitted absorption T values will be replaced by the scaled T values. Since the ratio of scaled T's is identical to the ratio of reported T values, the scaling does not imply a change to the absorption corrections used in the study. Ratio of Tmax expected/reported 0.881 Tmax scaled 0.881 Tmin scaled 0.670
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 32 ALERT level C = Check and explain 1 ALERT level G = General alerts; check 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 7 ALERT type 2 Indicator that the structure model may be wrong or deficient 3 ALERT type 3 Indicator that the structure quality may be low 23 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

Copyright © International Union of Crystallography
IUCr Webmaster