view article

Figure 2
Schematic view of the LNLS MX2 beamline. Numbers at the top indicate the components as follows: (1) graphite filter; (2, 6, 15) sets of slits; (3) vertical beam-profile monitor and alumina screen; (4) collimating mirror; (5) vertical beam-position monitor; (7) aluminium screen; (8) double-crystal monochromator; (9) beam-intensity monitor; (10) focusing mirror; (11) monochromatic photon shutter; (12) fluorescent screen; (13) attenuators set; (14) quadrant beam-position monitor; (16) goniostat and MarCCD detector. The distances from the optical elements and sample position to the source are indicated at the bottom of the figure.