A multipurpose six-axis κ-diffractometer, together with the of the ESRF light source and a CCD area detector, has been explored for studying epitaxial relations and crystallinity in thin film systems. The geometrical flexibility of the six-axis goniometer allows measurement of a large volume in providing an in-depth understanding of sample crystal relationships. By a set of examples of LaAlO3 thin films deposited by the atomic layer deposition technique, the possibilities of the set-up are presented. A fast panoramic scan provides determination of the crystal orientation matrices, prior to more thorough inspection of single Bragg nodes. Such information, in addition to a broadening analysis of families of single reflections, is shown to correlate well with the crystallinity, crystallite size, strain and epitaxial relationships in the thin films. The proposed set-up offers fast and easy sample mounting and alignment, along with crucial information on key features of the thin film structures.
1. Introduction
Thin solid films are playing an increasingly larger part in emerging materials technology by providing the possibility to design materials for a wide range of applications including solar cells (Britt & Ferekides, 1993; Contreras et al., 1999; Ito et al., 2008; Shah et al., 1999), hydrogen storage (Ito et al., 2008; Vermeulen et al., 2006), solid oxide fuel cells (de Souza et al., 1997; Will et al., 2000) and battery technology (Bates et al., 2000; Brousse et al., 1998). Understanding the structure of the thin film, including the interfacial relationship between the substrate and deposited layer, is in this respect of crucial importance. As such films become thinner, the traditional θ–2θ Bragg–Brentano home laboratory approach becomes ineffective owing to low diffracted and poor signal-to-noise ratio. Relatively fast mapping over large q-volumes is imperative for a range of studies, including crystallization dynamics, phase transitions and peak family evaluation. Thus, a flexible geometrical set-up with minimum constraints on space and with an angular movement control that allows studies of thickness variations down towards the single-digit nanometre range would be a very valuable complementary asset to established thin film diffraction set-ups.
Here, we show how this goal can be reached with the means of a multipurpose κ-diffractometer equipped with a CCD area detector. A similar approach has previously been applied using a Nonius Kappa CCD diffractometer to illustrate thin film disorientation (Aubert et al., 2006). Another related approach has previously been used at the Swiss–Norwegian Beam Lines (SNBL) to study Bragg scattering in a polar Nd-doped BiFeO3 thin film on a MgO substrate and diffuse scattering on the domain structure in PbTiO3 films (Leontyev et al., 2011; Mo et al., 2008). A description of the set-up and experimental strategies are provided and the approach is illustrated with 5–100 nm thin films based on Co3O4 (Klepper et al., 2007), MnO2 (Foss et al., 2005) and LaAlO3 (Sønsteby et al., 2012) deposited by the atomic layer deposition (ALD) technique (Suntola & Antson, 1976).
2. Experimental
The versatile κ-goniometry1 is widely applied for single-crystal diffraction studies and can be readily adopted for thin film samples. The basic mathematics for the κ-goniometer geometry used has been thoroughly described (Paciorek et al., 1999). Currently, the KUMA6 κ-diffractometer at the BM01A line of the SNBL at the European Synchrotron Radiation Facility is used. The diffractometer operates under control of the CrysAlis software (Oxford Diffraction, 2006) that performs angular calculations based of the method reported by Thorkildsen et al. (2006). The experimental set-up and software, albeit not optimized for a thin film experiment, possess the necessary flexibility together with an intuitively clear user interface that offers a wide range of geometries for collecting data. The Crysalis software was further used for indexing reflections and inspection of reciprocal space.
The monochromatic beam was prepared by the optic system comprising two focusing mirrors and a focusing monochromator. The beam size was routinely set to ∼0.5 mm × 0.5 mm and the wavelength to around 0.7 Å. The beam is polarized in the horizontal plane (96%); calibration of the wavelength was performed using a LaB6 NIST 660 standard powder sample and the calibration of the diffractometer was based on measurements of a ruby single-crystal.
2.1. Sample mounting and alignment
Thin films for research purposes are typically deposited on a sample substrate of a material of choice, often covering an area in the range of a few cm2. For practical purposes the substrate is oriented horizontally, i.e. with the surface normal in the vertical direction for subsequent routine experiments. The sample substrate is mounted on a goniometer head with arcs, so that the thin film plane is almost parallel to the incoming beam. The samples are pre-aligned using an optical microscope and subsequently aligned with the aid of a complementary alignment laser by adjusting the tilts of the goniometer head. Having aligned the sample horizontally, the sample is positioned into the beam by a vertical displacement guided by an optical microscope or by an additional detector set in transmission mode (so called `X-ray eye').
2.2. Panoramic scan
Orientations matrices and mutual orientations of the substrate and film unit cells are first obtained by mapping a large volume of φ-scan for a set of ω-angles. The detector is placed close to the sample, in order to maximize the q-range per frame. Such a data collection results in two sets of reflections assuming both film and substrate are single crystals, one coming from the thin film and the other from the substrate.
with a traditionalThere are some pitfalls to be aware of, namely a systematic distortion of the shape for Bragg reflections that is convoluted with the footprint of the beam, and also a small dead zone near the rotational axis. The first problem is minimized by appropriate selection of the initial tilt angle and beam size. To recover reflections positioned near the rotation axis, additional data collection with non-zero κ and ω angles has to be performed.
For the described broad scans with the thin film surface almost parallel to the beam, an important volume in the ω-scan for the film positioned horizontally. Similar to the scan described above, the detector is set at the closest distance in order to provide the best coverage of the reciprocal space.
around the normal axis is unavailable. In addition, scattering in the horizontal plane is not measured optimally due to Lorentz and polarization factors. The missed volume is easily recovered by anThese panoramic scans provide complete information on the scattering intensity for a large volume of the
and allow for derivation of the orientational relationships between the film and the substrate, characterization of strain in the film, observation of diffuse scattering and its orientational distributions.2.3. Single-peak mapping
The panoramic screening may reveal features for single reflections that call for higher resolution mapping. Based on the orientation matrix, the Bragg node of interest can be brought into reflecting position in the vertical plane. An ω-scan with a small angular step (typically 0.01–0.02°) and the detector at maximum distance provides the necessary volume information. One should keep in mind the variation of the footprint of the beam with the incident angle, and corrections may be required for the diffraction intensities. However, the variation is expectedly small if just a small angular range is scanned, and can be neglected for a scan that just maps a single Bragg node and its close neighbourhood.
3. Results
Selected illustrative experiments are described in the following section.
3.1. Scattering from the substrate
Some considerations on the use of substrates are pertinent. Since the algorithm for determining the orientation matrix includes indexing of a large number of reflections from both the substrates and the thin film, it is imperative that the substrate gives well defined Bragg scattering. Thin film diffraction is often less defined due to crystal truncation (Robinson, 1986), surface roughness (Sinha et al., 1988) and structural or chemical defects (Bahr et al., 1995). Thus, by knowing that the substrate in the sample system has well defined scattering, the analysis of the collected diffraction data can routinely be attributed to the correct component of the sample.
For historical (and partly practical) reasons, the most common substrate for deposition of thin films is silicon, typically Si (100) wafers. However, strong thermal diffuse scattering from phonons of the silicon crystal results in high background that contaminates the scattering from the film (Fig. 1a). This phenomenon makes the study of crystalline thin films deposited on silicon difficult using the current set-up. A similiar result is seen for soda-lime glass (Fig. 1b).
Typical substrates of choice during the current model experiments were single crystals of magnesium oxide (MgO), aluminium oxide (Al2O3), lanthanum aluminate (LaAlO3) and strontium titanate (SrTiO3; Fig. 1c). Single-crystal substrates of these compounds show very well defined scattering, which makes it easy to determine the crystallographic relationships to the deposited thin film.
3.2. Panoramic scans
Panoramic data collection is a means for determining the orientation matrix of the system, either for the actual thin film, the substrate itself or both. Most frequently one is interested in determining the relative orientation of the thin film to the substrate. Using the CrysAlis software, the reciprocal lattices of the two separate parts of the system can be readily superimposed, providing an understandable visualization of the system at hand. In addition, the panoramic data collection can be used to reconstruct planes in Even though there are some blind areas due to instrumental restrictions, most planes can be inspected [Fig. 2: here the specular reflection is in a dead zone covering the (h00) reflections].
3.3. Single-peak mapping
The shape and size of single reflections give crucial insight into crystalline properties, i.e. size, strain and chemical and structural defects.
An example of the mapping of single reflections is shown in Fig. 3. Here, (100) from both the SrTiO3 substrate and a 7 nm thin film of LaAlO3 is shown for two different samples (Fig. 3). The substrate used in Fig. 3(a) is etched with hydrofluoric acid creating a TiO2-terminated surface prior to LaAlO3 deposition. For Fig. 3(b), the substrate was not pre-treated and thus has a random surface termination. An azimuthal integration in 2θ reveals a similar peak intensity and shape for the two samples, pointing out how this would be difficult to quantize using home laboratory equipment. Since the atomic termination of the substrate may influence epitaxial relationships and crystallinity, the possibility to gain insight into such aspects by means of the described measurements becomes crucial.
Another example is shown for the LaAlO3||LaAlO3 system, apparently homoepitaxial as shown by home laboratory X-ray diffraction (XRD) and X-ray reflectivity (XRR). When looking at a family of reflections for analysis, a very distinct splitting of the asymmetric (nn0) reflections was observed for high-q reflections (Fig. 4). The splitting corresponds to a lattice parameter shift of less than +0.01 Å for the thin film compared with the substrate. This may possibly be related to the chemical composition, which would be important knowledge for further use of the material. The effect is too small to be observed on home laboratory equipment, owing to the large substrate-to-thin-film signal ratio and because the effect is only outspoken for high-q reflections.
As shown for the LaAlO3 thin film systems, the possibility to map single reflections using this simple geometry provides possibilities for studying subtle effects in thin film systems. These can be broadening effects, diffuse scattering around Bragg peaks or peak splitting, all being important effects that reveal interesting information about the sample.
4. Conclusions
The single-crystal six-axis κ-diffractometer KUMA6 (BM01A, SNBL at ESRF) has several advantages for retrieving structural information for thin film systems. The few geometrical constraints make it possible to perform a range of studies both in situ and ex situ. Fast inspection of relatively large volumes in the with very detailed maps of selected Bragg nodes is one option. For powder and polycrystalline thin films, the set-up provides, for example, means to describe and identification of diffuse scattering from the substrates.
Through a set of examples, it has been shown how the proposed instrumentation can be used to gain insight into the structure and crystallinity of thin films. The panoramic scan is used to determine the orientation matrix of the sample, as for the LaAlO3||SrTiO3 system. Furthermore, single Bragg nodes can be studied in detail by increasing the sample-to-detector distance. This has been demonstrated for the LaAlO3||LaAlO3 sample, where a double peak could be identified. In total, the proposed instrumentation can be used to study crystallinity, crystallite size, strain and epitaxial relationships in a thin film sample with fast sample mounting, fast data collection and easy data analysis.
Further development of the set-up is achieved via implementation of a fast pixel area detector, Dectris PILATUS2M. Low background, the possibility to suppress fluorescence and fast readout time being augmented with flexible κ goniometry will allow probing of the kinetic processes evolving in a thin film as a function of external fields, and in total provide a very versatile technique for structural characterization of crystalline thin films.
Footnotes
1The kappa instrumentation was invented by Siem Poot of Enraf–Nonius, and protected worldwide by patents (Poot, 1972).
Acknowledgements
The authors would like to thank Karina B. Klepper for providing some of the samples. We acknowledge the SNBL staff for their great support during the experiments at ESRF.
References
Aubert, E., Wenger, E., Link, M., Assouar, B., Didierjean, C. & Lecomte, C. (2006). J. Appl. Cryst. 39, 919–921. Web of Science CrossRef CAS IUCr Journals Google Scholar
Bahr, D., Press, W., Jebasinski, R. & Mantl, S. (1995). Phys. Rev. B, 51, 12223–12227. CrossRef CAS Web of Science Google Scholar
Bates, J. B., Dudney, N. J., Neudecker, B., Ueda, A. & Evans, C. D. (2000). Solid State Ion. 135, 33–45. Web of Science CrossRef CAS Google Scholar
Britt, J. & Ferekides, C. (1993). Appl. Phys. Lett. 62, 2851. CrossRef Web of Science Google Scholar
Brousse, T., Retoux, R., Herterich, U. & Schleich, D. M. (1998). J. Electrochem. Soc. 145, 1–4. Web of Science CrossRef CAS Google Scholar
Contreras, M. A., Egaas, B., Ramanathan, K., Hiltner, J., Swartzlander, A., Hasoon, F. & Noufi, R. (1999). Prog. Photovolt. 7, 311–316. CrossRef CAS Google Scholar
Foss, S., Nilsen, O., Olsen, A. & Taftø, J. (2005). Philos. Mag. 85, 2689–2705. CAS Google Scholar
Ito, S., Murakami, T. N., Comte, P., Liska, P., Grätzel, C., Nazeeruddin, M. K. & Grätzel, M. (2008). Thin Solid Films, 516, 4613–4619. Web of Science CrossRef CAS Google Scholar
Klepper, K., Nilsen, O. & Fjellvåg, H. (2007). J. Cryst. Growth, 307, 457–465. Web of Science CrossRef CAS Google Scholar
Leontyev, I. N., Yuzyuk, Y. I., Janolin, P. E., El-Marssi, M., Chernyshov, D., Dmitriev, V., Golovko, Y. I., Mukhortov, V. M. & Dkhil, B. (2011). J. Phys. Condens. Matter, 23, 332201. Web of Science CrossRef PubMed Google Scholar
Mo, F., Chernyshov, D., Thoresen, L. S., Breiby, D. W. & Tybell, T. (2008). Acta Cryst. A64, C520–C521. CrossRef IUCr Journals Google Scholar
Oxford Diffraction (2006). CrysAlis CCD. Oxford Diffraction Ltd, Abingdon, Oxfordshire, England. Google Scholar
Paciorek, W. A., Meyer, M. & Chapuis, G. (1999). Acta Cryst. A55, 543–557. Web of Science CrossRef CAS IUCr Journals Google Scholar
Poot, S. (1972). US Patent 3 636 347. Google Scholar
Robinson, I. (1986). Phys. Rev. B, 33, 3830–3836. CrossRef CAS Web of Science Google Scholar
Shah, A., Torres, P., Tscharner, R., Wyrsch, N. & Keppner, H. (1999). Science, 285, 692–698. Web of Science CrossRef PubMed CAS Google Scholar
Sinha, S. K., Sirota, E. B., Garoff, S. & Stanley, H. B. (1988). Phys. Rev. B, 38, 2297–2311. CrossRef Web of Science Google Scholar
Sønsteby, H., Østreng, E., Nilsen, O. & Fjellvåg, H. (2012). ALD/BALD2012 – 12th International Conference on Atomic Layer Deposition, Dresden, Germany. Google Scholar
Souza, S. de, Visco, S. J. & De Jonghe, L. C. (1997). J. Electrochem. Soc. 144, L35–L37. Google Scholar
Suntola, T. & Antson, J. (1976). Instrumentarium Oy, Finland. DE2553048A1. Google Scholar
Thorkildsen, G., Larsen, H. B. & Beukes, J. A. (2006). J. Appl. Cryst. 39, 151–157. Web of Science CrossRef CAS IUCr Journals Google Scholar
Vermeulen, P., Niessen, R. & Notten, P. (2006). Electrochem. Commun. 8, 27–32. Web of Science CrossRef CAS Google Scholar
Will, J., Mitterdorfer, A., Kleinlogel, C., Perednis, D. & Gauckler, L. J. (2000). Solid State Ion. 131, 79–96. Web of Science CrossRef CAS Google Scholar
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.