[HTML version][PDF version][Article Abstract][CIF][3d view][Structure Factors][Supplementary Material][Issue contents]  [Open access]

Acta Cryst. (2009). E65, i1  [ doi:10.1107/S1600536808041585 ]

Nb1.30Cr0.70S5: a layered ternary mixed-metal sulfide

H. Yun and G. Kim

Online 13 December 2008


Key indicators

checkCIF/PLATON results

No syntax errors found




Alert level C Value of measurement temperature given = 150.000 Value of melting point given = 0.000 PLAT301_ALERT_3_C Main Residue Disorder ......................... 6.00 Perc. PLAT041_ALERT_1_C Calc. and Rep. SumFormula Strings Differ .... ? PLAT045_ALERT_1_C Calculated and Reported Z Differ by ............ 0.50 Ratio PLAT068_ALERT_1_C Reported F000 Differs from Calcd (or Missing)... ? PLAT077_ALERT_4_C Unitcell contains non-integer number of atoms .. ? PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M M S2 PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M M S5 PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M M S5 PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M M S2 PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M M S2 PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M M S1 PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M M M PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M M M PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M S2 M PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M S5 M PLAT711_ALERT_1_C BOND Unknown or Inconsistent Label .......... M S5 M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M S5 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M S5 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M S5 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M S2 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M S2 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M S2 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M S2 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M S2 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M S2 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M S2 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M S1 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M S1 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M S1 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M S1 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M S1 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S1 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S5 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S2 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M S1 M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M M M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M S1 NB1 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M S1 NB1 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M S1 NB1 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M S2 M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M S2 M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M S2 M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M S5 M PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M S5 NB1 PLAT712_ALERT_1_C ANGLE Unknown or Inconsistent Label .......... M M S5 NB1
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 53 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 51 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 0 ALERT type 2 Indicator that the structure model may be wrong or deficient 1 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check

Copyright © International Union of Crystallography
IUCr Webmaster