research papers
Combining precession electron diffraction data with X-ray powder diffraction data to facilitate structure solution
aLaboratory of Crystallography, ETH Zurich, Switzerland
*Correspondence e-mail: mccusker@mat.ethz.ch
Information derived from precession electron diffraction (PED) patterns can be used to advantage in combination with high-resolution X-ray powder diffraction data to solve crystal structures that resist solution from X-ray data alone. PED data have been exploited in two different ways for this purpose: (1) to identify weak reflections and (2) to estimate the phases of the reflections in the projection. The former is used to improve the partitioning of the reflection intensities within an overlap group and the latter to provide some starting phases for
The information was incorporated into a powder charge-flipping algorithm for structure solution. The approaches were first developed using data for the moderately complex zeolite ZSM-5, and then tested on TNU-9, one of the two most complex zeolites known. In both cases, including PED data from just a few projections facilitated structure solution significantly.Keywords: charge-flipping algorithms; precession electron diffraction; structure determination; X-ray powder diffraction; zeolites.
1. Introduction
Over the years, a broad palette of methods for determining the ), and references therein]. Recently, it was shown that even more complex structures can be addressed, if phase information derived from high-resolution (HRTEM) images is introduced into the procedure (Gramm et al., 2006; Baerlocher, Gramm et al., 2007; Baerlocher et al., 2008). In light of these results, the feasibility of using another, less demanding, technique, namely precession electron diffraction (PED), to augment the X-ray powder diffraction data has been explored.
of a polycrystalline material from X-ray powder diffraction (XPD) data has been developed, and it is now possible to solve moderately complex structures in an almost routine manner [see the review by David & Shankland (2008The key problem in θ values, though unrelated from a structural point of view, overlap in the powder pattern. As a result, their individual intensities are ambiguous, and this hinders structure solution. All methods of would benefit if this ambiguity could be resolved, at least in part. Two experimental approaches to this problem, both involving the collection of multiple X-ray powder diffraction data sets on the same sample under different conditions, have already been reported (Wessels et al., 2002). Both approaches, one exploiting anisotropic and the other have been shown to be effective, but both involve non-routine data collections and data analyses. Here we consider the viability of using one or more electron diffraction patterns to supplement a single high-resolution X-ray powder diffraction pattern.
from powder diffraction data arises from the fact that reflections with similar 2Electron and X-ray powder diffraction are remarkably complementary techniques (see Table 1). Electrons interact much more strongly with matter than do X-rays, so a single-crystal electron diffraction pattern can be obtained from a very tiny crystallite. Such patterns have two obvious advantages: (1) the pattern is that of a single crystal, so there is no reflection overlap, and (2) the interaction is stronger, so the resolution in d spacing is higher. However, the strong interaction generally results in complicated multiple scattering effects, which cause the reflection intensities to deviate severely from the kinematical assumption that Ihkl is proportional to |Fhkl|2 (Cowley, 1995). This is the main reason that electron diffraction data are not generally used for although there are some notable exceptions in the literature (e.g. Dorset, 1995; Zou & Hovmöller, 2008).
|
Almost 15 years ago, Vincent & Midgley (1994) introduced the precession electron diffraction technique as a partial solution to this problem. This technique is equivalent to the Buerger precession method used in single-crystal X-ray diffraction, where the crystal is precessed around the incident X-ray beam. In the PED case, however, the electron beam is deflected and precessed around a stationary crystal. With this tilted illumination, only a few reflections are excited simultaneously, so the possibilities for multiple scattering are reduced and the resulting diffraction intensities are more kinematical in nature. Now that commercial PED attachments for existing electron microscopes have become available, this promising technique has become accessible to a much broader community.
Although the PED reflection intensities are more reliable than those from a selected area electron diffraction (SAED) pattern, they are still not ideal. Own et al. (2006) have shown that dynamical effects still occur in PED patterns, with the high-d-spacing (low-angle) reflections being most affected. As might be expected, the precession angle and crystallite thickness proved to be critical parameters. Nonetheless, we reasoned that the PED patterns should contain information that could be used to advantage in combination with X-ray powder diffraction data.
Two possibilities for combining the information from the two sources were investigated. In one case, the PED data were simply used to identify the weak reflections in selected projections, with the hope that this information would lead to a more correct partitioning of some of the overlapping reflections in the powder pattern. In the second case, the single-crystal charge-flipping structure solution algorithm of Oszlányi & Sütő (2004, 2005, 2008) was applied to the two-dimensional PED data for selected zones to obtain phases for the contributing reflections. These phases were then included in the starting phase sets for the application of the powder charge-flipping (pCF) algorithm (Baerlocher, McCusker & Palatinus, 2007) to the X-ray powder diffraction data. This approach resembles that used previously for the combination of X-ray powder diffraction data with phases derived from HRTEM images.
To develop the two approaches, both simulated and experimental data for the moderately complex zeolite ZSM-5 (van Koningsveld et al., 1987; Pnma; a = 20.022, b = 19.899, c = 13.383 Å, 38 atoms in the 288 atoms in the unit cell) were used. The methods were then tested using experimental data for the very complex zeolite TNU-9 (Gramm et al., 2006; C2/m; a = 28.222, b = 20.012, c = 19.493 Å, 76 atoms in the 576 atoms in the unit cell).
2. Experimental
Samples of as-synthesized ZSM-5 and calcined TNU-9 were used for the powder diffraction data collections. For the PED measurements, both samples were calcined, crushed using a mortar and pestle, suspended in ethanol, and disaggregated with ultrasound. Structure factors for the simulations were calculated using the structural data published by van Koningsveld et al. (1987) for ZSM-5 and by Gramm et al. (2006) for TNU-9.
The experimental PED data were collected at 300 kV (λ = 0.0197 Å) on a Philips CM30 electron microscope equipped with a `Spinning Star' precession unit (NanoMegas) and a 16 bit Gatan 794 CCD camera. Exposure times were selected such that the diffraction intensities lay within the linear response range of the detector. The patterns were recorded with a precession angle close to 1° and the intensities were extracted using the program ELD (Zou et al., 1993) in the CRISP software package (Hovmöller, 1992). Phases from PED projections were derived using the single-crystal charge-flipping algorithm in the program Superflip (Palatinus & Chapuis, 2007).
The high-resolution synchrotron powder diffraction data for ZSM-5 were collected on the Swiss Norwegian Beamline (SNBL) at the ESRF in Grenoble (λ = 1.1011 Å) and those for TNU-9 at the SRS in Daresbury (λ = 0.99556 Å). The intensity extractions were performed using the program EXTRACT (Baerlocher, 1990) in the XRS-82 suite of programs (Baerlocher & Hepp, 1982).
The powder charge-flipping algorithm implemented in the program Superflip was used for structure solution (Baerlocher, McCusker & Palatinus, 2007). In this implementation, the intensity repartitioning procedure for overlapping reflections is coupled to a second modification of the based on histogram matching. The reference histogram used for this step simply reflects the chemical composition of the material.
3. Weak reflection elimination
Although it was hoped initially that all the PED data could be used directly to supplement the XPD data, this proved not to be possible, because (1) the PED intensities are still distorted from the kinematical case, and (2) the atomic scattering factors (and therefore the structure factors) for X-rays and electrons are not strictly proportional to one another (see Fig. 1). However, the scattering factors do show the same general trend. Dorset et al. (1998) exploited this similarity ten years ago to scale a set of SAED patterns to one another using the X-ray powder diffraction pattern as a reference. In our case, it was reasoned that reflections that are weak in the PED pattern should also be weak in the X-ray diffraction pattern.
A very simple and conservative procedure was applied to take advantage of this information. The PED data were used to identify the weak reflections in a projection, and then these reflections were eliminated from the XPD intensity extraction. Generally, the intensity ratios of overlapping reflections are set to one (equipartitioning), so weak reflections in an overlap group can be assigned medium or even large structure-factor amplitudes. It was hoped that, by eliminating these weak reflections from consideration, a more correct partitioning of the remaining reflections in the group would be obtained.
Initial tests of this weak reflection elimination (WRE) approach were performed on the zeolite ZSM-5 using both simulated and experimental PED patterns along four zone axes ([010], [], [] and []). The crystallite thicknesses for the PED measurements were estimated to be less than 100 nm. For simplicity, the structure-factor amplitudes were calculated using the kinematical assumption, and no geometrical corrections were applied. The PED amplitudes were scaled to the simulated ones by applying a least-squares fit to the data. Although the experimental patterns look qualitatively similar to the simulated ones (Fig. 2), there is considerable scatter in the amplitudes (Fig. 3). For the data shown in Fig. 3, for example, the R value for the agreement between the two is only 0.51. Similar scatter is observed in ten other [010] patterns collected over a period of time under different conditions. Data collected with a precession angle of 1.2° appear to be slightly better (0.51 ≤ R ≤ 0.53) than those collected with a precession angle of 0.8° (0.55 ≤ R ≤ 0.57). The reproducibility is also better with the higher precession angle (0.15 ≤ Rmerge ≤ 0.17 at 1.2° versus 0.19 ≤ Rmerge ≤ 0.22 at 0.8°).
In order to identify which reflections should be considered to be weak, an amplitude threshold had to be defined. It is important to note that, unlike the simulated data, the experimental PED intensities derived from different projections are not on the same scale, because they are taken with different illumination conditions, exposure times and crystal thicknesses (Gemmi et al., 2002), so it is not sensible to set the same threshold value for all four data sets. Attempts to scale the patterns to one another using common reflections were not very satisfactory, so it was considered to be better to treat each projection independently. The threshold for each projection was chosen for both the simulated and the experimental data by examining a plot of the amplitude distribution (Fig. 4) and selecting a value such that the reflections to be eliminated were in the range of the tail of the profile. To evaluate how sensitive the structure solution was to the choice of this threshold, ten values ranging from 10 to 100% of the average amplitude were tested. For each threshold, the reflections defined to be weak were eliminated from the hkl list and the remaining reflection intensities were re-extracted. Each of the 20 modified data sets (ten simulated and ten experimental) were then used as input for 100 runs of the powder charge-flipping algorithm (pCF) in the program Superflip (Palatinus & Chapuis, 2007).
The pCF solutions in Superflip are ranked according to an R value that compares the experimentally measured structure-factor amplitudes (|Fhkl|) with those derived from the charge-flipped map (|Ghkl|):
To evaluate the correctness of the electron density maps produced in the pCF runs, the ten best maps according to this Superflip R value were compared with a reference map calculated from the true structure, and an average agreement factor Rmap was calculated (Fig. 5). The correctness of the maps was found to be substantially better for threshold values within the 30–80% range and relatively stable within this range. It is apparent from these comparisons that the WRE method can improve the electron density maps produced by Superflip significantly. In contrast to pCF electron density maps generated without WRE, those generated with WRE (30–80% range) revealed the positions of all 12 Si and 26 O atoms in the clearly. It appears that even this simple modification of the data set has a significant impact on the structure solution.
4. Phase retrieval from precession electron diffraction data
Precession electron diffraction data have already been used in combination with et al., 2006) and maximum methods (Dorset et al., 2007; Gilmore et al., 2008a,b) to determine two-dimensional structures. This is an indication that the reflection intensities are reliable enough and have sufficient resolution for the phasing process to succeed. For three-dimensional structures, of course, a single projection is insufficient to solve the structure, but it was reasoned that, if the phases for selected projections could be determined from PED data, these phases could be used in combination with X-ray powder diffraction data in the same way as those derived from images. In this study, the charge-flipping algorithm of Oszlányi & Sütő (2004, 2005) rather than or maximum methods was used for the phase retrieval step.
(WeirichThe simulated and experimental electron diffraction data for ZSM-5 that were used to develop the weak reflection elimination approach were also used for these tests. The phase retrieval procedure was extremely simple and automatic. 100 charge-flipping runs, each with 500 iterations, were performed on each of four two-dimensional data sets (289 reflections for the [010] zone, 162 reflections for [], 124 reflections for [] and 246 reflections for []). The resolution for each of these data sets was ca 0.8 Å. For each projection, the five maps with the best Superflip R value were averaged. Then a Fourier transform was applied to calculate the phases of the corresponding reflections. Even though the symmetry of the map at this stage was P1, the space-group symmetry was imposed for this transformation to ensure that only phases consistent with a centrosymmetric were obtained. A comparison of these phases with the correct ones is given in Table 2.
|
It is readily apparent from Table 2 that the phases of the stronger reflections are more likely to be correct than those of the weaker reflections. If the total amplitude that is correctly phased is considered, this is more than 70% for all four zones, even for the experimental data. These numbers are similar to those obtained for phases derived from HRTEM images. The potential map generated from the PED amplitudes and the charge-flipping phases for the [010] projection of ZSM-5 is shown in Fig. 6. It can be seen from the projection of the structure that is overlaid that the major features are reproduced in the potential map. Thus, it would appear that the phases from PED projections might be as useful as those from an HRTEM image.
To test this, the 594 phases derived from the four PED charge-flipping runs were included in each starting phase set of 3042 reflections for pCF runs using the XPD data. All phases were allowed to change during the procedure. 100 pCF runs of 500 iterations were performed. As might be expected, the additional phase information resulted in electron density maps much closer to the true one. The final Rmap values dropped from 56.7% with just random phases in the starting phase set to 18.0% with the inclusion of the phases derived from the PED data.
5. Combination of the two methods
To evaluate the effect of combining the weak reflection elimination and phase retrieval approaches, a series of tests using one to four PED data sets were performed. The weak reflection threshold was simply chosen to be half the average amplitude. The results of these pCF runs are summarized in Table 3. It is clear from the electron density maps generated with and without the PED data that the PED data contribute significantly to the correctness of the map. Not only are all the atoms visible in the map, but their electron density ratios also better reflect the different sizes of Si and O, so (automatic) interpretation becomes easier.
|
6. TNU-9
The structure of TNU-9 ([Si192O384]) is one of the two most complex zeolite structures known (Gramm et al., 2006). It was originally solved by combining high-resolution XPD data with phases derived from HRTEM images in the zeolite-specific structure-solution program FOCUS (Grosse-Kunstleve et al., 1997). For structure solution, 258 phases were input to FOCUS, and after 16 days of computing time, the correct model with 24 Si atoms in the was found. To test the methods described in the previous sections, this extremely complex structure was re-investigated using the pCF algorithm supplemented with information derived from PED data.
Initial attempts to solve the structure using XPD data alone were not successful. The electron density maps with the best Superflip R values showed neither clear pores nor framework atom positions (Fig. 7a). Comparison of this map with the correct one yields an Rmap value of 78.8%. PED data were then used for weak reflection elimination and phase retrieval. For each PED projection, a plot of the amplitude distribution was examined to evaluate the appropriate amplitude threshold for WRE, and in each case, a value of half of the average amplitude was chosen. Using the procedure described in §§3 and 4, weak reflections were eliminated from the XPD hkl list and the intensities of the remaining reflections re-extracted, and phases were derived from different PED projections using the single-crystal algorithm in Superflip.
A series of pCF tests combining these data showed that the structure could be solved when five PED patterns ([001], [100], [102], [] and [] projections) were used. With these five patterns, 323 weak reflections could be eliminated and 176 phases derived. Then, 100 pCF runs of 600 iterations each were performed. The input phases were enforced for the first 50 iterations and were then allowed to change like the rest. The electron density maps with the best Superflip R values showed significant improvement over those generated using the XPD data alone. The peaks in the electron density maps were more spherical and the main features of the pore system appeared (Fig. 7b, Rmap = 51.3%). Although the best map showed the positions of 23 of the 24 Si atoms in the and many of the O atoms, the height of the peaks did not reflect the relative scattering powers of Si and O. Therefore, this map was used as a seed in Superflip to generate 100 new starting phase sets by allowing the phases calculated from the seed map to vary by up to 20% in a random fashion. The best electron density maps resulting from this second series of pCF runs showed all 24 Si atom positions and more realistic electron densities for Si and O (Fig. 7c, Rmap = 39.2%).
Although the solution of the structure of TNU-9 was not quite as simple as that of ZSM-5, the additional information from the PED data did make structure solution possible. The increased difficulty can probably be attributed to three factors: (1) the complexity of the structure (twice as many atoms in the unit cell), (2) the degree of reflection overlap (92.6% for TNU-9 versus 87.9% for ZSM-5) and (3) the lower resolution of the X-ray data (1.15 Å for TNU-9 versus 0.99 Å for ZSM-5). The charge-flipping algorithm is known to be particularly sensitive to the resolution of the data. Nonetheless, the structure could be solved in a relatively straightforward manner.
7. Conclusions
By supplementing X-ray powder diffraction data with precession electron diffraction data, it is possible to facilitate the solution of the crystal structures of polycrystalline materials. Such PED data are considerably easier to obtain than high-resolution
images and appear to contain similar information. PED data can be used to identify weak reflections in the X-ray powder diffraction pattern and thereby improve the reflection intensity extraction, and/or to obtain phase information for those reflections in the projection. The amount of correct phase information retrieved by applying a simple charge-flipping procedure to the two-dimensional single-crystal PED data is comparable to that that can be derived from an HRTEM image. In this initial investigation, we wanted to keep things as simple as possible, so no corrections were applied to the PED data. However, studies evaluating the effect of applying different corrections to the data are in progress.In this paper, we have discussed the application of these two approaches to two zeolite structures of different complexities using the powder charge-flipping algorithm in the program Superflip. However, the methods are generally applicable (i.e. not zeolite specific), so it should be possible to apply them to any polycrystalline material. Furthermore, introducing information from PED data to the structure solution procedure is not restricted to It could also be used to advantage in other programs (e.g. in the form of better intensities in a direct-space global-optimization program or as starting phases for trials). The precession electron diffraction technique offers a relatively simple route to valuable information that can be used to complement that in a powder diffraction pattern.
Acknowledgements
We thank the beamline scientists of the SNBL at ESRF and at the SRS for their assistance with the powder diffraction measurements. We also thank Lukas Palatinus for the program Superflip and for his continuing close collaboration on the powder diffraction aspects of that program. Funding from the Swiss National Science Foundation is gratefully acknowledged.
References
Baerlocher, Ch. (1990). EXTRACT. Institut für Kristallographie, ETH, Zürich, Switzerland. Google Scholar
Baerlocher, Ch., Gramm, F., Massueger, L., McCusker, L. B., He, Z. B., Hovmöller, S. & Zou, X. D. (2007). Science, 315, 1113–1116. Web of Science CrossRef PubMed CAS Google Scholar
Baerlocher, Ch. & Hepp, A. (1982). XRS-82. Institut für Kristallographie, ETH, Zürich, Switzerland. Google Scholar
Baerlocher, Ch., McCusker, L. B. & Palatinus, L. (2007). Z. Kristallogr. 222, 47–53. Web of Science CrossRef CAS Google Scholar
Baerlocher, Ch., Xie, D., McCusker, L. B., Hwang, S. J., Chan, I. Y., Ong, K., Burton, A. W. & Zones, S. I. (2008). Nat. Mater. 7, 631–635. Web of Science CrossRef PubMed CAS Google Scholar
Cowley, J. M. (1995). Diffraction Physics, 3rd ed. Amsterdam: Elsevier Science. Google Scholar
David, W. I. F. & Shankland, K. (2008). Acta Cryst. A64, 52–64. Web of Science CrossRef CAS IUCr Journals Google Scholar
Dorset, D. L. (1995). Structural Electron Crystallography. New York: Plenum Press. Google Scholar
Dorset, D. L., Gilmore, C. J., Jorda, J. L. & Nicolopoulos, S. (2007). Ultramicroscopy, 107, 462–473. Web of Science CrossRef PubMed CAS Google Scholar
Dorset, D. L., McCourt, M. P., Li, G. & Voigt-Martin, I. G. (1998). J. Appl. Cryst. 31, 544–553. Web of Science CrossRef CAS IUCr Journals Google Scholar
Gemmi, M., Calestani, G. & Migliori, A. (2002). Adv. Imag. Electron Phys. 123, 311–325. CrossRef CAS Google Scholar
Gilmore, C. J., Dong, W. & Dorset, D. L. (2008a). Acta Cryst. A64, 284–294. Web of Science CrossRef IUCr Journals Google Scholar
Gilmore, C. J., Dong, W. & Dorset, D. L. (2008b). Acta Cryst. A64, 295–302. Web of Science CrossRef IUCr Journals Google Scholar
Gramm, F., Baerlocher, Ch., McCusker, L. B., Warrender, S. J., Wright, P. A., Han, B., Hong, S. B., Liu, Z., Ohsuna, T. & Terasaki, O. (2006). Nature (London), 444, 79–81. Web of Science CrossRef PubMed CAS Google Scholar
Grosse-Kunstleve, R. W., McCusker, L. B. & Baerlocher, Ch. (1997). J. Appl. Cryst. 30, 985–995. Web of Science CrossRef CAS IUCr Journals Google Scholar
Hovmöller, S. (1992). Ultramicroscopy, 41, 121–135. CrossRef Web of Science Google Scholar
Koningsveld, H. van, van Bekkum, H. & Jansen, J. C. (1987). Acta Cryst. B43, 127–132. CSD CrossRef Web of Science IUCr Journals Google Scholar
Oszlányi, G. & Sütő, A. (2004). Acta Cryst. A60, 134–141. Web of Science CrossRef IUCr Journals Google Scholar
Oszlányi, G. & Sütő, A. (2005). Acta Cryst. A61, 147–152. Web of Science CrossRef IUCr Journals Google Scholar
Oszlányi, G. & Sütő, A. (2008). Acta Cryst. A64, 123–134. Web of Science CrossRef IUCr Journals Google Scholar
Own, C. S., Marks, L. D. & Sinkler, W. (2006). Acta Cryst. A62, 434–443. Web of Science CrossRef CAS IUCr Journals Google Scholar
Palatinus, L. & Chapuis, G. (2007). J. Appl. Cryst. 40, 786–790. Web of Science CrossRef CAS IUCr Journals Google Scholar
Vincent, R. & Midgley, P. A. (1994). Ultramicroscopy, 53, 271–282. CrossRef CAS Web of Science Google Scholar
Weirich, T. E., Portillo, J., Cox, G., Hibst, H. & Nicolopoulos, S. (2006). Ultramicroscopy, 106, 271–282. Web of Science CrossRef Google Scholar
Wessels, T., Baerlocher, Ch., McCusker, L. B. & David, W. I. F. (2002). Structure Determination from Powder Diffraction Data, edited by W. I. F. David, K. Shankland, L. B. McCusker & Ch. Baerlocher, pp. 162–178. New York: Oxford University Press. Google Scholar
Zou, X. D. & Hovmöller, S. (2008). Acta Cryst. A64, 149–160. Web of Science CrossRef CAS IUCr Journals Google Scholar
Zou, X. D., Sukharev, Y. & Hovmöller, S. (1993). Ultramicroscopy, 49, 147–158. CrossRef CAS Web of Science Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.