short communications\(\def\hfill{\hskip 5em}\def\hfil{\hskip 3em}\def\eqno#1{\hfil {#1}}\)

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Volume 16| Part 3| May 2009| Pages 432-434

Synchrotron-based radioscopy employing spatio-temporal micro-resolution for studying fast phenomena in liquid metal foams

CROSSMARK_Color_square_no_text.svg

aEuropean Synchrotron Radiation Facility, 38043 Grenoble Cedex, France, bForschungszentrum Karlsruhe – ANKA, 76021 Karlsruhe, Germany, cTechnische Universität Berlin, 10623 Berlin, Germany, and dHelmholtz Centre Berlin (Hahn-Meitner-Institut), 14109 Berlin, Germany
*Correspondence e-mail: arack@snafu.de

(Received 24 October 2008; accepted 15 January 2009; online 18 March 2009)

Investigations of pore coalescence and individual cell wall collapse in an expanding liquid metal foam by means of X-ray radioscopy with spatio-temporal micro-resolution are reported. By using white synchrotron radiation for imaging, the rupture of a film and the subsequent merger of two neighbouring bubbles could be recorded with a time sampling rate of 40000 frames s−1 (25 µs exposure time) and a spatial sampling rate of 20 µm. The rupture time of a cell wall was found to be in the range of 300 µs. This value is in agreement with theoretical considerations which assume an inertia-dominated rupture time of cell walls in liquid metal foams.

1. Introduction

With his famous high-speed movies, Lucien Bull impressively showed the outstanding scientific value of time-resolved imaging (Bull, 1928[Bull, L. (1928). La Cinématographie. Paris: Armand Collin.]). By using hard X-rays instead of visible light, the application fields of high-speed imaging can be extended to make visible internal structures of opaque objects as they change with time. While even fast periodic movements can be imaged by weak radiation sources via stroboscopic techniques (see e.g. Kardjilov et al., 2005[Kardjilov, N., Hilger, A., Manke, I., Strobl, M., Treimer, W. & Banhart, J. (2005). Nucl. Instrum. Methods Phys. Res. A, 542, 16-21.]), the actual challenge lies in aperiodic movements that require a high density of photons for imaging. Modern third-generation synchrotron light sources with their insertion devices deliver an X-ray photon flux density high enough to perform radiography with micro-resolution in space and time (Di Michiel et al., 2005[Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martin, T. & Svensson, O. (2005). Rev. Sci. Instrum. 76, 043702.]; Uesugi et al., 2006[Uesugi, K., Sera, T. & Yagi, N. (2006). J. Synchrotron Rad. 13, 403-407.]), currently only limited by the available detectors and the time structure of the pulsed synchrotron radiation. Imaging of triggered events using a single light pulse from an undulator source has already been reported (Wang et al., 2008[Wang, Y., Liu, X., Im, K.-S., Lee, W.-K., Wang, J., Fezzaa, K., Hung, D. L. S. & Winkelman, J. R. (2008). Nat. Phys. 4, 305-309.]).

In this paper we introduce high-speed X-ray image sequences (`movies') captured with an image repetition rate of 40000 frames s−1 (FPS), which equals 25 µs exposure time. The movies image continuously the temporal evolution within a foaming metal over a time interval of several seconds. First applications of micro-radiography with a moderate acquisition speed of around 1 FPS to study in situ metal foaming showed the enormous potential of the method as well as a demand for higher acquisition rates (Banhart et al., 2001[Banhart, J., Stanzick, H., Helfen, L. & Baumbach, T. (2001). Appl. Phys. Lett. 78, 1152-1154.]). To measure the rupture time of a cell wall and to access the properties of the constitutive liquid metal in a single film would allow for a better understanding of the stabilization mechanisms. A recent experiment gave indication that highest acquisition rates above 10000 FPS are required for that (García-Moreno et al., 2008[García-Moreno, F., Rack, A., Helfen, L., Baumbach, T., Zabler, S., Babcsán, N., Banhart, J., Martin, T., Ponchut, C. & Di Michiel, M. (2008). Appl. Phys. Lett. 92, 134104.]).

2. Experiments

Experiments with white synchrotron radiation were carried out at the high-flux beamline ID15a of the European Synchrotron Radiation Facility (ESRF), France (Di Michiel et al., 2005[Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martin, T. & Svensson, O. (2005). Rev. Sci. Instrum. 76, 043702.]). The X-ray pixel detector used is based on the indirect detection concept as introduced for live topography (Hartmann et al., 1975[Hartmann, W., Markewitz, G., Rettenmaier, U. & Queisser, H. J. (1975). Appl. Phys. Lett. 27, 308-309.]): a scintillator screen converts X-ray photons into visible light. The resulting luminescence image is optically coupled to a digital camera. In our case, the optical system is an ESRF in-house development allowing for a 1:1 projection of the screen onto the camera (Koch, 1994[Koch, A. (1994). Nucl. Instrum. Methods Phys. Res. A, 348, 654-658.]). As scintillating material, commercially available bulk LuAG:Ce (200 µm thick) was chosen which is known to be suited for fast synchrotron-based imaging involving high heat loads (Di Michiel et al., 2005[Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martin, T. & Svensson, O. (2005). Rev. Sci. Instrum. 76, 043702.]; Touš et al., 2008[Touš, J., Horváth, M., Pína, L., Blažek, K. & Sopko, B. (2008). Nucl. Instrum. Methods Phys. Res. A, 591, 264-267.]; Banhart, 2008[Banhart, J. (2008). Advanced Tomographic Methods in Materials Research and Engineering. Oxford University Press.]). The white beam of the ID15a insertion device was filtered with 25 mm of silicon, leading to an X-ray photon flux density in the range of 1015 photons s−1 mm−2 (ESRF, 2009[ESRF (2009). ID15 High Energy Diffraction and Scattering Beamlines, https://www.esrf.Fr/UsersAndScience/Experiments/MaterialsScience/ID15/ .]). For high-speed data acquisition the novel CMOS camera Photron Fastcam SA-1 was applied (Inoue et al., 2005[Inoue, T., Takeuchi, S. & Kawahito, S. (2005). Proc. SPIE, 5580, 293-300.]). The CMOS chip with 1024 × 1024 pixels (each 20 µm in size) has a peak quantum efficiency of 42% at 640 nm and a ten-bit dynamic range (800:1). One signal unit (ADU) corresponds to a charge of 5.5 electrons in the corresponding potential well of the chip. The camera can acquire 5400 FPS in full-frame mode and up to 675000 FPS when using a region of interest (ROI). The minimal shutter time is 2 µs; the shutter can be triggered with a time resolution of 100 ns. The images as read out are stored in a 32 Gbyte onboard memory which defines the maximum recording length. The movies we show are taken with a ROI to reach 40000 FPS (25 µs exposure time) and an effective pixel size of 20 µm (leading to a spatial resolution R > 40 µm).

Aluminium-based foamable compacts were made following the powder metallurgical route, i.e. by mixing the elemental metal powders with TiH2 acting as blowing agent and pressing these. The precursors were foamed inside a furnace pressurized with argon gas. It consisted mainly of an AlMg1 tube (40 mm diameter and 0.5 mm wall thickness) with a ceramic heating plate inside. The furnace has already been described in more detail previously (García-Moreno et al., 2005[García-Moreno, F., Babcsán, N. & Banhart, J. (2005). Colloids Surf. A, 263, 290-294.]). The coalescence rate during foaming under normal conditions is usually in the range of some events per second in a sample of the size used. To accelerate expansion during the short available time window (a few seconds) and to provide more observable coalescence events, we depressurized the furnace during expansion. Owing to fast expansion of the foam during pressure release, a large number of coalescence events could be recorded.

In summary, the foaming procedure comprised three steps: (i) heating of the precursor under 5 bar pressure, (ii) melting of the precursor and nucleating pores still under pressure, and (iii) fast pressure release from 5 bar to 1 bar, thereby triggering fast foam expansion.

3. Results and discussion

Fig. 1[link] shows a sequence of images, each of which are five or more frames apart, corresponding to 125 µs or more. To demonstrate the features that can be seen much more clearly in the moving image,1 the right-hand column shows the silhouette of two bubbles in the foam that merge to one larger bubble in various stages. (i) The film separating the two bubble is still intact, see Fig. 1(a)[link]. (ii) The film ruptures and is absorbed into the films roughly perpendicular to it, see arrows in Fig. 1(b)[link]. (iii) The merging dumbbell-shaped twin bubble flattens during this absorption (Fig. 1c[link]). The films into which the obsolete film has been sucked are flat 12 ± 3 frames (300 ± 75 µs) after the initiation of rupture [this has been termed `rupture time' previously by García-Moreno et al. (2008[García-Moreno, F., Rack, A., Helfen, L., Baumbach, T., Zabler, S., Babcsán, N., Banhart, J., Martin, T., Ponchut, C. & Di Michiel, M. (2008). Appl. Phys. Lett. 92, 134104.])]. (iv) The two bubbles move together and form a near-spherical unique bubble after another 900 ± 50 µs. (v) The bubble continues to oscillate slowly for some time (Figs. 1d and 1e[link]).

[Figure 1]
Figure 1
Left column: selected images of a series of 184000 showing film rupture in (a) to (c) and bubble oscillation in (d) and (e). Right column: features discussed in the text.

The rupture time measured, 300 µs, can be compared with the larger value of 600 µs obtained by García-Moreno et al. (2008[García-Moreno, F., Rack, A., Helfen, L., Baumbach, T., Zabler, S., Babcsán, N., Banhart, J., Martin, T., Ponchut, C. & Di Michiel, M. (2008). Appl. Phys. Lett. 92, 134104.]). That value corresponded to a bubble with 3 mm diameter, and a lower value is expected here since the rupture time is proportional to the diameter within the simple model presented by García-Moreno et al. (2008[García-Moreno, F., Rack, A., Helfen, L., Baumbach, T., Zabler, S., Babcsán, N., Banhart, J., Martin, T., Ponchut, C. & Di Michiel, M. (2008). Appl. Phys. Lett. 92, 134104.]). Hence, as the diameter of the two bubbles before merger is ∼1.4mm and ∼1.1mm, and that of the merged bubble is ∼1.6mm, the rupture time measured appears to be in the range expected. This finding underlines that the rupture of a single cell wall in a liquid metal foam is dominated by inertia. The oxide particles present in the liquid metal do not prevent the moving metal from being very fluid although they form a network penetrating the entire film (Dudka et al., 2008[Dudka, A., García-Moreno, F., Wanderka, N. & Banhart, J. (2008). Acta Mater. 56, 3990-4001.]). One possible explanation is that the network is disrupted when a film ruptures, during which the apparent melt viscosity sharply drops (García-Moreno et al., 2008[García-Moreno, F., Rack, A., Helfen, L., Baumbach, T., Zabler, S., Babcsán, N., Banhart, J., Martin, T., Ponchut, C. & Di Michiel, M. (2008). Appl. Phys. Lett. 92, 134104.]). This also implies that the viscosity of the melt is not what makes a melt foamable as is often stated (see, for example, Song et al., 2000[Song, Z.-L., Ma, L.-Q., Wu, Z.-J. & He, D.-P. (2000). J. Mater. Sci. 35, 15-20.]).

In conclusion, we could measure a fast phenomenon in liquid metal foam via synchrotron-based radioscopy with spatio-temporal micro-resolution. The technique will allow for the investigation of film rupture in dependence of, for example, alloy composition, content of solid particles, temperature or pore radius. The current experiments only used a fraction of the photon flux density available as the high heat load of the source on the scintillating screen otherwise would irreversibly damage it. Thus, with the ongoing detector development, frame rates above 100000 FPS will soon be feasible.

Supporting information


Footnotes

1Supplementary data for this paper are available from the IUCr electronic archives (Reference: KV5057 ). Services for accessing these data are described at the back of the journal.

Acknowledgements

T. Martin, C. Jarnias, M. Peele, M. Di Michiel (ESRF) and T. dos Santos Rolo, D. Haas, A. Ershov, L. Helfen (ANKA) contributed to the success of this experiment.

References

First citationBanhart, J. (2008). Advanced Tomographic Methods in Materials Research and Engineering. Oxford University Press.  Google Scholar
First citationBanhart, J., Stanzick, H., Helfen, L. & Baumbach, T. (2001). Appl. Phys. Lett. 78, 1152–1154.  Web of Science CrossRef CAS Google Scholar
First citationBull, L. (1928). La Cinématographie. Paris: Armand Collin.  Google Scholar
First citationDi Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martin, T. & Svensson, O. (2005). Rev. Sci. Instrum. 76, 043702.  Web of Science CrossRef Google Scholar
First citationDudka, A., García-Moreno, F., Wanderka, N. & Banhart, J. (2008). Acta Mater. 56, 3990–4001.  Web of Science CrossRef CAS Google Scholar
First citationESRF (2009). ID15 High Energy Diffraction and Scattering Beamlines, https://www.esrf.Fr/UsersAndScience/Experiments/MaterialsScience/ID15/Google Scholar
First citationGarcía-Moreno, F., Babcsán, N. & Banhart, J. (2005). Colloids Surf. A, 263, 290–294.  Google Scholar
First citationGarcía-Moreno, F., Rack, A., Helfen, L., Baumbach, T., Zabler, S., Babcsán, N., Banhart, J., Martin, T., Ponchut, C. & Di Michiel, M. (2008). Appl. Phys. Lett. 92, 134104.  Google Scholar
First citationHartmann, W., Markewitz, G., Rettenmaier, U. & Queisser, H. J. (1975). Appl. Phys. Lett. 27, 308–309.  CrossRef Web of Science Google Scholar
First citationInoue, T., Takeuchi, S. & Kawahito, S. (2005). Proc. SPIE, 5580, 293–300.  CrossRef Google Scholar
First citationKardjilov, N., Hilger, A., Manke, I., Strobl, M., Treimer, W. & Banhart, J. (2005). Nucl. Instrum. Methods Phys. Res. A, 542, 16–21.  Web of Science CrossRef CAS Google Scholar
First citationKoch, A. (1994). Nucl. Instrum. Methods Phys. Res. A, 348, 654–658.  CrossRef CAS Web of Science Google Scholar
First citationSong, Z.-L., Ma, L.-Q., Wu, Z.-J. & He, D.-P. (2000). J. Mater. Sci. 35, 15–20.  Web of Science CrossRef CAS Google Scholar
First citationTouš, J., Horváth, M., Pína, L., Blažek, K. & Sopko, B. (2008). Nucl. Instrum. Methods Phys. Res. A, 591, 264–267.  Google Scholar
First citationUesugi, K., Sera, T. & Yagi, N. (2006). J. Synchrotron Rad. 13, 403–407.  Web of Science CrossRef IUCr Journals Google Scholar
First citationWang, Y., Liu, X., Im, K.-S., Lee, W.-K., Wang, J., Fezzaa, K., Hung, D. L. S. & Winkelman, J. R. (2008). Nat. Phys. 4, 305–309.  Web of Science CrossRef CAS Google Scholar

This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Volume 16| Part 3| May 2009| Pages 432-434
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds