research papers
The observation of neutron interference using a crystal interferometer having a separate analyser opens the way to the construction and operation of interferometers with vast arm separation and length. Setting the design specifications requires a three-dimensional dynamical theory model of their operation. This paper develops the required three-dimensional mathematical framework, which also comprises coherent and incoherent illuminations; it is applied to study the visibility of the interference fringes.
Keywords: dynamical theory of X-ray diffraction; split-crystal interferometry; crystal neutron interferometry; crystal X-ray interferometry; X-ray coherence; neutron coherence.
Supporting information
Text file https://doi.org/10.1107/S1600576722008962/ei5084sup1.txt |