- 1. Introduction
- 2. The Structural Biology Knowledgebase: an integrated resource for all biologists
- 3. Virus maturation and the VIPERdb virus structure database
- 4. Expanding our knowledge of the protein universe: modeling protein structures by homology
- 5. Conformation-independent structural comparison of macromolecules with ProSMART
- 6. The LabDB laboratory information management system
- 7. Data to knowledge: the Cambridge Structural Database
- 8. Conclusions
- References
- 1. Introduction
- 2. The Structural Biology Knowledgebase: an integrated resource for all biologists
- 3. Virus maturation and the VIPERdb virus structure database
- 4. Expanding our knowledge of the protein universe: modeling protein structures by homology
- 5. Conformation-independent structural comparison of macromolecules with ProSMART
- 6. The LabDB laboratory information management system
- 7. Data to knowledge: the Cambridge Structural Database
- 8. Conclusions
- References
feature articles
Data to knowledge: how to get meaning from your result
aCenter for Integrative Proteomics Research, Department of Chemistry and Chemical Biology, Rutgers, State University of New Jersey, Piscataway, NJ 08854, USA, bCambridge Crystallographic Data Centre, 12 Union Road, Cambridge CB2 1EZ, England, cDepartment of Integrative Structural and Computational Biology, Scripps Research Institute, La Jolla, CA 92037, USA, dMRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge Biomedical Campus, Cambridge CB2 0QH, England, eBiozentrum, University of Basel, Klingelbergstrasse 50-70, 4056 Basel, Switzerland, fSIB-Swiss Institute of Bioinformatics, Basel, Switzerland, and gDepartment of Molecular Physiology and Biological Physics, University of Virginia, Charlottesville, VA 22908, USA
*Correspondence e-mail: wladek@iwonka.med.virginia.edu
Structural and functional studies require the development of sophisticated `Big Data' technologies and software to increase the knowledge derived and ensure reproducibility of the data. This paper presents summaries of the Structural Biology Knowledge Base, the VIPERdb Virus Structure Database, evaluation of homology modeling by the Protein Model Portal, the ProSMART tool for conformation-independent structure comparison, the LabDB `super' laboratory information management system and the Cambridge Structural Database. These techniques and technologies represent important tools for the transformation of crystallographic data into knowledge and information, in an effort to address the problem of non-reproducibility of experimental results.
Keywords: meaning from data; big data; databases; knowledge bases; data deposition.
1. Introduction
The processing of structural information, particularly when combined with functional and evolutionary data, is a sophisticated process that requires the use of `big data' paradigms for effective data management (Zimmerman et al., 2014), as well as for checking data integrity and accuracy (Cooper et al., 2011; Dauter et al., 2014; Domagalski et al., 2014; Wlodawer et al., 2013). Big data traditionally refers to the analysis of very large data sets (on the scale of tera- or petabytes), and indeed the amount of data collected on a single protein crystallography synchrotron beamline station in one day may easily exceed one terabyte. However, with the steady progress in computer technology and the application of modern technologies like cloud computing, the amount of data is one of the easiest problems to deal with. The main difficulty can be summarized by the quotation, `Data is not information, information is not knowledge, knowledge is not understanding, understanding is not wisdom' (attributed to Clifford Stoll and Gary Schubert; Keeler, 2006). Sophisticated technologies, including new software, must be developed to handle data management in the wet laboratory and relate it to structural and functional data. Such systems will both increase the knowledge we can derive from our data and be likely to improve data reproducibility. Similarly, new software and databases have to be developed to analyze a large number of macromolecular structures, including complexes with small-molecule agents, in the context of functional and biomedical information.
The microsymposium session `Data to knowledge: how to get meaning from your result' (MS-30), held at the 23rd Congress and General Assembly of the International Union of Crystallography (IUCr; Montreal, Canada, 5–12 August 2014), was devoted to the evaluation of the current status of the road leading from crystallographic data to knowledge, and to discuss what we have to do in the future to make this road less bumpy. Several elite speakers were invited to present their work and future plans in a wide range of fields that can improve this conversion and have an impact on the issue of reproducibility of results (Carp, 2013; Collins & Tabak, 2014; Franzoni et al., 2011; Prinz et al., 2011). In this paper we present abbreviated summaries of these presentations.
2. The Structural Biology Knowledgebase: an integrated resource for all biologists
2.1. Overview
The Structural Biology Knowledgebase (SBKB, https://sbkb.org ) was established to facilitate research design and analysis for a wide variety of biological systems (Gabanyi et al., 2011). It serves as a single resource for a biologist, giving access to integrated sequence, structure and functional information, in addition to the available technical information reported by over two dozen contributing laboratories. The unique combination of this data allows researchers to gather new knowledge and ideas, and make informed decisions about projects in ways not possible before.
The core SBKB database aggregates and integrates Protein Data Bank (PDB; Berman et al., 2014) structures; theoretical models from the Protein Model Portal (Haas et al., 2013); outcomes and experimental protocols from TargetTrack; and DNA expression clones from the PSI:Biology-Materials Repository (Seiler et al., 2014), with a diverse collection of over 100 genomic, proteomic, structural, cell biological and medical data resources, encompassing functional annotations, pathways, protein expression/localization profiles, health and disease relationships, and pharmacology. As shown in Fig. 1, the SBKB can be searched by sequence, UniProt accession code or PDB ID, yielding reports combining atomic coordinates, theoretical or comparative models, annotations, experimental protocols and expression clones, ordered by sequence identity. Text searches return PDB structure hits, ranked by biological relevance (Julfayev et al., 2012) or specified annotation, pertinent information from the Technology Portal (Gifford et al., 2012) and relevant literature from the PSI Publications Portal. The SBKB also adds value by serving as a clarifying guide to a host of external resources. Customized `hubs' were created to streamline data access for a number of important research areas (Structure–Sequence–Function resources, Homology Modeling, Transmembrane Proteins, Methods and Technologies, and Structural Targets). The SBKB also partners with Nature Publishing Group to highlight the impact of structural biology on specific areas of biological research.
By aggregating this data, one can quickly view the level of knowledge there is about any given protein sequence through a single search. A user only has to know the protein's sequence, unbiased by protein names or other text annotations that can change over time, to receive a list of the matching and homologous (>30% sequence identity) structures, models, target histories and DNA clones. Theoretical models, experimental progress and their annotations are still presented in the absence of an experimental structure, to provide an extended view of biology in three dimensions. The annotation notebook, which spans a wide range from gene level to medical resources, summarizes which resources have information and which ones do not, indicating directions for future research (Fig. 2).
2.2. Modeling and prediction tools
Many tools have been developed by the SBKB to enable real-time predictions when ample data are not yet available. For example, the Sequence Comparison and Analysis tool (https://sbkb.org/sca ) submits a construct sequence to two crystallizability prediction servers, XtalPred (Jahandideh et al., 2014) and Pxs (Price et al., 2009), which calculate several parameters such as surface and hydrophobicity, and ordered and disordered propensities. These results are combined with an SBKB report of existing structures, models and targets, so that further information about existing homologous structures, annotations, and the protocols used for both failed and successful protein production trials can be reviewed for insightful tips.
The Protein Model Portal (PMP), which houses over 20 million pre-computed comparative models of protein sequences, has also created a real-time interactive modeling tool that will submit the user's sequence to eight partner servers for possible novel modelling or re-modeling based on newer structural templates. Since model quality determines the usability of a model for specific applications, the PMP helps assess the reliability of the new models by submitting it to three well established quality estimation servers. Since there are >50 000 000 sequences in UniProtKB, and now >100 000 structures in the PDB, such models can be very useful for hypothesis-driven research in the absence of an experimental structure.
Additional search tools have been developed to predict and locate structures based on their function. The KB-Rank tool (https://protein.tcmedc.org/KB-Rank/ ) is a text search tool that retrieves a list of protein structural chains related to functional or disease-related annotations (Julfayev et al., 2012). Its unique feature is that structural chains within each retrieved category are ranked according to their estimated relevance to the queried text, based on their prevalence (frequency) in the literature and in annotation resources. The KB-Role tool (https://protein.tcmedc.org/KB-Role/ ) uses information derived from a protein sequence and three-dimensional structure to predict a likely Gene Ontology term association (Julfayev et al., 2011). Each prediction has an assigned probability value, so a user can assess whether it is to be considered for further study.
2.3. Quality assurance
The SBKB also strives to deliver only high-quality curated data from established resources, and its developers are keenly aware of the dangers of cyclical propagation of incorrect annotations. To power our search tools, we perform a weekly review of the collected annotations for errors and inconsistencies, and resolve them with the provider. Over the years, we have worked with model organism databases and EBI annotation teams, resolving issues ranging from improper mappings of structural annotations in non-structurally determined regions, to corrupted output files resulting in lack of data, to changes in data delivery format and nomenclature. Such audits are required to ensure that the community always receives the full and latest compliment of annotations available, from SBKB and other resources.
In this era of big data, there is still much to be done to align all of the data housed with public biological databases so that further biological knowledge can be realised. The SBKB represents the first step towards making that a practical reality.
3. Virus maturation and the VIPERdb virus structure database
3.1. Overview of VIPERdb
The Virus Particle ExploreR (VIPERdb) database provides the non-expert in structural virology with access to the coordinates from the 420 X-ray crystallography structures determined for viruses with icosahedral symmetry (Carrillo-Tripp et al., 2009). The size range of these particles extends from 150 Å, for the smallest viruses formed by 60 copies of the same gene product, to over 1000 Å, for adenovirus formed by 13 different gene products (Benevento et al., 2014; Reddy & Nemerow, 2014). Each virus has a main page that provides details of both the virus and the structural study, and this can be found by virus name, PDB code, or as a member of a subset based on the family name or T number. The coordinates for all the viruses are organized relative to the same orthogonal coordinate system, allowing straightforward comparisons and operations among the entire database. A variety of options are available for displaying the virus particle, including rendered volumes color-coded by subunit type, color-coded by radius, displayed with a `cage' that shows the quasi-equivalence of the capsid, or a ribbon drawing of the subunits in the icosahedral Based on their standard labeling, the coordinates of any oligomer of icosahedral asymmetric units can be downloaded for analysis and display using a graphics program of the user's choice. There are a variety of derived results available directly as tables or graphs, such as the buried surface area at the unique subunit interfaces and the amount contributed by each residue at the interface. Stabilization energy is estimated from the buried surface, giving the contribution of each residue to the overall stability of the interface. Comparisons of derived results can be made among members within a virus family through a graphical user interface (GUI) that directly provides all of these for each virus, and these can be sorted on any given property. Visual comparisons among all the viruses in the database can be made through the gallery maker. Viruses for comparison can easily be selected and displayed on the same relative scale in a single image. The best way to become acquainted with the database is to begin using it. There is an extensive tutorial provided, but most of the operations are intuitive and accessible to the non-expert with little training.
3.2. A case study: maturation of Nudaurelia Omega Capensis virus
A study of virus maturation provides an example of the use of VIPERdb. Nudaurelia Omega Capensis virus (NWV) is a non-enveloped single-stranded RNA insect virus with T = 4 quasi-symmetry, i.e. the particle contains four copies of a single type of gene product (644 amino acids) in the icosahedral creating local two-, three- and sixfold quasi-symmetry axes in addition to the icosahedral symmetry (Dorrington & Short, 2010). NWV undergoes large-scale particle reorganization between the immature procapsid and the mature capsid, as well as an autocatalytic cleavage of the subunits between residues 570 and 571 (Canady et al., 2000) (see Fig. 3). The virus initially assembles at neutral pH within the gut cells of Lepidoptera larvae and matures late in the infected cell when the cell undergoes infection-induced apoptosis, with an associated reduction in pH to 5 (Tomasicchio et al., 2007). The process can be recapitulated in vitro by expressing the capsid protein of NWV in a baculovirus system and purifying the procapsids. Maturation does not take place in the baculovirus system because the SF21 cells used for expression do not undergo apoptosis.
VIPERdb was used to analyze the residues at subunit interfaces determined by the 2.8 Å crystallographic analysis of the mature virus (Helgstrand et al., 2004). As expected for pH-dependent structural changes, a large number of acidic residues were found at the subunit interfaces. The X-ray coordinates were used for computing the electrostatic potential of the subunit surfaces at pH 7.5 and 5.0, demonstrating the large change in electrostatic repulsion between the two pH values (Matsui et al., 2009). Purified procapsids were titrated at pH intervals of 0.2 between 7.6 and 5.0, and their size distribution examined by small-angle X-ray scattering (SAXS) (Matsui, Tsuruta & Johnson, 2010). The particle population was essentially uniform at each pH value, as demonstrated by the precise fitting of spherical models to the SAXS data. The resulting based on radius showed that the overall pKa of the particle is 5.9. Maturation cleavage initiated at pH 5.5, but would not go to completion within 24 h unless the pH was lowered to 5.2. The kinetics of the cleavage were measured by the change in Coomassie stain in sodium dodecyl sulfate–polyacrylamide gel (SDS–PAGE) patterns at the mass corresponding to full length (644 amino acids) and at the mass of the cleaved subunit (570 amino acids). At pH 5, half of the subunits cleaved in 30 min, but it took another 4 h for the remaining subunits to cleave. This suggests that the four subunits in the icosahedral cleave at different rates depending on their position. Subunits designated A form pentamers, while subunits labeled B, C and D form quasi-hexamers at the icosahedral twofold symmetry axes. D subunits cluster about the icosahedral threefold symmetry axes, while A, B and C form a similar quasi-threefold axis. The DDD and ABC trimers are related by a quasi-twofold axis.
Time-resolved electron cryomicroscopy (cryoEM) and image reconstruction were performed by flash-freezing samples at 3 min, 30 min and 4 h after lowering the pH from 7.6 to 5.0 and computing sub-nanometre reconstructions. An additional sample was incubated for two weeks at pH 5.0 (fully mature) and a sub-nanometre reconstruction computed. Difference maps were computed between the reconstructions at each time point and for the fully mature particle at grid points surrounding the cleavage sites (known from the X-ray model). Assuming that large differences corresponded to subunits that had not cleaved and small differences to those that had cleaved, it was clear that the A and D subunits cleaved first, B was slower and C was the slowest (Matsui et al., 2010). Employing the same data, but in an entirely different way, it was shown that regions around the cleavage site for the A and D subunits had the least variance, while the same regions had the greatest variance for B and C over the ensemble of particles at the 3 and 30 min time points, implying that the cleavage site had formed for A and D and was still in the process of forming for B and C (Wang et al., 2013).
Two roles were demonstrated for the cleavage. First, maturation is not reversible in wild-type NWV (Canady et al., 2001). However, mutating Asn570 to Thr and Glu103 to Gln inhibits cleavage and the maturation reorganization is reversible when the pH is raised from 5 to 7.6 (Taylor et al., 2002). It was shown that cleavage allows residues 571–644 of the D subunit to form a molecular chock properly, while these residues are disordered at pH 5 when cleavage has not occurred (Tang et al., 2009, 2014). Secondly, it was shown that cleavage is required for particle interactions with liposomes and the associated formation of pores in artificial membranes (Domitrovic et al., 2012). Such lytic activity has been found in all non-enveloped viruses studied and is associated with a `fusion-like' peptide essential for infectivity (Banerjee & Johnson, 2008). While residues 571–644 in D subunits have a clear structural role in stabilizing the particle, some of the same residues in A subunits form a helical bundle (571–595 helical and 596–644 invisible) at the pentamer axes and are poised for release with the correct environmental cue (Helgstrand et al., 2004; Domitrovic et al., 2012). Rapid cleaving of A and D provides early structural stability and the lytic activity essential for infectivity.
3.3. Future directions
Maturation of NWV provides an excellent opportunity to follow a large-scale reorganization of a virus particle in a frame-by-frame manner by carefully controlling the pH and doing high-resolution cryoEM reconstructions at the pH intervals. The availability of direct electron detectors makes it likely that intermediate structures can be determined at 4 Å resolution or better.
4. Expanding our knowledge of the protein universe: modeling protein structures by homology
4.1. Protein structure homology modeling
Computational modeling and prediction of three-dimensional macromolecular structures and complexes from their sequence has been a long-standing goal in computational structural biology. As a result of the data deluge generated by large-scale sequencing efforts, the number of amino-acid sequences in public databases such as UniProt (UniProt Consortium, 2014) has been rising exponentially, outgrowing the number of experimental structures deposited in the PDB at the same time by orders of magnitude. Fortunately, most of the increase in complexity observed in new sequencing data is not due to the discovery of new protein domain families, but to permutations of domains which have previously been observed in other proteins (Levitt, 2009). Therefore, computational approaches for modeling proteins using comparative methods (homology modeling) have become an important tool for extrapolating the available experimental structure information to new protein sequences without direct structure information (Baker & Sali, 2001). Methods for structure modeling and prediction have made substantial progress over the last few decades, and template-based homology modeling techniques have matured to stable and reliable pipelines which are now routinely used to complement experimental techniques. More than 20 years ago, SWISS-MODEL pioneered the field by providing the first fully automated structure modeling service on the internet (Biasini et al., 2014; Guex et al., 2009; Peitsch, 1995). Today, a broad variety of structure modeling services are available publicly (Hildebrand et al., 2009; Pieper et al., 2014; McGuffin & Roche, 2011; Raman et al., 2009; Zhang, 2014). The Protein Model Portal (Arnold et al., 2009) of the SBKB (Gabanyi et al., 2011) aims to offer a `one-stop shop' for structure information, both models and experimental structures.
Over the last two decades, we have observed a paradigm shift in structural biology, starting from a situation where a large `knowledge gap' between a huge number of protein sequences contrasted with a relatively small number of experimentally known structures often impeded the systematic use of structural information in biomedical research (Baker & Sali, 2001; Schwede et al., 2000). Over the last few years, experimental structures have been solved for a significant fraction of all protein families, and today some form of structural information – either experimental or computational – is available for the majority of amino acids encoded by common model organism proteomes (Schwede, 2013). Not surprisingly, computational structure models are used routinely in a broad spectrum of biomedical applications (Schwede et al., 2009).
4.2. Assessment of homology modeling methods: CASP and CAMEO
Unfortunately, computational modeling and prediction techniques often fall short in accuracy compared with high-resolution experimental structures, and it is often difficult to convey the expected accuracy and structural variability of a specific model. Retrospectively assessing the outcome of blind structure predictions in comparison with experimental reference structures allows one to benchmark the state-of-the-art and identify areas which need further development. The critical assessment of structure prediction (CASP) experiment has, for the last 20 years, assessed progress in the field of protein structure modeling based on predictions for ca 100 blind prediction targets per experiment, which are carefully evaluated by human experts (Moult et al., 2014; Moult, 2005). The continuous model evaluation (CAMEO) project (Haas et al., 2013) aims to provide a fully automated blind assessment for prediction servers, based on weekly pre-released sequences of the PDB. CAMEO has been made possible by the development of novel scoring methods, such as the local distance difference test lDDT (Mariani et al., 2013) or CAD score (Olechnovič et al., 2013), which are robust against domain movements and allow for automated continuous structure comparison without human intervention.
One important outcome of these analyses is that the quality differences observed between methods are negligible compared with the differences in accuracy between easy and hard prediction targets (Huang et al., 2014; Mariani et al., 2011). Reliable estimates of the quality for individual models are therefore crucial to define the range of applications for which a specific model is likely to be suitable (Schwede et al., 2009). Validation methods which can estimate the local quality of models on an absolute scale are required, and various approaches have been developed by the modeling community. Their performance can be evaluated independently by the mechanisms of CASP (Kryshtafovych et al., 2014) and CAMEO (Haas et al., 2013). While single-model methods, e.g. based on statistical potentials, are able to assess individual models (Ray et al., 2012; Benkert et al., 2011; Wiederstein & Sippl, 2007), they are in general not as accurate as consensus-based approaches (Skwark & Elofsson, 2013). However, these methods require an ensemble of independent models to be provided. Quasi single-model methods overcome this limitation by creating a model ensemble `on the fly' so that, from a user perspective, the assessment of a single model becomes possible (Roche et al., 2014).
4.3. Future directions
While comparative modeling methods have made substantial progress over the few last decades, significant challenges still exist and these are the target of active research in the modeling community, such as modeling oligomeric states and complexes (Biasini et al., 2014; Shapovalov et al., 2014), modeling the binding sites of functionally relevant ligands and cofactors (Gallo Cassarino et al., 2014), refining models closer to the native structure (Nugent et al., 2014) or predicting the substrate specificity of enzymes (Tian et al., 2013).
5. Conformation-independent structural comparison of macromolecules with ProSMART
Comparative structural analyses are often performed in order to identify particular residues or regions that may be important for global or local fold stability or biological function, allowing the investigation of potential functional relationships and evolutionary links. The identification and exploration of (dis)similarities between macromolecular structures can help to provide biological insight, for instance when visualizing or quantifying a protein's response to ligand binding. Obtaining a residue alignment between compared structures is generally a prerequisite for such comparative analysis.
There have been various approaches developed for the alignment and comparison of macromolecules, some of which require global spatial rigidity, whereas others permit more flexibility, allowing alignment in the presence of domain motion [see e.g. Krissinel (2012) or Ye & Godzik (2003), to name but two; for a more detailed overview, see Nicholls (2011)]. Traditionally, the structural alignment problem has often been considered analogous to that of fold recognition, which exacerbates the commonly perceived ambiguity between the terms `alignment' and `superposition'. However, if the conformational difference between the compared structures is dramatic or complex, conventional alignment methods may struggle to provide an intuitive solution for straightforward analysis.
Indeed, it can often be hard to identify or quantify subtle differences between models, especially when attempting to do so by simply superposing structures and inspecting them manually. This can be even more challenging when the compared models cannot be easily or unambiguously superposed, such as when the models undergo conformational change, which may be due to effects that are biologically relevant such as binding, or due to environmental factors such as crystal packing. However, this task can be made dramatically easier by investigating the conservation of local structure, which can provide great insight. Whilst there are many alignment tools that optimize a superposition, there has been a need for methods that compare macromolecular structures in a way that is independent of the global conformations of the compared models.
There are often distinct measurable structural differences between highly homologous crystallographically determined macromolecular models. Such differences may occur at both global and local levels, and may be due to biologically relevant factors or to the influences of crystal content and/or packing. Equally, it is often of relevance to analyze the structural variability of model ensembles achieved using other experimental or theoretical methods, such as e.g. due to molecular binding), domain distortion (e.g. due to crystal packing) and more dramatic conformational changes (e.g. domain swaps, alternative folds). At the local level, differences include changes in backbone and side-chain conformation, which may be subtle or dramatic, and which may or may not be of particular biological interest. Generally, identifying both regions that are and those that are not locally conserved can provide useful information during a comparative analysis. Such information cannot be easily inferred using a simple superposition, and thus is often masked when using traditional representations. As such, the development of techniques dedicated to this task has been required, and this demand motivated the development of ProSMART.
NMR spectroscopy and simulations. At the global level, structural differences include domain motion (5.1. ProSMART structural comparison
The conformation-independent structural comparison tool ProSMART (Procrustes Structural Matching Alignment and Restraints Tool) is designed to allow fast but detailed comparative analysis of macromolecular structures in the presence of conformational changes. ProSMART is suited to the analysis of the structural conservation of the local backbone and side chains in a wide variety of scenarios. The approach is sensitive enough to allow the identification of subtle dissimilarities between structures sharing a high sequence homology, whilst being versatile enough to scale to the identification of surprising local similarities between more distantly related structures.
ProSMART aligns contiguous backbone fragments using a dynamic programming algorithm, and subsequently compares the matched structures in order to analyze local structural conservation of the compared macromolecular models (for details, see Nicholls et al., 2014). Being primarily interested in the conservation of local backbone structure, the initial alignment stage is completely independent of spatial relationships. However, following alignment, the spatial relationships of matched backbone fragments are analyzed in order to identify the presence of rigid substructures. Specifically, the conformation-independent fragment alignment is utilized in identifying clusters of aligned fragment pairs that belong to the same coordinate frame (for details, see Nicholls, 2011). Such clusters may correspond to rigid structural units, e.g. domains, and are used to superpose separately each identified shared Subsequently, the angular differences between the substructures are identified, allowing differences in global conformation (e.g. due to domain motion) to be described using an axis-angle representation. This method greatly contrasts with conventional r.m.s.d.-based approaches; the resulting superposition is not based on the whole domain, but rather on the notion of the substructure's average coordinate frame, allowing a tighter superposition of the substructure's core.
ProSMART allows structural comparisons to be performed at a chosen level of structural resolution (note that this does not refer to crystallographic resolution, but rather to the level of structural detail), since the backbone fragment length may be selected as desired. Performing the analysis at varying levels of structural resolution can provide useful and complementary insight regarding conformational differences between the compared models, allowing the extraction of a rich breadth of information that may be used to examine the nature of any observed (dis)similarities more closely. For example, choosing a short fragment length (three to five residues) results in performing analyses at a high level of structural resolution, which could be useful for the highly sensitive analysis of local backbone curvature in hinge regions. In contrast, choosing a long fragment length (more than nine residues) would operate closer to the secondary structure level, smoothing out any finer details and providing a more stable lower-resolution view, whilst being more affected by larger conformational differences between the compared structures. A default analysis would typically be performed using intermediate fragment lengths (seven to nine residues), offering a reasonable trade off between sensitivity, stability and conformation independence.
The comparative analysis features of ProSMART can be useful in a wide variety of scenarios, providing the ability to analyze structures at varying levels of detail. For example, near-identical models may be compared at a very high level of detail, investigating subtle differences between corresponding backbone regions or side chains. This could be used to investigate the influence of different environmental conditions (e.g. different ligand binding modes, different crystal contacts etc.) or to assess the extent of the change a model undergoes during the crystallographic model building and process (see Fig. 4). Comparative structural analysis at more moderate levels of detail may be performed on highly homologous structures, often those which adopt slightly or substantially different global conformational states. The evaluation of such conformational changes may involve the identification of residues of interest, a description of any hinging motions and an assessment of internal surface loop variability. At a lower level of detail, the backbone scores provided by ProSMART are able to distinguish between varying levels of local dissimilarity, irrespective of the overall similarity between the compared structures. In practice, this can be useful for the identification of local similarities between seemingly dissimilar structures and the visualization of local dissimilarities in corresponding regions of homologous structures, noting that chains exhibiting the same global fold but no conservation of local structure cannot be meaningfully compared in this way (other than to clarify that local structure is not conserved). In addition, ProSMART can be used to assess the degree of local structural dissimilarity over multiple homologous models.
5.2. Presentation of results
ProSMART reports various residue-based local dissimilarity scores pertaining to the conservation of backbone and side-chain conformation, which can be used in concert to analyze the local structural environments of the residues (see Fig. 4). Scores that relate to the raw structural dissimilarity of the residues' immediate local backbone environments help to identify whether structural regions are internally near-identical, irrespective of whether or not the compared models adopt dramatically different global conformations. The degree of rotational hinging of the backbone about each residue is also reported; this measure is highly sensitive to any backbone curvature or torsion, allowing the identification of any regions that exhibit subtle backbone deformation. In addition, ProSMART provides measures of the structural conservation of side chains relative to their local coordinate frames. This functionality may be used to compare close homologues, whether in the same or different global conformational states, allowing the immediate location of side chains that adopt similar or different conformations in the compared models. This can be useful in various situations, e.g. if the user wishes to investigate and visualize differences in side-chain conformation at sites of interest, or study the effects of external influences such as small-molecule and metal binding, biological assembly and crystal packing.
The provision of various residue-based local dissimilarity scores for the backbone and side chains, and the ability to view results intuitively in color using the molecular graphics software CCP4mg (McNicholas et al., 2011) and PyMOL (Schrödinger, 2010), provides a unique and informative way of performing comparative structural analyses. Residues are colored using an intuitive gradient (colors and gradient scales may be chosen) representing various levels of dissimilarity. This default output can provide useful information that may be hard to achieve manually, and at the same time easily produce quality graphical representations of structural analyses. In particular, the ProSMART interface within CCP4mg offers useful functionalities, including the ability to alter colors and gradients in real time. ProSMART is available as a stand-alone package, as well as being distributed as part of the CCP4 suite (Winn et al., 2011), and can currently be executed either as a command-line tool, through the CCP4i GUI (Potterton et al., 2003) or via CCP4mg.
5.3. Application of ProSMART in macromolecular crystallographic refinement
In addition to being used for comparative structural analysis, ProSMART is also used for the generation of external interatomic distance restraints for use in low-resolution macromolecular crystallographic by REFMAC5 (Murshudov et al., 2011) and in real-space by Coot (Emsley et al., 2010). The adopted alignment approach is considered appropriate for this application since the generated restraints operate locally, being independent of global conformational differences between the target and reference structures (Nicholls et al., 2012). The structural comparison and restraint generation features of ProSMART can also be used to aid the of macromolecular models into cryoEM maps (Brown et al., 2015).
Regularizers are used to stabilize macromolecular crystallographic ProSMART are typically short (2.5–4.2 Å), stabilizing local structure whilst allowing global conformational flexibility between target and reference structures. External restraints output by ProSMART can be visualized, analyzed and edited in Coot (see Fig. 4).
and to ensure consistency between the derived models and available prior knowledge. At low resolution, a weak signal, noisy data and a poor observation-to-parameter ratio often cause unstable with a higher risk of over-fitting, and ultimately result in an unreliable model. Such complications during can be lessened by the introduction of additional regularizers such as external restraints. These restraints are designed to utilize structural information as a source of prior knowledge, helping local interatomic distances to agree with previous observation without inappropriately enforcing global rigidity. Such structural information may be derived from homologous models where available, even if in a different global conformational state or from a different crystal form. Otherwise, more generic types of information can be utilized, such as knowledge of hydrogen-bonding patterns or the typical conformations of secondary-structure elements and other structural fragments. External restraints generated byChallenges when using external restraints include the determination of suitable reference structures and ensuring robustness to inappropriate restraints. The structural analysis features of ProSMART are intended to aid such assessment, allowing quantitative and visual analysis of localized differences between related structures. These features are useful for comparing target and reference structures, and for investigating the extent of any local backbone and side-chain structural changes that may occur during the model building and process. Indeed, the comparative structural analysis features of ProSMART can be useful during crystallographic allowing comparison of the model at various stages in the model building and process, including the quick visual identification of subtle differences between non-crystallographic symmetry-related chains. Such information can be used to gain intuition regarding stability during the suitability of different protocols and the degree of influence of any external restraints used. This can be useful in honing the process, also allowing quick and easy identification of regions likely to be in drastic need of manual intervention.
5.4. Discussion
The fact that crystallographically derived models have errors is often overlooked when performing structural analyses. It is important to remember that, whilst atomic coordinate data are static, macromolecules are actually dynamic in nature. Note that models are averaged over the range of conformations present in a heterogeneous crystal, which comprises a practically infinite ensemble of structures. This is reflected by positional uncertainty (parameterized as B factors) and, in the case of more extreme flexibility, missing atoms (disorder). Furthermore, model reliability may vary; some models may exhibit substantial incorrect regions, depending on data quality, crystallographic resolution and the presence of modeling errors. Consequently, it should be acknowledged that the usefulness and limitations of structural comparison are dependent on the quality of the compared models. Whilst we often assume a reasonable degree of experimental reliability and accuracy, the potential for model errors should not be overlooked. Indeed, some deposited models have been found to be incorrect (Bujnicki et al., 2002; Chang, 2007), and even those that are considered correct cannot be considered perfect, as suggested by the improvements observed from the re-refinement of deposited models (Joosten et al., 2009). There might be a temptation to account for model uncertainty when attempting to perform structural analyses, e.g. by weighting coordinates according to a measure of positional uncertainty. However, such an approach would fail to account for the correlated motion of close atoms, resulting in a measure of positional uncertainty relative to the coordinate frame of the and not necessarily a measure of local conformational flexibility (as would be required for local analyses). With this in mind, it should be noted that model reliability should be considered (e.g. by inspection of the electron density) when performing structural analyses, remembering that the result of a structural comparison is simply a narrative, requiring a succinct contextual interpretation in order to be meaningful. It worth remembering that the static models under consideration are not flawless; experimentally derived models have errors and are in fact imperfect averaged snapshots of a dynamic structure. Whilst thermal parameters are often available (whether or not they are reliable), such a description is often a gross simplification of the actual system and does not capture information regarding the true conformational variability.
Because of the ever-increasing number of structures (and thus information) in the PDB available for exploitation, as time progresses there will be an increasing need for the provision of tools that allow easy navigation and extraction of relevant information. It seems reasonable that, at some point, the number of new structures or folds discovered will diminish, and the amount of truly unique structural information available will begin to saturate (Chothia, 1992). At such a point, the main challenge encountered by structural biologists may shift from experimental to navigation of data and extraction of information. This would heighten the necessity for effective and varied methods of comparative structural analysis. However, it would also require the ability to assess data quality so that subsequent interpretation is meaningful; whilst it is possible to infer information from data, the ability to gain knowledge is inherently limited by the validity of such information.
Structural comparison tools such as ProSMART can help break up the complexity that accompanies the constantly growing pool of structural data into a more readily accessible form, potentially offering biological insight, influencing subsequent experiments or injecting prior knowledge in order to aid The development of complementary approaches for optimizing the usefulness of database resources, aiding the extraction of useful information, will undoubtedly become even more relevant in future.
6. The LabDB laboratory information management system
6.1. Overview
The LabDB laboratory information management system (LIMS) tracks, organizes and analyzes data for structure–function studies: chemical and solution management, protein production, crystallization, diffraction, structure solution, and in vitro biochemical and biophysical experiments. The system comprises multiple components specialized for different tasks (Fig. 5). Most of these components are accessed through a dynamic web-based interface (the LabDB GUI), though other stand-alone programs and modules also interact with the system, such as the Xtaldb system for crystallization, or the hkldb module of the HKL-3000 suite (Minor et al., 2006) for diffraction data collection and structure solution.
All of these components store the data they collect into a central PostgreSQL database, and thus all data collected by one component are made available to all the others. This is crucial given the highly interconnected nature of the different experiments in structure–function analysis. For example, the specific lot of a chemical used to prepare stock solutions for a crystallization experiment can have a major effect on whether crystallization is successful (McPherson, 1982). Similarly, details of the cloning construct and purification process [e.g. does the construct add an affinity tag and is that tag cleaved before analysis? (Majorek et al., 2014)] can significantly alter the outcomes of ligand binding assays. In this way, LabDB provides a means of analyzing the experimental aspects of structure–function studies holistically and determining bottlenecks or other points of failure.
Whenever possible, the system collects data from laboratory hardware with minimal user intervention. Devices that may connect to or import data into LabDB include crystal observation robots, liquid handling robots, systems (GE Healthcare AKTA), quantitation tools (Caliper LabChip GXII and Bio-Rad Gel Doc EZ), reverse transcriptase (RT-PCR) machines and isothermal titration (ITC) systems (MicroCal iTC-200).
6.2. Modules of the LabDB system
The Reagents component tracks laboratory chemicals, bottles and solutions. Detailed information is tracked about each chemical species, which is identified by SMILES representation (Weininger, 1988; Weininger et al., 1989). Details of individual bottles of liquid or solid chemicals are stored, along with the manufacturer, quantity, date received etc. Details of stock solutions are stored, along with the name of the preparer and the date of preparation, and are linked back to the chemical bottle or `parent' stock solution used to prepare them, such that all solutions in the laboratory have a full `audit trail' back to the manufacturing lots of the reagents used to prepare them. All chemical bottles and stock solutions are also identified by unique barcode labels.
The Reagents component also integrates with hardware to simplify the process of creating stock solutions. The LabDB interface has been optimized to be used by mobile devices such as tablets or smartphones, and the system can be configured to connect with Mettler–Toledo balances and a variety of barcode scanners and label printers. When a researcher prepares a stock solution, she or he selects the concentration and volume desired, and scans the barcode of the reagent bottle using the mobile LabDB interface. The system calculates the amount of chemical to be added to reach the selected concentration, and the researcher weighs out the reagent on the balance until the calculated amount is approximately reached. The system then reads the true amount of reagent measured and adjusts the expected final volume of the solution accordingly. After the solution has been produced, a detailed and barcoded label is printed.
The Protein Production module tracks protein cloning, expression and purification. The system is optimized for recombinant expression of single proteins in prokaryotes, but is also capable of representing more complex types of data, such as cloning and expression of protein–protein complexes or purification of proteins from natural sources. Experimental data in Protein Production are represented in a hierarchical structure: one project contains one or more clones, which have one or more expressions etc. Each step also has detailed information about when and by whom a given experiment was performed. The system is equipped to handle data either from single experiments or in bulk, as multiple experiments can be imported from spreadsheet files.
The Biochemical Assay module tracks spectrophotometric binding and kinetics, thermal shift binding, ITC and protein quantitation. These tools associate functional and structural experiments, for example for selecting likely substrates for co-crystallization and soaking experiments. In addition to storing and displaying results for `single' experiments (e.g. ITC binding curves or Michaelis–Menten plots), the tools for incorporating spectrophotometric and thermal shift results are designed to import results from 96- and 384-well plates. The thermal shift tool also parses raw data files from two types of real-time PCR systems: the Applied Biosystems 7900HT and the Bio-Rad C1000/CFX96 systems. The results are displayed graphically. For example, screening results from thermal shift assay plates are shown as a color-coded grid, where wells with greater shifts in melting temperature are shown in red and those with lesser shifts in blue.
The Xtaldb module is a stand-alone expert system for designing, tracking and analyzing the results of macromolecular crystallization experiments. Xtaldb allows for the design of either screening plates or custom optimization plates, using the sets of stock solutions prepared in the Reagents component. In the latter case the system also prepares pipetting instructions for the experimenter. The system records all observations of each drop, including images of the crystallization drops if available. The system also imports plate and screen designs and drop images from screening (Formulatrix Rock Maker and Emerald Opti-Matrix Maker) and observation (Rigaku Minstrel HT and Formulatrix Rock Imager) robotics.
In addition, LabDB is integrated with the HKL-3000 suite for diffraction data collection and structure solution through the hkldb module, which provides access to all `upstream' information about the reagents and protein purification. In HKL-3000, the diffraction and structure solution process can take advantage of this prior data, for example by identifying all compounds added to the protein preparation in the purification and crystallization process, to build a list of potential candidates for the identity of an area of unidentified density.
6.3. Reporting, analysis and future directions
Two central objectives of the LabDB LIMS are real-time reporting of the status of the experimental pipeline and the ability to perform detailed analyses of the collected data. To this end the system provides extensive data-mining and analysis tools for translating raw experimental data into useful information. For example, there are a number of `dashboards' with summary information, such as the number of experiments in each category by research or by project for a specified span of time. Each type of experiment is also fully searchable by most of the attributes of each. Xtaldb and HKL-3000 also contain tools for preparing customized reports on various aspects of the data collected. New search tools and dynamic reports continue to be developed.
LabDB is used by two high-throughput PSI:Biology centers in the USA (MCSG and NYSGRC), as well as other major NIH consortia (the Center for Structural Genomics of Infectious Diseases and the Enzyme Function Initiative), and tracks millions of experiments on tens of thousands of targets. LabDB is still under active development, and future work includes the incorporation of additional types of experiment, support for data import from additional types of laboratory instrument, and a mechanism for tracking the locations of reagents and other materials by expanding the use of barcodes and near-field communication tags.
7. Data to knowledge: the Cambridge Structural Database
7.1. Data
The Cambridge Structural Database (CSD; Allen, 2002) contains crystal structures of organic molecules, some containing a metal. Since the first structures with coordinates in the 1930s (Robertson, 1936), this resource has grown to over 700 000 molecules. These individual structures can confirm the structural identity of a particular compound, perhaps its stereochemistry, how a metal atom is coordinated or even the identity of molecular species in a revealing hydrates, other solvates and cocrystals. We can also see the geometry of specific chemical groups and the conformation of particular molecules. Intramolecular interactions, for example hydrogen bonds, can be observed.
It was recognized at the outset that a collection of molecular structures would only be of limited value, and that knowledge bases capturing the geometry and interactions of the molecules as a collection were of paramount importance. Indeed, it was with such thoughts in mind that the CSD was created. Speaking about herself and J. D. Bernal, Olga Kennard, who founded the CSD, recounted that, `We had a passionate belief that the collective use of data would lead to the discovery of new knowledge which transcends the results of individual experiments' (Kennard, 1997).
Such information was originally published in hard-copy format, in the form of rather large books (Kennard et al., 1971), but as the number of structures increased and technology allowed, electronic sharing took over.
7.2. Knowledge bases
To allow access to derived data, the Cambridge Crystallographic Data Centre developed the CSD system, which includes the knowledge base Mogul (Bruno et al., 2004). Mogul allows the user to retrieve population distributions corresponding to a wide range of structural groups. Such population distributions correlate well with calculated energy values (Allen, 2002) and are virtually instantaneous to retrieve. Unlike energy-based methods, which do not capture the behavior of all chemical groups equally well, data-led methods such as this are limited solely by the prevalence of appropriate systems in the database.
Although some supramolecular frameworks (for example metal–organic frameworks) have, to a first approximation, a single defined structure, some small organic molecules (for example drug-like molecules) have a range of accessible conformations. In such cases, the shape a molecule adopts is determined by a delicate balance between the conformational energy of the molecule, the energy it can gain from favorable interactions with neighboring molecules and the energy cost of any less-favorable interactions. Despite the fact that this must all be achieved against the backdrop of a limited range of symmetrical packing (Yao et al., 2002), cases where the geometry of a molecule is significantly different from what one would expect are very rare. As such, the range of energy minima seen in a small-molecule can be assumed to be representative of those seen in solution or when bound to a protein target.
The counterpart to this system in the area of molecular interactions is the knowledge base IsoStar (Bruno et al., 1997). This system captures the geometry of non-bonded interactions between structural groups in molecules. Although the distributions of many interaction pairs are pre-calculated, a sister program, Isogen, allows one to generate population–geometry distributions for all interactions to be generated.
Our knowledge of molecular geometry and interactions is perhaps put to most direct use in the area of pharmaceutical and agrochemical design. Numerous examples exist that refer to the optimization of molecular geometry, particularly with respect to the manipulation of torsion angles with the intent of increasing the binding potency of a molecule to its target (Brameld et al., 2008), as do many for the optimization of interactions (Bissantz et al., 2010).
7.3. Application of knowledge in software
The direct use of knowledge extracted from small-molecule structures is evident, but much use goes relatively unnoticed (Taylor, 2002). For example, in addition to use in small-molecule crystallography, the restraints used in the of both ligand and protein structures are often derived from small-molecule crystal structures (Engh & Huber, 1991). Furthermore, when exploiting these structures, for example through protein–ligand docking, small-molecule structures play a key role in the parameterization of many scoring functions (Velec et al., 2005).
As databases such as the CSD continue to grow, so does the knowledge we are able to extract from them. We are now at the stage where knowledge extracted from existing crystal structures is used in the assignment of chemical functionality to coordinates from a et al., 2008). Statistical studies of the enrichment of specific interactions in crystal structures enable us to understand just which interactions drive molecular associations (Taylor, 2014) and, combined with our understanding of molecular conformations, this is bringing us closer to the point whereby we can predict the very crystal structures themselves (Bardwell et al., 2011; Kazantsev et al., 2011).
(Macrae8. Conclusions
Like other modern areas of science, structural biology faces enormous challenges created by the vast amount of data generated every day by research groups. Only rarely are raw data exported from the research laboratory. Rather, the results of data analysis (information) are published, in the form of research papers, and depositions of models and reduced data in various repositories. The deposition of these models and reduced data is often required by the journals and/or funding agencies, but is sometimes treated as a nuisance by researchers. For this reason the contents of different repositories are not always consistent with one another, and sometimes are not even self-consistent in themselves, making the analysis of data in aggregate very difficult.
In many cases, there are no suitable repositories or databases for raw data at all. For example, while the models and processed structure factors produced in macromolecular X-ray crystallography experiments may be submitted to the PDB, there is no corresponding repository for the diffraction images, even though these images comprise the primary data collected. The advantages of preserving such data are numerous: they provide the ability to verify models, to assess data quality better and to produce better models in the future when methodological improvements are made. All of these advantages make it possible to improve systematically the structural data contained within the PDB, which would in turn aid further
and bioinformatics work.The ripple effect of suboptimal information is frequently underestimated by individual depositors and very difficult to measure. Quite often, the software necessary to extract useful information is complicated, difficult to use and more costly than the instruments that generate data. There is hope that the implementation of `Big Data' tools may partly cure the present situation. However, tools, techniques and technologies that effectively support data harvesting, data mining, computations and the sharing of data with collaborators (i.e. that make data available in a straightforward way) are very difficult to develop and require a much greater investment than simply assembling massive computational clusters with petabyte cloud storage. The creation of a smooth path from data to knowledge will require a group of talented individuals, together with creativity and long-term vision on the part of their leaders. Last but not least, these groups will need significant resources to develop tools that effectively address issues related to the non-reproducibility of experimental results and to implement the systems necessary to pave the data-to-knowledge road.
Footnotes
‡These authors gave a presentation on this topic at the 23rd Congress and General Assembly of the IUCr and are listed alphabetically.
Acknowledgements
The authors acknowledge individuals from their laboratories and research teams for their expertise and support, in particular L. Chen, A. Kouranov, R. Lowe, D. Micallef, E. Peisach, R. Shah and Y.-P. Tao at Rutgers University; K. Arnold, L. Bordoli, J. Haas, F. Kiefer and S. Roth at the Biozentrum University of Basel and the SIB-Swiss Institute for Bioinformatics; P. Emsley, F. Long and A. Thorn at the Medical Research Council (MRC) Laboratory of Molecular Biology; S. McNicholas at the University of York; P. Adams, L. Carter and L. Gifford at Lawrence Berkeley National Laboratory; M. Grabowski, H. Zheng, I. Shabalin and K. Langner at the University of Virginia; J. Flippen-Anderson and R. Sala at BioSync/Rutgers; M. Fischer at the University of California San Francisco; S. White, C. Snider and G. Dasgupta at the University of California Irvine; and the CCP4 Core Team at STFC Rutherford Appleton Laboratory. HB, TS, WM and MG are funded by award U01GM093324 from the National Institute of General Medical Sciences (NIGMS) of the National Institutes of Health (NIH). MDZ and WM are funded by grant Nos. U54GM093342, U54GM094585, R01GM053163 and U54GM094662 from the NIGMS, and under contract No. HHSN272201200026C with the National Institute of Allergy and Infectious Diseases (NIAID) of the NIH. RN and GNM are funded by grant No. MC_US A025_0102 from the MRC. The remaining authors are funded by the NIH and NSF.
References
Allen, F. H. (2002). Acta Cryst. B58, 380–388. Web of Science CrossRef CAS IUCr Journals Google Scholar
Arnold, K., Kiefer, F., Kopp, J., Battey, J. N., Podvinec, M., Westbrook, J. D., Berman, H. M., Bordoli, L. & Schwede, T. (2009). J. Struct. Funct. Genomics, 10, 1–8. CrossRef PubMed CAS Google Scholar
Baker, D. & Sali, A. (2001). Science, 294, 93–96. Web of Science CrossRef PubMed CAS Google Scholar
Banerjee, M. & Johnson, J. E. (2008). Curr. Protein Pept. Sci. 9, 16–27. PubMed CAS Google Scholar
Bardwell, D. A. et al. (2011). Acta Cryst. B67, 535–551. Web of Science CrossRef CAS IUCr Journals Google Scholar
Benevento, M., Di Palma, S., Snijder, J., Moyer, C. L., Reddy, V. S., Nemerow, G. R. & Heck, A. J. (2014). J. Biol. Chem. 289, 11421–11430. Web of Science CrossRef CAS PubMed Google Scholar
Benkert, P., Biasini, M. & Schwede, T. (2011). Bioinformatics, 27, 343–350. Web of Science CrossRef CAS PubMed Google Scholar
Berman, H. M., Kleywegt, G. J., Nakamura, H. & Markley, J. L. (2014). J. Comput. Aided Mol. Des. 28, 1009–1014. Web of Science CrossRef CAS PubMed Google Scholar
Biasini, M., Bienert, S., Waterhouse, A., Arnold, K., Studer, G., Schmidt, T., Kiefer, F., Cassarino, T. G., Bertoni, M., Bordoli, L. & Schwede, T. (2014). Nucleic Acids Res. 42, W252–W258. Web of Science CrossRef CAS PubMed Google Scholar
Bissantz, C., Kuhn, B. & Stahl, M. (2010). J. Med. Chem. 53, 5061–5084. Web of Science CrossRef CAS PubMed Google Scholar
Brameld, K. A., Kuhn, B., Reuter, D. C. & Stahl, M. (2008). J. Chem. Inf. Model. 48, 1–24. Web of Science CrossRef PubMed CAS Google Scholar
Brown, A., Long, F., Nicholls, R. A., Toots, J., Emsley, P. & Murshudov, G. N. (2015). Acta Cryst. D71 doi:10.1107/S1399004714021683. CrossRef Google Scholar
Bruno, I. J., Cole, J. C., Kessler, M., Luo, J., Motherwell, W. D., Purkis, L. H., Smith, B. R., Taylor, R., Cooper, R. I., Harris, S. E. & Orpen, A. G. (2004). J. Chem. Inf. Comput. Sci. 44, 2133–2144. Web of Science CrossRef PubMed CAS Google Scholar
Bruno, I. J., Cole, J. C., Lommerse, J. P., Rowland, R. S., Taylor, R. & Verdonk, M. L. (1997). J. Comput. Aided Mol. Des. 11, 525–537. Web of Science CrossRef CAS PubMed Google Scholar
Bujnicki, J. M., Feder, M., Rychlewski, L. & Fischer, D. (2002). FEBS Lett. 525, 174–175. Web of Science CrossRef PubMed CAS Google Scholar
Canady, M. A., Tihova, M., Hanzlik, T. N., Johnson, J. E. & Yeager, M. (2000). J. Mol. Biol. 299, 573–584. Web of Science CrossRef PubMed CAS Google Scholar
Canady, M., Tsuruta, H. & Johnson, J. (2001). J. Mol. Biol. 311, 803–814. Web of Science CrossRef PubMed CAS Google Scholar
Carp, J. (2013). Cogn. Affect. Behav. Neurosci. 13, 660–666. Web of Science CrossRef PubMed Google Scholar
Carrillo-Tripp, M., Shepherd, C. M., Borelli, I. A., Venkataraman, S., Lander, G., Natarajan, P., Johnson, J. E., Brooks, C. L. III & Reddy, V. S. (2009). Nucleic Acids Res. 37, D436–D442. Web of Science PubMed CAS Google Scholar
Chang, G. (2007). J. Mol. Biol. 369, 596. Web of Science CrossRef PubMed Google Scholar
Chothia, C. (1992). Nature, 357, 543–544. CrossRef PubMed CAS Web of Science Google Scholar
Collins, F. S. & Tabak, L. A. (2014). Nature, 505, 612–613. CrossRef PubMed Google Scholar
Cooper, D. R., Porebski, P. J., Chruszcz, M. & Minor, W. (2011). Expert Opin. Drug Discov. 6, 771–782. Web of Science CrossRef CAS PubMed Google Scholar
Dauter, Z., Wlodawer, A., Minor, W., Jaskolski, M. & Rupp, B. (2014). IUCrJ, 1, 179–193. CrossRef CAS PubMed IUCr Journals Google Scholar
Domagalski, M. J., Zheng, H., Zimmerman, M. D., Dauter, Z., Wlodawer, A. & Minor, W. (2014). Methods Mol. Biol. 1091, 297–314. CrossRef PubMed Google Scholar
Domitrovic, T., Matsui, T. & Johnson, J. E. (2012). J. Virol. 86, 9976–9982. Web of Science CrossRef CAS PubMed Google Scholar
Dorrington, R. A. & Short, J. R. (2010). The Insect Viruses, edited by K. Johnson and S. Asgari, pp. 283–305. New York: Academic Press. Google Scholar
Emsley, P., Lohkamp, B., Scott, W. G. & Cowtan, K. (2010). Acta Cryst. D66, 486–501. Web of Science CrossRef CAS IUCr Journals Google Scholar
Engh, R. A. & Huber, R. (1991). Acta Cryst. A47, 392–400. CrossRef CAS Web of Science IUCr Journals Google Scholar
Franzoni, C., Scellato, G. & Stephan, P. (2011). Science, 333, 702–703. Web of Science CrossRef CAS PubMed Google Scholar
Gabanyi, M. J. et al. (2011). J. Struct. Funct. Genomics, 12, 45–54. CrossRef CAS PubMed Google Scholar
Gallo Cassarino, T., Bordoli, L. & Schwede, T. (2014). Proteins, 82, Suppl. S2, 154–163. Google Scholar
Gifford, L. K., Carter, L. G., Gabanyi, M. J., Berman, H. M. & Adams, P. D. (2012). J. Struct. Funct. Genomics, 13, 57–62. CrossRef CAS PubMed Google Scholar
Guex, N., Peitsch, M. C. & Schwede, T. (2009). Electrophoresis, 30, Suppl. 1, S162–S173. Google Scholar
Haas, J., Roth, S., Arnold, K., Kiefer, F., Schmidt, T., Bordoli, L. & Schwede, T. (2013). Database J. Biol. Databases Curation, 2013, bat031. Google Scholar
Helgstrand, C., Munshi, S., Johnson, J. E. & Liljas, L. (2004). Virology, 318, 192–203. Web of Science CrossRef PubMed CAS Google Scholar
Hildebrand, A., Remmert, M., Biegert, A. & Soding, J. (2009). Proteins, 77, Suppl. S9, 128–132. Google Scholar
Huang, Y. J., Mao, B., Aramini, J. M. & Montelione, G. T. (2014). Proteins, 82, Suppl. S2, 43–56. Google Scholar
Jahandideh, S., Jaroszewski, L. & Godzik, A. (2014). Acta Cryst. D70, 627–635. Web of Science CrossRef IUCr Journals Google Scholar
Joosten, R. P., Womack, T., Vriend, G. & Bricogne, G. (2009). Acta Cryst. D65, 176–185. Web of Science CrossRef CAS IUCr Journals Google Scholar
Julfayev, E. S., McLaughlin, R. J., Tao, Y. P. & McLaughlin, W. A. (2011). J. Struct. Funct. Genomics, 12, 9–20. CrossRef CAS PubMed Google Scholar
Julfayev, E. S., McLaughlin, R. J., Tao, Y. P. & McLaughlin, W. A. (2012). J. Struct. Funct. Genomics, 13, 101–110. CrossRef CAS PubMed Google Scholar
Kazantsev, A. V., Karamertzanis, P. G., Adjiman, C. S., Pantelides, C. C., Price, S. L., Galek, P. T., Day, G. M. & Cruz-Cabeza, A. J. (2011). Int. J. Pharm. 418, 168–178. Web of Science CrossRef CAS PubMed Google Scholar
Keeler, M. R. (2006). Nothing to Hide: Privacy in the 21st Century, p. 112. Bloomington, Indiana, USA: iUniverse Inc. Google Scholar
Kennard, O. (1997). The Impact of Electronic Publishing on the Academic Community, edited by I. Butterworth, pp. 159–166. London: Portland Press Ltd. Google Scholar
Kennard, O., Watson, D. G., Allen, F. H. & Bellard, S. (1971). Molecular Structures and Dimensions. Dordrecht: Reidel. Google Scholar
Krissinel, E. (2012). J. Mol. Biochem. 1, 76–85. CAS Google Scholar
Kryshtafovych, A., Barbato, A., Fidelis, K., Monastyrskyy, B., Schwede, T. & Tramontano, A. (2014). Proteins, 82, Suppl. S2, 112–126. Google Scholar
Levitt, M. (2009). Proc. Natl Acad. Sci. USA, 106, 11079–11084. Web of Science CrossRef PubMed CAS Google Scholar
Macrae, C. F., Bruno, I. J., Chisholm, J. A., Edgington, P. R., McCabe, P., Pidcock, E., Rodriguez-Monge, L., Taylor, R., van de Streek, J. & Wood, P. A. (2008). J. Appl. Cryst. 41, 466–470. Web of Science CrossRef CAS IUCr Journals Google Scholar
Majorek, K. A., Kuhn, M. L., Chruszcz, M., Anderson, W. F. & Minor, W. (2014). Protein Sci. 23, 1359–1368. Web of Science CrossRef CAS PubMed Google Scholar
Mariani, V., Biasini, M., Barbato, A. & Schwede, T. (2013). Bioinformatics, 29, 2722–2728. Web of Science CrossRef CAS PubMed Google Scholar
Mariani, V., Kiefer, F., Schmidt, T., Haas, J. & Schwede, T. (2011). Proteins, 79, Suppl. S10, 37–58. Google Scholar
Matsui, T., Lander, G. & Johnson, J. E. (2009). J. Virol. 83, 1126–1134. Web of Science CrossRef PubMed CAS Google Scholar
Matsui, T., Lander, G. C., Khayat, R. & Johnson, J. E. (2010). Proc. Natl Acad. Sci. USA, 107, 14111–14115. Web of Science CrossRef CAS PubMed Google Scholar
Matsui, T., Tsuruta, H. & Johnson, J. E. (2010). Biophys. J. 98, 1337–1343. Web of Science CrossRef CAS PubMed Google Scholar
McGuffin, L. J. & Roche, D. B. (2011). Proteins, 79, Suppl. S10, 137–146. Google Scholar
McNicholas, S., Potterton, E., Wilson, K. S. & Noble, M. E. M. (2011). Acta Cryst. D67, 386–394. Web of Science CrossRef CAS IUCr Journals Google Scholar
McPherson, A. (1982). Preparation and Analysis of Protein Crystals. New York: John Wiley and Sons. Google Scholar
Minor, W., Cymborowski, M., Otwinowski, Z. & Chruszcz, M. (2006). Acta Cryst. D62, 859–866. Web of Science CrossRef CAS IUCr Journals Google Scholar
Moult, J. (2005). Curr. Opin. Struct. Biol. 15, 285–289. Web of Science CrossRef PubMed CAS Google Scholar
Moult, J., Fidelis, K., Kryshtafovych, A., Schwede, T. & Tramontano, A. (2014). Proteins, 82, Suppl. S2, 1–6. Google Scholar
Murshudov, G. N., Skubák, P., Lebedev, A. A., Pannu, N. S., Steiner, R. A., Nicholls, R. A., Winn, M. D., Long, F. & Vagin, A. A. (2011). Acta Cryst. D67, 355–367. Web of Science CrossRef CAS IUCr Journals Google Scholar
Nicholls, R. A. (2011). Thesis, University of York, UK. Google Scholar
Nicholls, R. A., Fischer, M., McNicholas, S. & Murshudov, G. N. (2014). Acta Cryst. D70, 2487–2499. Web of Science CrossRef IUCr Journals Google Scholar
Nicholls, R. A., Long, F. & Murshudov, G. N. (2012). Acta Cryst. D68, 404–417. Web of Science CrossRef CAS IUCr Journals Google Scholar
Nicholls, R. A., Long, F. & Murshudov, G. N. (2013). Advancing Methods for Biomolecular Crystallography. Heidelberg: Springer. Google Scholar
Nugent, T., Cozzetto, D. & Jones, D. T. (2014). Proteins, 82, Suppl. S2, 98–111. Google Scholar
Olechnovič, K., Kulberkytė, E., Venclovas, C. & Česlovas, (2013). Proteins, 81, 149–162. Google Scholar
Peitsch, M. C. (1995). Nat. Biotechnol. 13, 658–660. CrossRef CAS Web of Science Google Scholar
Pieper, U., Webb, B. M., Dong, G. Q., Schneidman-Duhovny, D., Fan, H., Kim, S. J., Khuri, N., Spill, Y. G., Weinkam, P., Hammel, M., Tainer, J. A., Nilges, M. & Sali, A. (2014). Nucleic Acids Res. 42, D336–D346. Web of Science CrossRef CAS PubMed Google Scholar
Potterton, E., Briggs, P., Turkenburg, M. & Dodson, E. (2003). Acta Cryst. D59, 1131–1137. Web of Science CrossRef CAS IUCr Journals Google Scholar
Price, W. N. II et al. (2009). Nat. Biotechnol. 27, 51–57. PubMed CAS Google Scholar
Prinz, F., Schlange, T. & Asadullah, K. (2011). Nat. Rev. Drug Discov. 10, 712. Web of Science CrossRef PubMed Google Scholar
Raman, S. et al. (2009). Proteins, 77, Suppl. S9, 89–99. Google Scholar
Ray, A., Lindahl, E. & Wallner, B. (2012). BMC Bioinformatics, 13, 224. Google Scholar
Reddy, V. S. & Nemerow, G. R. (2014). Proc. Natl Acad. Sci. USA, 111, 11715–11720. Web of Science CrossRef CAS PubMed Google Scholar
Robertson, J. M. (1936). J. Chem. Soc. p. 1195. CrossRef Google Scholar
Roche, D. B., Buenavista, M. T. & McGuffin, L. J. (2014). Methods Mol. Biol. 1137, 83–103. CrossRef PubMed Google Scholar
Schrödinger (2010). The pyMOL Molecular Graphics System. Version 1.3r1. Schrödinger LLC, New York, USA. Google Scholar
Schwede, T. (2013). Structure, 21, 1531–1540. Web of Science CrossRef CAS PubMed Google Scholar
Schwede, T., Diemand, A., Guex, N. & Peitsch, M. C. (2000). Res. Microbiol. 151, 107–112. Web of Science CrossRef PubMed CAS Google Scholar
Schwede, T. et al. (2009). Structure, 17, 151–159. Web of Science CrossRef PubMed CAS Google Scholar
Seiler, C. Y., Park, J. G., Sharma, A., Hunter, P., Surapaneni, P., Sedillo, C., Field, J., Algar, R., Price, A., Steel, J., Throop, A., Fiacco, M. & LaBaer, J. (2014). Nucleic Acids Res. 42, D1253–D1260. Web of Science CrossRef CAS PubMed Google Scholar
Shapovalov, M. V., Wang, Q., Xu, Q., Andrake, M., Dunbrack, R. L. Jr & Kurgan, L. (2014). PLoS ONE, 9, e98309. Web of Science CrossRef PubMed Google Scholar
Skwark, M. J. & Elofsson, A. (2013). Bioinformatics, 29, 1817–1818. Web of Science CrossRef CAS PubMed Google Scholar
Tang, J., Kearney, B. M., Wang, Q., Doerschuk, P. C., Baker, T. S. & Johnson, J. E. (2014). J. Mol. Recognit. 27, 230–237. Web of Science CrossRef CAS PubMed Google Scholar
Tang, J., Lee, K. K., Bothner, B., Baker, T. S., Yeager, M. & Johnson, J. E. (2009). J. Mol. Biol. 392, 803–812. Web of Science CrossRef PubMed CAS Google Scholar
Taylor, D. J., Krishna, N. K., Canady, M. A., Schneemann, A. & Johnson, J. E. (2002). J. Virol. 76, 9972–9980. Web of Science CrossRef PubMed CAS Google Scholar
Taylor, R. (2002). Acta Cryst. D58, 879–888. Web of Science CrossRef CAS IUCr Journals Google Scholar
Taylor, R. (2014). CrystEngComm, 16, 6852–6865. Web of Science CrossRef CAS Google Scholar
Tian, B., Wallrapp, F., Kalyanaraman, C., Zhao, S., Eriksson, L. A. & Jacobson, M. P. (2013). Biochemistry, 52, 5511–5513. Web of Science CrossRef CAS PubMed Google Scholar
Tomasicchio, M., Venter, P. A., Gordon, K. H., Hanzlik, T. N. & Dorrington, R. A. (2007). J. Gen. Virol. 88, 1576–1582. Web of Science CrossRef PubMed CAS Google Scholar
UniProt Consortium (2014). Nucleic Acids Res. 42, D191–D198. Web of Science CrossRef PubMed Google Scholar
Velec, H. F., Gohlke, H. & Klebe, G. (2005). J. Med. Chem. 48, 6296–6303. Web of Science CrossRef PubMed CAS Google Scholar
Wang, Q., Matsui, T., Domitrovic, T., Zheng, Y., Doerschuk, P. C. & Johnson, J. E. (2013). J. Struct. Biol. 181, 195–206. Web of Science CrossRef CAS PubMed Google Scholar
Weininger, D. (1988). J. Chem. Inf. Model. 28, 31–36. CrossRef CAS Web of Science Google Scholar
Weininger, D., Weininger, A. & Weininger, J. L. (1989). J. Chem. Inf. Model. 29, 97–101. CrossRef CAS Web of Science Google Scholar
Wiederstein, M. & Sippl, M. J. (2007). Nucleic Acids Res. 35, W407–W410. Web of Science CrossRef PubMed Google Scholar
Winn, M. D. et al. (2011). Acta Cryst. D67, 235–242. Web of Science CrossRef CAS IUCr Journals Google Scholar
Wlodawer, A., Minor, W., Dauter, Z. & Jaskolski, M. (2013). FEBS J. 280, 5705–5736. Web of Science CrossRef CAS PubMed Google Scholar
Yao, J. W., Cole, J. C., Pidcock, E., Allen, F. H., Howard, J. A. K. & Motherwell, W. D. S. (2002). Acta Cryst. B58, 640–646. Web of Science CrossRef CAS IUCr Journals Google Scholar
Ye, Y. & Godzik, A. (2003). Bioinformatics, 19, Suppl. 2, 246–255. Google Scholar
Zhang, Y. (2014). Proteins, 82, Suppl. S2, 175–187. Google Scholar
Zimmerman, M. D., Grabowski, M., Domagalski, M. J., Maclean, E. M., Chruszcz, M. & Minor, W. (2014). Methods Mol. Biol. 1140, 1–25. CrossRef PubMed Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.