research papers
We investigated the position and time dependence of a mechanochemical reaction induced by ball milling using in situ synchrotron powder X-ray diffraction with changing X-ray irradiation position. The mechanochemical reduction of AgCl with Cu was monitored in situ with the X-rays incident at two different vertical positions on the jar. Our previously developed multi-distance Rietveld method was applied to analyze the in situ diffraction data with a 1 min resolution. Both the vertical and the horizontal sample positions were determined using the sample-to-detector distances from the in situ data. Position dependence was found in the powder spreading and induction time. We reveal that the increase rate of the product is independent of the sample position when measured with a 1 min time resolution, confirming the validity of in situ monitoring of part of the space in a milling jar for a gradual mechanochemical reaction.
Keywords: in situ powder X-ray diffraction; ball milling; mechanochemical reactions; position-resolved monitoring; time-resolved monitoring; multi-distance Rietveld method.
Supporting information
Portable Document Format (PDF) file https://doi.org/10.1107/S1600576724010057/vb5073sup1.pdf |