q2xafs workshop
Time-resolved
(Bonn-SUT-SLRI) beamline at SLRIaSynchrotron Light Research Institute, Nakhon Ratchasima 30000, Thailand, bNanomaterials Science Program, Faculty of Science, Kasetsart University, Bangkok 10903, Thailand, cDepartment of Chemistry, Faculty of Science, Kasetsart University, Bangkok 10903, Thailand, dCanadian Light Source, University of Saskatchewan, 101 Perimeter Road, Saskatoon, SK, Canada S7N OX4, and eSchool of Physics, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
*Correspondence e-mail: prayoon@slri.or.th
An energy-dispersive X-ray absorption spectroscopy beamline has been constructed at the Synchrotron Light Research Institute, Thailand. The beamline was designed to utilize the synchrotron radiation with photon energies between 2400 and 8000 eV. The horizontal focusing of the bent crystal in the energy-dispersive monochromator offers a small polychromatic focal spot of 1 mm at the sample position. By employing an energy-dispersive scheme, the whole X-ray absorption near-edge structure (XANES) can be obtained simultaneously using a position-sensitive detector with a fastest readout speed of 25 ms. The short data collection time opens a new opportunity for time-resolved in situ cell was designed and fabricated for the beamline. Thermal oxidation of TiO2 was chosen as an in situ experiment example. The structural change of TiO2 as a function of temperatures was monitored from the change in the measured spectra. The obtained Ti K-edge XANES spectra clearly show the formation of an anatase phase when the temperature was raised to 673 K.
experiments such as studies of changes of the electronic structures or the local coordination environments of an atom during a change in thermodynamic conditions. For this purpose, anKeywords: time-resolved XAS; energy dispersive; in situ measurement; TiO2.
1. Introduction
; Hedman & Pianetta, 2007; Bunker, 2010, and references therein). In a conventional set-up an spectrum measurement involves a mechanical scanning of a double-crystal monochromator (DCM). This limits the data acquisition time to several minutes. Thus, it is not possible to monitor rapid changes of local structures or valence states of some processes such as the change in the valence state of Fe(III) porphyrin during a (Chen et al., 1999) and the change of Fe neighboring atoms during a dissociation of ferrioxalate (Chen et al., 2007), processes that take place within 10 ms and 115 ps, respectively. To overcome this problem, two schemes to increase the data collection speed have been proposed. For the first scheme, called the quick-scanning (QEXAFS), a typical DCM is replaced by a piezo-driven (Lützenkirchen-Hecht et al., 2001) or a cam-driven DCM (Caliebe et al., 2006) and an spectrum can be measured in milliseconds. The second scheme is to use an energy-dispersive set-up (Flank et al., 1983; Blank et al., 1992; Pascarelli et al., 1999; Cezar et al., 2010), which allows the whole XANES spectrum to be measured simultaneously, and the data collection speed is mainly limited by the electronics of the detector which is typically in the range of a millisecond or microsecond.
has been widely used to determine valance states or local structures of various materials (Koningsberger & Prins, 19882. Energy-dispersive set-up
In an energy-dispersive shows a schematic diagram for the EDXAS set-up. For simplicity, it may be considered that the crystal is bent to a cylindrical shape with a radius of curvature R. The relation between the source-to-crystal distance (p) and the crystal-to-focus distance (q) for the bent crystal follows an equation for cylindrical optics, which is
(EDXAS) set-up a bent crystal is employed to disperse and focus X-rays with a continuous band of photon energies. Fig. 1where θ is the At a certain the usable energy range is given by
where l is an illuminated length on the crystal and Δθ is a range of incident angles with respect to the crystal surface.
Using the energy-dispersive scheme, et al., 1987). A number of researches have been made using the EDXAS set-up. These include the study of the Cu2+ → Cu+ transformation in a cathodic reduction of Cu in conductive polymers (Dartyge et al., 1986) where Cu K-edge XANES spectra were measured every 7.2 s, the investigation of a thermal dehydration process in a Ni2+ ion exchanged zeolite Y (Couves et al., 1990) using Ni K-edge XANES, and the crystallization of some nanomaterials (Meneses et al., 2006).
spectra can be obtained with less vibration-induced noise compared with the conventional set-up as there are no mechanical movements during the measurements, the beam size at the sample position can be small which allows small samples to be measured, and a good output-linearity and a wide of a position-sensitive detector (PSD) gives good signal-to-noise ratio data and a fast detection speed (Fontaine3. TRXAS beamline
The time-resolved θ arm with an angular range from 20 to 140° which were donated by the University of Bonn, Germany. The components belonged to a decommissioned beamline at the Electron Stretcher and Accelerator (ELSA) of the University of Bonn (Blank et al., 1992). With a Si(111) crystal, the EDM covers photon energies between 2400 and 8000 eV, allowing the K-edges of S to Co to be investigated at this beamline. The rest of the beamline components were designed and fabricated in-house.
(TRXAS) beamline is designed to utilize synchrotron radiation generated from a bending magnet of a 1.2 GeV storage ring of the Siam Photon Source. It employs an energy-dispersive monochromator (EDM) and a 2Because of the requirement for low-energy X-rays, no Be window was used to separate the vacuum between the storage ring and the beamline. Instead, a pressure-reduction tube was installed to connect the ultra-high-vacuum level (2 × 10−10 torr) at the front-end to a high vacuum level (1 × 10−6 torr) in the EDM (Fig. 2). However, since there is no cooling to the bent crystal in the EDM, a water-cooled 25 µm-thick Be foil was placed upstream of the EDM to reduce the heat load dissipated on the crystal from the white-beam radiation. Without the Be foil, the power dissipating on the crystal is about 4.7 W at 100 mA of stored beam. When the Be foil is inserted into the optical path, about 60% of the power is absorbed by the foil. The reduction of the owing to the Be foil measured by an was 5% at 5 keV photon energy. The reduction of the is higher at lower photon energies. Thus, the Be foil is installed on a linear drive, allowing the Be foil to be retracted from the optical line when measuring K-edge absorption spectra of light elements such as sulfur. Upstream of the EDM there are four pairs of water-cooled slits used to adjust the size of the beam entering the EDM and two wire-type photon beam position monitors to determine the profile of the beam horizontally and vertically.
The rectangular-shape Si(111) crystal with an area of 25 mm × 250 mm and a thickness of 1 mm was used as a bent crystal. The elliptical curvature of the crystal is adjustable using a crystal bender which is mounted on a three-axis goniometer placed inside the monochromator chamber. The goniometer allows the crystal to be rotated around three axes and translated vertically. The axes of rotation are the vertical axis, the axis normal to the crystal surface, and the axis along the length of the crystal. The distance between the center of the crystal and the source point is 9.7 m. This distance was set to be as short as possible for a high
and a large acceptance angle on the bent crystal. At 9.7 m from the source the largest horizontal acceptance angle is 5 mrad.Fig. 3 shows the end-station of the TRXAS beamline. The end-station is on the 2θ arm which can be rotated to satisfy the Bragg condition. As the focusing position along the arm can be varied, the end-station can also be translated such that the sample is always at the focusing position. The shortest crystal-to-focus distance available for the current set-up is about 0.6 m. The end-station is kept under a rough vacuum level of 2 × 10−2 torr and each section is separated by circular Kapton windows of outer diameter 15 mm and thickness 7.5 µm. Technically, the Kapton window can be replaced with a polypropylene window if higher at the sample position is required.
A PSD generally consists of a multi-element ). The PSD at the TRXAS beamline is a commercially available NMOS linear image sensor model S3904-1024N from the Hamamatsu Company. The contains 1024 elements each with an n-type formed on a p-type silicon substrate as a p–n junction and an active area of 20 µm × 2.5 mm. This detector uses a charge integration method to collect a signal. The generated electrical charges are temporarily stored in the junction capacitance of each photodiode and subsequently read out through the video line. After the detector is initiated by a start-pulse input, the signals are read out from each photodiode in sequence. The fastest readout frequency of the S3904-1024 model is 50 kHz. Thus, with 1024 photodiodes, the minimum time for the signal to be read out is 24 µs × 1024 = 24.58 ms. Hence, the fastest detection speed for this model is set to be 25 ms. The advantage of this data collection procedure is that the intensity of the signal output depends on the integration time which can be increased for low-light-level detection. However, as the charge-storage capacity is limited, the signal output will not increase if the intensity of the light is higher than the saturation level of the detector. The maximum storage charge capacitance for this model is 25 pC.
which converts incoming electromagnetic radiation into a recordable signal such as a current or a voltage using the photoelectric effect (Tassell & Maule, 19794. Commissioning results and performance test
4.1. Beamline commissioning
The radius of curvature for the Si(111) bent crystal can be estimated experimentally. As the p value is fixed at 9.7 m, the q value for a given θ was determined from the measured position of the focal spot. Thus the radius of curvature can be calculated using equation (1). For the set-up for Ti K-edge measurements, as an example, the maximum bending radius is 3.2 m with the corresponding crystal-to-focus distance and of 68.5 cm and 23.32°, respectively.
Fig. 4 demonstrates the useful photon energy range of the beamline. It covers photon energy for measuring a K-edge XANES spectrum from sulfur to iron. The XANES spectra in the figure were taken from S8 powder and a 5 µm-thick Fe foil. A thin layer of S8 powder was spread on a Kapton tape for the XANES measurement. In the set-up for measuring the S K-edge XANES spectrum the focal point of the photon beam is about 155 cm from the crystal. To avoid the loss of in this low-energy region the sample was measured under a 2 × 10−2 torr vacuum. The energy bandwidth ΔE for the S K-edge measurement is only about 20 eV. It is noted that an illuminated length on the bent crystal decreases with photon energy at fixed acceptance angle of the beamline which is limited by the 5 mrad opening angle of the mask in the front-end. A wider energy bandwidth for light-element measurements can be obtained when a smaller radius of curvature is used. There is a limitation to measuring K-edge XANES spectra of heavy elements with this beamline because the from the light source reduces very rapidly at photon energies above the of the storage ring. However, Fe K-edge XANES spectra can still be measured using this beamline. The XANES spectrum for Fe foil, shown in Fig. 4, was measured in air.
The performance of the TRXAS end-station for time-resolved measurements was tested by measuring the Ti K-edge XANES spectra of a 5 µm-thick Ti foil (Fig. 5). An XANES spectrum has been successfully recorded using a data-acquisition speed of 25 ms. However, as can be seen in Fig. 5, the spectrum shows a poor signal-to-noise (S/N) ratio. The S/N ratio can be improved by increasing the integration time. It was found that spectra with a good S/N ratio could be obtained when the integration time is 200 ms or longer, as shown in Fig. 5. Typical exposure times are between 500 ms and a few seconds. The exposure time required to saturate the detector was estimated from the measured readout voltage of the detector. It was found that, at 100 mA of a stored electron beam, the exposure times required to saturate the detector were about 2.6 s and 44 s at photon energy ranges around 2.7 keV and 7.1 keV, respectively.
Increasing the number of readouts to average is another way to improve the S/N ratio. Fig. 6 shows Ti K-edge XANES spectra measured using a constant total data-acquisition time of 1000 ms with different combinations of integration time and number of readouts. It can be seen from the figure that the quality of the spectra is similar for every combination. This suggests that the reduction of noise by averaging is also useful for XANES measurement using an NMOS linear image sensor.
4.2. In situ XANES measurement of TiO2 phase transformation
TiO2 is a useful material for many applications. It is commonly used as a white pigment in paint, plastic and paper. Because of the high reflective index, the compound is useful as an anti-reflection coating in silicon solar cells and in many thin-film optical devices (Macleod, 1986). Moreover, the compound was successfully utilized as a material for a gas sensor (Dutta et al., 1999). TiO2 has extensively been investigated and its XANES spectra are well characterized (Ruiz-López & Muñoz-Páez, 1991; Farges et al., 1997; Chen et al., 1997). Thus TiO2 was chosen for testing the performance of the beamline.
There are three main polymorphs of TiO2 found in nature; namely, anatase (tetragonal), brookite (orthorhombic) and rutile (tetragonal) which is the most stable phase of TiO2, although only the anatase and the rutile phases are used in most applications. It is known that the optical and electrical properties of the anatase and the rutile phases are different. Thus, it is possible to engineer optical or electrical properties of this compound by controlling the ratio between the two phases. In this work, TiO2 powder was prepared by the sol–gel method (Niltharach et al., 2012). The in situ XANES measurement under a condition was performed to monitor the formation of anatase TiO2.
4.2.1. In situ cell design
Varieties of in situ cells for even flow through or batch processes have been used for time-resolved experiments in different synchrotron radiation facilities. Some common components for these cells are heaters for the sample heating and X-ray windows made from Be, Al or Kapton foils for keeping the atmosphere inside the cell. In this work an in situ cell was developed in-house for experiments which require a thermal treatment during the measurements. The design of the cell is illustrated in Fig. 7. The dimension of the cell is 40 mm × 38 mm × 60 mm and it is made from stainless steel. A sample is put in the center of a 4 mm-diameter hole which is drilled through the cell. The cell is designed to accept the beam with a typical beam size used of 1 mm horizontally and 2 mm vertically. To maintain the inside atmosphere, two mica windows are placed at either side of the hole. Six cartridge heaters of outer diameter 6.35 mm and length 50.8 mm with K-type thermocouples are used for sample heating. The temperature of the sample is controlled by a Eurotherm 2216e temperature controller with an in-house-developed software. The in situ cell can be operated in the temperature range between room temperature and 723 K. Further development is required to increase the maximum temperature of the cell. The cell is installed on a three-axis linear translation stage which allows a precise alignment of the cell.
4.2.2. TiO2 preparation
The TiO2 powder was prepared using the sol–gel method (Niltharach et al., 2012). A mixture of 0.01 mol of titanium(IV) isopropoxide (Aldrich, Technical grade), 0.26 mol of 2-propanol (Qrëc, 99.7%) and 0.07 mol of ethylene glycol (Fluka, 98.0%) was stirred at room temperature for 15 min to obtain a homogeneous solution. After that, 0.04 mol of distilled water was added to the mixture and the solution was stirred until it was clear. The solution was then aged in an oven at 348 K for 24 h such that it became a gel. The gel was subsequently dried at 383 K and calcined at 473 K using a heating rate of 1.7 K min−1. The was performed in a 70%-N2/30%-O2 gas mixture with a total flow rate of 100 cm3 min−1 for 4 h to eliminate some of the organic compounds introduced by the sol–gel process. The obtained powder is mainly TiO2. A mixed phase of anatase and rutile phase is expected when the compound is calcined at higher temperatures. The powder was pressed into a pellet 4 mm in diameter and less than 1 mm in thickness for the measurement.
4.2.3. In situ XANES measurement
XANES spectra of TiO2 have been extensively studied (Ruiz-López & Muñoz-Páez, 1991; Farges et al., 1997; Chen et al., 1997) and the amorphous to anatase transformation for TiO2 occurs within the operating temperatures of our in-house-developed in-situ cell, thus the phase transformation was chosen to test the capability to perform an in situ measurement at the TRXAS beamline. The prepared sample was put into the in situ cell and heated using a heating rate of 2 K min−1 from room temperature to 723 K. The was performed in a 70%-N2/30%-O2 gas mixture with a total flow rate of 100 cm3 min−1. Ti K-edge XANES spectra were recorded at room temperature and then every 50 K between 323 K and 573 K. From 573 K to 723 K where the phase transformation is expected, the spectra were recorded in 10 K intervals. The same temperature points during cooling were also measured. The integration time was chosen to be 200 ms and each spectrum was an average of ten readouts.
Fig. 8 shows normalized Ti K-edge XANES spectra of a sol–gel TiO2 sample demonstrating a caused by the temperature change. XANES spectra of the standard anatase and rutile TiO2 were also taken and are shown in the figure for comparison. The XANES spectra of the anatase and rutile phases have been qualitative identified (Ruiz-López & Muñoz-Páez, 1991; Farges et al., 1997; Chen et al., 1997). The origin of the pre-edge peaks (A1–A3), a characteristic shoulder (B) and main-edge peaks (C1–C3) was described by Farges et al. (1997). As seen from the standard anatase and rutile spectra, both spectra show three pre-peaks (A1–A3) in the energy range from 4965 to 4975 eV which correspond to the 1s → 3d transitions. The A1 peak is attributed mainly to the quadrupole transitions to the t2g levels in the TiO6 octahedron while the A2 and the A3 peaks are attributed to the 1s to 3d dipole transitions and are designated as 1s → t2g and 1s → eg transitions in an octahedral field, respectively. The shoulder B is a signature of an edge-sharing structure of TiO6 units. The main peaks (C1–C3) are related to transitions of excited core or valence electrons. The C1 and C2 peaks involve the non-bonding O 2p → Ti 3d transition while the C3 peak represents the transition from the bonding and anti-bonding O 2p orbitals. As the symmetry of the anatase and rutile phases are different (Ruiz-López & Muñoz-Páez, 1991), the relative intensities between the C1, C2 and C3 peaks could be used to identify the phases. From Fig. 8 the amorphous to anatase transformation occurs at a temperature between 623 K and 673 K. It is noted that this experiment was carried out when the data acquisition software was not fully developed; some operations were done manually. This prevented us from obtaining the expected ultimate time resolution for this experiment, which is 2 s. Thus, a low heating rate of 2 K min−1 in the process was used to monitor the transition from amorphous to anatase. The inset of Fig. 8 shows that it is possible to observe the gradual changes of the pre-edge peaks when the temperature was varied from 633 K to 663 K with a 10 K interval, indicating the phase transformation from amorphous to anatase.
From the XANES spectra of the sol–gel sample at selected temperatures shown in Fig. 8, the A1 peak and the shoulder B are not clearly observed which could be due to the distortion from an ideal TiO6, a partial amorphous phase at low temperatures (Purans et al., 2001) or incomplete TiO2 composition as there could still be residual organic precursors from the sol–gel process. When the temperature was raised to 673 K, the measured XANES spectrum showed all the features corresponding to the crystalline anatase phase. These features remain stable when the temperature was further increased to 723 K or holding at 723 K for 60 min which suggests that the structure of TiO2 becomes anatase when it is calcined at 673 K and the anatase phase remains up to 723 K. The C2 peak, characteristic of the rutile phase, was not clearly observed in any of the spectra. This indicates that a complete anatase to rutile phase transformation requires a higher temperature. A mixed anatase and rutile phase has been observed at 823 K with an anatase to rutile ratio of 79:21 (Niltharach et al., 2012). Fig. 9 shows the normalized Ti K-edge XANES spectra measured during cooling showing no significant change from the spectrum measured at 723 K which suggests that the acquired phase is stable.
5. Conclusions
A time-resolved K-edge XANES spectra was demonstrated. An in-house in situ cell has been developed and tested at the TRXAS beamline to observe the change in the XANES spectra during thermal treatment. Thermal treatment in the production of TiO2 by the sol–gel method was selected as an in situ example experiment. The XANES spectra measured during the heating process show a clear formation of the anatase structure. The complete anatase to rutile phase transformation was not observed at 723 K.
beamline has been successfully constructed at the SLRI. By using an energy-dispersive scheme, with a 1024-element NMOS linear image sensor, a shortest data acquisition time of 25 ms for TiAcknowledgements
The authors would like to thank S. Duangnil, D. Bamroongkoh, A. Tong-orn and the Technical and Engineering Division staff for their technical assistance. WS and SC would like to acknowledge the SLRI for financial support.
References
Blank, H., Neff, B., Steil, St. & Hormes, J. (1992). Rev. Sci. Instrum. 63, 1334–1337. CrossRef CAS Web of Science Google Scholar
Bunker, G. (2010). Introduction to XAFS: A Practical Guide to X-ray Absorption Fine Structure Spectroscopy. New York: Cambridge University Press. Google Scholar
Caliebe, W. A., So, I., Lenhard, A. & Siddons, D. P. (2006). Radiat. Phys. Chem. 75, 1962–1965. Web of Science CrossRef CAS Google Scholar
Cezar, J. C., Souza-Neto, N. M., Piamonteze, C., Tamura, E., Garcia, F., Carvalho, E. J., Neueschwander, R. T., Ramos, A. Y., Tolentino, H. C. N., Caneiro, A., Massa, N. E., Martinez-Lope, M. J., Alonso, J. A. & Itié, J.-P. (2010). J. Synchrotron Rad. 17, 93–102. Web of Science CrossRef CAS IUCr Journals Google Scholar
Chen, J., Zhang, H., Tomov, I. V., Ding, X. & Rentzepis, P. M. (2007). Chem. Phys. Lett. 437, 50–55. Web of Science CrossRef CAS Google Scholar
Chen, L. X., Lee, P. L., Gosztola, D. J., Svec, W. A. & Wasielewski, M. R. (1999). J. Synchrotron Rad. 6, 403–405. Web of Science CrossRef CAS IUCr Journals Google Scholar
Chen, L. X., Rajh, T., Wang, Z. & Thurnauer, M. C. (1997). J. Phys. Chem. B, 101, 10688–10697. CrossRef CAS Web of Science Google Scholar
Couves, J. W., Thomas, J. M., Catlow, C. R. A., Greaves, G. N., Baker, G. & Dent, A. J. (1990). J. Phys. Chem. 94, 6517–6519. CrossRef CAS Web of Science Google Scholar
Dartyge, E., Depautex, C., Dubuisson, J. M., Fontaine, A., Jucha, A., Leboucher, P. & Tourillon, G. (1986). Nucl. Instrum. Methods Phys. Res. A, 246, 452–460. CrossRef Web of Science Google Scholar
Dutta, P. K., Ginwalla, A., Hogg, B., Patton, B. R., Chwieroth, B., Liang, Z., Gouma, P., Mills, M. & Akbar, S. (1999). J. Phys. Chem. B, 103, 4412–4422. Web of Science CrossRef CAS Google Scholar
Farges, F., Brown, G. E. & Rehr, J. J. (1997). Phys. Rev. B, 56, 1809–1819. CrossRef CAS Web of Science Google Scholar
Flank, A. M., Fontaine, A., Jucha, A., Lemonnier, M., Raoux, D. & Williams, C. (1983). Nucl. Instrum. Methods Phys. Res. 208, 651–654. CrossRef CAS Web of Science Google Scholar
Fontaine, A., Dartyge, E., Jucha, A. & Tourillon, G. (1987). Nucl. Instrum. Methods Phys. Res. A, 253, 519–522. CrossRef Web of Science Google Scholar
Hedman, B. & Pianetta, P. (2007). AIP Conf. Proc., 882, 1–937. Google Scholar
Koningsberger, D. C. & Prins, R. (1988). Editors. Principles, Applications, Techniques of EXAFS, SEXAFS and XANES. Chemical Analysis: A Series of Monographs on Analytical Chemistry and its Applications, Vol. 92. Toronto: Wiley-Interscience. Google Scholar
Lützenkirchen-Hecht, D., Grundmann, S. & Frahm, R. (2001). J. Synchrotron Rad. 8, 6–9. Web of Science CrossRef IUCr Journals Google Scholar
Macleod, H. A. (1986). Thin Film Optical Filters, p. 370. New York: MacMillan. Google Scholar
Meneses, C. T., Flores, W. H., Sotero, A. P., Tamura, E., Garcia, F. & Sasaki, J. M. (2006). J. Synchrotron Rad. 13, 468–470. Web of Science CrossRef CAS IUCr Journals Google Scholar
Niltharach, A., Kityakarn, S., Worayingyong, A., T-Thienprasert, J., Klysubun, W., Songsiriritthigul, P. & Limpijumnong, S. (2012). Physica B, 407, 2915–2918. Web of Science CrossRef CAS Google Scholar
Pascarelli, S., Neisius, T., De Panfilis, S., Bonfim, M., Pizzini, S., Mackay, K., David, S., Fontaine, A., San Miguel, A., Itié, J. P., Gauthier, M. & Polian, A. (1999). J. Synchrotron Rad. 6, 146–148. Web of Science CrossRef IUCr Journals Google Scholar
Purans, J., Azens, A. & Granqvist, C. G. (2001). Electrochim. Acta, 46, 2055–2058. Web of Science CrossRef CAS Google Scholar
Ruiz-López, M. F. & Muñoz-Páez, A. (1991). J. Phys. Condens. Matter, 3, 8981–8990. Google Scholar
Tassell, C. & Maule, D. J. (1979). Microelectron. J. 10, 35–44. CrossRef Google Scholar
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.