Top view of the KB mirror system superimposed on the frame architecture of the PF experimental floor. The left-hand side is towards the light source. (a) Before the displacement of the two mirror benders. The grey shadow shows the area where the vibration source had the greatest effect on the vertical mirror bender. (b) After the improvement. Two mirror benders were displaced to the floor frame as indicated by the two arrows.