Short-period multilayer X-ray mirrors

CROSSMARK_Color_square_no_text.svg

aInstitute for Physics of Microstructures RAS, 603600, GSP 105, Nizhny Novgorod, Russia, bBESSY II, Albert Einstein Strasse 15, D-12489 Berlin, Germany, and cA. F. Ioffe Physico-Technical Institute RAS, Politechnicheskaya 26, 194021, St Petersburg, Russia
*Correspondence e-mail: kp@ipm.sci-nnov.ru

(Received 25 January 2003; accepted 7 July 2003)

Multilayer structures with short periods have been systematically investigated using a tunable soft X-ray synchrotron, BESSY II, and X-ray tube radiation. Multilayer X-ray mirrors of W/B4C, W/Sc, Mo/B4C, Mo/C, La/B4C, Cr/C and Cr/Sc, with periods from 0.8 nm to 3.5 nm and number of periods up to 300–400, were constructed and investigated. The high reflectivity and spectral resolution of the mirrors allow them to be used to create multimirror systems for X-ray diagnostics of high-temperature plasma, for X-ray astronomy and microscopy.

1. Introduction

Multilayer X-ray mirrors with small (1–3 nm) periods are currently attracting considerable attention owing to the fact that they can be used for the development of optics in many important applications. These mirrors are used as radiation-stable dispersion elements and polarizers for synchrotron radiation, as dispersion elements for high-temperature plasma diagnostics, for the creation of normal-incidence optical systems for projection microscopy in the `water window' spectral range and X-ray astronomy, and for the formation of X-ray radiation beams. As a rule, from 200 to 400 periods participate in effective reflection in such mirrors; therefore the fabrication process of mirrors should provide stability of the thickness of periods on the depth of a structure, δdd/N (where d is the value of the period and N is the number of periods); usually δd ≃ 5 × 10−3 nm. Details of the fabrication process of such mirrors, and results of research on their properties are considered here.

In the given work, short-period multilayer X-ray mirrors were systematically investigated using a broad class of materials and with the help of tunable synchrotron radiation from BESSY II and radiation from a special dismountable X-ray tube. Multilayer X-ray mirrors, of W/B4C, Mo/B4C, Mo/C, La/B4C, Cr/C and Cr/Sc with periods from 0.8 nm to 3.5 nm and number of periods up to 300–400, were constructed and investigated.

The multilayer mirrors were fabricated using a standard magnetron sputtering set-up comprising two 150 mm-diameter magnetrons and power and controlling supply. The targets were sputtered in Ar at a pressure of 8 × 10−2 to 9 × 10−2 Pa. The initial pressure of the residual gas at pumping was ∼10−4 Pa. Targets were sputtered by DC and RF current sources. In the sputter process the stability of the parameters of the magnetron discharge is the determining factor. A stability of better than 1% is achieved by deep modernization of the magnetron sputter sources and power control. The controlling system automatically provides a change in the gas pressure if some instability in the discharge occurs. Small-angle X-ray diffraction measurements were taken (in order to determine the parameters of the period of the mirrors) and the relationships between the layer thicknesses of different materials in a period and evaluations of the height of the interplanar interface roughness were investigated using a standard X-ray diffractometer.

2. Experimental results

The most detailed research was carried out using mirrors based on Cr/Sc and was first shown by Schafers et al. (1998[Schafers, F., Mertins, H.-Ch., Packe, I., Schmolla, I., Salashchenko, N. N. & Shamov, E. A. (1998). Appl. Opt. 37, 719-722.], 2001[Schafers, F., Mertin, M., Abramsohn, D., Gaupp, A., Mertins, H.-Ch. & Salashchenko, N. N. (2001). Nucl. Instrum. Methods Phys. Res. A, 467/468, 349-353.]). The Cr/Sc multilayer samples with periods in the 1.5–3 nm range were made by magnetron sputtering technology and were investigated by using s-polarized synchrotron radiation in the 3.1–6.3 nm spectral range. In the entire spectral range, normal-incidence mirrors have a reflectivity of 11–8% (Fig. 1[link]). The multilayer mirrors were deposited on silicon substrates and on Si3N4 membranes with a thickness of 100 nm at the same time. The Cr/Sc mirrors are of special interest for applications in the area of the L absorption edges of Cr (λL ≃ 2.16 nm) and Sc (λL ≃ 3.09 nm). The Cr/Sc mirrors operating in reflection and in transmission were used as a basis for developing soft X-ray polarimeters at BESSY II (Schafers et al., 1999[Schafers, F., Mertins, H.-Ch., Gaupp, A., Gudat, W., Mertin, M., Packe, I., Schmolla, F., Di Fonzo, S., Soullie, G., Jark, W., Walker, R., Le Cann, X., Nyholm, R. & Eriksson, M. (1999). Appl. Opt. 38, 4074-4079.]).

[Figure 1]
Figure 1
Short-period multilayer X-ray mirrors based on Cr/Sc. Triangles: measurements for θ = 85°. Squares: measurements for θ = 45°, where θ is the angle from the surface of the substrate and R is the reflectivity for s-polarization.

A detailed research of the reflectivity of the mirrors in the 3.1–3.4 nm spectral region for angle and spectral dependences was carried out (Fig. 2[link]). As was expected, outside the area of Sc anomalous dispersion the reflection of the Cr/Sc multilayer mirror is 1.5 times lower at a practically constant spectral resolution (about 250). However, at the same time, Cr/Sc is the optimal pair of materials for fabrication of dispersing and focusing elements for the practically interesting line of a hydrogen-like ion of carbon, λCVI = 3.373 nm (Birch et al., 2003[Birch, J., Eriksson, F., Johansson, G. A. & Hertz, H. M. (2003). Vacuum, 68, 275-282.]; Eriksson et al., 2002[Eriksson, F., Johansson, G. A., Hertz, H. M. & Birch, J. (2002). Opt. Eng. 41, 2903-2907.]).

[Figure 2]
Figure 2
Reflectivity of Cr/Sc mirrors with periods of 1.57–1.70 nm in the spectral region 3.1–3.4 nm for spectral and angle measurements (s-polarization). Triangles: angle measurements at λ = 3.14 nm. Squares: spectral characteristics for θ = 85.6°.

The mirrors were investigated in the 3–3.5 keV spectral range for application of Cr/Sc multilayer structures for spectrally selective soft X-ray tomography of argon ions in tokamak plasma (Shmaenok et al., 2001[Shmaenok, L. A., Golovkin, S. V., Govorun, V. N., Ekimov, A. V., Salashchenko, N. N., Pikalov, V. V., Belik, V. P., Schuller, F. C., Donne, A. J. H., Oomens, A. A. M., Prokhorov, K. A., Andreev, S. S., Sorokin, A. A., Podlaskin, B. G. & Khasanov, L. V. (2001). Rev. Sci. Instrum. 72, 1411-1415.]). A multilayer mirror with period 1.57 nm and number of periods N = 250 also has a selectivity of about 250 at a reflectivity of about 6–8% (Fig. 3[link]).

[Figure 3]
Figure 3
Reflectivity of Cr/Sc multilayer at d = 1.57 nm and N = 250 in the spectral area 3–3.5 keV (s-polarization).

The multilayer mirrors were fabricated and investigated (Table 1[link]) for experiments in X-ray tomography of selected spectral lines of ions impurities in tokamak TEXTOR (Shmaenok et al., 2001[Shmaenok, L. A., Golovkin, S. V., Govorun, V. N., Ekimov, A. V., Salashchenko, N. N., Pikalov, V. V., Belik, V. P., Schuller, F. C., Donne, A. J. H., Oomens, A. A. M., Prokhorov, K. A., Andreev, S. S., Sorokin, A. A., Podlaskin, B. G. & Khasanov, L. V. (2001). Rev. Sci. Instrum. 72, 1411-1415.]). The main demand for multilayer X-ray instrumentation for wavelength- and time-resolved plasma emission tomography is for obtaining good reflection at high spectral resolution, making it possible to select a useful investigated impurity signal from the background wide-band radiation of high-temperature plasma.

Table 1
Parameters of multilayer mirrors optimized for specific impurity lines of X-ray radiation

MLS is the multilayer structure, θ is the angle from the surface of the substrate, R is the reflectivity, S = E/ΔE is the selectivity of the MLS, and d is the period.

Ion λ (nm) MLS d (nm) θ (°) R (%) S
Ar XVIII 0.373 Cr/Sc 2.0 5.4 30 150
Ar XVII 0.395 Cr/Sc 2.0 5.7 30 150
Ne X 1.213 W/Si 2.1 17 16 96
Ne IX 1.345 W/Si 2.1 19 13 90
O VIII 1.9 W/Si 2.1 27 6 80
O VII 2.16 Cr/Sc 2.1 31 7 150
Ar XIV 2.74 Fe/Ti 2.5 33.6 13 140
C VI 3.37 Cr/Sc 2.5 41 7 140
C V 4.03 Cr/Sc 3.1 40 9 125
B V 4.86 Fe/C 3.8 40 12 80
B IV 6.03 Cr/C 4.7 40 10 75

In solving some practical and fundamental problems, such as estimating the content of boron in various materials by the method of X-ray fluorescence element analysis (λBKα = 6.76 nm) (Michaelsen et al., 2001[Michaelsen, C., Wiesmann, J., Bormann, R., Nowak, C., Dieker, C., Hollensteiner, S. & Jager, W. (2001). Opt. Lett. 26, 792-794.]) and in the development of equipment for research into the element/charge states and spatial distribution of impurity in high-temperature tokamak plasma in the wavelength range λ ≃ 7–8 nm (for example, λBeIV = 7.59 nm), one has to make use of X-ray dispersion elements optimized for this spectral region and the problems in question. Research into a La/B4C mirror with period 3.5 nm was carried out on the BESSY II synchrotron. A reflectivity of 36.5% with selectivity S = 140 for s-polarized X-rays was obtained at a wavelength of 6.73 nm. On decreasing the wavelength in the area of the B anomalous dispersion (λ = 6.66 nm), the reflectivity increased by up to 42%, which once again confirms the practice of material choice for work behind the absorption edge of the light material included in the structure.

With the purpose of creating multilayer optics for collimation and focusing of hard X-ray radiation (λ ≃ 0.02–0.2 nm), multilayer mirrors W/B4C and W/Sc with extremely short periods of 0.8–1.5 nm and numbers of period up to 400 were fabricated. Multilayer mirrors based on such pairs with short periods are of a special interest, because there is no increase of roughness when the period is reduced, as is shown experimentally (Andreev et al., 1991[Andreev, S. S., Muller, M., Platonov, Yu. Ya., Polushkin, N. I., Salashchenko, N. N., Schafers, F., Shinkarev, S. I., Simanovsky, D. M. & Zuev, S. Yu. (1991). Proc. SPIE, 1800, 195-208.]; Christensen et al., 1991[Christensen, F. E., Zhu S.-H., Hornstrup, A., Schnopper, H. W., Plag, P. & Wood, J. (1991). J. X-ray Sci. Technol. 3, 1-13.]). The cross sections of multilayer samples were investigated by electron microscopy. The characteristics of the mirrors were measured on the K-line radiation of molybdenum, copper and magnesium for non-polarized radiation (Fig. 4[link]).

[Figure 4]
Figure 4
Reflectivity of short-period multilayer mirrors with periods of 0.775–1.5 nm based on W/B4C (X-ray tube). Triangles: measurements at Mo Kα (dotted line). Squares: measurements at Mg Kα (solid line). Circles: measurements at Cu Kα (dashed line).

Multilayer mirrors of W/B4C, Mo/C, Mo/B4C and Cr/C with periods from 1.2 nm to 2.2 nm were constructed and investigated for the spectral regions of the `water window' and hard X-ray radiation. The comparative characteristics of such structures measured in the wavelength range 0.7–1 nm using an X-ray spectrometer–monochromator are given in Table 2[link]. The high selectivity of fabricated multilayer structures with good reflectivity show the opportunity of application of these multilayer mirrors as dispersing elements for X-ray spectroscopy.

Table 2
Multilayer mirrors based on pairs W/B4C, Mo/C, Mo/B4C and Cr/C

MLS          
d (nm); N λ (nm) θ (°) Δθ S = λ/Δλ R (%)
W/B4C 0.989 23 0.11 220 4.9
1.28; 280          
W/B4C 0.989 21.4 0.1 225 6.9
1.35; 200          
W/B4C 0.989 18.94 0.11 180 9.1
1.55; 250          
Mo/C 0.989 20.18 0.08 263 4.35
1.45; 270          
Mo/C 0.989 16.66 0.09 191 12
1.75; 200          
Mo/C 0.989 13.86 0.11 128 19.8
2.09; 170          
Mo/B4C 0.989 22.22 0.1 234 3.45
1.32; 250          
Mo/B4C 0.989 18.29 0.1 189 8.4
1.59; 200          
Mo/B4C 0.989 15.68 0.12 133 12.5
1.86; 160 0.834 13.04 0.11 120 11.7
  0.712 11.04 0.1 111 9.9
Mo/B4C 0.989 16.86 0.12 144 9.3
1.72; 170 0.834 14.01 0.12 119 7.7
  0.712 12.17 0.13 95 7.4
Mo/B4C 0.989 24.24 0.1 257 2.42
1.22; 300 0.834 19.76 0.09 228 1.95
  0.712 16.96 0.08 218 1.2
Cr/C 0.989 13.29 0.1 135 13.2
2.19; 200          

3. Summary

We have presented a systematic investigation of magnetron-deposited short-period multilayer structures of different pairs of materials carried out on the synchrotron BESSY II and on a dismountable X-ray tube in the soft X-ray range. The multilayer X-ray mirrors based on W/B4C, W/Sc, Mo/B4C, Mo/C, La/B4C, Cr/C and Cr/Sc with periods from 0.8 nm to 3.5 nm showed a high reflectivity and spectral resolution, which allows them to be used for various X-ray applications. Normal-incidence Cr/Sc mirrors have a reflectivity of 11–8% in the entire spectral range (3.1–6.3 nm). In the area of Sc anomalous dispersion the reflection of Cr/Sc multilayer mirrors was found to be 1.5 times higher than that outside the range. A wide range of X-ray multilayer mirrors consisting of different pairs of materials were prepared and measured for experiments on X-ray tomography of ion impurities in tokamak TEXTOR. A special investigation of Cr/Sc multilayer mirrors was made for spectrally selective soft X-ray tomography of argon ions in tokamak plasma in the spectral range 3–3.5 keV. Multilayer mirrors of W/B4C and W/Sc with extremely short periods of 0.8–1.5 nm and number of period up to 400 have been fabricated and investigated in order to analyse the possibility of using them for collimation and focusing hard X-ray radiation. Multilayer mirrors of W/B4C, Mo/C, Mo/B4C and Cr/C were prepared and measured in the wavelength range 0.7–1 nm.

Footnotes

Presented at the `XIV Russian Synchrotron Radiation Conference SR2002', held at Novosibirsk, Russia, on 15–19 July 2002.

References

First citationAndreev, S. S., Muller, M., Platonov, Yu. Ya., Polushkin, N. I., Salashchenko, N. N., Schafers, F., Shinkarev, S. I., Simanovsky, D. M. & Zuev, S. Yu. (1991). Proc. SPIE, 1800, 195–208.  CrossRef Google Scholar
First citationBirch, J., Eriksson, F., Johansson, G. A. & Hertz, H. M. (2003). Vacuum, 68, 275–282.  Web of Science CrossRef Google Scholar
First citationChristensen, F. E., Zhu S.-H., Hornstrup, A., Schnopper, H. W., Plag, P. & Wood, J. (1991). J. X-ray Sci. Technol. 3, 1–13.  Google Scholar
First citationEriksson, F., Johansson, G. A., Hertz, H. M. & Birch, J. (2002). Opt. Eng. 41, 2903–2907.  Web of Science CrossRef Google Scholar
First citationMichaelsen, C., Wiesmann, J., Bormann, R., Nowak, C., Dieker, C., Hollensteiner, S. & Jager, W. (2001). Opt. Lett. 26, 792–794.  CrossRef PubMed CAS Google Scholar
First citationSchafers, F., Mertin, M., Abramsohn, D., Gaupp, A., Mertins, H.-Ch. & Salashchenko, N. N. (2001). Nucl. Instrum. Methods Phys. Res. A, 467/468, 349–353.  Google Scholar
First citationSchafers, F., Mertins, H.-Ch., Gaupp, A., Gudat, W., Mertin, M., Packe, I., Schmolla, F., Di Fonzo, S., Soullie, G., Jark, W., Walker, R., Le Cann, X., Nyholm, R. & Eriksson, M. (1999). Appl. Opt. 38, 4074–4079.  PubMed CAS Google Scholar
First citationSchafers, F., Mertins, H.-Ch., Packe, I., Schmolla, I., Salashchenko, N. N. & Shamov, E. A. (1998). Appl. Opt. 37, 719–722.  PubMed CAS Google Scholar
First citationShmaenok, L. A., Golovkin, S. V., Govorun, V. N., Ekimov, A. V., Salashchenko, N. N., Pikalov, V. V., Belik, V. P., Schuller, F. C., Donne, A. J. H., Oomens, A. A. M., Prokhorov, K. A., Andreev, S. S., Sorokin, A. A., Podlaskin, B. G. & Khasanov, L. V. (2001). Rev. Sci. Instrum. 72, 1411–1415.  Web of Science CrossRef CAS Google Scholar

© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.