Buy article online - an online subscription or single-article purchase is required to access this article.
The crystal structure of the title compound, [Re(C8H6N4)(CO)3(H2O)]PF6·2H2O, shows the Re center to be in a distorted octahedral geometry with a facial distribution of the carbonyl ligands. Two other water molecules are hydrogen bonded to the coordinated water molecule. The cation lies on a crystallographic mirror plane, across which the anion is disordered.
Supporting information
CCDC reference: 647235
Key indicators
- Single-crystal X-ray study
- T = 293 K
- Mean (C-C) = 0.004 Å
- Disorder in solvent or counterion
- R factor = 0.016
- wR factor = 0.037
- Data-to-parameter ratio = 11.6
checkCIF/PLATON results
No syntax errors found
Alert level A
DIFF019_ALERT_1_A _diffrn_standards_number is missing
Number of standards used in measurement.
DIFF020_ALERT_1_A _diffrn_standards_interval_count and
_diffrn_standards_interval_time are missing. Number of measurements
between standards or time (min) between standards.
DIFF022_ALERT_1_A _diffrn_standards_decay_% is missing
Percentage decrease in standards intensity.
Alert level C
PLAT042_ALERT_1_C Calc. and Rep. MoietyFormula Strings Differ .... ?
PLAT125_ALERT_4_C No _symmetry_space_group_name_Hall Given ....... ?
PLAT243_ALERT_4_C High 'Solvent' Ueq as Compared to Neighbors for F3
PLAT243_ALERT_4_C High 'Solvent' Ueq as Compared to Neighbors for F4
PLAT243_ALERT_4_C High 'Solvent' Ueq as Compared to Neighbors for F6
PLAT244_ALERT_4_C Low 'Solvent' Ueq as Compared to Neighbors for P2
PLAT250_ALERT_2_C Large U3/U1 Ratio for Average U(i,j) Tensor .... 2.22
PLAT302_ALERT_4_C Anion/Solvent Disorder ......................... 33.00 Perc.
PLAT431_ALERT_2_C Short Inter HL..A Contact F6 .. O1 .. 2.98 Ang.
PLAT480_ALERT_4_C Long H...A H-Bond Reported H102 .. O1 .. 2.62 Ang.
PLAT751_ALERT_4_C Bond Calc 0.97000, Rep 0.9713(16) ...... Senseless su
O3 -H103 1.555 1.555
PLAT751_ALERT_4_C Bond Calc 0.91000, Rep 0.910(2) ...... Senseless su
O101 -H101 1.555 1.555
PLAT751_ALERT_4_C Bond Calc 0.93000, Rep 0.932(3) ...... Senseless su
O101 -H102 1.555 1.555
PLAT752_ALERT_4_C Angle Calc 117.00, Rep 117.07(15) ...... Senseless su
RE1 -O3 -H103 1.555 1.555 1.555
PLAT752_ALERT_4_C Angle Calc 97.00, Rep 97.2(2) ...... Senseless su
H101 -O101 -H102 1.555 1.555 1.555
PLAT755_ALERT_4_C D-H Calc 0.91000, Rep 0.910(2) ...... Senseless su
O101 -H101 1.555 1.555
PLAT755_ALERT_4_C D-H Calc 0.93000, Rep 0.933(3) ...... Senseless su
O101 -H102 1.555 1.555
PLAT755_ALERT_4_C D-H Calc 0.93000, Rep 0.933(3) ...... Senseless su
O101 -H102 1.555 1.555
PLAT755_ALERT_4_C D-H Calc 0.93000, Rep 0.933(3) ...... Senseless su
O101 -H102 1.555 1.555
PLAT755_ALERT_4_C D-H Calc 0.97000, Rep 0.9710(17) ...... Senseless su
O3 -H103 1.555 1.555
PLAT756_ALERT_4_C H...A Calc 1.99000, Rep 1.994(3) ...... Senseless su
H101 -N2 1.555 2.655
PLAT756_ALERT_4_C H...A Calc 2.62000, Rep 2.622(2) ...... Senseless su
H102 -O1 1.555 2.654
PLAT756_ALERT_4_C H...A Calc 1.67000, Rep 1.670(2) ...... Senseless su
H103 -O101 1.555 6.657
Alert level G
PLAT199_ALERT_1_G Check the Reported _cell_measurement_temperature 293 K
3 ALERT level A = In general: serious problem
0 ALERT level B = Potentially serious problem
23 ALERT level C = Check and explain
1 ALERT level G = General alerts; check
5 ALERT type 1 CIF construction/syntax error, inconsistent or missing data
2 ALERT type 2 Indicator that the structure model may be wrong or deficient
0 ALERT type 3 Indicator that the structure quality may be low
20 ALERT type 4 Improvement, methodology, query or suggestion
0 ALERT type 5 Informative message, check
Data collection: APEX2 (Bruker, 2006); cell refinement: APEX2; data reduction: SAINT (Bruker, 2006); program(s) used to solve structure: SHELXTL (Bruker, 2006); program(s) used to refine structure: SHELXL97 (Sheldrick, 1997); molecular graphics: SHELXTL; software used to prepare material for publication: SHELXTL.
fac-Aqua(bipyrazine)tricarbonylrhenium(I) hexafluorophosphate dihydrate
top
Crystal data top
[Re(C8H6N4)(CO)3(H2O)]PF6·2H2O | Dx = 2.258 Mg m−3 |
Mr = 627.42 | Mo Kα radiation, λ = 0.71073 Å |
Orthorhombic, Pnma | Cell parameters from 8341 reflections |
a = 15.5869 (6) Å | θ = 3.0–43.0° |
b = 13.1068 (5) Å | µ = 6.77 mm−1 |
c = 9.0349 (4) Å | T = 293 K |
V = 1845.78 (13) Å3 | Block, orange |
Z = 4 | 0.42 × 0.24 × 0.20 mm |
F(000) = 1192 | |
Data collection top
Bruker Kappa-APEXII diffractometer | 1892 independent reflections |
Radiation source: fine-focus sealed tube | 1880 reflections with I > 2σ(I) |
Graphite monochromator | Rint = 0.034 |
φ and ω scans | θmax = 26.0°, θmin = 3.5° |
Absorption correction: numerical (SADABS; Bruker, 2006) | h = −19→19 |
Tmin = 0.158, Tmax = 0.450 | k = −16→16 |
49927 measured reflections | l = −11→11 |
Refinement top
Refinement on F2 | Primary atom site location: structure-invariant direct methods |
Least-squares matrix: full | Secondary atom site location: difference Fourier map |
R[F2 > 2σ(F2)] = 0.016 | Hydrogen site location: inferred from neighbouring sites |
wR(F2) = 0.037 | H-atom parameters constrained |
S = 1.17 | w = 1/[σ2(Fo2) + (0.0071P)2 + 4.7736P] where P = (Fo2 + 2Fc2)/3 |
1892 reflections | (Δ/σ)max = 0.001 |
163 parameters | Δρmax = 0.68 e Å−3 |
0 restraints | Δρmin = −0.67 e Å−3 |
Special details top
Geometry. All e.s.d.'s (except the e.s.d. in the dihedral angle between two l.s. planes)
are estimated using the full covariance matrix. The cell e.s.d.'s are taken
into account individually in the estimation of e.s.d.'s in distances, angles
and torsion angles; correlations between e.s.d.'s in cell parameters are only
used when they are defined by crystal symmetry. An approximate (isotropic)
treatment of cell e.s.d.'s is used for estimating e.s.d.'s involving l.s.
planes. |
Refinement. Refinement of F2 against ALL reflections. The weighted R-factor
wR and goodness of fit S are based on F2, conventional
R-factors R are based on F, with F set to zero for
negative F2. The threshold expression of F2 >
σ(F2) is used only for calculating R-factors(gt) etc.
and is not relevant to the choice of reflections for refinement.
R-factors based on F2 are statistically about twice as large
as those based on F, and R- factors based on ALL data will be
even larger. |
Fractional atomic coordinates and isotropic or equivalent isotropic displacement parameters (Å2) top | x | y | z | Uiso*/Ueq | Occ. (<1) |
C1 | 0.82905 (17) | 0.1471 (2) | 0.9631 (3) | 0.0246 (6) | |
C2 | 0.7097 (3) | 0.2500 | 0.8145 (5) | 0.0273 (9) | |
C3 | 0.84846 (19) | 0.0471 (2) | 0.6279 (3) | 0.0265 (6) | |
H3 | 0.8291 | 0.0141 | 0.7126 | 0.032* | |
C4 | 0.8740 (2) | −0.0096 (2) | 0.5074 (4) | 0.0310 (7) | |
H4 | 0.8714 | −0.0803 | 0.5131 | 0.037* | |
C5 | 0.9042 (2) | 0.1350 (2) | 0.3794 (3) | 0.0294 (6) | |
H5 | 0.9235 | 0.1674 | 0.2941 | 0.035* | |
C6 | 0.87832 (17) | 0.1940 (2) | 0.4986 (3) | 0.0228 (6) | |
O1 | 0.82694 (15) | 0.08427 (18) | 1.0518 (3) | 0.0374 (5) | |
O2 | 0.6365 (2) | 0.2500 | 0.8250 (4) | 0.0411 (8) | |
O3 | 0.96933 (17) | 0.2500 | 0.7918 (3) | 0.0238 (6) | |
O101 | 0.52257 (16) | 0.06874 (17) | 0.6314 (3) | 0.0370 (5) | |
N1 | 0.85100 (14) | 0.14918 (18) | 0.6248 (3) | 0.0207 (5) | |
N2 | 0.90248 (18) | 0.0332 (2) | 0.3828 (3) | 0.0324 (6) | |
P2 | 0.63555 (8) | 0.2500 | 0.32697 (12) | 0.0302 (2) | |
F1 | 0.6022 (3) | 0.2500 | 0.1613 (4) | 0.0858 (14) | |
F2 | 0.6640 (3) | 0.2500 | 0.4909 (4) | 0.108 (2) | |
F3 | 0.5475 (4) | 0.2138 (7) | 0.3846 (7) | 0.110 (5) | 0.50 |
F4 | 0.6768 (9) | 0.1465 (6) | 0.3355 (10) | 0.126 (4) | 0.50 |
F5 | 0.5921 (6) | 0.1392 (5) | 0.3165 (7) | 0.0808 (19) | 0.50 |
F6 | 0.7203 (4) | 0.2023 (8) | 0.2657 (9) | 0.120 (5) | 0.50 |
Re1 | 0.832360 (9) | 0.2500 | 0.812157 (16) | 0.01747 (6) | |
H101 | 0.5541 | 0.0337 | 0.6992 | 0.072 (15)* | |
H102 | 0.5625 | 0.0665 | 0.5546 | 0.12 (2)* | |
H103 | 0.9995 | 0.1897 | 0.8264 | 0.048 (11)* | |
Atomic displacement parameters (Å2) top | U11 | U22 | U33 | U12 | U13 | U23 |
C1 | 0.0204 (13) | 0.0302 (15) | 0.0231 (14) | 0.0001 (11) | −0.0008 (11) | −0.0023 (12) |
C2 | 0.025 (2) | 0.032 (2) | 0.025 (2) | 0.000 | −0.0035 (17) | 0.000 |
C3 | 0.0326 (15) | 0.0201 (14) | 0.0268 (14) | −0.0033 (12) | −0.0013 (12) | 0.0007 (12) |
C4 | 0.0394 (17) | 0.0204 (14) | 0.0333 (16) | −0.0014 (13) | −0.0031 (14) | −0.0039 (12) |
C5 | 0.0386 (16) | 0.0277 (15) | 0.0220 (14) | 0.0007 (13) | 0.0012 (13) | −0.0016 (12) |
C6 | 0.0253 (13) | 0.0216 (14) | 0.0214 (13) | −0.0020 (11) | −0.0023 (11) | −0.0001 (11) |
O1 | 0.0425 (13) | 0.0387 (13) | 0.0309 (12) | 0.0003 (10) | 0.0033 (10) | 0.0149 (11) |
O2 | 0.0200 (16) | 0.061 (2) | 0.0424 (19) | 0.000 | −0.0024 (14) | 0.000 |
O3 | 0.0198 (13) | 0.0218 (14) | 0.0298 (15) | 0.000 | 0.0012 (11) | 0.000 |
O101 | 0.0499 (14) | 0.0261 (11) | 0.0351 (12) | 0.0097 (10) | −0.0081 (11) | 0.0008 (10) |
N1 | 0.0211 (11) | 0.0192 (11) | 0.0218 (11) | −0.0011 (9) | −0.0028 (9) | 0.0003 (9) |
N2 | 0.0434 (15) | 0.0254 (13) | 0.0284 (13) | 0.0031 (12) | −0.0010 (12) | −0.0084 (11) |
P2 | 0.0395 (6) | 0.0285 (6) | 0.0225 (5) | 0.000 | 0.0007 (5) | 0.000 |
F1 | 0.100 (3) | 0.127 (4) | 0.0311 (18) | 0.000 | −0.0110 (19) | 0.000 |
F2 | 0.086 (3) | 0.206 (6) | 0.033 (2) | 0.000 | −0.021 (2) | 0.000 |
F3 | 0.071 (3) | 0.194 (14) | 0.066 (3) | −0.068 (5) | 0.000 (3) | 0.062 (5) |
F4 | 0.215 (12) | 0.053 (4) | 0.109 (7) | 0.079 (6) | −0.035 (7) | −0.031 (4) |
F5 | 0.113 (6) | 0.049 (3) | 0.080 (4) | −0.023 (4) | −0.019 (4) | −0.015 (3) |
F6 | 0.057 (3) | 0.220 (15) | 0.082 (5) | 0.059 (5) | 0.007 (3) | −0.025 (6) |
Re1 | 0.01705 (8) | 0.01873 (8) | 0.01662 (8) | 0.000 | −0.00096 (5) | 0.000 |
Geometric parameters (Å, º) top
C1—O1 | 1.150 (4) | O101—H101 | 0.910 (2) |
C1—Re1 | 1.918 (3) | O101—H102 | 0.932 (3) |
C2—O2 | 1.145 (5) | N1—Re1 | 2.167 (2) |
C2—Re1 | 1.912 (4) | P2—F4i | 1.503 (6) |
C3—N1 | 1.338 (4) | P2—F4 | 1.503 (6) |
C3—C4 | 1.377 (4) | P2—F3i | 1.543 (5) |
C3—H3 | 0.930 | P2—F3 | 1.543 (5) |
C4—N2 | 1.334 (4) | P2—F2 | 1.546 (4) |
C4—H4 | 0.930 | P2—F6 | 1.563 (6) |
C5—N2 | 1.334 (4) | P2—F6i | 1.563 (6) |
C5—C6 | 1.386 (4) | P2—F1 | 1.585 (4) |
C5—H5 | 0.930 | P2—F5 | 1.606 (6) |
C6—N1 | 1.351 (4) | P2—F5i | 1.606 (6) |
C6—C6i | 1.468 (5) | Re1—C1i | 1.918 (3) |
O3—Re1 | 2.143 (3) | Re1—N1i | 2.167 (2) |
O3—H103 | 0.9713 (16) | | |
| | | |
O1—C1—Re1 | 178.9 (3) | F3—P2—F6i | 174.1 (5) |
O2—C2—Re1 | 175.9 (4) | F2—P2—F6i | 95.6 (3) |
N1—C3—C4 | 121.0 (3) | F3i—P2—F1 | 91.5 (3) |
N1—C3—H3 | 119.5 | F3—P2—F1 | 91.5 (3) |
C4—C3—H3 | 119.5 | F2—P2—F1 | 177.5 (3) |
N2—C4—C3 | 122.4 (3) | F6—P2—F1 | 86.7 (3) |
N2—C4—H4 | 118.8 | F6i—P2—F1 | 86.7 (3) |
C3—C4—H4 | 118.8 | F4i—P2—F5 | 179.4 (7) |
N2—C5—C6 | 122.3 (3) | F3i—P2—F5 | 85.6 (5) |
N2—C5—H5 | 118.9 | F6—P2—F5 | 88.5 (5) |
C6—C5—H5 | 118.9 | F4—P2—F5i | 179.4 (7) |
N1—C6—C5 | 120.3 (3) | F3—P2—F5i | 85.6 (5) |
N1—C6—C6i | 115.78 (15) | F6i—P2—F5i | 88.5 (5) |
C5—C6—C6i | 123.92 (17) | C2—Re1—C1i | 88.01 (12) |
Re1—O3—H103 | 117.07 (15) | C2—Re1—C1 | 88.01 (12) |
H101—O101—H102 | 97.2 (2) | C1i—Re1—C1 | 89.30 (17) |
C3—N1—C6 | 117.5 (3) | C2—Re1—O3 | 175.71 (15) |
C3—N1—Re1 | 126.1 (2) | C1i—Re1—O3 | 95.03 (10) |
C6—N1—Re1 | 115.85 (18) | C1—Re1—O3 | 95.03 (10) |
C4—N2—C5 | 116.5 (3) | C2—Re1—N1 | 98.20 (12) |
F4i—P2—F3i | 94.9 (6) | C1i—Re1—N1 | 170.92 (10) |
F4—P2—F3 | 94.9 (6) | C1—Re1—N1 | 97.49 (11) |
F3i—P2—F2 | 86.1 (3) | O3—Re1—N1 | 78.43 (8) |
F3—P2—F2 | 86.1 (3) | C2—Re1—N1i | 98.20 (12) |
F4i—P2—F6 | 91.0 (8) | C1i—Re1—N1i | 97.49 (11) |
F3i—P2—F6 | 174.1 (5) | C1—Re1—N1i | 170.92 (10) |
F2—P2—F6 | 95.6 (3) | O3—Re1—N1i | 78.43 (8) |
F4—P2—F6i | 91.0 (8) | N1—Re1—N1i | 75.14 (12) |
Symmetry code: (i) x, −y+1/2, z. |
Hydrogen-bond geometry (Å, º) top
D—H···A | D—H | H···A | D···A | D—H···A |
O101—H101···N2ii | 0.910 (2) | 1.994 (3) | 2.882 (4) | 164.83 (18) |
O101—H102···F5 | 0.933 (3) | 2.395 (7) | 3.180 (8) | 141.7 (3) |
O101—H102···F3 | 0.933 (3) | 2.475 (7) | 2.955 (7) | 112.1 (2) |
O101—H102···O1iii | 0.933 (3) | 2.622 (2) | 3.168 (3) | 117.99 (15) |
O3—H103···O101iv | 0.9710 (17) | 1.670 (2) | 2.611 (3) | 161.87 (17) |
Symmetry codes: (ii) −x+3/2, −y, z+1/2; (iii) −x+3/2, −y, z−1/2; (iv) x+1/2, y, −z+3/2. |
Re—O and O···O distances (Å) topCompound | Re—O | O···O |
(I) | 2.143 (3) | 2.611 (3) |
(II) | 2.190 | 2.623 |
(III) | 2.181 | |
Subscribe to Acta Crystallographica Section E: Crystallographic Communications
The full text of this article is available to subscribers to the journal.
If you have already registered and are using a computer listed in your registration details, please email
support@iucr.org for assistance.