invited papers
Development of an in situ polarization-dependent total-reflection fluorescence measurement system
aDepartment of Chemistry, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan, bPhoton Factory, Institute of Material Structure Science, Oho, Tsukuba 305-0801, Japan, and cCatalysis Research Center, Hokkaido University, Kita 11 Nishi 10, Kita-ku, Sapporo, 060-0811, Japan
*Correspondence e-mail: askr@cat.hokudai.ac.jp
An in situ polarization-dependent total-reflection fluorescence X-ray absorption fine structure (PTRF-XAFS) spectroscopy system has been developed, which enables PTRF-XAFS experiments to be performed in three different orientations at various temperatures (273–600 K) and pressures (10−10∼760 torr). The system consists of a measurement chamber and a preparation chamber. The measurement chamber has a high-precision six-axis goniometer and a multi-element solid-state detector. Using a transfer chamber, also operated under ultra-high-vacuum conditions, the sample can be transferred to the measurement chamber from the preparation chamber, which possesses and facilities, as well as a sputtering gun and an annealing system. The in situ PTRF-EXAFS for Cu species on TiO2 (110) has been measured in three different orientations, revealing anisotropic growth of Cu under the influence of the TiO2 (110) surface.
Keywords: polarization-dependent total-reflection fluorescence; metal–substrate interface; Cu/TiO2 catalyst.
1. Introduction
Most industrial catalysts are used in the form of supported-metal catalysts. The role of the support is not only to disperse the active sites but also to modify the catalytic properties through so-called `metal–support interactions'. Although a number of concepts have been proposed to explain the metal–support interaction, lack of accurate knowledge about the interface structures and the bonding features between
sites and support surfaces inhibits a full understanding of the essence of the metal–support interaction.Extended X-ray absorption fine structure (EXAFS) spectroscopy is one of the most powerful techniques currently used to study the structure of supported catalysts (Koningsberger & Prins, 1988; Iwasawa, 1996). In order to determine the interface structure in a supported catalyst, has been applied to model catalysts in which small metal particles are deposited on powder oxides (van Zon et al., 1984; Martens et al., 1988; Koningsberger & Gates, 1992; Asakura et al., 1985; Koningsberger et al., 1996). However, careful interpretation and analysis are required to elucidate the interface structures because the results derived from the usual are averaged in all directions and the contribution from the interface structure is often weaker than that from the metal–metal interaction in the metal particles.
EXAFS has a polarization dependence expressed as
where χ(k), θi and χi(k) are an oscillation, an angle between the ith bond and the polarization vector of the incident X-ray, and an oscillation accompanying the ith bond, respectively. Hence, equation (1) indicates that if one can use a flat substrate with species deposited thereon and set the sample surface parallel to the electric polarization vector, one can obtain the interface structure selectively.
In order to investigate the structure of the metal species dispersed on the flat substrate, we have developed polarization-dependent total-reflection fluorescence X-ray absorption fine structure (PTRF-XAFS) spectroscopy (Asakura et al., 1993, 2000; Shirai & Iwasawa, 1996). The total-reflection fluorescence mode is necessary to obtain of the surface species when the coverage of the surface species is less than one monolayer (Heald et al., 1984, 1988; Chen & Heald, 1993). We have applied the method to Co oxide on α-Al2O3 (0001), Cu oxide on α-quartz (0001), Pt4 clusters on α-Al2O3 (0001), and Mo oxide on rutile TiO2 (110) (Shirai et al., 1992; Shirai, Asakura & Iwasawa, 1994; Shirai, Inoue et al., 1994; Asakura et al., 1997; Chun et al., 1998). We have found that Pt deposited on α-Al2O3 (0001) has a one-atomic-layer structure with Pt—O(Al) = 0.220 nm (Asakura et al., 1997). In the Mo oxide on TiO2 (110), a dimer structure is formed with an Mo—Mo bond perpendicular to the (001) direction and Mo—O(Ti) and Mo—Ti distances of 0.220 and 0.295 nm, respectively (Chun et al., 1998). We have also developed an in situ PTRF-XAFS chamber suitable for catalyst samples investigated under reaction conditions (Shirai et al., 1995). However, it was difficult to install a heavy multi-element solid-state detector (SSD) for the fluorescence detection or an LEED (low-energy electron diffraction)–AES (Auger electron spectroscopy) instrument for surface characterization, because the position and orientation of the whole chamber needed to be adjusted to obtain the total-reflection conditions.
In this paper, we report the design and the performance of a newly built in situ system for PTRF-XAFS measurements. The system had to realise the following concepts.
2. In situ PTRF-XAFS system
To satisfy the above conditions (iv) and (v) at the same time, we constructed two separate ultra-high-vacuum (UHV) chambers, a sample-preparation chamber and a PTRF-XAFS measurement chamber, between which samples are transferred with a transfer chamber.
Fig. 1 illustrates the measurement chamber, the dimensions of which are 400 (width) × 400 (length) × 600 (height) mm and the base pressure of which is 10−10 torr (1 torr = 133.32 Pa). Reaction gases can be introduced through two leak valves and gas-phase analysis can be carried out by a quadrupole (Q-mass; Balzers Co., Prisma). Incident and reflected X-rays pass through two Be windows (thickness 200 µm, diameter 14 mm, purity 99.8%). The beam size of the incident X-rays can be adjusted by selecting a series of Ta pinhole slits in front of the I0 ionization chamber.
A multi-element SSD can be placed outside the chamber and the fluorescence signal is extracted through Be windows attached to the UHV flange. The positions of the Be windows are in line with those of the SSD windows in order to obtain maximum efficiency. The use of a multi-element SSD increases the solid angle and the maximum counting rates, as reported by Oyanagi & Nomura (Oyanagi et al., 1998; Nomura, 1998). Moreover, the SSD can eliminate residual and fluorescence of the substrate and coexisting elements in order to increase the signal-to-background ratio. In the PTRF-XAFS measurement of a single-crystal substrate, diffracted beams from the substrate produce a discontinuity in the spectra at certain energies. Because the directionality of the diffracted beam is sharp, the diffraction line can be eliminated by an adequate adjustment of the detector position (Chun et al., 1996). In the multi-element detection system, the diffracted beam can be easily removed by omitting the data of a few detector elements that suffer from the diffraction line, as shown in Fig. 2.
The sample can be heated up to 600 K by resistive heating of W wire mounted in the sample holder. A ceramics block thermally and electrically isolates a goniometer from the sample holder.
To achieve total-reflection conditions precisely, we have used a UHV-compatible six-axis goniometer, as shown in Fig. 3. The goniometer is made of aluminium in order to lessen the weight load on the stepping motors. The rotation centre of the goniometer is fixed at that of the sample surface. Three (θ, φ and χ) rotation axes are driven by bake-proof vacuum stepping motors (Oriental Motors Co. UPX535M), while x, y and z motions are introduced from outside the chamber using usual stepping motors (Oriental Motors Co. UPD533HGI-NA, UPK564A-TG20). The range and precision for each axis are listed in Table 1.
|
Fig. 4 shows the X-ray reflectivity of the TiO2 (110) surface at an energy of 9.3 keV. The critical angle was 3 mrad. The angle and the position could be reproduced even after a wide range of rotations and movements at room temperature. However, there was a small shift in the angle datum point when the sample was heated at elevated temperatures. The broken line in Fig. 4 represents the X-ray reflectivity of the same sample after heating at 473 K and cooling to room temperature in hydrogen atmosphere. The shift of the datum point was only 0.5 mrad. Therefore, one has to readjust the total-reflection conditions when the sample has been heated at a different temperature.
Fig. 3 shows the setup of the goniometer for three different sample configurations, i.e. the electric vector perpendicular to the surface (p-polarization) and those parallel to the surface (s-polarization). If the surface symmetry is less than threefold, two directions parallel to the surface can be distinguished. For example, rutile TiO2 (110) has different structures between the [001] and [10] directions (Chun et al., 1998).
Fig. 5 shows a perspective view of the preparation chamber. The UHV chamber [350 (width) × 350 (length) × 400 (height) mm] can be equipped with Q-Mass, LEED, AES and XPS (X-ray photoelectron spectroscopy) instruments. The base pressure is 10−10 torr. The substrate crystal can be cleaned by repeated Ar-ion sputtering and annealing cycles in the preparation chamber. A large crystal (more than 2 cm long) is required in order to increase the radiation area for grazing-incidence conditions. The sample can be completely covered with the mug-shaped heating module and annealed homogeneously up to 1000 K.
The prepared samples are then transferred to the measurement chamber using a small transfer chamber, which is also operated under UHV conditions. A non-evaporable getter pump is installed to maintain the high vacuum during the transfer of the sample from the preparation chamber to the measurement chamber in a beamline. The transfer chamber can contain two samples at the same time and thus the transfer chamber may be used as a `parking lot' for the samples.
3. In situ PTRF-XAFS measurement of Cu particles on TiO2 (110) derived from Cu(DPM)2 as a precursor under temperature-programmed reduction
Cu/TiO2 shows high activity in methanol synthesis by CO2 hydrogenation and photocatalytic reduction of N2O at room temperature. As a model of the Cu/TiO2 catalyst, we deposited a Cu species on a TiO2 (110) single crystal. We used Cu(DPM)2 (DPM = 2,2,6,6-tetramethyl-3,5-heptanedione) as the precursor for the Cu species, which can be easily reduced at low temperature under H2 atmosphere (Sekine et al., 1992). Cu species were deposited on the TiO2 (110) by dropwise addition of a diethyl ether solution of Cu(DPM)2 under Ar flow. The remaining solvent was removed by evacuation for 24 h. The samples were then transferred to the measurement chamber.
Temperature-programmed reduction (TPR) was carried out in the measurement chamber at a rate of 8 K min−1 under 2 torr H2. PTRF-XAFS spectra were measured at BL12C of the Photon Factory in the Institute of Material Structure Science, High Energy Accelerator Research Organization (KEK-PF) (Proposal No. 98 G305). The synchrotron radiation was monochromated by a Si (111) double-crystal monochromator. The storage ring was operated at 2.5 GeV and 200–400 mA. Cu K-edge spectra were recorded in the range 8660–9500 eV at room temperature. The X-ray beam size was reduced to 0.4 mm in diameter in order to decrease unnecessary irradiation.
Cu K-edge measurements were carried out in three different directions of the electric vector of the incident X-rays, i.e. parallel to the [10], [001] and [110] axes of TiO2 (110). Fig. 6 shows the PTRF-XANES spectra parallel to the [001] direction during the TPR process. By increasing the reduction temperature, we observed that the pre-edge shoulder in the XANES spectra gradually increased up to 363 K. Fig. 7 shows the background-subtracted PTRF-EXAFS spectra of the sample treated at 363 K. χ(k) along the [001] axes showed different features compared with the behaviour in other directions. The detailed analysis of the data will be discussed in another paper (Tanizawa et al., 2001) but the data clearly indicate the presence of anisotropic structure caused by the preferential formation of Cu—Cu bonds along the [001] direction of the TiO2(110) support.
4. Conclusion
PTRF-XAFS has become a practical tool for the determination of the structure of the dispersed species on model single-crystal surfaces and enables us to start systematic investigations of metal–support interface structures.
Footnotes
‡Present address: Center for Analytical Chemistry and Science, Inc., 8-3-1, Chu-o, Ami, Inashiki, Ibaraki 300-0332, Japan.
Acknowledgements
This work has been supported by CREST (Core Research for Evolutional Science and Technology) of the Japan Science and Technology Corporation (JST) and performed under the approval of the Photon Factory Advisory Committee (Proposal No. 98G305).
References
Asakura, K., Chun, W.-J. & Iwasawa, Y. (2000). Top. Catal. 10, 209–219. Web of Science CrossRef CAS
Asakura, K., Chun, W.-J., Shirai, M., Tomishige, K. & Iwasawa, Y. (1997). J. Phys. Chem. B, 101, 5549–5556. CrossRef CAS Web of Science
Asakura, K., Shirai, M. & Iwasawa, Y. (1993). Catal. Lett. 20, 117–124. CrossRef CAS Web of Science
Asakura, K., Yamada, M., Iwasawa, Y. & Kuroda, H. (1985). Chem. Lett. pp. 511–514. CrossRef Web of Science
Chen, H. & Heald, S. M. (1993). J. Appl. Phys. 73, 2467–2471. CrossRef CAS Web of Science
Chun, W.-J., Asakura, K. & Iwasawa, Y. (1996). J. Synchrotron Rad. 3, 160–162. CrossRef CAS Web of Science IUCr Journals
Chun, W.-J., Asakura, K. & Iwasawa, Y. (1998). J. Phys. Chem. B, 102, 9006–9014. Web of Science CrossRef CAS
Heald, S. M., Chen, H. & Tranquada, J. M. (1988). Phys. Rev. B, 38, 1016–1026. CrossRef CAS Web of Science
Heald, M., Keller, E. & Stern, E. A. (1984). Phys. Lett. 103A, 155–158. CAS
Iwasawa, Y. (1996). Editor. X-ray Absorption Fine Structure for Catalysts and Surfaces. Singapore: World Scientific.
Koningsberger, D. C. & Gates, B. C. (1992). Catal. Lett. 14, 271–277. CrossRef CAS Web of Science
Koningsberger, D. C. & Prins, R. (1988). Editors. X-ray Absorption, Principles, Applications, Techniques of EXAFS, SEXAFS and XANES. New York: John Wiley.
Koningsberger, D. C., van Zon, F. B. M., Vaarkamp, M. & Munoz-Paez, A. (1996). X-ray Absorption Fine Structure for Catalysts and Surfaces, edited by Y. Iwasawa, p. 257. Singapore: World Scientific.
Martens, J. H. A., Prins, R., Zanbergen, H. & Koningsberger, D. C. (1988). J. Phys. Chem. 92, 1903–1916. CrossRef CAS Web of Science
Nomura, M. (1998). J. Synchrotron Rad. 5, 851–853. Web of Science CrossRef CAS IUCr Journals
Oyanagi, H., Martini, M. & Saito, M. (1998). Nucl. Instrum. Methods, 403, 58–64. Web of Science CrossRef CAS
Sekine, R., Kawai, M., Asakura, K., Hikita, T. & Kudo, M. (1992). Surf. Sci. 278, 175–182. CrossRef CAS Web of Science
Shirai, M., Asakura, K. & Iwasawa, Y. (1992). Chem. Lett. pp. 1037–1040. CrossRef Web of Science
Shirai, M., Asakura, K. & Iwasawa, Y. (1994). Catal. Lett. 26, 229–234. CrossRef CAS Web of Science
Shirai, M., Inoue, T., Onishi, H., Asakura, K. & Iwasawa, Y. (1994). J. Catal. 145, 159–164. CrossRef CAS Web of Science
Shirai, M. & Iwasawa, Y. (1996). X-ray Absorption Fine Structure for Catalysts and Surfaces, edited by Y. Iwasawa, p. 332. Singapore: World Scientific.
Shirai, M., Nomura, M., Asakura, K. & Iwasawa, Y. (1995). Rev. Sci. Instrum. 66, 5493–5498. CrossRef CAS Web of Science
Tanizawa, Y., Chun, W.-J., Shido, T., Asakura, K. & Iwasawa, Y. (2001). J. Synchrotron Rad. 8, pp. 508–510. Web of Science CrossRef CAS IUCr Journals
Zon, J. B. A. D. van, Koningsberger, D. C., van't Blik, H. F. J., Prins, R. & Sayers, D. E. (1984). J. Chem. Phys. 80, 3914–3915.
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.