research papers
Determination of crystallographic intensities from sparse data
aLaboratory of Atomic and Solid State Physics, Cornell University, Ithaca, NY 14853, USA, bField of Biophysics, Cornell University, Ithaca, NY 14853, USA, cCornell High Energy Synchrotron Source (CHESS), Cornell University, Ithaca, NY 14853, USA, and dKavli Institute at Cornell for Nanoscale Science, Cornell University, Ithaca, NY 14853, USA
*Correspondence e-mail: ksa47@cornell.edu
X-ray serial microcrystallography involves the collection and merging of frames of diffraction data from randomly oriented protein microcrystals. The number of diffracted X-rays in each frame is limited by radiation damage, and this number decreases with crystal size. The data in the frame are said to be sparse if too few X-rays are collected to determine the orientation of the microcrystal. It is commonly assumed that sparse crystal diffraction frames cannot be merged, thereby setting a lower limit to the size of microcrystals that may be merged with a given source fluence. The EMC algorithm [Loh & Elser (2009), Phys. Rev. E, 80, 026705] has previously been applied to reconstruct structures from sparse noncrystalline data of objects with unknown orientations [Philipp et al. (2012), Opt. Express, 20, 13129–13137; Ayyer et al. (2014), Opt. Express, 22, 2403–2413]. Here, it is shown that sparse data which cannot be oriented on a per-frame basis can be used effectively as crystallographic data. As a proof-of-principle, reconstruction of the three-dimensional diffraction intensity using sparse data frames from a 1.35 kDa molecule crystal is demonstrated. The results suggest that serial microcrystallography is, in principle, not limited by the fluence of the X-ray source, and collection of complete data sets should be feasible at, for instance, storage-ring X-ray sources.
Keywords: X-ray serial microcrystallography; sparse data; reconstruction of diffraction intensity; EMC algorithm.
1. Introduction
Serial microcrystallography was developed as a way of taking advantage of the high fluence provided by X-ray free electron lasers to image small microcrystals (ca 1 µm3 or smaller) (Chapman et al., 2011; Boutet et al., 2012). Due to the short time duration of the pulse (<50 fs), the principle of `diffraction before destruction' is applicable, where the pulse outruns most of the radiation damage. This allows the capture of relatively damage-free snapshot diffraction patterns. A large number of these patterns are captured by flowing a stream of crystals past the beam. Enough photons are scattered in this interval to allow indexing algorithms (White et al., 2012) to determine the orientation of individual frames and to generate the three-dimensional intensity distribution of the diffraction.
This approach was reproduced at a synchrotron source (Stellato et al., 2014) with larger crystals (135 µm3) and the same indexing method. However, with micron-sized crystals, around 100 times fewer photons would be scattered. Another possible application would be in the imaging of two-dimensional membrane protein crystals, given their weak diffraction (Feld & Frank, 2014). In both cases, there might be too few photons in a single frame to allow indexing of Bragg spots. The data may have the sparse nature of Philipp et al. (2012) and Ayyer et al. (2014), where it is impossible to recover the orientation of a single frame by itself. Fortunately, as in those cases, we show that one can apply the EMC algorithm to crystal diffraction (Loh & Elser, 2009) to simultaneously assign orientations probabilistically and solve for the three-dimensional intensities. Other algorithmic methods have been used (Fung et al., 2008; Shneerson et al., 2008; Kassemeyer et al., 2013; Xu et al., 2014) to assign orientations and extract the three-dimensional structure from two-dimensional snapshot(s), but they have been applied to much higher signal images.
To simulate the sparse data frame conditions from a 1 µm3 crystal at a storage-ring synchrotron source, we have performed an experiment with a large 400 µm crystal using a standard laboratory X-ray source with diffraction images recorded at a high frame rate. Each frame was acquired with the crystal in an arbitrary orientation around a single rotation axis. Even with an average signal level as low as 48 photons per frame (4.8 × 10−4 photons per pixel), we demonstrate successful recovery of orientation about the axis of rotation and reconstruction of three-dimensional intensities. We compare our reconstruction with a high-fluence data set where the orientations were recorded. We also examine the effect of background scatter on the quality of the reconstruction and the ability to recover orientations. The ability of the EMC algorithm to recover the three-dimensional intensities from sparse data, albeit from a large crystal, is an important step towards the development of EMC-based serial protein crystallography.
2. Reconstruction algorithm
A slightly modified version of the EMC algorithm (Loh & Elser, 2009) was used to iteratively assign orientations and reconstruct the three-dimensional intensity distribution. One feature of this technique is that all regions of are treated equally. No particular preference is given to points. This is in contrast with the approach taken by indexing algorithms which emphasize the Bragg spots to the extent of ignoring the diffuse scattering. In the case of sparse data, most Bragg spots will produce no photons and some of the photons could be from non-Bragg background, making this approach impractical. A short review of the algorithm is given below.
The EMC algorithm has three steps in each iteration (expand, maximize and compress). Firstly, the space of available orientations is discretized to a finite number of angles. The expand and compress steps convert to and from the three-dimensional intensity distribution and the expected intensity at the detector in each of these orientations, which we call `views'. This is done using linear interpolation and the fact that detector pixels lie along the The maximize step uses the data frames to update the views using expectation-maximization, as described below.
Once the views have been obtained for each discrete orientation, the probability of a frame being generated by a view is calculated by assuming Poisson statistics for the number of photons recorded given an intensity. Thus, if the intensity at pixel t in view r is Wrt, the probability P of frame d with Kdt photons at pixel t being generated by view r is given by
where the Kdt! term has been omitted as it cancels out between the numerator and the denominator. Using these probabilities, the likelihood of maximizing an updated view W′rt is given by
This intuitive update rule ends up being just the Pdr calculated from the current model. The expand–compress cycle is necessary to impose consistency among different views by requiring that they come from a common three-dimensional model.
over the data frames, with the weights being the probabilities calculated using the current model. These updated views maximize the likelihood of generating the data, given the probabilities2.1. Three-dimensional hkl space
One modification to the traditional algorithm is in the choice of space for the three-dimensional intensity distribution. The standard choice is Fourier space, where the slice representing the detector plane is the surface of a sphere passing through the origin (the Ewald sphere). Here, for reasons explained below, the best choice is hkl space, where the three axes represent the fractional coordinates with respect to the reciprocal Thus, the points lie on a cubic grid with integer spacing, regardless of the unit-cell parameters. Unless the crystal has cubic symmetry, the detector pixels will no longer lie on the surface of a sphere but along some other surface. The pixel coordinates in this space can be calculated by using the basis vectors to determine the scaling and rotational transformation to the surface.
With our choice of hkl space, the Bragg peaks all map to a cubic grid. Thus, while interpolating in the expand and compress steps, symmetry-related Bragg peaks see the same environment, which would not necessarily be the case if the basis vectors did not lie along the grid axes. This is important, because the maximize step is sensitive to slight variations among these peaks caused by interpolation errors. These errors are not a major factor in the case of non-Bragg intensity distributions where the variation is smooth on a one-pixel scale.
To define such a space, one needs to know the unit-cell vectors. These can be determined from the (high-signal) angle-averaged data, if not already known.
2.2. Initial guess
As with any iterative algorithm, the initial-guess model must be specified. In this case, once the mapping of pixels to hkl space has been defined, the model is constructed by placing a three-dimensional Gaussian of random height at each lattice point. This cubic grid of random intensities is used as the input for the first iteration. Other than this initial guess and the use of hkl space, no other is assumed during the reconstruction.
2.3. Rotation group subset
In general, the set of views, r, is generated by sampling the three-dimensional rotation group uniformly. This is done with the help of unit quaternions. However, in cases where the crystal is rotated about a single axis and the relative orientation of the axis with respect to the crystal basis vectors is known, one can sample angles about just that axis. This was done in this experiment, where the axis was determined from the high-fluence data set using the XDS software (Kabsch, 2010).
3. Data collection
The sample studied was a 400 µm sized small-molecule single crystal with chemical formula C78H120Mo2N6O (molecular weight 1.35 kDa). It was mounted on the end of a glass fiber attached to a goniometer head, which allowed the crystal to be centered on the rotation axis. A rotation stage (Newport URS100) was set to rotate continuously at 0.1° s−1 during data collection. Although the angle of rotation was known for each frame, it was not passed to the reconstruction algorithm. The crystal was illuminated by a Mo Kα beam generated by a Rigaku RU-H3R rotating anode set to 30 kV and 40 mA. Filtering was done using 200 µm of Zr foil to increase the fraction of Kα radiation. The X-rays were focused to a spot of size 0.5 × 0.5 mm using Ni-coated Franks mirrors 1 m from the sample, with a beam convergence of 1 mrad and an intensity of 106 photons s−1. The data were recorded using an MMPAD detector (Tate et al., 2013) at a distance of 37 mm from the sample. Two data sets were collected, one with low fluence at 10 ms per frame and the other with high fluence at 500 ms per frame. The low-fluence data set was taken in groups of 1000 consecutive frames, with a time delay between sets to allow the frames to be written to disk.
The data were then thresholded and photon counts were obtained using a procedure similar to that employed by Ayyer et al. (2014). In the low-fluence data set there were 4.3 million frames with an average of 3.2 photons per frame. Since the crystal rotated only 10−3° between two successive frames, multiple data sets were prepared by combining successive frames within a batch. Table 1 lists the details of the different data sets. Fig. 1 shows the first six frames from the 48 photons per frame data set.
|
Fig. 2 shows the angle-averaged pattern obtained by summing over all data frames. The radial streaks near the Bragg spots are caused by the polychromaticity of the beam. The arcs near the rotation axis are caused by the these streaks intersecting the curved Since the exact shape of the arc is very sensitive to the rotation axis, a region of the image within 11 pixels of the rotation axis was not used in the calculation of Pdr.
4. Results
The crystal analyzed had a body-centered cubic (b.c.c.) hkl space (§2.1). The high-fluence data set with known orientations was used to generate a reference three-dimensional intensity model. This was compared with the reconstructions from different low-fluence data sets by comparing the Patterson maps, which were generated as follows. First, the intensities were integrated in a small sphere about every hkl point. The three-dimensional hkl grid of intensities was then inverse Fourier transformed to generate the electron-density auto-correlation function, which is the Fig. 3 shows a comparison of the maps for one particular data set (48 photons per frame). For a quantitative comparison, we have calculated an R factor between the Fourier amplitudes of the low- and high-fluence reconstructions (Rhigh-low), shown in Fig. 4. This quantity was calculated as follows
with a lattice constant of 21.47 Å in . The unit-cell parameters were taken as a given and used to generate the mapping towhere Fhkl = (Ihkl)1/2 and Ihkl refers to the integrated intensity at Bragg peak (h, k, l). We observe that, at low resolutions, this R factor is near 0.14. At high q [= (h2 + k2 + l2)1/2], the lack of good statistics in the high-fluence data set leads to a large value. This is illustrated in Fig. 4 by the dashed line, which represents the mean number of photons per peak in a given resolution shell.
4.1. Dependence on photons per frame
As mentioned in §3, the crystal is rotated by 10−3° over one frame. This allows us to collapse successive frames, as they come from almost identical orientations. Using this method, we could study the effect of the number of photons per frame on reconstruction quality while keeping other parameters the same. One effect of decreasing the number of photons per frame was that it took more iterations to reach convergence. For less than 48 photons per frame, the reconstruction did not converge at all. Above this threshold value, the reconstruction quality was independent of the number of photons per frame. However, it took many more iterations, as can be seen in Fig. 5 and Table 1. This is consistent with the observations in simulations with speckle intensity patterns (Loh & Elser, 2009). The threshold value itself is lower because of the different distribution of the intensity in this case (concentrated in Bragg peaks as opposed to large smooth speckles). While the situation might be affected by other factors, such as beam monochromaticity and crystal the rate of convergence will still be principally determined by the number of photons per frame.
4.2. Addition of background
The large non-hydrated crystal that we used provided relatively little background scattering compared with the Bragg spots. To study the effect of uniform background on the quality of the reconstruction, additional photon counts were added, with a
of uniform mean, to each data frame of the 314 photons per frame data set. Except in the cases of extreme background, there is no effect on the orientation recovery. The weak highest-resolution peaks are lost as they are drowned out by the noise in the background. This is an unavoidable aspect of crystallography.To demonstrate the successful recovery of orientation at different background levels, the ratio of average intensity per voxel in the neighborhood of a Bragg point to the average intensity in the diffuse region is plotted versus reciprocal length, q, in Fig. 6. If this ratio is close to 1, the Bragg peaks do not stand out over the background. As the plot shows, even with high background, the strong low-resolution peaks are successfully recovered. However, as expected, the weak high-resolution peaks are lost.
4.3. Computational details
The reconstruction was performed on a single machine (Intel Xeon E5-2640 @ 2.00 GHz with 128GB RAM running Scientific Linux) and took around 15 s per iteration using 20 cores. The three-dimensional hkl grid was chosen to have a cubic lattice constant of 10 voxels. The detector geometry then meant that the grid was 366 × 366 × 366 voxels in size. The initial model was generated by placing a three-dimensional Gaussian of random height and width 2 voxels centered at each point satisfying the b.c.c. selection rule (h + k + l = even). A similar procedure was performed during peak integration, when the values in a sphere of radius 2 voxels around each peak were summed to calculate the Bragg intensity.
Since the rotation axis with respect to the crystal axes was taken to be a given, 1150 (≃ π × 366) equally spaced orientations were sampled about that axis.
We consistently observed that, if the algorithm converged, it produced very similar maps. Thus, convergence was taken to be an indicator of a successful reconstruction. Here, iterative convergence occurs when the iterate stops changing from one iteration to the next. Some convergence plots are shown in Fig. 5.
5. Conclusions
We have shown that the three-dimensional diffraction intensity distribution can be calculated from a large number of sparse data frames, each with unknown orientation. This result bodes well for the possibility of performing serial crystallography with micron-sized or smaller microcrystals at synchrotron sources. Complications will no doubt arise when the method is applied to protein crystals of decreasing size and an additional degree of rotational freedom, as we intend to do in follow-up studies. Still, it is promising that successful reconstruction of the three-dimensional intensities has been shown for a signal level as low as 48 photons per frame.
We also observe that the addition of relatively high levels of uniform background (400%) does not affect orientation recovery. This is important, as some base level of background scattering is unavoidable with protein crystals due to the solvent internal to the crystal. As is the case in all protein crystallography experiments, the background reduces the resolution as higher order peaks are drowned out. Reducing the background requires minimizing the amount of material in the beam path. Fortunately, it is possible to reduce the background to insignificant levels by appropriate X-ray optics, vacuum paths and graphene windows surrounding the crystal stream (Wierman et al., 2013). For example, one can envision flowing a filtered set of uniformly sized microcrystals down a minimally sized tube equipped with graphene X-ray windows in an otherwise totally vacuum environment. If the exposure times are longer, fast-framing detectors (Koerner & Gruner, 2011; Johnson et al., 2014) can be used to restrict artificially the net degree of angular diffusion over an exposure.
One feature of the serial crystallography experiment not replicated here is the collection of data from all orientations in three dimensions. Reconstruction from the full rotation group was studied in simulations by Loh & Elser (2009) for aperiodic structures with speckle intensity distributions. There, it was shown that the number of photons per frame required for successful reconstruction grows only logarithmically with the number of orientational samples. Although the total number of photons required for a complete data set with a good signal-to-noise ratio and good resolution will be higher than what was collected here, with the fluence available at third-generation X-ray sources one should be able to collect a complete data set of similarly sparse nature with micron-sized crystals. This suggests that sub-micron room-temperature serial microcrystallography should be feasible. Experiments to examine this prediction will, no doubt, be performed.
Acknowledgements
Research on the development and application of X-ray detectors was supported by DOE Grant DE-FG02-10ER46693, the Keck Foundation and CHESS. CHESS is supported by the NSF and NIH/NIGMS via NSF award DMR-1332208, and the MacCHESS resource is supported by NIGMS award GM-103485. The data analysis work was supported by DOE Grant DE-FG02-11ER16210. The authors thank Emil Lobkovsky for kindly providing the sample.
References
Ayyer, K., Philipp, H. T., Tate, M. W., Elser, V. & Gruner, S. M. (2014). Opt. Express, 22, 2403–2413. CrossRef PubMed Google Scholar
Boutet, S. et al. (2012). Science, 337, 362–364. CrossRef CAS PubMed Google Scholar
Chapman, H. N. et al. (2011). Nature, 470, 73–77. Web of Science CrossRef CAS PubMed Google Scholar
Feld, G. K. & Frank, M. (2014). Curr. Opin. Struct. Biol. 27, 69–78. CrossRef CAS PubMed Google Scholar
Fung, R., Shneerson, V., Saldin, D. K. & Ourmazd, A. (2008). Nat. Phys. 5, 64–67. Web of Science CrossRef Google Scholar
Johnson, I. et al. (2014). J. Instrum. 9, C05032. CrossRef Google Scholar
Kabsch, W. (2010). Acta Cryst. D66, 125–132. Web of Science CrossRef CAS IUCr Journals Google Scholar
Kassemeyer, S., Jafarpour, A., Lomb, L., Steinbrener, J., Martin, A. V. & Schlichting, I. (2013). Phys. Rev. E, 88, 042710. CrossRef Google Scholar
Koerner, L. J. & Gruner, S. M. (2011). J. Synchrotron Rad. 18, 157–164. Web of Science CrossRef IUCr Journals Google Scholar
Loh, N.-T. D. & Elser, V. (2009). Phys. Rev. E, 80, 026705. Web of Science CrossRef Google Scholar
Philipp, H. T., Ayyer, K., Tate, M. W., Elser, V. & Gruner, S. M. (2012). Opt. Express, 20, 13129–13137. Web of Science CrossRef CAS PubMed Google Scholar
Shneerson, V. L., Ourmazd, A. & Saldin, D. K. (2008). Acta Cryst. A64, 303–315. Web of Science CrossRef CAS IUCr Journals Google Scholar
Stellato, F. et al. (2014). IUCrJ, 1, 204–212. CrossRef CAS PubMed IUCr Journals Google Scholar
Tate, M. W., Chamberlain, D., Green, K. S., Philipp, H. T., Purohit, P., Strohman, C. & Gruner, S. M. (2013). J. Phys. Conf. Ser. 425, 062004. CrossRef Google Scholar
White, T. A., Kirian, R. A., Martin, A. V., Aquila, A., Nass, K., Barty, A. & Chapman, H. N. (2012). J. Appl. Cryst. 45, 335–341. Web of Science CrossRef CAS IUCr Journals Google Scholar
Wierman, J. L., Alden, J. S., Kim, C. U., McEuen, P. L. & Gruner, S. M. (2013). J. Appl. Cryst. 46, 1501–1507. Web of Science CrossRef CAS IUCr Journals Google Scholar
Xu, R. et al. (2014). Nat. Commun. 5, 4061. Web of Science PubMed Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.