short communications
in the high-energy region
aJAERI-RIKEN SPring-8 Project Team, Kamigori, Ako-gun, Hyogo 678-12, Japan, bFaculty of Science, Okayama University, Okayama 700, Japan, and cThe Institute of Scientific and Industrial Research, Osaka University, Ibaraki, Osaka 567, Japan
*Correspondence e-mail: yasuon@spring8.or.jp
K-absorption edges of Ce (40.5 keV), Dy (53.8 keV), Ta (67.4 keV) and Pt (78.4 keV). The blunt K-edge jump due to the finite lifetime of the core hole was observed. This makes it difficult to extract (extended X-ray absorption fine-structure) functions at low k values. Local structure parameters can be evaluated from the spectra above K-absorption edges in the high-energy region as well as from those above LIII-edges. It was found that the finite-lifetime effect of the core hole is effectively taken into the photoelectron mean-free-path term, as predicted theoretically.
(X-ray absorption fine-structure) spectra were measured nearKeywords: X-ray absorption fine-structure (XAFS); extended X-ray fine-structure (EXAFS); structure parameters.
1. Introduction
The K-absorption edges for almost all elements. spectra near LIII-absorption edges have been measured for heavy elements. Although the initial p state can go to final states of s or d symmetry, as an approximation the matrix element of a transition to an l = 0 final state is usually ignored in comparison with that of the transition to an l = 2 final state. (extended X-ray absorption fine-structure) signals above most LIII-absorption edges are restricted to several hundred electron-volts owing to the LII-absorption edge. On the other hand, there are no such assumptions and restrictions for spectra above K-absorption edges. The higher an edge energy is, the easier it is to prepare a sample of uniform thickness for precise analysis, since X-rays penetrate into thick samples in the high-energy region. However, it has been theoretically pointed out that the finite lifetime of a core hole smears out oscillation, and that this effect becomes more serious for K-absorption edges of heavier elements (Stearns, 1984).
from a bending magnet at the SPring-8 storage ring shows sufficient photon density to observe qualitative (X-ray absorption fine-structure) spectra, even at 100 keV. This advantage makes it possible to measure spectra nearHere we report K-edges of Ce (40.5 keV), Dy (53.8 keV), Ta (67.4 keV) and Pt (78.4 keV), which were measured at the Photon Factory in the National Laboratory of High Energy Physics (KEK-PF). Local structure parameters were evaluated from spectra above these K-edges and they were compared with those evaluated from spectra above the LIII-edges. We discuss the effect of the lifetime broadening on the mean-free-path term of photoelectrons in the function.
spectra observed near2. Experimental and analysis
We measured X-ray absorption spectra near K-edges of Ce (CeO2), Dy (foil), Ta (KTaO3 and foil) and Pt (foil). They were measured at beamline BL14A at KEK-PF with a vertical wiggler. Measurements were carried out at room temperature in transmission mode with an Si(553) double-crystal monochromator. The incident and transmitted X-ray intensities, I0 and I, were monitored with a flowing Kr-gas 17 cm long and a flowing Xe-gas 31 cm long, respectively. We also measured X-ray absorption spectra of LIII-edges of these samples for comparison, using an facility installed at beamline BL10B of KEK-PF. Measurements were carried out in transmission mode with an Si(311) channel-cut monochromator. The X-ray intensities were monitored with ionization chambers. The flowing gases were carefully chosen to minimize counting of the higher-order harmonics.
The energy resolution of the double-crystal monochromator in the parallel position is mainly determined by the divergence of the incident X-ray beam. The resolutions of Ce, Dy, Ta and Pt K-edges were estimated to be 13, 24, 37 and 50 eV, respectively, from the size of the X-ray source (1.05 mm), the width of the horizontal slit at 30 m from the centre of the vertical wiggler (1.0 mm) and the rocking curve of the monochromator crystal. The low energy resolution makes it difficult to evaluate the correct signal especially at low k values. We did not succeed in the deconvolution of the X-ray intensities, I0 and I, with the energy resolution function, so we avoided analysis of the signal in the low-k region.
The programmes XAFS93 and MBF93 (Maeda, 1987) were employed for the data analysis to determine local structure parameters. We used an formula for the harmonic model based on single-scattering theory and expressed by the cumulant expansion (Ishii, 1992)
where Nj is the in the jth shell at distance Rj from the absorbing atom, |fj(k,π)| is the back-scattering amplitude of photoelectrons and ψj(k) is the theoretical value of the phase shift (McKale et al., 1988). The quantity σj(2) corresponds to the Debye–Waller factor. The wavenumber of a photoelectron is represented as , where m and are the mass of an electron and Planck's constant, respectively. The E0 was assigned to an inflection point of the The λj, of the photoelectron was taken to depend on the wavevector k with the relationship λj = k/ηj. The function χ(k) was normalized using MacMaster coefficients. A Fourier-filtered function concerning the first peak in real space was compared with a theoretical function. In the parameter fitting, the theoretical function was filtered in the same way as the observed one in order to eliminate truncation effects through the Fourier transformation of data. We used a non-linear least-squares fitting method to determine the local structure parameters.
3. Results and discussion
Fig. 1(a) shows the X-ray near the Pt K-edge of Pt foil. The edge-jump of the Pt K-edge is not as sharp as that of the Pt LIII-edge shown in Fig. 2(a). The signal above the Pt K-edge seems to smear out. As shown in Fig. 1(b), however, the signal is defined well up to 18 Å−1. The amplitude of the function of the K-edge is considerably smaller than that of the Pt LIII-edge shown in Fig. 2(b). The width of an edge-jump is dependent on the width of the initial state of the K-level, ΓK. The blunt edge-jump at the Pt K-edge makes it difficult to extract the signal at low k values. In Fig. 3 the Fourier-filtered function concerning the first nearest neighbour of the Pt K-edge is compared with that of the Pt LIII-edge. It shows clearly the phase difference of π. Table 1 gives local structure parameters of Pt and also those of the other materials. Here, R is the interatomic distance and ΔR is the difference between the interatomic distance R and that determined by X-ray diffraction. The N was fixed. Local structure parameters calculated from the spectrum of the LIII-edges are also tabulated. The interatomic distance and the Debye–Waller factor obtained for K-edges are in good agreement with those obtained for LIII-edges, with the exception of the parameters of the η.
|
As Stearns (1984) pointed out, an signal is theoretically generally reduced due to the short lifetime of a K-hole. This smearing effect behaves in a similar manner to the mean free-path term when the amplitudes and phases are assumed to be slowly varying functions of energy. The is principally modified as follows,
Since the λ = k/η), we can rewrite the above equation
depends on the wavenumber (The influence of the finite lifetime of the core hole can be effectively taken together into η in the function. Thus η is a good variable to examine the finite lifetime of the core hole. The large values of η for K-edges imply a short of the photoelectron. Since both the backscattering amplitude and total phase functions are monotonically decreasing functions for light atoms, the assumption described above is valid for CeO2 and KTaO3. On the other hand, since the backscattering amplitude and phase functions have peaks or valleys at the low-k region for heavy atoms, we carried out the fitting calculation using the data at the high-k region (>10 Å−1) for Ta and Pt foils. Unfortunately, we had to use the data for the Dy K-edge at low k values because the signal-to-noise ratio was not good for the Dy foil. As shown in Fig. 3, the phase of the function of the Pt K-edge swerves slightly from that of the LIII-edge at low k values, suggesting that the influence of the finite lifetime on the complicated back-scattering amplitude and phase functions cannot be neglected in the lower-k region. The ΔE0 for the fitting calculation seems to be large, as given in Table 1, because the finite lifetime effect is not considered for the theoretical values (McKale et al., 1988). Fig. 4 shows the difference between the mean-free-path terms, Δη = ηK−ηLIII (closed circles), estimated by the fitting analysis, as a function of the K-edge energy. Open circles represent values of Δ(mΓ/2) = (mΓK/2) — (mΓLIII/2 where the Γ values were taken from the literature (Krause & Oliver, 1979). The difference is an estimate of the increase in the finite lifetime effect due to the K-edge. The energy dependence of the photoelectron mean free-path term is qualitatively consistent with that of the finite lifetime of the core hole. The estimation of η depends on the range of k for the fitting calculation mainly because the low energy resolution of the monochromator reduces the amplitude of the signal in the low-k region. For example, Δη of Ta K-edge estimated from KTaO3 is smaller than that estimated from Ta foil. The high-brilliance X-rays from the SPring-8 storage ring enables us to obtain spectra with higher energy resolution; energy resolution as good as 7 eV at the Pt K-edge is expected.
4. Conclusions
We have measured preliminary K-edges of several samples in the energy region 40–80 keV. The blunt edge-jump makes it difficult to extract an function correctly at low k values. The fitting calculation was carried out under the condition that the finite lifetime of the core hole mainly affects only the photoelectron mean-free-path term. It was found that the value of the mean-free-path term roughly corresponds to the theoretically estimated value; the mean-free-path term of the K-edge, ηK, is larger than that of the LIII-edge, ηLIII. Local structure parameters (with the exception of the mean-free-path term) estimated from spectra above the K-edge are in good agreement with those estimated from spectra above the LIII-edge. An study in the high-energy region at SPring-8 is scheduled in order to investigate the finite lifetime effect of the core hole.
spectra near theAcknowledgements
The authors would like to thank Dr S. Kishimoto for his kind assistance in the experiment at KEK-PF.
References
Ishii, T. (1992). J. Phys. Condens. Matter, 4, 8029–8034. CrossRef Web of Science
Krause, M. O. & Oliver, J. H. (1979). J. Phys. Chem. Ref. Data, 8, 329–338. CrossRef CAS
McKale, A. G., Veal, B. W., Paulikas, A. P., Chan, S. K. & Knapp, G. S. (1988). J. Am. Chem. Soc. 110, 3763–3768. CrossRef CAS Web of Science
Maeda, H. (1987). J. Phys. Soc. Jpn. 56, 2777–2787. CrossRef CAS Web of Science
Stearns, D. G. (1984). Philos. Mag. B, 49, 541–558. CrossRef CAS Web of Science
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.