short communications\(\def\hfill{\hskip 5em}\def\hfil{\hskip 3em}\def\eqno#1{\hfil {#1}}\)

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775

Imaging soft X-ray microscope at Rits Synchrotron Radiation Center

aDepartment of Physics, Ritsumeikan University, Kusatsu, Shiga 525-77, Japan, bPhysics Laboratory, Kansai Medical University, Hirakata, Osaka 573, Japan, cInstitute of Applied Physics, Tsukuba University, Tsukuba, Ibaraki 305, Japan, dCenter for X-ray Optics, Lawrence Berkeley Laboratory, Berkeley, CA 94720, USA, eInstitut für Angewandte Physik, Universität Tübingen, Auf der Morgenstelle 12, Tübingen 1, Germany, and fForschungseinrichtung Röntgenphysik, Georg-August-Universität, Geiststrasse 11, 37073 Göttingen, Germany
*Correspondence e-mail: fpc30013@sec.ritsumei.ac.jp

(Received 4 August 1997; accepted 1 December 1997)

An imaging soft X-ray microscope with zone plates has been installed at Rits SR Center (Ritsumeikan University, Kusatsu, Japan). With this microscope, specimens were set in air, which made it possible to investigate the specimens without breaking the vacuum of the microscope. The specimens can be prefocused with an optical microscope. Dry and wet biospecimens in air were observed. A new optical system was designed to improve the resolution.

1. Introduction

Soft X-ray microscopy offers observational methods for the biological and materials sciences with much higher resolution than optical microscopes and lower radiation doses compared with electron microscopes (Sayre et al., 1977[Sayre, D., Kirz, J., Feder, R., Kim, D. M. & Spiller, E. (1977). Ultramicroscopy, 2, 337-341.]).

An imaging soft X-ray microscope using synchrotron radiation and zone plates has been developed for the first time by the Göttingen University group, and is now applied to observe wet biological specimens (Rudolph et al., 1992[Rudolph, D., Schneider, G., Guttmann, P., Schmahl, G., Niemann, B. & Thieme, J. (1992). X-ray Microscopy III, edited by A. G. Michette, G. R. Morrison & C. J. Buckley, pp. 392-396. Berlin: Springer-Verlag.]; Schmahl et al., 1996[Schmahl, G., Guttmann, P., Schneider, G., Niemann, B., David, C., Wilhein, T., Thieme, J. & Rudolph, D. (1996). X-ray Microscopy IV, edited by V. V. Aristov & A. I. Erko, pp. 196-206. Moscow: Bogorodskii Pechatnik.]).

Since 1987, we have been developing an imaging soft X-ray microscope with zone plates at UVSOR BL8A [synchrotron radiation facility (750 MeV, 200 mA) at the Institute for Molecular Science, Okazaki, Japan] (Watanabe et al., 1996[Watanabe, N., Aoki, S., Shimanuki, Y., Kawasaki, K., Taniguchi, M., Anderson, E., Attwood, D., Kern, D., Shimizu, S., Nagata, H., Horikawa, Y., Mochimaru, S. & Kihara, H. (1996). J. Electron Spectrosc. Relat. Phenom. 80, 365-368.], 1997[Watanabe, N., Hirai, A., Takemoto, K., Shimanuki, Y., Taniguchi, M., Anderson, E., Attwood, D., Kern, D., Shimizu, S., Kawasaki, K., Nagata, H., Aoki, S., Nakayama, Y. & Kihara, H. (1997). X-ray Microscopy and Spectromicroscopy, edited by J. Thieme, G. Schmahl, D. Rudolph & E. Umbach. Heidelberg: Springer-Verlag.]). In April 1996, this microscope was transferred to Rits SR Center BL-12 (Hirai et al., 1997[Hirai, A., Watanabe, N., Takemoto, K., Nishino, K., Anderson, E., Attwood, D., Kern, D., Shimizu, S., Nagata, H., Aoki, S., Nakayama, Y. & Kihara, H. (1997). X-ray Microscopy and Spectromicroscopy, edited by J. Thieme, G. Schmahl, D. Rudolph & E. Umbach. Heidelberg: Springer-Verlag.]). Rits SR is usually operated at an energy of 575 MeV with an initial beam current of 300 mA (Iwasaki et al., 1997[Iwasaki, H., Nakayama, Y., Ozutsumi, K., Yamamoto, Y., Tokunaga, Y., Saisho, H., Matsubara, T. & Ikeda, S. (1997). J. Synchrotron Rad. 5, 1162-1165.]). The critical wavelength of the radiation is 1.47 nm. Its beam size is 0.28 × 2.6 mm (2σ). This change of synchrotron radiation facility provided at least two advantages: firstly, we can have an exclusively used X-ray microscope station and, secondly, we can use a brighter source.

This report describes the present status of the imaging soft X-ray microscope station, some results, and a new optical system designed to improve the resolution.

2. Soft X-ray microscope station

The optical system of the imaging X-ray microscope is basically the same as that of the Göttingen X-ray microscope (Niemann et al., 1994[Niemann, B., Schneider, G., Guttmann, P., Rudolph, D. & Schmahl, G. (1994). X-ray Microscopy IV, edited by V. V. Aristov & A. I. Erko, pp. 66-75. Moscow: Bogorodskii Pechatnik.]) (Fig. 1[link]). It consists of a filter (4 µm Al + 0.1 µm SiN + 55 nm Ti), a central stop (2.4 mm diameter), a condenser zone plate (CZP1 in Table 1[link]), a pinhole (20 µm diameter), a specimen, an objective zone plate (OZP; Table 1[link]) (Anderson & Kern, 1992[Anderdon, E. & Kern, D. (1992). X-ray Microscopy III, edited by A. G. Michette, G. R. Morrison & C. J. Buckley, pp. 75-78. Berlin: Springer-Verlag.]) and a back-illuminated CCD (SITe SI502A: 512 × 512 pixels, each 24 µm × 24 µm).

Table 1
Characteristics of the zone plates

  CZP1 CZP7 OZP
Diameter (µm) 4300 9000 50
Number of zones 4300 41890 277
Outermost zone width (nm) 250 53.7 45
Zone material 0.2 µm Au 0.3 µm Ge 0.13 µm Ni
Support material 0.1 µm SiN 0.1 µm Si 0.1 µm SiN
[Figure 1]
Figure 1
Schematic diagram of the optical arrangement of the X-ray microscope system. CZP, condenser zone plate; OZP, objective zone plate; CCD, back-illuminated CCD (A, 6900 mm; B, 300 mm; C, 2.5 mm; D, 670 mm).

X-rays from the source are monochromatized and condensed at the pinhole by the CZP. Transmitted X-rays through a specimen are magnified by the OZP and are imaged on the CCD. A camera with film (Fuji Minicopy HRII) is also used as a detector.

This optical system was mounted on a bench, as shown in Fig. 2[link]. The vacuum pipe was cut into two pieces: a condenser part and an imaging part. A mirror chamber and an acoustic delay line were set upstream of the bench. The specimen cell was placed in air. SiN was used for windows to separate the vacuum from the atmospheric pressure. An optical microscope was set on the same stage with the vacuum chamber of the CZP to observe specimens at the same position as in the observation with X-rays. The CZP chamber can be moved back and forth along the optical axis with a pneumatic cylinder. The CZP chamber and an optical microscope are placed on the same moving stage. They are switched with a pneumatic cylinder.

[Figure 2]
Figure 2
Schematic diagram of the X-ray microscope system. A vacuum pipe with the CZP and an optical microscope were set on the same moving stage.

3. Results

3.1. Performance test

The optical performance was estimated using a zone plate (OZP) as a specimen. Fig. 3[link] shows an image of the zone plate at a wavelength of 3.2 nm. The observable finest zone width was 63 nm. In contrast, the observable finest zone width was 0.1 µm at a wavelength of 0.90 nm. This is probably due to low monochromaticity of illumination at wavelengths of 0.90 nm.

[Figure 3]
Figure 3
An X-ray micrograph of a zone plate at a wavelength of 3.2 nm, taken using a camera with Minicopy film (exposure time 10 min).

3.2. Observation of biospecimens

Several biospecimens, such as diatoms, crab muscular tissues, granule cell layers in rat cerebellum, and blood cells of ascidian, were observed (Hirai et al., 1997[Hirai, A., Watanabe, N., Takemoto, K., Nishino, K., Anderson, E., Attwood, D., Kern, D., Shimizu, S., Nagata, H., Aoki, S., Nakayama, Y. & Kihara, H. (1997). X-ray Microscopy and Spectromicroscopy, edited by J. Thieme, G. Schmahl, D. Rudolph & E. Umbach. Heidelberg: Springer-Verlag.]; Watanabe et al., 1996[Watanabe, N., Aoki, S., Shimanuki, Y., Kawasaki, K., Taniguchi, M., Anderson, E., Attwood, D., Kern, D., Shimizu, S., Nagata, H., Horikawa, Y., Mochimaru, S. & Kihara, H. (1996). J. Electron Spectrosc. Relat. Phenom. 80, 365-368.], 1997[Watanabe, N., Hirai, A., Takemoto, K., Shimanuki, Y., Taniguchi, M., Anderson, E., Attwood, D., Kern, D., Shimizu, S., Kawasaki, K., Nagata, H., Aoki, S., Nakayama, Y. & Kihara, H. (1997). X-ray Microscopy and Spectromicroscopy, edited by J. Thieme, G. Schmahl, D. Rudolph & E. Umbach. Heidelberg: Springer-Verlag.]). Fig. 4[link] shows an image of a diatom at a wavelength of 3.2 nm. The diatom was boiled in sulfuric acid for about 30 min to remove organic matter. The skeletons thus prepared were washed with water and air dried. A 0.5 µm width of skeleton was clearly observed.

[Figure 4]
Figure 4
An X-ray micrograph of a diatom at a wavelength of 3.2 nm, taken using a camera with Minicopy film (exposure time 10 min).

Wet biospecimens were observed by using a cell covered with thin polyimide foils (0.35 µm thick) supported by thick polyimide foils (Kapton tape) (Takemoto et al., 1997[Takemoto, K., Watanabe, N., Hirai, A., Nakayama, Y. & Kihara, H. (1997). X-ray Microscopy and Spectromicroscopy, edited by J. Thieme, G. Schmahl, D. Rudolph & E. Umbach. Heidelberg: Springer-Verlag.]).

4. New optical system

To improve the present system, we have replaced the CZP with a grazing new one (CZP7 in Table 1[link]) and inserted a plane mirror (Si, grazing incident angle 40 mrad) upstream of the CZP as a low-pass filter to cut off high energy, which protects the CZP against heat load. The CZP was fabricated at Göttingen (Schmahl et al., 1993[Schmahl, G., Rudolph, D., Niemann, B., Guttmann, P., Thieme, J., Schneider, G., David, C., Diehl, M. & Wilhein, T. (1993). Optik, 93, 95-102.]), where the groove efficiency was measured as 7.5% at a wavelength of 2.5 nm.

In this system, the monochromaticity (λ/Δλ) was calculated to be 200 at a wavelength of 3.3 nm with the source of 0.28 × 2.6 mm (2σ) in the central region of the source image of 6 × 30 µm at a distance of 7.05 m (Fig. 5[link]) (B. Niemann, private communication). This will improve the spacial resolution of the X-ray microscope drastically.

[Figure 5]
Figure 5
Monochromaticity (λ/Δλ) of the new optical system at a wavelength of 3.3 nm.

5. Conclusions

We have been constructing an imaging soft X-ray microscopy system with zone plates. A 63 nm line and space pattern was resolved at a wavelength of 3.2 nm, whereas a 0.1 µm line and space pattern was resolved at a wavelength of 0.90 nm. Dry and wet biospecimens, such as diatoms, crab muscular tissues, granule cell layers in rat cerebellum, and blood cells of ascidian, in atmospheric pressure, were observed.

A new optical system has also been designed and set up to improve the resolution.

Acknowledgements

The authors are grateful for the help and encouragement from Mr Y. Yamamoto, Dr Y. Tokunaga and other staff of Ritsumeikan University. We also thank Mr Y. Shimanuki of Tsurumi University.

References

First citationAnderdon, E. & Kern, D. (1992). X-ray Microscopy III, edited by A. G. Michette, G. R. Morrison & C. J. Buckley, pp. 75–78. Berlin: Springer-Verlag.
First citationHirai, A., Watanabe, N., Takemoto, K., Nishino, K., Anderson, E., Attwood, D., Kern, D., Shimizu, S., Nagata, H., Aoki, S., Nakayama, Y. & Kihara, H. (1997). X-ray Microscopy and Spectromicroscopy, edited by J. Thieme, G. Schmahl, D. Rudolph & E. Umbach. Heidelberg: Springer-Verlag.
First citationIwasaki, H., Nakayama, Y., Ozutsumi, K., Yamamoto, Y., Tokunaga, Y., Saisho, H., Matsubara, T. & Ikeda, S. (1997). J. Synchrotron Rad. 5, 1162–1165. Web of Science CrossRef IUCr Journals
First citationNiemann, B., Schneider, G., Guttmann, P., Rudolph, D. & Schmahl, G. (1994). X-ray Microscopy IV, edited by V. V. Aristov & A. I. Erko, pp. 66–75. Moscow: Bogorodskii Pechatnik.
First citationRudolph, D., Schneider, G., Guttmann, P., Schmahl, G., Niemann, B. & Thieme, J. (1992). X-ray Microscopy III, edited by A. G. Michette, G. R. Morrison & C. J. Buckley, pp. 392–396. Berlin: Springer-Verlag.
First citationSayre, D., Kirz, J., Feder, R., Kim, D. M. & Spiller, E. (1977). Ultramicroscopy, 2, 337–341. CrossRef CAS PubMed
First citationSchmahl, G., Guttmann, P., Schneider, G., Niemann, B., David, C., Wilhein, T., Thieme, J. & Rudolph, D. (1996). X-ray Microscopy IV, edited by V. V. Aristov & A. I. Erko, pp. 196–206. Moscow: Bogorodskii Pechatnik.
First citationSchmahl, G., Rudolph, D., Niemann, B., Guttmann, P., Thieme, J., Schneider, G., David, C., Diehl, M. & Wilhein, T. (1993). Optik, 93, 95–102.  CAS
First citationTakemoto, K., Watanabe, N., Hirai, A., Nakayama, Y. & Kihara, H. (1997). X-ray Microscopy and Spectromicroscopy, edited by J. Thieme, G. Schmahl, D. Rudolph & E. Umbach. Heidelberg: Springer-Verlag.
First citationWatanabe, N., Aoki, S., Shimanuki, Y., Kawasaki, K., Taniguchi, M., Anderson, E., Attwood, D., Kern, D., Shimizu, S., Nagata, H., Horikawa, Y., Mochimaru, S. & Kihara, H. (1996). J. Electron Spectrosc. Relat. Phenom. 80, 365–368.  CrossRef CAS Web of Science
First citationWatanabe, N., Hirai, A., Takemoto, K., Shimanuki, Y., Taniguchi, M., Anderson, E., Attwood, D., Kern, D., Shimizu, S., Kawasaki, K., Nagata, H., Aoki, S., Nakayama, Y. & Kihara, H. (1997). X-ray Microscopy and Spectromicroscopy, edited by J. Thieme, G. Schmahl, D. Rudolph & E. Umbach. Heidelberg: Springer-Verlag.

© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds