short communications
Commissioning and Operation of the First Brazilian Synchrotron Light Source
aNational Synchrotron Light Laboratory/CNPq, Caixa Postal 6192, 13083-970 Campinas, SP, Brazil, bInstitute of Physics, University of São Paulo, São Carlos, SP, Brazil, cInstitute of Physics, University of São Paulo, São Paulo, SP, Brazil, and dInstitute of Physics, University of Campinas, Campinas, SP, Brazil
*Correspondence e-mail: cylon@lnls.br
The synchrotron light source designed and constructed at the LNLS is composed of a 1.37 GeV electron storage ring and a 120 MeV linac for low-energy injection. The storage ring has been commissioned and has already reached the designed electron-beam energy, current and emittance. The electron lifetime is now 6 h at 60 mA, and is steadily increasing. Seven beamlines (TGM, SGM, SXS,
XRD, SAXS, PCr) have been constructed in parallel with the electron accelerators and are at present in operation. Beam time was allocated to 129 approved research projects for the second semester of 1997. A number of them are currently under way.Keywords: synchrotron light source; beamlines; commissioning.
1. The LNLS synchrotron light source
The National Synchrotron Light Laboratory (LNLS/CNPq) was established in 1987 by the Brazilian National Council for Scientific and Technological Development (CNPq) with the objective of constructing a synchrotron light source and the associated beamlines to be utilized for a wide range of scientific and technological applications.
The synchrotron source, at present in operation and open to users since 1 July 1997, is composed of a 1.37 GeV electron storage ring and a linear accelerator which injects into the ring at 120 MeV. The energy of the electrons is ramped up to the final energy inside the storage ring. Originally, the storage ring was designed for 1.15 GeV/100 mA with some allowance in the power supplies and vacuum chambers to deal with higher synchrotron light power. However, the care taken in the design and construction of the magnets proved sufficient to increase the energy to 1.37 GeV, which means twice as much synchrotron light power and 30 times more
at 10 keV.Most of the components of the synchrotron source were constructed at the LNLS, including all magnets and power supplies. Detailed descriptions of these components have been published elsewhere: magnets (Neuenschwander et al., 1997), power supplies (Wisnivesky et al., 1997), RF system (Wisnivesky & Pardini, 1997), vacuum components (Ferreira et al., 1997), interlock system (Scorzato & Rodrigues, 1997), control system (Tavares et al., 1997).
Fig. 1 shows a general view of the LNLS electron storage ring. The linac injector is located underground.
Three modes of operation of the electron storage ring have been studied. They are the high-, normal- and low-emittance modes. The main design parameters of the LNLS synchrotron source for the normal mode of operation are listed in Table 1.
|
The commissioning of the LNLS synchrotron light source started in May 1996. The full electron energy of the storage ring (1.37 GeV) was attained, with a few mA, in October 1996. The electron current at full energy has increased steadily, reaching the design value of 100 mA in July 1997. Fig. 2 shows a plot of the electron current as a function of energy during the first ramping procedure in which the design value was attained.
The experimentally measured emittance of the source is 100 nm mrad, in agreement with the design value. The electron-beam lifetime is now 6 h at 60 mA of stored current, and is steadily increasing. The vertical and horizontal positions of the beam are maintained within 20 µm using an automatic periodic correction of the orbit.
In order to increase the electron current above its design value, an upgrading of the electron linac is being considered. Modifications to raise the injection energy up to 170 MeV may be carried out during a shutdown scheduled for November–December 1997 if it proves necessary.
Fig. 3 shows the produced by the bending-magnet sources of the LNLS electron storage ring. The useful photon energy range (i.e. the range for which the is much higher than that produced by classical sources such as, for example, a rotating-anode source) extends up to Emax = 15 keV. In order to increase the photon energy range for users interested in applications of higher-energy photons (Eph > 10 keV), the insertion of superconducting wigglers in the straight sections of the ring is planned. The expected from a planned 1/2–1–1/2 wiggler (wavelength shifter), with a magnetic field of 7 T, is also plotted in Fig. 3.
2. LNLS beamline
The main technical characteristics of the first seven beamlines, now in operation at LNLS, are listed below.
(i) Toroidal-grating monochromator (TGM) (Fonseca et al., 1992). Source: bending magnet D05 (4°), σy = 0.14 mm. Monochromator: three toroidal gratings. Energy range: 300–100 eV (40–120 Å), 100–35 eV (120–360 Å), 35–12 eV (360–1000 Å). Spectral resolution: better than 0.1 Å (40–120 Å), better than 0.3 Å (120–360 Å), better than 1.1 Å (360–1000 Å). Dispersion: better than 30.2 Å deg−1. Focusing elements: two toroidal mirrors. on sample: 1013 photons s−1 (1.3 GeV at 100 mA). Spot size at sample: 2 × 5 mm. Detectors: electron energy analyser, fluorescence detector, electron time-of-flight.
(ii) Spherical-grating monochromator (SGM) (Castro et al., 1993). Source: bending magnet D08 (4°), σy = 0.10 mm. Monochromator: two spherical gratings. Focusing elements: two spherical mirrors and one toroidal mirror. Energy range: 250–1000 eV (250–1500 eV at reduced and resolution). Spectral resolution: better than 3000. Spot size at sample: 0.5 × 0.5 mm. Detectors: electron energy analyser, channeltrons, microchannel plates.
(iii) Soft X-ray spectroscopy (SXS) (Tolentino, Compagnon-Cailhol et al., 1998). Source: bending magnet D04 (4°), σy = 0.10 mm. Monochromator: double-crystal with constant offset (Correa et al., 1992). Energy range: beryl, 790–1550 eV; quartz, 1480–1800 eV; InSb, 1680–2000 eV; Si, 2050–4000 eV. Energy resolution: 0.2 eV at 800 eV (E/ΔE = 4000). Focusing element: toroidal mirror (gold-coated zerodur mirror). Detectors: total electron yield, electron energy analyser, photodiode array.
(iv) X-ray absorption fine structure (XAFS) (Tolentino, Cezar et al., 1998). Source: bending magnet D04 (15°), σy = 0.12 mm. Spot size: 550 × 700 µm. on sample: 2 × 109 photons s−1 mrad−1 at 8 keV. Monochromator: double-crystal (Correa et al., 1992) and four-crystal (Tolentino & Rodrigues, 1992) with constant offset. Energy range: Si(111) (2d = 6.271 Å), 2.010–11.390 keV; Si(220) (2d = 3.84 Å), 3.300–18.500 keV; Ge(111) (2d = 6.53 Å), 1.920–10.930 keV. (E/ΔE): 10000–100000. Focusing system: cylindrical bent mirror (gold or rhodium-coated), sagittal focusing on crystal. Detectors: ion chambers, fluorescence and electron detectors.
(v) X-ray diffraction (XRD) (Cusatis et al., 1998). Source: bending magnet D12 (4°), σy = 0.10 mm. Monochromator: double (2C) (Correa et al., 1992) and four- (4C) (Tolentino & Rodrigues, 1992) crystal with constant offset. Energy range: Si(111) (2d = 6.271 Å), 2.010–11.390 keV; Si(220) (2d = 3.84 Å), 3.300–18.500 keV; Ge(111) (2d = 6.53 Å), 1.920–10.930 keV. Energy resolution: 4 eV at 8000 eV (E/ΔE = 2000). Focusing element: sagittal focusing (10 mrad) by elastic bending of the second crystal (2C). Detectors: fast Si–Li solid-state and linear position-sensitive detector, fluorescence detector, imaging plate.
(vi) Small-angle X-ray scattering (SAXS) (Bernardes et al., 1992). Source: bending magnet D11 (4°), σy = 0.14 mm. Monochromator: one horizontally bent and asymmetrically cut silicon crystal, reflection (111), asymmetry angle 11°, condensing mode. Energy range: 6–12 keV (1–2 Å). Energy resolution (E/ΔE): 1000. Focusing element: cylindrical elastically bent mirror (vertical focusing), bent silicon crystal (horizontal focusing). Detector: one-dimensional position-sensitive gas detector, two-dimensional position-sensitive gas detector, imaging plate, scintillation monitors.
(vii) Protein crystallography (PCr) (Polikarpov et al., 1997). Source: bending magnet D3 (15°), σy = 0.12 mm. Monochromator: single horizontally bent and asymmetrically cut silicon crystal, reflection (111), asymmetry angle 7.25°, condensing mode. Energy range: 6–12 keV (1–2 Å). Energy resolution (E/ΔE): 3000. Focusing elements: cylindrical elastically bent mirror (vertical focusing), bent silicon crystal monochromator (horizontal focusing). Detector: imaging plate.
Two additional beamlines for
(XRF) studies and microfabrication (MF) are currently under construction and will be open to users in 1998.The locations around the storage ring of the beamlines mentioned above are indicated in Fig. 4. All beamlines were designed and constructed at LNLS. Some of the optical components developed at LNLS, such as two-crystal and four-crystal monochromators, use original and patented mechanical concepts (Cusatis, 1993; Tolentino & Rodrigues, 1993). A picture of one of the X-ray beamlines (SAXS) in operation is shown in Fig. 5.
3. Preliminary experimental results and status of LNLS beamlines
Preliminary experiments using LNLS beamlines had been performed by the end of October 1996. As an example of the first experimental results, an . This was obtained in the beamline using two ion chambers to record the direct and transmitted beam intensities as a function of the photon energy. The white beam was monochromatized by using the (111) Bragg reflection from a two-crystal silicon monochromator. The of Ni was determined in an energy range of 500 eV, close to the K-absorption edge. Atomic structure information is obtained by mathematical treatment of the oscillations which are apparent in Fig. 6 above the K-absorption edge.
spectrum of pure nickel is shown in Fig. 6Other recent experimental results concerning (i) XAFS studies of the atomic structure of nanocrystalline Cu–Co alloys and (ii) SAXS investigations on the crystallization process in polymers and on conformational changes of lysozyme in aqueous solutions, were reported in the XX Brazilian Meeting on Condensed Matter Physics (June 1997).
The LNLS source has been operating for about 100 h per week since 1 July 1997, with 55 h dedicated to synchrotron light users. Up to now (27 August 1997), 129 research projects have been approved by the Scientific Committee (16 from foreign countries) for the second semester of 1997. A number of them are currently under way. The distribution of approved projects among the different beamlines in operation, shown in Fig. 7, exhibits a strong concentration for the hard X-ray techniques. Experiments requiring particularly high hard X-ray will be possible when the planned superconductor wiggler is installed.
4. Conclusions
The 1.37 GeV LNLS electron storage ring is presently in operation and has been open to users since 1 July 1997. The main design parameters of the source have been achieved and the total beam time for users, scheduled for the first two months of operation (July–August 1997), was fully delivered.
In parallel to the effort of building the light source, seven beamlines were constructed and commissioned. They are now being used by the scientific staff of LNLS and by many scientists from other Brazilian and foreign research institutions.
The technical achievement related to the successful construction, commissioning and operation of the LNLS synchrotron light source, the first in the southern hemisphere, is an important milestone for Brazilian science and technology. It is expected that the use of the LNLS synchrotron source by materials scientists, biologists and researchers from many other fields will provide a significant contribution to the development effort in Brazil and Latin America.
Additional information about LNLS and on the procedure for submitting research proposals is given on the LNLS Internet home page (http://www.lnls.br/).
Acknowledgements
The authors thank the LNLS technical, administrative and scientific staff, thanks to whom this project was accomplished.
References
Bernardes, L. A., Tolentino, H., Rodrigues, A. R. D., Craievich, A. F. & Torriani, I. (1992). Rev. Sci. Instrum. 63, 1065–1067. CrossRef Web of Science
Castro, A. R. B., Fonseca, P. T., Pacheco, J. G., Verdugo, J. E., Graeff, M. S. Z. & Fraguas, G. (1993). Braz. J. Phys. 23, 53–56.
Correa, M. C., Tolentino, H., Craievich, A. F. & Cusatis, C. (1992). Rev. Sci. Instrum. 63, 896–898. CrossRef CAS Web of Science
Cusatis, C. (1993). Brazilian Patent PI 9301801–22.
Cusatis, C., Franco, M. K., Kakuno, E., Giles, C., Morelhão, S., Mello, V. & Mazzaro, I. (1998). J. Synchrotron Rad. 5, 491–493. Web of Science CrossRef CAS IUCr Journals
Ferreira, M. J., Bagnato, O. R., Ferraz, R. O., Minuzzi, F. A., Pícoli, R. & Silva, M. B. (1997). Proc. EPAC V, 3, 2518–2520.
Fonseca, P. T., Pacheco, J. G., Samogin, E. & Castro, A. R. B. (1992). Rev. Sci. Instrum. 63, 1256–1259. CrossRef Web of Science
Neuenschwander, R. T., Tosin, G., Rodrigues, A. R. D., Farias, R. H. A., Lin, L., Apfelbaum, J., Araujo, S., Leite, F. & Siqueira, E. W. (1997). Proc. EPAC V, 3, 2195–2197.
Polikarpov, I., Craievich, A. F., Oliva, G., Castellano, E. E., Garrat, R. C. & Arruda, P. (1997). Physics and Industrial Development, pp. 391–394. Singapore: World Scientific.
Scorzato, C. R. & Rodrigues, A. R. D. (1997). Proc. EPAC V, 3, 2627–2628.
Tavares, P. F., Rodrigues, A. R. D., Farias, R. H. A., Franco, G. S., Jahnel, L. C., Monteiro, G. & Pitton, J. R. (1997). Proc. EPAC V, 2, 1791–1793.
Tolentino, H. (1996). Private communication.
Tolentino, H., Cezar, J. C., Cruz, D. Z., Compagnon-Cailhol, V., Tamura, E. & Alves, M. C. M. (1998). J. Synchrotron Rad. 5, 521–523. Web of Science CrossRef CAS IUCr Journals
Tolentino, H., Compagnon-Cailhol, V., Vicentin, F. C. & Abbate, M. (1998). J. Synchrotron Rad. 5, 539–541. Web of Science CrossRef CAS IUCr Journals
Tolentino, H. & Rodrigues, A. R. D. (1992). Rev. Sci. Instrum. 63, 946–949. CrossRef CAS Web of Science
Tolentino, H. & Rodrigues, A. R. D. (1993). Brazilian Patent PI 9301047–22.
Wisnivesky, D., Lira, A. C., Silva, A. R., Arroyo, F. C. & Oliveira, L. H. (1997). Proc. EPAC V, 3, 2349–2351.
Wisnivesky, D. & Pardini, C. (1997). Proc. EPAC V, 3, 2038–2040.
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.