Figure 1
X-ray scattering of the empty capillary (filled circles), of the capillary filled with water (open circles), and water alone (crosses), after subtraction of the empty cell. The scattering from the empty capillary is multiplied by the transmission of water TH2 O. Each sample was measured for two series of 18 h. The dark current was subtracted from all measurements. The continuous line is the fit to the flat background. |