![[HTML version]](/e/graphics/htmlborder.gif)
![[Open access]](/e/graphics/free.gif)
Acta Cryst. (2009). E65, i18-i19 [ doi:10.1107/S1600536809005601 ]
Online 21 February 2009
No syntax errors found
Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR) is > 1.10 Tmin and Tmax reported: 0.060 0.224 Tmin and Tmax expected: 0.053 0.218 RR = 1.104 Please check that your absorption correction is appropriate. Value of measurement temperature given = 123.000 Value of melting point given = 0.000 PLAT060_ALERT_4_C Ratio Tmax/Tmin (Exp-to-Rep) (too) Large ....... 1.14 PLAT154_ALERT_1_C The su's on the Cell Angles are Equal (x 10000) 100 Deg. PLAT482_ALERT_4_C Small D-H..A Angle Rep for O42 .. O21 .. 94.00 Deg. PLAT790_ALERT_4_C Centre of Gravity not Within Unit Cell: Resd. # 3 K PLAT790_ALERT_4_C Centre of Gravity not Within Unit Cell: Resd. # 4 K
Alert level G PLAT860_ALERT_3_G Note: Number of Least-Squares Restraints ....... 10 PLAT180_ALERT_4_G Check Cell Rounding: # of Values Ending with 0 = 3
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 6 ALERT level C = Check and explain 2 ALERT level G = General alerts; check 1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 0 ALERT type 2 Indicator that the structure model may be wrong or deficient 2 ALERT type 3 Indicator that the structure quality may be low 5 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check
Copyright © International Union of Crystallography
IUCr Webmaster