Journal of Synchrotron Radiation

Volume 16, Part 1 (January 2009)



[Issue Author Index][Volume Author Index]
[Cover illustration] Cover illustration: Multi-modal X-ray images of bee, moth and lavender flower with three contrast mechanisms: attenuation contrast, differential phase contrast and dark-field contrast (see Bech, Bunk, David, Ruth, Rifkin, Loewen, Feidenhans'l and Pfeiffer, pages 43-47). Images are recorded at the Compact Light Source, an X-ray source based on inverse Compton scattering, the first of its kind. Phase contrast and dark-field images are obtained with a grating interferometer.

research papers


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 1-7  [ doi:10.1107/S0909049508028872 ]

Dynamic performance of the beam position monitor support at the SSRF

X. Wang, Y. Cao, H. Du and L. Yin

Synopsis: The dynamic performance of the beam position monitor support at the Shanghai Synchrotron Radiation Facility is studied by finite-element analysis and vibration measurements. The mechanical stability of the support is improved by changing the connections between the support and the ground.

Online 21 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 8-13  [ doi:10.1107/S0909049508033736 ]

Diamond kinoform hard X-ray refractive lenses: design, nanofabrication and testing

A. F. Isakovic, A. Stein, J. B. Warren, S. Narayanan, M. Sprung, A. R. Sandy and K. Evans-Lutterodt

Synopsis: Numerical design and nanofabrication procedures for the production of diamond-based kinoform refractive X-ray lenses are discussed; a test of a focusing action of a single lens is presented.

Online 21 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 14-21  [ doi:10.1107/S0909049508031105 ]

Upgrade of the CATS sample changer on FIP-BM30A at the ESRF: towards a commercialized standard

L. Jacquamet, J. Joly, A. Bertoni, P. Charrault, M. Pirocchi, X. Vernede, F. Bouis, F. Borel, J.-P. Périn, T. Denis, J.-L. Rechatin and J.-L. Ferrer

Synopsis: An upgraded version of the sample changer CATS (Cryogenic Automated Transfer System) has been developed on the FIP-BM30A beamline at the ESRF. This system has the ability to manage any sample standard stored in any kind of puck

Online 14 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 22-29  [ doi:10.1107/S0909049508034663 ]

A combined microRaman and microdiffraction set-up at the European Synchrotron Radiation Facility ID13 beamline

R. J. Davies, M. Burghammer and C. Riekel

Synopsis: An overview of the combined microRaman/microdiffraction set-up at the European Synchrotron Radiation Facility's microfocus beamline, including typical beamline application examples, is given.

Online 21 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 30-37  [ doi:10.1107/S0909049508030628 ]

Correlation between local vibrations and metal mass in AlB2-type transition-metal diborides

W. S. Chu, S. Zhang, M. J. Yu, L. R. Zheng, T. D. Hu, H. F. Zhao, A. Marcelli, A. Bianconi, N. L. Saini, W. H. Liu and Z. Y. Wu

Synopsis: Lattice vibrations have been investigated in TiB2, ZrB2 and HfB2 by temperature-dependent EXAFS experiments. Data clearly show that the EXAFS oscillations are characterized by an anomalous behavior of the Debye-Waller factor of the transition-metal-boron pair.

Online 14 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 38-42  [ doi:10.1107/S0909049508033931 ]

Temperature dependence of the Ho L2-edge XMCD spectra of Ho6Fe23

R. Boada, M. Á. Laguna-Marco and J. Chaboy

Synopsis: An X-ray magnetic circular dichroism study performed at the Ho L2,3-edges in Ho6Fe23 as a function of temperature is presented.

Online 14 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 43-47  [ doi:10.1107/S090904950803464X ]

Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays

M. Bech, O. Bunk, C. David, R. Ruth, J. Rifkin, R. Loewen, R. Feidenhans'l and F. Pfeiffer

Synopsis: First X-ray phase-contrast imaging results recorded at the Compact Light Source, a laboratory-based inverse Compton X-ray source, are reported.

Online 27 November 2008


[HTML version][PDF version][CIF][3d view]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 48-56  [ doi:10.1107/S0909049508036029 ]

Pressure study of monoclinic ReO2 up to 1.2 GPa using X-ray absorption spectroscopy and X-ray diffraction

F. F. Ferreira, H. P. S. Corrêa, M. T. D. Orlando, J. L. Passamai, C. G. P. Orlando, I. P. Cavalcante, F. Garcia, E. Tamura, L. G. Martinez, J. L. Rossi and F. C. L. de Melo

Synopsis: A pressure study of the [alpha]-ReO2 structure up to 1.2 GPa using synchrotron X-ray powder diffraction and X-ray absorption spectroscopy is reported for the first time. To study the [alpha]-ReO2 phase under hydrostatic pressure, a new boron carbide anvil pressure cell that can be used in absorption and diffraction X-ray experiments in any synchrotron radiation facility has been developed and built.

Online 27 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 57-62  [ doi:10.1107/S0909049508031853 ]

X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in mice

T. Takeda, J. Wu, Thet-Thet-Lwin, Q. Huo, T. Yuasa, K. Hyodo, F. A. Dilmanian and T. Akatsuka

Synopsis: Using X-ray fluorescent computed tomography (XFCT), the in vivo and ex vivo cerebral distribution of a stable-iodine-labeled cerebral perfusion agent has been recorded in the brains of mice. Results highlight the sensitivity of XFCT and its considerable potential to evaluate cerebral perfusion in small animals without using radioactive agents.

Online 21 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 63-68  [ doi:10.1107/S0909049508032433 ]

First XANES evidence of a disorder-order transition in a spinel ferrite compound: nanocrystalline ZnFe2O4

S. J. A. Figueroa and S. J. Stewart

Synopsis: In situ XANES experiments were performed to investigate the disorder to order transition in nano-sized zinc ferrite.

Online 14 November 2008


[HTML version][PDF version][Supplementary Material]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 69-75  [ doi:10.1107/S0909049508034870 ]

The MX2 macromolecular crystallography beamline: a wiggler X-ray source at the LNLS

B. G. Guimarães, L. Sanfelici, R. T. Neuenschwander, F. Rodrigues, W. C. Grizolli, M. A. Raulik, J. R. Piton, B. C. Meyer, A. S. Nascimento and I. Polikarpov

Synopsis: The Brazilian Synchrotron Light Laboratory is the only synchrotron radiation source in Latin America. Here the design, technical set-up and experimental parameters of the first wiggler macromolecular crystallography beamline (MX2) at this synchrotron source are described. Parameters of the X-ray diffraction data sets collected at the MX2 are also provided.

Online 27 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 76-82  [ doi:10.1107/S0909049508039782 ]

High-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam

R. A. Barrea, R. Huang, S. Cornaby, D. H. Bilderback and T. C. Irving

Synopsis: A pre-focused X-ray beam has been used to illuminate a single-bounce capillary in order to generate a high-flux X-ray microbeam at the BioCAT undulator X-ray beamline at the Advanced Photon Source. The combined optical arrangement makes it suitable for many microprobe fluorescence applications and micro-XANES experiments for biological samples.

Online 18 December 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 83-96  [ doi:10.1107/S0909049508030859 ]

Selected techniques in diamond anvil cell crystallography: centring samples using X-ray transmission and rocking powder samples to improve X-ray diffraction image quality

J. S. Smith and S. Desgreniers

Synopsis: A method for positioning diamond anvil cell samples at a centre of rotation is described and evaluated, after which the practice of rocking properly centred polycrystalline samples is examined. These selected techniques are crucial to optimizing the quality of data, and hence the accuracy of structural parameters, obtained from microscopic samples submitted to extreme pressure conditions.

Online 14 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 97-104  [ doi:10.1107/S0909049508034134 ]

A dedicated small-angle X-ray scattering beamline with a superconducting wiggler source at the NSRRC

D.-G. Liu, C.-H. Chang, C.-Y. Liu, S.-H. Chang, J.-M. Juang, Y.-F. Song, K.-L. Yu, K.-F. Liao, C.-S. Hwang, H.-S. Fung, P.-C. Tseng, C.-Y. Huang, L.-J. Huang, S.-C. Chung, M.-T. Tang, K.-L. Tsang, Y.-S. Huang, C.-K. Kuan, Y.-C. Liu, K. S. Liang and U.-S. Jeng

Synopsis: A dedicated SAXS beamline with a superconducting wiggler source has been installed at the NSRRC to provide a low-divergence beam of 1010-1011 photons s-1 in the energy range 5-23 keV for nanostructural research.

Online 14 November 2008


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 105-109  [ doi:10.1107/S0909049508034365 ]

A Geiger-mode avalanche photodiode array for X-ray photon correlation spectroscopy

I. Johnson, Z. Sadygov, O. Bunk, A. Menzel, F. Pfeiffer and D. Renker

Synopsis: A Geiger-mode avalanche photodiode array for X-ray photon correlation spectroscopy is presented.

Online 21 November 2008


[HTML version][PDF version]  [Open access]

J. Synchrotron Rad. (2009). 16, 110-115  [ doi:10.1107/S0909049508034596 ]

Capturing molecular structural dynamics by 100 ps time-resolved X-ray absorption spectroscopy

T. Sato, S. Nozawa, K. Ichiyanagi, A. Tomita, M. Chollet, H. Ichikawa, H. Fujii, S. Adachi and S.- Koshihara

Synopsis: An experimental set-up for time-resolved X-ray absorption spectroscopy with 100 ps time resolution at beamline NW14A at the Photon Factory Advanced Ring is presented.

Online 21 November 2008


short communications


[HTML version][PDF version]  [Buy article online]

J. Synchrotron Rad. (2009). 16, 116-118  [ doi:10.1107/S0909049508039289 ]

Focusing synchrotron radiation using a polycapillary half-focusing X-ray lens for imaging

T. Sun, M. Zhang, Z. Liu, Z. Zhang, G. Li, Y. Ma, X. Du, Q. Jia, Y. Chen, Q. Yuan, W. Huang, P. Zhu and X. Ding

Synopsis: An imaging system based on a polycapillary half-focusing X-ray lens and synchrotron radiation source has been designed.

Online 18 December 2008


current events


[HTML version][PDF version]  [Open access]

J. Synchrotron Rad. (2009). 16, 119-121  [ doi:10.1107/S090904950804199X ]

Current events

Online 18 December 2008


international union of crystallography


[HTML version][PDF version]  [Open access]

J. Synchrotron Rad. (2009). 16, 122-126  [ doi:10.1107/S0909049508038223 ]

Notes for authors 2009

Online 18 December 2008


J. Synchrotron Rad.. (2009). 16, 127

forthcoming meetings and short courses.


Copyright © International Union of Crystallography
IUCr Webmaster