Figure 7
Dumond diagram representation (energy versus vertical angle) for 81 keVX-rays at various steps of propagation, starting just after the premonochromator and then passing through the collimating CRL and four-reflection high-resolution monochromator, assuming ideal performance of the optics shown in Fig. 6 . |