research papers
Quarter-Wave Plates and X-ray
on ID24 at the ESRFaLaboratoire Louis Néel, CNRS, BP 166, 38042 Grenoble CEDEX, France, bLURE, Bâtiment 209D, Centre Universitaire, 91405 Orsay CEDEX, France, cESRF, BP 220, 38043 Grenoble CEDEX, France, and dLaboratoire de Minéralogie-Cristallographie, Université Paris 6 et 7, 75252 Paris CEDEX 05, France
*Correspondence e-mail: pizzini@labs.polycnrs-gre.fr
The first XMCD measurements carried out on the ID24 energy-dispersive
beamline at the ESRF are reported. Circular-polarized X-rays are obtained using perfect diamond crystals as quarter-wave plates. The very small source divergence allows circular polarizations close to unity to be obtained.1. Introduction
X-rays with a high rate of circular polarization (Pc) are essential for X-ray which measures the difference of absorption of right- and left-handed X-rays of an element-selected ferromagnetic and relates it to the of the selected atom (Goulon et al., 1997). In first- and second-generation synchrotron radiation sources using bending-magnet devices, circular polarization (left or right) is obtained by selecting the radiation emitted above or below the synchrotron orbit plane. This configuration implies a considerable loss and a large uncertainty on the polarization rate. At third-generation sources like the ESRF, X-rays of tunable polarization can be obtained using specific insertion devices like helical undulators (Yamamoto & Kitamura, 1987; Elleaume, 1990; Sasaki, 1993).
An alternative way to tune the X-ray polarization is to use perfect crystals as phase plates. The birefringence of a perfect crystal at or close to Bragg diffraction conditions is predicted by nσ − nπ between the of the σ and π components of the incoming electric field depends on the angular departure from the Δθ. In their first conception, phase plates took advantage of the birefringence of X-rays inside the reflection profile. Since the birefringence varies rapidly with Δθ, highly collimated X-ray beams are required (Golovchenko et al., 1986).
The differencePhase plates can also be used outside the reflection profile using the `non-deviated' forward-diffracted beam. Such a set-up was first used with a thin silicon crystal and a well collimated beam (Hirano et al., 1991, 1992). The birefringence is smaller than that inside the reflection profile but its variation with Δθ is slower (Dmitrienko & Belyakov, 1980). This offers the possibility to work with divergent X-ray beams. Thanks to their low rather thick diamond phase plates can be used with this set-up. This explains the rapid development of diamond quarter-wave plates (QWP) working far from crystal reflection in Bragg (Giles et al., 1993; Giles, Malgrange, Goulon, de Bergevin, Vettier, Dartyge, Fontaine, Giorgetti & Pizzini, 1994) and Laue (Giles, Malgrange, Goulon, de Bergevin, Vettier, Dartyge, Fontaine & Pizzini, 1994) geometry.
The principles of QWP have been detailed by Giles, Malgrange, Goulon, de Bergevin, Vettier, Dartyge, Fontaine, Giorgetti & Pizzini (1994) and Giles, Malgrange, Goulon, de Bergevin, Vettier, Dartyge, Fontaine & Pizzini (1994). Only the basic concepts are summarized here. It is known that if the diffraction plane of the birefringent crystal is set at an angle Ψ with respect to the electric field of the linearly polarized X-ray beam incident on the crystal, the circular polarization rate Pc of the transmitted wave depends on the phase shift Φ between the two components Eσ and Eπ,
The transmitted beam is fully circularly polarized when Ψ = 45° and Φ = 90°. This is the QWP configuration. Far from Bragg conditions, the phase shift Φ between the σ and π components of the electric field depends on the crystal thickness and on the offset Δθ, i.e. on the angular difference between the incident angle and the centre of the diffraction profile,
where t is the beam path in the crystal, re is the classical electron radius, V is the volume of the and Fh is the of the hkl reflection.
Quarter-wave-plate conditions can therefore be obtained by turning the crystal away from the reflection profile by an angle
The angular dependence of the circular polarization rate can then be simply expressed as a function of Δθπ/2 as
For an X-ray beam with angular divergence α, the circular polarization rate deduced from (1) and (2) for a certain angular offset Δθ has to be convoluted with a Gaussian function of width α. In order to minimize the effect of the X-ray beam divergence on Pc, Δθπ/2 should be maximized so that it falls into a region where the phase shift Φ changes more slowly with Δθ. This can be obtained by increasing the crystal thickness, at the expense of transmission. It follows that light non-absorbing crystals should be used.
In the present work a 0.74 mm-thick diamond crystal was used as a phase plate on the energy-dispersive X-ray absorption beamline at the ESRF (ID24) (Hagelstein et al., 1997). The aim of this development is to allow XMCD to be carried out on a beamline where the planar undulator produces a strictly linearly polarized beam. The undulator fundamental can be tuned between 4.5 keV and 8 keV, while the spectral range from 8 to 25 keV is accessible using the second or higher undulator harmonics. A curved Si(111) crystal in Bragg configuration was used as a dispersive polychromator. A polychromatic focus of 30 × 100 µm is obtained using a four-point bender. The particular contour of the crystal minimizes optical aberrations (Pellicer-Porres et al., 1998). The energy-dispersive spectrometer is arranged in a θ−2θ set-up. The detector is a CCD camera made of 512 × 512 pixels and lens coupled to a scintillation screen which receives the X-ray photons (Koch et al., 1995).
Previous tests aiming to assess the possibility of installing a QWP on an energy-dispersive spectrometer have been carried out at LURE. Due to the large divergence of the DCI source (∼80 arcsec), the circular polarization rate of the beam transmitted by the plate was of the order of 60% at 7 keV (Giles et al., 1993; Giles, Malgrange, Goulon, de Bergevin, Vettier, Dartyge, Fontaine, Giorgetti & Pizzini, 1994; Giles, Malgrange, Goulon, de Bergevin, Vettier, Dartyge, Fontaine & Pizzini, 1994). This was sufficient to measure high-quality L2,3-edge XMCD spectra of heavy rare earths. On the other hand, we showed that at the Ho L3-edge the transmitted by the diamond was a factor of three larger than that available when moving outside the orbit plane by the amount necessary to obtain the same Pc.
In this experiment, as in most experiments performed at LURE, the (111) diamond crystal was operated in the asymmetric Laue geometry using the diffracting planes which make a 19.47° angle with the [111] direction normal to the phase plate. For energies around the L2,3-edges of rare earths from Gd to Ho, the Bragg angles fall at around 20° and the X-ray beam has an almost normal incidence on the diamond entrance face. The transmission of the plate is ∼0.2 at the Gd L3 edge.
The diamond crystal is installed close to the polychromatic focus point of the Si crystal. The main constraint of the energy-dispersive set-up is that the different energies diffracted by the curved Si crystal should satisfy Bragg's law simultaneously on the diamond crystal. This is equivalent to a condition of non-dispersivity between the two crystals which can be written as
where θ1 and θ2 are the Bragg angles on the polychromator and the phase plate, respectively, for the mean energy. b is related to the angle of asymmetry, α, of the reflecting planes on the polychromator by the relation b = sin(θ − α)/sin(θ + α). p is the distance between the source and the crystal, q is the distance between the crystal and the focus point. This equation links the lattice parameters of the reflection planes used on the first and the second crystal and contains as parameter the angle Ψ between the two diffraction planes.
In order to achieve optimized conditions, Ψ can be varied with respect to the ideal 45° value at the expense of Pc (equation 4). It can be shown that, for the chosen configuration and for energies between 7 and 9 keV, the Ψ values fall between 40 and 50° giving a circular polarization rate larger than 0.985.
In Fig. 1 we show, close to Bragg conditions and for four energy windows around the Gd L3 edge (7243 eV), the angular dependence of the transmitted by the diamond crystal. The anomalous increase of the transmission before the Bragg reflection is due to the (Batterman, 1964). The occurrence of this effect is an indication of the high quality of the diamond crystal. The minimum in the transmitted photons corresponds to the loss of intensity associated with diffraction conditions. In order to optimize the non-dispersivity conditions, the transmitted intensity was measured in four energy regions across the (specified in Fig. 2). The angle Ψ was optimized in order to obtain the same for the four energy windows. This could be performed with a sensitivity of 0.1° and Ψ was found to be approximately 41°.
The ferromagnetic samples for XMCD experiments were set at the spectrometer focus point, between the poles of a 1.05 T NdFeB permanent magnet built by Magnetic Solutions. The magnetic field direction can be rapidly (<1 s) switched from parallel to antiparallel to the X-ray propagation direction, thanks to a rotation stage operated by compressed air.
The Gd L3-edge XMCD spectrum measured with the diamond plate for a GdCo5 amorphous film is shown in Fig. 2. The amplitude of the XMCD signal is almost twice as large as that obtained at LURE on the same sample (Rueff, 1996). Thanks to the extremely small divergence of the beam emitted by the ESRF undulator, the circular polarization rate delivered by the QWP is largely improved with respect to our previous experiments at LURE.
In order to better characterize the efficiency of the diamond phase plate, XMCD measurements were carried out for several incident angles corresponding to offsets between −110 and +110 arcsec. The variation of the XMCD amplitude with Δθ is a measure of the circular polarization rate. The absolute circular polarization rate of the X-rays transmitted by the QWP could be obtained by comparison with theoretical values, convoluted with a Gaussian function which takes into account the X-ray divergence. The comparison of measurement and theory is shown in Fig. 3 for the Gd L3 signal of the GdCo5 film. The best agreement is obtained supposing a source divergence of the order of 4.5 arcsec which is consistent with the characteristics of the beamline. Note that the maximum polarization rate obtained under quarter-wave-plate conditions, at ±75 arcsec, is of the order of 0.99, in agreement with the value expected from (1) for Ψ ≃ 41°. Note that, consistent with the very small beam divergence, a very high degree of circular polarization is also obtained for offsets of ±25 arcsec corresponding to three-quarter-wave-plate conditions.
In a classical set-up, i.e. on a bending-magnet beamline, it is not so straightforward to change the X-ray helicity. The XMCD measurement is therefore carried out with a fixed helicity and by measuring the difference of absorption for opposite directions of the applied magnetic field [μ(+B) − μ(−B)]. When using this set-up, the applied magnetic field has to exceed the coercive field of the studied sample in order to reverse the magnetization. When using a quarter-wave plate, the X-ray helicity can be switched from right to left by flipping the offset from positive to negative; we measure [μR − μL]. The advantage of this set-up is that the applied field can be used as a degree of freedom; element-selective magnetization and hysteresis curves can then be measured (Chen et al., 1993; Pizzini et al., 1997). We have already shown that the signal measured this way is the superposition of XMCD and a residual non-magnetic term, deriving mainly from the different absorption of the QWP in the two angular positions (Giles, 1995). This term can be eliminated by carrying out two `flipping' measurements {[μR(+B) − μL(+B)] and [μR(−B) − μL(−B)]} with fixed fields of opposite directions. The half-difference of these two measurements recovers the XMCD signal, as the non-magnetic background is the same in the two cases.
In Fig. 4 we show the [μR − μL] spectra obtained for GdCo5 by alternating the diamond crystal between two quarter-wave-plate offsets of ±75 arcsec, corresponding to maximum and equal right and left helicities (see Fig. 3). The spectra were measured twice, with fixed field +B and −B applied parallel and antiparallel, respectively, to the X-ray propagation direction. The half-difference of these two spectra is indeed identical to the XMCD signal measured by reversing the applied field direction (Fig. 4). The half-sum is the field-independent background mentioned above. The non-magnetic origin of this signal is confirmed by the fact that the same effect is observed when [μR − μL] is measured for the same sample in an unmagnetized state. Fig. 1 shows that, close to Bragg conditions, the transmitted by the diamond crystal is different for two opposite offset values. This effect gives the observed shift of the XMCD baseline as −6 × 10−2 (Fig. 4). Close to the edge the structures in the background signal are sample specific. X-rays emerging from the crystal at a slightly different angle and position cause a slight shift of the energy scales in the two geometries. This gives a derivative-like signal at the edge, to which the effect of sample defects will have to be added. Fig. 4 shows that the effect is of the order of some 10−3 at the edge. This is small compared with the magnitude of the L2,3 XMCD signal for rare earths but becomes important when K edges of 3d transition metals are measured.
2. Applications
As examples of application of this set-up we describe two experiments recently carried out on the ID24 beamline.
2.1. Polarization of Ce 5d states in CeH/Fe multilayers
Ce L2,3-edge (6.1 and 5.7 keV) XMCD spectra were measured for a series of hydrided CeH/Fe multilayers. Fig. 5 shows the temperature-dependent Ce L3-edge XMCD signal carried out for a CeH16 Å/Fe16 Å sample. These hydrided heterostructures present magnetic properties very different from those previously studied for non-hydrided multilayers (Klose et al., 1994). They present a strong perpendicular anisotropy at low temperatures and magnetic coupling of Fe across the CeH layers (Bauer et al., 1994; Schulte et al., 1995). The spectra were recorded between 10 K and 300 K using a closed-cycle refrigerator.
For this experiment a 200 µm-thick diamond (100) crystal was used. With the angle between the (111) planes and the crystal normal being 35.26°, an almost normal incident geometry is obtained at the Ce L2,3 edges, where the Bragg angles are ∼32 and 29°. The transmission of the crystal at 6 keV is ∼0.5. The offsets for quarter-wave-plate conditions are ±50 arcsec.
Each spectrum was obtained in the `classical' way by switching the direction of the magnetic field, keeping a fixed helicity. The spectra in Fig. 5 are the result of 51 field inversions, for a total acquisition time of 20 min. A good signal-to-noise ratio is obtained even for the low-temperature signal, where the magnitude of the XMCD signal is only 1.5 × 10−3.
The presence of an XMCD signal at the Ce L3 edge at 300 K indicates that the Ce 5d states are magnetically polarized. The presence of a single-peak structure is in contrast with the double-peak structure found for the XMCD signal in non-hydrided samples (Klose et al., 1994). This would indicate a relocalization of 4f states in this system. Details of this experiment will be reported in a future paper (Arend et al., 1998).
2.2. Nanosecond-resolved XMCD measurements
Taking advantage of the time structure of the X-ray beam in single-bunch operation mode, we were able to carry out the first nanosecond-resolved XMCD measurements (Bonfim et al., 1998). Circular polarization at the Gd L3 edge was obtained using the 0.74 mm-thick diamond (111) quarter-wave plate.
The experiment is conceived as a pump–probe scheme. The pump is a pulsed magnetic field of a few nanoseconds, generated by microcoils at the 357 kHz ESRF frequency. The hairpin-shaped 50 µm-thick copper microcoil with a 50 µm-wide gap takes full advantage of the focusing optics (a spot size as small as 30 × 100 µm) of the energy-dispersive
spectrometer. 25 ns-long pulses of 100 A current generate 0.4 T-high magnetic field pulses.The probe is a 100 ps-long X-ray pulse processed by an energy-dispersive X-ray absorption spectrometer. The single-bunch filling allows the delay between the pump and the probe to be tuned from 0 to 2.8 µs, the temporal distance between two X-ray bunches. A series of XMCD measurements were carried out, each corresponding to a particular delay between the X-ray bunch and the magnetic pulse. The XMCD signal was obtained as the difference of two absorption spectra collected with right and left circular polarizations. The two helicities were obtained by flipping the quarter-wave plate from one side of the (111) Bragg profile to the other. The XMCD signal is a result of photons from a few hundred million bunches, each of which has the same phase relationship with the magnetic pulse.
In this first investigation we have analyzed the time response of a GdCo3 amorphous thin film grown by sputtering at the Laboratoire Louis Néel. The film is slightly anisotropic with the easy axis of magnetization in the plane of the film. The pulsed field produced by the microcoil is applied perpendicular to the film, along the X-ray propagation direction. In this scheme the 100 ps-long X-ray bunch probes progressive magnetization during and after the magnetic pulse. Details of this experiment are described by Bonfim et al. (1998).
In Fig. 6 we show the time evolution of the XMCD signal during and after a 22 ns-long 0.7 T field pulse. The acquisition time for each spectrum is approximately 3 min, during which the QWP offset was reversed 11 times. In Fig. 7 the amplitude of the XMCD intensity for two amplitudes of the field pulses (0.3 and 0.7 T) is reported together with the time evolution of the field pulse. The magnetization of the GdCo3 film closely follows the current, which indicates that the characteristic time for spin rotation from the parallel to perpendicular direction is smaller than 10−9 s.
Acknowledgements
We thank Professor W. Felsch of Göttingen University for letting us present the data on CeH/Fe multilayers, C. M. Giles of LNLS Campinas for help in setting up the QWP, Thomas Neisius of ESRF for help on the beamline, and Sebastian Pasternak of ESRF for technical support. We are also grateful to Professor A. R. Lang (Bristol University) and Professor T. Ishikawa (SPring-8) for kindly lending us the diamond crystals. The experimental work at the ESRF has been performed with the approval of the Program Advisory Committee (proposal HE-004).
References
Arend, M., Felsch, W., Krill, G., Delobbe, A., Baudelet, F., Dartyge, E., Kappler, J.-P., Finazzi, M., Pizzini, S., Fontaine, A. & San Miguel-Fuster, A. (1998). Submitted.
Batterman, B. W. (1964). Rev. Mod. Phys. 36, 681–716. CrossRef CAS Web of Science
Bauer, Ph., Klose, F., Schulte, O. & Felsch, W. (1994). J. Mag. Mag. Mater. 138, 163–172. CrossRef CAS Web of Science
Bonfim, M., Mackay, K., Pizzini, S., San-Miguel, A., Tolentino, H., Giles, C., Neisius, T., Hagelstein, A., Baudelet, F., Malgrange, C. & Fontaine, A. (1998). J. Synchrotron Rad. 5, 750–752. Web of Science CrossRef IUCr Journals
Chen, C. T., Idzerda, Y. U., Lin, H.-J., Meigs, G., Chaiken, A., Prinz, G. A. & Ho, G. A. (1993). Phys. Rev. B, 48, 642–645. CrossRef CAS Web of Science
Dmitrienko, V. E. & Belyakov, V. A. (1980). Sov. Technol. Phys. Lett. 6, 621–622.
Elleaume, P. (1990). Nucl. Instrum. Methods, A291, 371–377. CrossRef CAS Web of Science
Giles, C. (1995). PhD thesis, Université Paris 7 – Denis Diderot, France.
Giles, C., Malgrange, C., Goulon, J., de Bergevin, F., Vettier, C., Dartyge, E., Fontaine, A., Giorgetti, C. & Pizzini, S. (1993). Acta Cryst. A49, C377. CrossRef IUCr Journals
Giles, C., Malgrange, C., Goulon, J., de Bergevin, F., Vettier, C., Dartyge, E., Fontaine, A., Giorgetti, C. & Pizzini, S. (1994). J. Appl. Cryst. 27, 232–240. CrossRef CAS Web of Science IUCr Journals
Giles, C., Malgrange, C., Goulon, J., de Bergevin, F., Vettier, C., Dartyge, E., Fontaine, A. & Pizzini, S. (1994). Nucl. Instrum. Methods, A349, 622–625. CrossRef Web of Science
Golovchenko, J. A., Kincaid, B. M., Levesque, R. A., Meixner, A. E. & Kaplan, D. R. (1986). Phys. Rev. Lett. 57, 202–205. CrossRef PubMed CAS Web of Science
Goulon, J., Goulon-Ginet, C. & Brookes, N. B. (1997). Editors. Proceedings of the 9th International Conference on XAFS, Grenoble, August 1996.
Hagelstein, M., San-Miguel, A., Fontaine, A. & Goulon, J. (1997). J. Phys. IV, 7(C2), 303–308.
Hirano, K., Izumi, K., Ishikawa, T. & Kikuta, S. (1991). Jpn. J. Appl. Phys. 30, L407. CrossRef Web of Science
Hirano, K., Kanzaki, K., Mikami, M., Tamasaku, K., Ishikawa, T. & Kikuta, S. (1992). J. Appl. Cryst. 25, 531. CrossRef Web of Science IUCr Journals
Klose, F., Schulte, O., Rose, F., Felsch, W., Pizzini, S., Giorgetti, C., Baudelet, F., Dartyge, E., Krill, G. & Fontaine A. (1994). Phys. Rev. B, 50, 6174–6183. CrossRef CAS Web of Science
Koch, A., Hagelstein, M., San-Miguel, A., Fontaine, A. & Ressler, T. (1995). Proc. SPIE, 2416, 85–93. CrossRef
Pellicer-Porres, J., San-Miguel, A. & Fontaine, A. (1998). J. Synchrotron Rad. 5, 1250–1257. Web of Science CrossRef IUCr Journals
Pizzini, S., Fontaine, A., Garcia, L. M., Bobo, J.-F., Piecuch, M., Baudelet, F., Malgrange, C., Alimoussa, C., Snoeck, E. & Casanove, M. J. (1997). J. Mag. Mag. Mater. 166, 38–44. CrossRef CAS Web of Science
Rueff, J. P. (1996). PhD thesis, Université J. Fourier, Grenoble, France.
Sasaki, S. (1993). Nucl. Instrum. Methods, A331, 763–767. CrossRef CAS Web of Science
Schulte, O., Klose, F. & Felsch, W. (1995). Phys. Rev. B, 52, 6480–6488. CrossRef CAS Web of Science
Yamamoto, S. & Kitamura, H. (1987). Jpn. J. Appl. Phys. 26(10), L1613–1615. CrossRef
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.