short communications
Time-resolved fluorescent X-ray interference
aAdvanced Research Laboratory, Hitachi Ltd, Hatoyama, Saitama, Japan, bJapan Synchrotron Radiation Research Institute (JASRI), SPring-8, Kamigori, Hyogo, Japan, cCentral Research Laboratory, Hitachi Ltd, Higashi-koigakubo, Kokubunji-shi, Japan, and dResearch Institute for Scientific Measurements, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai, Japan
*Correspondence e-mail: ycsasaki@harl.hitachi.co.jp
A fluorescent X-ray interference method can effectively measure nanometer-level conformational changes for non-crystallized molecules and proteins in aqueous conditions. The time-resolved technique can be used to obtain information about the dynamics of molecules and proteins. Instrumentation for time-resolved fluorescent X-ray interference has been designed. A typical interference-fringe pattern was observed with approximately 3 s of X-ray exposure time from K-fluorescent X-rays emitted from a Zn monoatomic layer on an Rh substrate. The primary X-ray beam was polychromed with a mirror for total external reflection of X-rays and was tuned to an energy level at which only Zn K radiation became optimally excited. The glancing angle of the primary X-ray beam was fixed at a glancing angle at which the total intensity of K-fluorescent X-rays emitted from Zn atoms corresponded to the maximum value. The fluorescent X-ray interference fringes were monitored with an imaging plate (IP) as a non-energy-dispersive two-dimensional detector. The exposed interference fringes on the IP were integrated along the direction of the fringes. The integrated fringes were in close agreement with a theoretical estimate based on the interference among transmitted and reflected waves at interfaces in the sample.
Keywords: time-resolved technique; fluorescent X-ray interference; polychromatic primary beam; imaging plates.
1. Introduction
Time-resolved observations of conformational changes in functional protein molecules and membranes are important to the understanding of biological phenomena. The functional activities of biomolecules are maintained under limited aqueous environments. The fluorescent X-ray interference (FXI) method can effectively measure nanometer-level structural information about non-crystallized proteins in the appropriate aqueous conditions (Sasaki et al., 1994). Information obtained from our FXI method is similar to that from X-ray standing waves (XSW). In a conventional XSW technique, essentially monochromatic X-rays are used as a primary probe (Bedzyk et al., 1989). Polychromatic X-rays derived from synchrotron radiation can be used in FXI experiments because fluorescent X-ray radiation occurs independently of the primary X-ray beam. Although the incident angle of the primary X-ray beam is a parameter in the XSW technique, the glancing angle for the primary beam is fixed during the X-ray exposure time in FXI experiments. The pattern of the observed fluorescent X-ray interference fringes can be obtained without scanning the incident angles.
In addition, the intensity of the observed two-dimensional fluorescent X-ray patterns can be integrated along the fringe direction because the observed fluorescent X-rays show patterns similar to those of Young's fringes (Sasaki et al., 1993). The designed time-resolved FXI technique thus offers advantages for the recording of fluorescent X-ray interference fringes from a short-lived bimolecular complex during biochemical reactions.
2. Theory
We used the Lloyd's mirror-type interference effect on monochromatic X-rays from fluorescent X-ray emitting atoms embedded in a non-crystalline material, as shown in Fig. 1 (Born & Wolf, 1980). X-ray emissions from atoms located above a substrate surface can take two optical paths: direct emission and totally reflected emission when the take-off angle (θt) is smaller than the critical angle (θc) for total external reflection of the observed fluorescent X-rays. The coherent sources are the primary source S1, which is the fluorescent X-ray atom above the substrate surface, and its virtual image S2, as shown in Fig. 1. The optical path difference, Δ, between the two sources depends on the distance (z) of the fluorescent X-ray emitting atom from the substrate and the phase shift that occurs with X-ray total external reflection on the substrate surface. The geometrical path difference is described as Δ = 2zsinθt. Thus, positional information on the emitting atoms can be obtained from the period of the observed interference fringes.
This interference of fluorescent X-rays is considered to be a time-inverse phenomenon of XSW experiments, and can also be regarded as a special case of X-ray holographic microscopy using a local reference beam. This three-dimensional local-beam holography is considered to be a powerful technique for determining the atomic scale position of neighbouring atoms (Tegze & Faigel, 1996). The FXI technique can be applied to the analysis of one-dimensional nanometer-level structures. If the arrangement of adsorbed biomolecules is controlled on the substrate surface, we can obtain three-dimensional information about the adsorbed biomolecules from the FXI experiments.
The theoretical interference pattern from X-ray emissions can be calculated for a characteristic matrix of stratified media on the basis of reciprocity. In other words, the calculation of the characteristic z for take-off angle θt is identical to that of the incident X-ray field at coordinate z for glancing angle θt. Although X-ray emissions from atoms have a spherical waveform, a plane wave was observed under the conditions maintained for this experiment. This is because the distance between the observation point and the atomic source points is very long. Thus, the observed wave can be regarded as a plane wave which is a component of a spherical wave.
from coordinateWhen radioactive atoms act as characteristic X-ray sources with distribution N, the yield Y is given by
where I(θt, z) is the intensity of the characteristic X-rays resulting from the interference effects between the direct and totally reflected emissions from coordinate z at the take-off angle, θt. Ed and Er are E-field plane waves for the direct and reflected emissions, and N(z) is the atom distribution at distance z from the substrate surface.
3. Experiment
The experimental set-up is shown in Fig. 2. This experiment was carried out at the BL-8C2 experimental station on the KEK Photon Factory 2.5 GeV storage ring (Hirai et al., 1993). The stored current was between 300 and 350 mA. Synchrotron radiation was used for the polychromatic X-ray source. The mirror for the X-ray total external reflection was quartz substrate and the filter used was made of aluminium foil. The primary polychromatic X-ray beam was tuned to an energy level at which the observed fluorescent X-rays became optimally excited. The beam was reflected at the glancing angle at which the total intensity of the fluorescent X-ray was maximized. The exposed area for the sample was 5 × 35 mm. The output beam from the synchrotron radiation was monitored by using an The incident X-ray beam of the sample was narrowed to 100 µm (V) × 5 mm (H) by slits. Incident radiation was linearly polarized, and the electrical vector was in the horizontal plane. Fluorescent radiation was measured at a 90° scattering angle in the horizontal plane to minimize background signals caused by elastic scattering.
In this experiment, the FXI fringes were monitored with a non-energy-dispersive two-dimensional detector (IP, BAS-5000, Fuji Film Co.; a wide-area detector) and by scanning the slit with an energy-dispersive detector (a pure-Ge detector). The time-resolved FXI technique needs a two-dimensional detector to observe the overall structure of the interference fringes and to integrate the intensity of the fluorescent X-rays along the direction of the fringes. In addition, we use polychromatic X-rays derived from synchrotron radiation to increase the intensity of the observed fluorescent X-rays in this experiment. In general, fluorescent X-rays excited using polychromatic X-rays emit twin fluorescent X-rays, for example, Kα and Kβ radiation or Lα and Lβ radiation. The monitored FXI pattern will thus be from a mixture of these radiations when we use an IP which is a non-energy-dispersive two-dimensional detector. The dimensions of the IP are 20 × 25 mm, and the pixel size of the IP is 25 µm. A flat cassette with a sample-to-IP distance of 300 mm can be mounted on the camera. The IP cassette was driven horizontally directly by the stepping motor, whose position was monitored by a linear sensor. The maximum speed of the stepping motor is 40 mm s−1. The IP was read out by a BAS-5000 system (Fuji Film Co.). The IP camera was designed to have the slit [5 mm (V) × 20 mm (H)] restricting the exposure area of the IP and to allow the vertical translation of the IP cassette for continuous measurement. The IP cassette is covered with a 6 mm-thick Pb shield box to suppress background signals. The intensity of the IP between −3 and 0 mrad take-off angle was defined as the background level necessary for subtracting the background radiation. The linearity of the IP was confirmed for Cu Kβ and Mo Kα (Miyahara et al., 1986).
The IP has no energy selectivity. Thus, a Ge detector was used as a fluorescent X-ray detector to compare the experimental results with the theoretical ones. A 20 µm (V) × 12 mm (H) slit was used to determine the take-off angle for the fluorescent X-rays and was placed in front of the detector at a distance of 90 mm from the sample. The angular distribution of the fluorescent X-rays was measured by scanning the slit along the transversal direction. This arrangement enabled us to measure an angular resolution of less than 0.3 mrad below θt for 8 mrad.
Fig. 3(a) shows a cross-sectional view of the sample. To separate atoms from the substrate a low-density layer that contained source atoms was deposited on a high-density substrate. We used an evaporated Si thin film (= 27.0 nm) on an Au substrate and a Zn arachidate as a source layer for the fluorescent X-rays. z was estimated at about 29.8 nm (see §4). The thickness of the Zn arachidate bilayer was 5.5 nm, measured by X-ray diffraction.
4. Analysis and discussion
The FXI fringes from a Zn monolayer measured with the IP are shown in Fig. 3(a). These measurements were repeated 30 times for one IP. Each exposure time was 3 s. The output data from the IP reader system were linearly amplified and converted into digital signals. It was easy to treat the output data from the IP; for example, integration along some direction and magnification. The four clear interference fringes were revealed under magnification, as shown in Fig. 3(b).
We used rhodium as the substrate, which can emit fluorescent X-rays of L radiation (λ = 0.061 and 0.055 nm). In this experiment, the fluorescent X-rays from the Rh substrate were not emitted because we tuned the energy level of the polychromatic primary X-ray beam without decreasing the intensity of Zn K radiation. For instance, when we used Au and Pt substrates, which had optically mirrored surfaces as well as the Rh substrate to reflect the fluorescent X-rays (Yanagihara et al., 1992), the Au and Pt substrates emitted fluorescent X-rays of L radiation (λAu Lα = 0.128 nm and λPt Lα = 0.131 nm) very close to that of the K radiation (λZn Kα = 0.144 nm) from Zn atoms. Thus, the fluorescent X-rays from both the Zn monolayer and the Au or Pt substrate were spontaneously emitted with the polychromatic primary beam. In this time-resolved FXI system, we confirmed that it is difficult to observe clear fringes on the IP with substrates of Au and Pt. To monitor the clear FXI patterns with both an IP and a polychromatic primary beam, the sample substrate should offer the following features: (i) a high-density medium and an optically flat mirror to reflect X-ray radiation; (ii) no X-ray emission from the sample except for the desired fluorescent X-rays.
To obtain the exact structural information for the sample, we calculated the theoretical interference fringes by using a χ2 minimization fitting to the experimental results measured with a pure-Ge detector. We assumed that a fluorescent X-ray source had a distribution expressed by N(z), a Gaussian distribution with a standard deviation (2σ) of δz, and that it reached a maximum peak at z = zp. In the theoretical FXI pattern, we modelled the four homogeneous media, namely air, the LB film containing the monolayer of the Zn arachidate, the evaporated Si thin film and the Rh substrate, as stratified media. From the χ2 minimization fitting we obtained a mean Zn position of zp = 29.8 ± 0.3 nm and a width of δz (2σ) = 1.4 ± 0.2 nm. These values showed 63.8% data accuracy. The FXI pattern from a pure-Ge detector is in close agreement with the theoretical one.
The sum of the FXI pattern along the fringe direction in the IP (Fig. 3b) is shown in Fig. 4. The number of photons per pixel on the IP was calibrated using the observed fluorescent X-ray using a pure-Ge detector with a rectangular slit [20 µm (V) × 12 mm (H)].
We confirmed that two fluorescent X-rays (Zn Kα and Zn Kβ) were emitted from the sample in this experiment. To analyse the FXI patterns from the IP data which consist of the mixed fringes from Zn Kα and Zn Kβ, we measured the intensity ratio Zn Kα/Zn Kβ (= 5.5) with a pure-Ge detector. We assumed that the IP has approximately the same sensitivity for Zn Kα lines as for Zn Kβ lines. In the next calculation, we used the optical indices parameters of the above calculation except for those of zp and δz (2σ). Fig. 4 shows the theoretical mixed FXI pattern, which is in close agreement with the observed FXI pattern from the IP. From the χ2 minimization fitting, we obtained a mean Zn position of zp = 29.6 ± 1.0 nm and a width of δz (2σ) = 4.0 ± 0.8 nm. These values show 63.8% data accuracy. The structural information from the IP is in close agreement with the theoretical data. This result shows that we can analyse the monitored FXI pattern from the two-dimensional non-energy-dispersive detector as the mixed FXI pattern of Kα and Kβ lines.
5. Conclusions
We observed fluorescent X-ray interference fringes from the Zn monolayer on the Rh surface with less than 3 s of exposure time. The time-resolved (high-speed) FXI technique comprises the following elements: (i) a polychromatic primary X-ray beam generated from synchrotron radiation; (ii) no X-ray emission from the sample except for the desired fluorescent X-rays under the restricted conditions of X-ray excitation; (iii) high resolution and two-dimensional detector system to integrate along the fringe direction.
The time-resolved FXI technique can be used to observe vertical conformational changes of a biomolecular system, such as molecular recognition between the ligand and the binding protein, the folding processes of protein molecules, and dynamic movement of a membrane. To obtain accurate three-dimensional information about the structure of biomolecules with the time-resolved FXI technique, the arrangement of the biomolecules should be controlled on the substrate surface. Recently, many scientists have succeeded in controlling the arrangement of an organic thin film on a substrate surface.
References
Bedzyk, M. J., Bommarito, G. M. & Schildkraut, J. S. (1989). Phys. Rev. Lett. 62, 1376–1379. CrossRef PubMed CAS Web of Science
Born, M. & Wolf, E. (1980). Principles of Optics, 6th ed. New York: Pergamon.
Hirai, Y., Waki, I., Hayakawa, K., Kuroishi, K., Yasaka, Y., Kanaya, N., Satow, Y. & Sato, S. (1993). Nucl. Instrum. Methods, A327, 256–264. CrossRef CAS Web of Science
Miyahara, J., Takahashi, K., Amemiya, Y., Kamiya, N. & Satow, Y. (1986). Nucl. Instrum. Methods, A246, 572–578. CrossRef CAS Web of Science
Sasaki, Y. C., Suzuki, Y. & Ishibashi, T. (1994). Science, 263, 62–64. CrossRef CAS PubMed Web of Science
Sasaki, Y. C., Suzuki, Y., Tomioka, Y. & Fukuhara, A. (1993). Phys. Rev. B, 48, 7724–7726. CrossRef CAS Web of Science
Tegze, M. & Faigel, G. (1996). Nature (London), 380, 49–51. CrossRef CAS Web of Science
Yanagihara, M., Maehara, T., Yamamoto, M. & Namioka, T. (1992). Proc. SPIE, 1720, 246–251. CrossRef CAS
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.