An improved `substitution method' for the separation of X-ray diffraction α1α2 doublets is based on the possibility of refining both the proportionality constant between the α1 and α2 contributions to the line intensity and the doublet separation expressed in terms of the diffraction angle or of a related variable in the reciprocal space. Optimization of these two parameters, with a proper evaluation of the error, clearly shows the statistical nature of the oscillations appearing on the high-angle side of the pure α1 component after correction; their elimination by polynomial smoothing can therefore be performed and a procedure is suggested for achieving this result. A computer program, based on these principles, has been written and tested in many practical cases.