short communications
SPring-8 twin helical undulator
aSPring-8, Kamigori-cho, Ako-gun, Hyogo-ken 678-12, Japan
*Correspondence e-mail: toru@spring8.or.jp
There are several ways of producing circularly polarized light, such as using asymmetric devices, crossed undulators etc. The SPring-8 helical undulator introduces a simple way of producing both horizontal and vertical fields in one undulator. All the magnet arrays are arranged above and below the plane of the electron orbit, so there is no limitation of access from the sides of the undulator. For the SPring-8 BL25SU, two helical undulators will be installed in tandem, and the helicity of the polarization can be switched at up to 10 Hz using five kicker magnets.
Keywords: undulators; helical undulators; helicity switching.
1. Introduction
The SPring-8 BL25SU is being constructed for experiments in soft et al., 1998). For these experiments, a twin helical undulator system, consisting of two out-of-vacuum helical undulators and five kicker magnets, will be installed in a 5 m straight section.
of solids, including photoelectron holography (PEH), magnetic circular and linear dichroisms in angular distribution (MCDAD and MLDAD) and spin-resolved photoemission (SaitoIn the soft X-ray region, the heat load of the undulator radiation becomes a serious issue because of the high K value. However, for a helical undulator, the on-axis radiation contains only fundamental radiation: all higher harmonics are off-axis. Thus, most of the heat load is off-axis, and can be absorbed at the front end. Fig. 1 compares the on-axis radiation of the helical and linear undulators.
There is a large demand for fast switching of the helicity of polarization. At SPring-8, five kicker magnets make two local orbit bumps and switch the helicity at up to 10 Hz.
2. SPring-8 helical undulator
The magnet configuration of the SPring-8 helical undulator is sketched in Fig. 2. There are six magnet arrays: two centre arrays produce a vertical field like conventional planar undulators, while four side arrays, which are on the same planes as the centre ones, give a horizontal field. Thus there is no limitation of the access to the undulator from the sides. By shifting the two centre arrays, the phase between the horizontal and vertical fields is changed, and both linear and circular polarizations can be obtained. When the phase is set to +π/2 or −π/2, the electrons follow a spiral orbit in the undulator, and thus the radiation field has a circular polarization.
In order to assure complete circular polarization, the centre and side magnet blocks (centre block width = 24 mm, side block width = 40 mm) are designed so that the vertical and horizontal K values (Kx, Ky) are equal for any undulator gap. The gap dependence of Ky and Kx is plotted in Fig. 3. To enlarge the flat top of the vertical magnetic field, the middle of the centre magnet block is carved.
Magnetic field corrections are carried out independently for the horizontal and vertical fields by inserting small magnet chips on the back of the magnet holders. The end effect of the undulator is cancelled by the same end-magnet configuration employed for the SPring-8 in-vacuum undulators (Hara et al., 1998). The surface of the magnet blocks is also coated with 5 µm of TiN to prevent oxidation. The residual field integral error will be corrected by two steering coils at the entrance and the exit of the undulator.
The main parameters of the SPring-8 helical undulator are given in Table 1. The minimum undulator gap is designed to be 20 mm, which corresponds to 120 eV fundamental radiation. However, the height of the slot at the bending magnet, which is used for the extraction of the undulator radiation, presently limits the maximum K value to 3 and the minimum gap to 30 mm.
|
3. Helicity switching of the circularly polarized light
There seems to be three common techniques for switching the helicity of undulator radition: by using electromagnetic devices, by moving the magnet array mechanically, or by changing the electron beam orbit at the undulator. At SPring-8, we use five kicker magnets to make and switch two local orbit bumps of the electron beam (orbits A and B in Fig. 4). For helicity switching purposes, the two helical undulators are set to the left- and right-handed circular polarizations, respectively. When the electron beam follows orbit A, the radiation from the first undulator travels off-axis and is stopped at the front-end absorber, whereas the radiation from the second undulator is on the beamline axis and passes through to the experimental station. For orbit B, the situation is reversed. Thus, by switching these two orbits, the circularly polarized light of alternate helicities is emitted on the optical axis of the beamline.
The kick angle, θ (300 µrad in Fig. 4), should be large enough to separate two undulator beams. Fig. 5 shows the angular distribution of the power density from one helical undulator. At the moment, the lowest photon energy is limited to 500 eV, so 300 µrad is sufficient. One notes that the optics must endure the heat load of the peak power during the transition time of switching. However, the kicker magnets are driven by a quasi-square wave, and the transition time will be less than 10 ms, so the crossing power is rather small if averaged. The switching frequency is limited to 10 Hz due to the capacity of the power source for the kickers.
Concerning the periodic beam displacement around the ring excited by the helicity switching kickers, the residual magnetic field integral of the five kickers should always be zero. To realize this, kicker magnets may be connected in series to prevent the time lag and fluctuation of the individual power source output.
4. Summary
For dichroism experiments, there is a demand for fast helicity switching of circularly polarized light. For the SPring-8 BL25SU, two helical undulators, having a simple magnet configuration, and five kicker magnets will be installed. This twin helical undulator system can realize helicity switching of the circularly polarized light at up to 10 Hz.
References
Hara, T., Tanaka, T., Tanabe, T., Mare´chal, X.-M., Okada, S. & Kitamura, H. (1998). J. Synchrotron Rad. 5, 403–405. Web of Science CrossRef CAS IUCr Journals
Saito, Y., Nakatani, T., Matsushita, T., Mayahara, T., Fujisawa, M., Soda, K., Muro, T., Ueda, S., Harada, H., Sekiyama, A., Imada, S., Daimon, H. & Suga, S. (1998). J. Synchrotron Rad. 5, 542–544. Web of Science CrossRef IUCr Journals
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.