Figure 6
Three-dimensional plot of first right singular vectors for all 12 short time-series shown as a function of dose. D1/2K is reached after 36 datasets or four short time-series. The offsets in the RVS are indicated by the dotted lines. Green dotted line: small offsets; orange dotted line: offset increases slightly; red dotted line: offset increases strongly. The orange regime ends after 72 datasets. The red line indicates that posterior analysis of the data beyond this dose will not be possible. D1/2 is also indicated. (b) Three-dimensional plot of all fitted time courses from the posterior analysis as a function of dose. The green, orange and red regimes as well as the approximate relaxation times that can be expected in these regimes are marked. D1/2K, D1/2 as well as Owen's limit are also shown.