research papers
Exploration of synchrotron Mössbauer microscopy with micrometer resolution: forward and a new backscattering modality on natural samples
aDepartment of Chemistry, University of California, Davis, CA 95616, USA, bX-ray Sciences Division, Argonne National Laboratory, Argonne, IL 60439, USA, cCenter for Nanoscale Materials, Argonne National Laboratory, Argonne, IL 60439, USA, dBiosciences Division, Argonne National Laboratory, Argonne, IL 60439, USA, eDepartment of Earth and Planetary Sciences, American Museum of Natural History, New York, NY 10024, USA, fDepartment of Geological Sciences, Brown University, Providence, RI 02912, USA, and gDepartment of Chemistry, Fordham University, Bronx, NY 10458, USA
*Correspondence e-mail: eea@aps.anl.gov
New aspects of synchrotron Mössbauer microscopy are presented. A 5 µm spatial resolution is achieved, and sub-micrometer resolution is envisioned. Two distinct and unique methods, synchrotron Mössbauer imaging and nuclear resonant incoherent X-ray imaging, are used to resolve spatial distribution of species that are chemically and magnetically distinct from one another. Proof-of-principle experiments were performed on enriched 57Fe phantoms, and on samples with such as meteorites.
Keywords: synchrotron Mössbauer microscopy; nuclear resonant incoherent X-ray imaging; meteorite; 57Fe phantom; 5 µm resolution.
1. Introduction
Synchrotron-based nuclear ; Smirnov, 1999; Alp et al., 1995; Lübbers et al., 1999; Hastings et al., 1991) and nuclear resonant vibrational spectroscopy (NRVS) (Sturhahn, 2004; Chumakov & Rüffer, 1998; Alp et al., 2001; Smith et al., 2005; Seto et al., 1995; Sturhahn et al., 1995), involve nuclear resonant transitions of Mössbauer nuclei excited by synchrotron radiation. These techniques are sensitive to the chemical environment of Mössbauer isotopes, and have been effective tools for studying the magnetic and chemical structure of materials, inorganic and organic, crystalline and amorphous alike.
techniques, such as synchrotron Mössbauer spectroscopy (SMS) (Sturhahn, 2004Conventional Mössbauer microscopy (Yoshida et al., 2009) and synchrotron Mössbauer microscopy (Mitsui et al., 2004) have been introduced previously. Here we report new aspects of synchrotron Mössbauer microscopy including micrometer spatial resolution, forward as well as backscattering geometry, and the ability to measure samples with such as meteorites. There are two distinct and unique signals that are available to resolve the spatial distribution of Mössbauer isotope-containing species. These are:
(i) Synchrotron Mössbauer spectroscopy imaging (SMS imaging), which collects coherent nuclear
signal in the forward direction, and yields information based on hyperfine interactions of the nuclei in the solid;(ii) Nuclear resonant incoherent X-ray imaging (NRIX imaging), which collects incoherent nuclear π direction, could provide lattice dynamics information, and allows study of thick samples like natural rocks.
in the 4In both SMS imaging and NRIX imaging the time-integrated signal can be recorded point by point to reveal the distribution of Mössbauer isotope species. Then getting closer to the interesting spots, with SMS imaging, the time-dependent spectrum can reveal hyperfine interactions, leading to information about the magnetic, valence and spin state of the system, and local atomic symmetry. With NRIX imaging, by tuning the incident X-ray energy off nuclear resonance in the 100 meV range, the energy spectrum of phonon excitation probability density could reveal phonon density states, average force constant and ).
This latter information can be converted to identify isotope fractionation ratios (Polyakov, 2009We performed the proof-of-principle experiments by employing the instruments at beamline 3-ID at the Advanced Photon Source (APS), Argonne National Laboratory (ANL). Excellent signal-to-noise ratio is achieved. Resolution to 5 µm has been achieved, and sub-micrometer is envisioned. Synchrotron-radiation-based nuclear
spectroscopy offers greater applicability by further reducing the beam size to commensurate with the needs of diverse experiments of interest in biology, mineralogy, paleomagnetism, geochemistry, and the synthesis of new materials under high pressure.2. Technique related
2.1. Experimental set-up
Fig. 1 shows the set-up for SMS imaging and NRIX imaging at beamline 3-ID at APS. The sample was placed on a movable stage. The broadband X-ray beam, produced from a 4.8 m-long 2.7 cm-period undulator, is monochromated through two stages. The primary high-heat-load monochromator (HHLM) consists of a pair of high-quality artificial diamond (1 1 1) single crystals with (+ −) arrangement, which reduces the X-ray bandwidth to the eV order around the nuclear resonant energy. The second stage uses a high-resolution monochromator (HRM), by which the X-ray beam is monochromated further to meV bandpass. Each HRM is specifically designed for a specific isotope. For the 57Fe isotope, an X-ray beam of 14.4 keV is produced from the undulator in the first harmonic; after HHLM the X-ray bandwidth is reduced to 1.1 eV; the HRM used for the 57Fe isotope consists of two Si (4 0 0) followed by two Si (10 6 4) crystal reflections with an `in-line' (+ − − +) scattering geometry, which gives 1 meV resolution at 14.4125 keV (Toellner, 2000).
Kirkpatrick–Baez (KB) mirrors are used to focus the X-ray beam (Eng et al., 1998), and an additional pinhole is used to reduce the beam size further (Fischetti et al., 2009). The KB arrangement mirrors are two elliptically bent mirrors, which are orthogonal to each other, and can individually focus the beam in the vertical and horizontal directions. The size of the X-ray beam focused onto the sample stage without the pinhole was 20 µm × 18 µm (FWHM in horizontal and vertical directions separately). A pinhole with 5 µm diameter was placed right before the sample (∼2 mm) to reduce the spot size. The parameters for the synchrotron source and components are shown in the supplementary information.1 In our experiment we use the 57Fe isotope, so all the parameters in this paper are selected for this purpose. The before the pinhole is 2 × 109 photons s−1 in 1 meV bandwidth, and immediately after the pinhole it is 6 × 107 photons s−1. The storage ring operation mode at APS is 24 single bunches, with a time spacing of 153 ns. The of the first nuclear of 57Fe is 141 ns. So this mode is adequate for 57Fe-containing materials or samples containing isotopes with suitable decay times such as 83Kr, 119Sn, 151Eu and 161Dy.
As shown in Fig. 1, two Si-based detectors (APDs) are used to collect the nuclear signal. One is placed in the forward direction to measure in transmission geometry, and the other is placed on the side to collect part of the 4π incoherent but The nuclear signal is discriminated from other forms of scattering in the time domain, as electronic scattering processes are on the timescale of a picosecond or faster (`prompt'). The at the APS is less than 100 ps, while the nuclear signal is on the timescale of 100 ns (`delayed'). APDs are employed due to their fast time resolution (ns) and large of 108 (Baron & Ruby, 1994; Toellner et al., 1994; Baron, 2000; Kikuta et al., 1991). The typical time resolution of an APD using a 10 mm × 10 mm area silicon diode is about 1 ns (Baron, 2000). Based on the current set-up and taking into account the shape of the APD output signal, time distribution of the APD output pulses and bunch purity in the storage ring, the starting time for detecting the delayed signal is usually set to around 20 ns. The APD efficiency could be enhanced by rotating it to increase the effective thickness of Si.
In the forward direction the APD collects the coherent nuclear CONUSS program (Sturhahn, 2000)]. With another APD placed on the side and very close to the sample, we collect the delayed incoherent nuclear resonant-induced iron K-edge fluorescence signal of 6.4 keV in a large solid angle. In the latter mode, if we stay on the resonant energy, the detected signal can be used to determine the spatial distribution of iron-containing grains. If we tune the incident beam in the range ±100 meV around the nuclear resonant energy with a HRM, we could record an energy spectrum of the phonon excitation probability. From these data the phonon can be extracted [for example, by employing the PHOENIX program (Sturhahn, 2000)]. Both the time spectrum and the phonon provide very unique spectroscopic characters to this X-ray-based microscope.
signal. The hyperfine parameters could be extracted from the decayed time spectrum [for example, using the2.2. Phantom preparation
As a proof-of-principle experiment, we have prepared phantom samples to check the validity and sensitivity of this new imaging modality. The 57Fe phantom preparation was carried out at the Center for Nanoscale Materials (CNM) at ANL, as follows:
(i) 500 µm-thick silicon wafers were used [p-type, single-side polished, (100), 1–10 Ω cm], which were cut into 1.5 cm × 1.5 cm pieces. The samples were cleaned with a 4:1 (v/v) mixture of sulfuric acid (95%, ACS reagent grade, Acros Organics) and hydrogen peroxide (30%, ACS reagent grade, Ricca Chemical) for 10 min. The samples were carefully rinsed with 17.5 MΩ cm-resistivity de-ionized water (DIW) and dried with nitrogen and annealed on a hot plate at 473 K for 5 min.
(ii) A thin layer of metal such as Cr (5 nm) and Au (30 nm) was deposited as plate base on the polished side with a Lesker PVD-250 electron-beam evaporator with a Sigma deposition controller. The films were evaporated at room temperature, with a base pressure of 2 × 10−8 torr at a deposition rate of 2 Å s−1.
(iii) Positive resist S1813 (Microchem) of 1.5 µm was spin coated at 3000 r.p.m. and baked on a hot plate at 288 K for 1 min.
(iv) Exposure with a laser writer LW405 Microtech (GaN laser of 400 nm wavelength) and development for 30 s in 351 developer (Microchem), diluted 1 to 3 in DIW. The resist structure is used as a mold for plating.
(v) Electroplating in 50 mM 57FeCl2 solution.
(vi) To prepare the FeCl2 solution, 120 mg 57Fe powder was dissolved in 0.4 ml HCl (37%), and then DIW was added (42 ml). By heating on a hot plate at 373 K for several hours, its color turned from colorless to light orange, and then to yellow. As pure FeCl2 solution should be light green to colorless, we think the solution might be a mixture of FeCl2 and FeCl3. The deposition was performed at 323 K with a of 1.8 mA cm−2 for a deposition rate of ∼0.6 µm min−1.
(vii) The resist was removed with acetone.
We produced several 57Fe-coated phantoms for imaging study. One pattern had an area of 150 µm × 150 µm, with characters 15 µm wide. Another one was 450 µm × 450 µm with characters of width 45 µm.
2.3. Theoretical calculation
in the forward direction, without hyperfine splitting of the nuclear resonance, the intensity could be calculated theoretically using the equation given below (Smirnov, 1999where I0 is the incident intensity of the synchrotron radiation, ΔE is the energy bandwidth determined by HRM, Γ is the natural width of the nuclear while the characteristic t0 = . z is the X-ray penetration length in the sample, and J1 is the first-order Bessel function. μe is the photo-electronic in the target. μ = σ0fβn is the at resonance, where σ0 is the nuclear resonant absorption f is the Lamb–Mössbauer factor representing the probability for recoilless absorption, β is the and n is the of nuclear resonant isotopes. q describes a broadening of the resonance (Smirnov, 1996).
Depending on the hyperfine interaction, the degenerated ω1 and ω2, the forward-scattering intensity from a thin layer will be (Smirnov, 1999)
will be split into sublevels. There will be multiple nuclear resonances, and the interference between them yields quantum beats. For simplicity, with only two nuclear resonance componentsFor incoherent nuclear scattering in the 4π direction, the detected intensity could be modeled as (Hu, 1999)
where R(E) is the energy resolution function of the HRM and σ(E) is the energy-dependent nuclear absorption η is the total which includes the detector efficiency, solid angle, internal conversion of nucleus decay, of the K shell, etc.
To estimate, let R(E′ − E) = 1/ΔE only for a small area as |E′ − E| < ΔE/2, otherwise it vanishes. With simple integration of thickness z, we can simplify the equation as
For the elastic peak in the incoherent nuclear
its is given bywhich is much larger than that of electronic scattering.
For the inelastic part of the incoherent nuclear resonant scattering,
where ΘD is the Debye temperature. The off-resonant nuclear absorption is much smaller than the electronic scattering
Usually the elastic peak is much stronger than the inelastic signal for materials with a
higher than 10%.3. Measurement results
3.1. Phantom-based proof-of-principle test
3.1.1. SMS imaging and time spectrum
The first 57Fe phantom we tested had an average thickness of 0.7 µm, with a 150 µm × 150 µm pattern, and width of characters 15 µm. The phantom faced downstream, and one APD was placed in the forward direction. The SMS image was collected (Fig. 2) and the time spectrum at selected locations was also collected (Fig. 3). In this measurement the KB mirror and pinhole were both used to reduce the spatial resolution to 5 µm.
As shown in Fig. 2, the characters in this phantom are displayed clearly with good contrast. Two cross-sectional views are shown on the right-hand side, which display excellent signal-to-noise ratio and indicate the feasibility of studying samples with dilute concentration. The data collection time was 1 s per point, with a step size of 2.5 µm in both directions. The total image was collected in 2 h. During this process the incident energy was kept on resonance within ±0.2 meV.
Fig. 3 shows the time spectrum collected at a spot in the character `N'. In a time window between 23 and 120 ns the detected delayed signal at this spot was 120 counts s−1. The delayed time spectrum was fitted using CONUSS (Sturhahn, 2000). The expected thickness at this spot on the letter `N' was 1.0 µm, and the internal magnetic field was simulated to be 33.14 T. Also with CONUSS the time-integrated delayed transmission in this time window was calculated as 7.71Γ0, where Γ0 = 4.67 neV is the natural width of the 57Fe nuclear The electronic absorption is included. With the incident as 6 × 107 photons s−1 in 1 meV width, considering other factors such as detector efficiency, electronic absorption, etc. (listed in Table 1), we could expect the time-integrated delayed to be 360 photons s−1, which is close to the detected signal. The APD absorbed prompt photon dose is calculated to be 9.7 × 106 photons s−1, while the total measured APD was 5.18 MHz. This discrepancy can be best understood by realising that at high counting rates the APD performs non-linearly (Toellner et al., 1994).
|
To guide future experiments, we estimate the theoretical counting rates for two kinds of samples under current conditions with 5 µm resolution. Suppose the APD is set at 85° from normal incidence to optimize its efficiency. With a 0.1 µm 57Fe layer on top of a 250 µm Si wafer, we could expect a delayed signal of 20 photons s−1. Under these conditions the prompt photon dose absorbed by the APD will be around 2.4 × 107 photons s−1. For a 10 µm layer of natural Fe on top of a 250 µm Si wafer, we could expect 50 photons s−1 as delayed signal, and an absorbed prompt photon dose of approximately 1.4 × 107 photons s−1.
3.1.2. NRIX versus SMS imaging
The second 57Fe phantom we chose had an average thickness of 0.6 µm with a pattern area of 450 µm × 450 µm and character width 45 µm. NRIX imaging and SMS imaging were recorded at the same time (Fig. 4). Only KB mirrors were used to focus the beam without a subsequent pinhole. The phantom faced upstream and had an angle of ∼55° between the X-ray and surface normal. One dimension was shortened because of the rotation. The total data were collected in 40 min, again by scanning 1 s per point, and the step size was 10 µm in both directions.
Fig. 4 shows that, at the same spot, NRIX imaging has a five times larger signal than SMS imaging. This proves the feasibility of imaging thick samples such as rocks and minerals using the NRIX set-up. This is a salient feature, and makes sample preparation easier, especially for mineralogical or biological samples. We did not record the phonon excitation probability density spectrum with this phantom as it is just pure Fe. However, there is no doubt about this capability, as NRIX at beamline 3-ID is quite a mature technique.
Estimations for both the . The calculated delayed signal was 1150 photons s−1, with a photon dose absorbed by the APD of 2.7 × 107 photons s−1. At such a high dose APD counting will be saturated (see §4.1). Experimentally we introduced an aluminium absorber to reduce it by an approximate factor of 3. The delayed signal was also reduced by the same factor. The detected APD was 5 × 106 counts s−1, with the maximum detected delayed signal 300 counts s−1.
and incoherent scatting were made. The parameters for the of the second phantom are listed in Table 1In Table 2 the parameters that influence the for were estimated. By employing the HRM resolution function as 1 meV, the numerical integration of equation (4) tends to I(E ≃ 0) = ηI0 × 3.41 × 10−5, with sample thickness 1.1 µm. Taking I0 = 1.5 × 109 photons s−1 meV−1 and taking all the efficiency estimations in Table 2, we found the delayed signal in the direction to be ∼1600 photons s−1, which matches the detected signal well.
|
3.1.3. Comparison with microscope
In order to obtain an idea about the effectiveness of our newly introduced imaging methods, we performed 9 photons s−1, and the incident energy was 10.1 keV, with a bandwidth of 2 eV. The collecting channel was set to the Kα fluorescence of Fe, which is 6.4 keV. The step size was 1.0 µm, the scan area was 170 µm × 170 µm, and the collection time was 0.5 s per point. The image is shown in Fig. 5. The averaged background is 80 counts in 0.5 s. (The black line in the `U' and `C' was caused by temporary beam loss.)
imaging on the #1 phantom at beamline 2-ID-D at APS. The beam was focused by a zone plate to 0.2 µm at the sample position. A pinhole with 20 µm diameter was placed before the sample to cut off the beam tails. The before the sample was 1.27 × 10It is clear that
imaging achieves a higher with higher resolution. This is because it makes use of the full energy bandwidth of the incident beam which allows for much larger within a smaller focal spot. Even with this, there are still applications that can benefit from synchrotron Mössbauer imaging despite the low counting rates. As mentioned earlier, SMS imaging and NRIX imaging utilize the properties of nuclear resonant X-ray scattering, and have advantages in distinguishing magnetic properties, valence states, chemical structures and also in the determination of the phonon With the development of instrumentation and synchrotron sources, there is still potential to increase the delayed signals over the results obtained here.3.2. Meteorite sample test
Some meteorite samples were tested with our nuclear resonant microscope. We show here an image of a petrographic thin section of the Estacado H6 chondrite (Fig. 6) as a proof-of-principle test. The Estacado sample was obtained from the American Museum of Natural History, and bears the name of its find location: Llano Estacado, Hale County, Texas, USA. A standard petrographic section of thickness 30 µm with 1 mm glass backing was imaged. The left-hand panel of Fig. 6 shows a comparison of (a) the SMS image and (b) its contour plot, with (c) its optical image. Three typical time domain spectra are displayed in the right-hand panel, which correspond to three grains as indicated. By fitting with CONUSS, we found the parameters for these three grains as (d) H = 16.3 T, QS = 1.29 mm s−1; (e) H = 33.7 T, QS = 0.133 mm s−1; (f) H = 31 T, QS = 0.35 mm s−1. They were assigned to an iron–sulfur compound, kamacite (Fe, Ni alloy) and troilite (FeS) separately.
4. Current limits and new methods
4.1. APD limit
Our APD set-up only produces one count from each electronic bunch. However, usually there is more than one photon absorbed from each bunch. When μ, the mean number of photons absorbed per bunch by the APD, exceeds 1, the ability to discriminate delayed photons begins to diminish. For the APS 24-bunch mode, μ > 2 occurs when the prompt photon absorption dose in the APD exceeds approximately ∼1.3 × 107 photons s−1 (Toellner et al., 1994). Under current conditions we usually set the starting time of the `delayed' time window around 20 ns, so that this absorption dose does not adversely affect the time-discrimination capability. For such a photon absorption dose, the corresponding APD prompt is ∼5.6 × 106 counts s−1. Even higher doses result in more deterioration of time-discrimination capability, and then it is necessary to reduce this either through the use of an absorber or a pinhole. The necessity to limit the prompt by using an absorber or pinhole artificially reduces the delayed as well. This is an inevitable issue for forward-scattering signals. The APD signal from the 4π scattering will not suffer from this problem, as its prompt absorption dose is much less.
4.2. Envision of 1 µm resolution
With the 5 µm pinhole, the
incident on the sample was reduced by a factor of 25. This resulted in no loss of delayed signal owing to the fact that it allowed removal of an absorber at the same time. By employing a 1 µm pinhole, the incident will be reduced by an additional factor of 25, but the delayed signal will also be affected by this factor. Using better focusing optics instead of a 1 µm pinhole would allow a better resolution without significant loss of delayed signal.4.3. New methods under development
There are some ways to circumvent or decrease the huge prompt photon absorption dose, while not affecting the delayed signal rates. One involves high-speed shuttering (Toellner et al., 2011b) which would substantially reduce problems associated with excessive photon absorption rates in the APD. If a high-speed shutter is placed directly before an APD to block the prompt signal, the time-discrimination capability of the APD will not be diminished, thus leading to substantially higher delayed signal rates. One to two orders of magnitude might be expected. Furthermore, using a high-speed shutter would allow other detectors with higher efficiency to substitute the APD. However, as a high-speed shutter requires a very small X-ray beam between sample and detector, it is not practical in the NRIX imaging mode.
Another method involves the development of an ultrahigh-resolution X-ray monochromator. The 57Fe has 1 meV bandwidth, filters out broadband photons and has an efficiency of 25% at 14.4125 keV, the 57Fe energy. The under-developing high-efficiency ultrahigh-resolution monochromator is expected to have sub-meV bandwidth, and could throw away even more broadband photons (Toellner et al., 2011a). With a sub-meV HRM, for the APD could have a broader time window and collect more signal; for incoherent nuclear higher energy tunability could be achieved.
width is of the order of neV. Only photons in this narrow energy range interact with Mössbauer isotope nuclei. Other photons just pass through the sample, resulting in a rather high prompt absorption dose on the APD, which limits the starting time window of the APD. Our current HRM forA multi-element APD (Baron et al., 2006) is also a good option. With a multi-element APD placed in grazing incidence, the prompt will be distributed amongst the individual elements. Good time resolution and high efficiency can be achieved in the forward direction with this method. For the incoherent nuclear resonant 4π scattering, more signal could be collected owing to a larger solid angle accepted by a multi-element APD.
5. Future use
By using these phantoms and a chondritic meteorite sample, we have demonstrated the basic imaging capability of our nuclear resonant microscope, and assessed the practical aspects of such an instrument. We have explored the viability of imaging Fe species. Besides 57Fe, this technique can be equally applied to half a dozen other isotopes such as Sn, Dy, Eu, Sm, Sb and Kr. We had success in applying this method to other mineralogical samples, and further results will be presented in another paper.
With these imaging techniques it is possible to image biological samples without radiation damage. For the SMS and NRVS measurements there is no obvious radiation damage that has been detected on biological samples at cryogenic temperature. In these techniques the focused beam 13 photons s−1 mm−2 in 1 meV bandwidth. According to previous studies of radiation damage in biological samples at cryogenic temperatures (Nave, 1995; Teng & Moffat, 2000; Sliz et al., 2003), there are two principal processes of concern: energy deposition caused by photoelectric absorption, and radical reactions induced by thermal diffusion. In our imaging techniques, 14.4 keV X-rays produce modest photoelectric absorption in biological samples, and, with the less than 1015 photons s−1 mm−2, there is both negligible sample heating and insignificant thermal diffusion.
reaches as high as 10There is potential to increase the nuclear resonant signal while decreasing the total X-ray
on the sample, by improving the monochromator, or with other improvements such as a high speed shutter. Because only X-rays within the nuclear resonant energy width contribute to the signal, such improvements in the experimental set-up will enhance the measured signal while decreasing, or leaving unchanged, the risk of radiation damage.Acknowledgements
We would like to thank Daniel Rosenmann for depositing Cr/Au on the phantoms, and thank Michael Y. Hu for valuable discussions that improved this article. The work at Sector 3 was supported in part by the Consortium for Materials Properties Research in Earth Sciences under NSF Cooperative Agreement EAR 06-49658. The work was also in part funded by NIH grant GM-65440 (SPC) in the University of California, Davis, under a collaboration contract with ANL cost code 58927-30-132. Use of the APS and the CNM at Argonne National Laboratory was supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. DE-AC02-06CH11357.
References
Alp, E. E., Sturhahn, W. & Toellner, T. (1995). Nucl. Instrum. Methods Phys. Res. B, 97, 526–529. CrossRef CAS Web of Science Google Scholar
Alp, E. E., Sturhahn, W. & Toellner, T. S. (2001). J. Phys. Condens. Matter, 13, 7645–7658. Web of Science CrossRef CAS Google Scholar
Baron, A. Q. R. (2000). Hyperfine Interact. 125, 29–42. Web of Science CrossRef CAS Google Scholar
Baron, A. Q. R., Kishimoto, S., Morse, J. & Rigal, J.-M. (2006). J. Synchrotron Rad. 13, 131–142. Web of Science CrossRef CAS IUCr Journals Google Scholar
Baron, A. Q. R. & Ruby, S. L. (1994). Nucl. Instrum. Methods Phys. Res. A, 343, 517–526. CrossRef CAS Web of Science Google Scholar
Chumakov, A. & Rüffer, R. (1998). Hyperfine Interact. 113, 59–79. Web of Science CrossRef CAS Google Scholar
Eng, P. J., Newville, M., Rivers, M. L. & Sutton, S. R. (1998). Proc. SPIE, 3449, 145–156. CrossRef Google Scholar
Fischetti, R. F., Xu, S., Yoder, D. W., Becker, M., Nagarajan, V., Sanishvili, R., Hilgart, M. C., Stepanov, S., Makarov, O. & Smith, J. L. (2009). J. Synchrotron Rad. 16, 217–225. Web of Science CrossRef CAS IUCr Journals Google Scholar
Hastings, J. B., Siddons, D. P., van Bürck U., Hollatz, R. & Bergmann, U. (1991). Phys. Rev. Lett. 66, 770–773. Google Scholar
Hu, M. Y. (1999). PhD thesis, Northwestern University, Evanston, Illinios, USA. Google Scholar
Kikuta, S., Yoda, Y., Kudo, Y., Izumi, K., Ishikawa, T., Suzuki, C. K., Ohno, H., Takei, H., Nakayama, K., Zhang, X. W., Matsushita, T., Kishimoto, S. & Ando, M. (1991). Jpn. J. Appl. Phys. 30, L1686–L1688. CrossRef CAS Google Scholar
Lübbers, R., Wortmann, G. & Grünsteudel, H. F. (1999). Hyperfine Interact. 123/124, 529–559. Google Scholar
Mitsui, T., Kobayashi, Y. & Seto, M. (2004). Jpn. J. Appl. Phys. 43, 389–393. Web of Science CrossRef CAS Google Scholar
Nave, C. (1995). Radiat. Phys. Chem. 45, 483–490. CrossRef CAS Web of Science Google Scholar
Polyakov, V. B. (2009). Science, 323, 912–914. Web of Science CrossRef PubMed CAS Google Scholar
Seto, M., Yoda, Y., Kikuta, S., Zhang, X. W. & Ando, M. (1995). Phys. Rev. Lett. 74, 3828–3831. CrossRef PubMed CAS Web of Science Google Scholar
Sliz, P., Harrison, S. C. & Rosenbaum, G. (2003). Structure, 11, 13–19. Web of Science CrossRef PubMed CAS Google Scholar
Smirnov, G. V. (1996). Hyperfine Interact. 97/98, 551–588. CrossRef CAS Web of Science Google Scholar
Smirnov, G. V. (1999). Hyperfine Interact. 123/124, 31–77. Web of Science CrossRef Google Scholar
Smith, M. C., Xiao, Y., Wang, H., George, S. J., Coucouvanis, D., Koutmos, M., Sturhahn, W., Alp, E. E., Zhao, J. & Cramer, S. P. (2005). Inorg. Chem. 44, 5562–5570. Web of Science CrossRef PubMed CAS Google Scholar
Sturhahn, W. (2000). Hyperfine Interact. 125, 149–172. Web of Science CrossRef CAS Google Scholar
Sturhahn, W. (2004). J. Phys. Condens. Matter, 16, S497–S530. Web of Science CrossRef CAS Google Scholar
Sturhahn, W., Toellner, T. S., Alp, E. E., Zhang, X., Ando, M., Yoda, Y., Kikuta, S., Seto, M., Kimball, C. W. & Dabrowski, B. (1995). Phys. Rev. Lett. 74, 3832–3835. CrossRef PubMed CAS Web of Science Google Scholar
Teng, T. & Moffat, K. (2000). J. Synchrotron Rad. 7, 313–317. Web of Science CrossRef CAS IUCr Journals Google Scholar
Toellner, T. S. (2000). Hyperfine Interact. 125, 3–28. Web of Science CrossRef CAS Google Scholar
Toellner, T. S., Alatas, A. & Said, A. H. (2011a). J. Synchrotron Rad. 18, 605–611. Web of Science CrossRef CAS IUCr Journals Google Scholar
Toellner, T. S., Alp, E. E., Graber, T., Henning, R. W., Shastri, S. D., Shenoy, G. & Sturhahn, W. (2011b). J. Synchrotron Rad. 18, 183–188. Web of Science CrossRef CAS IUCr Journals Google Scholar
Toellner, T. S., Sturhahn, W., Alp, E. E., Montano, P. A. & Ramanathan, M. (1994). Nucl. Instrum. Methods Phys. Res. A, 350, 595–600. CrossRef CAS Web of Science Google Scholar
Yoshida, Y., Suzuki, K., Hayahawa, K., Yukihira, K. & Soejima, H. (2009). Hyperfine Interact. 188, 121–126. CrossRef CAS Google Scholar
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.