Figure 8
Results of the multi-dimensional Rietveld refinement for a neutron TOF measurement of diamond. (a) The observed pattern, (b) the calculated pattern, (c) the difference pattern, (d) a 1D plot of multi-dimensional refinement and (e) the conventional one-dimensional refinement. Blue lines indicate peak positions. The color scale shows normalized intensity in plots (a)–(c). |