research papers
Momentum-resolved resonant inelastic X-ray scattering on a single crystal under high pressure
aDepartment of Physics, Tohoku University, Sendai 980-8578, Japan, bSPring-8, Japan Atomic Energy Agency, Sayo, Hyogo 679-5148, Japan, cDepartment of Physics, Okayama University, Okayama 700-8530, Japan, dDepartment of Applied Physics, Tohoku University, Sendai 980-8579, Japan, eDepartment of Physics, Hokkaido University, Sapporo 060-0810, Japan, fNational Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan, and gSchool of Science and Technology, Kwansei Gakuin University, Sanda, Hyogo 669-1337, Japan
*Correspondence e-mail: yoshimasa@kwansei.ac.jp
A single-crystal momentum-resolved resonant inelastic X-ray scattering (RIXS) experiment under high pressure using an originally designed diamond anvil cell (DAC) is reported. The diamond-in/diamond-out geometry was adopted with both the incident and scattered beams passing through a 1 mm-thick diamond. This enabled us to cover wide momentum space keeping the scattering angle condition near 90°. Elastic and 2.5Ca11.5Cu24O41 at the Cu K-edge was thus successful. Though the inelastic intensity becomes weaker by two orders than the ambient pressure, RIXS spectra both at the center and the edge of the were obtained at 3 GPa and low-energy electronic excitations of the cuprate were found to change with pressure.
from the diamond was drastically reduced using a pinhole placed after the DAC. Measurement of the momentum-resolved RIXS spectra of SrKeywords: resonant inelastic X-ray scattering; electronic excitations; high pressure; diamond anvil cell.
1. Introduction
Resonant inelastic X-ray scattering (RIXS) stands out as a powerful element- and orbital-specific probe of the electronic excitations between the occupied and unoccupied valence-band states (Ament et al., 2011), which has been rapidly developed by utilizing third-generation radiation X-rays. Since then, RIXS has achieved significant progress in condensed matter physics. It is sensitive to local (e.g. crystal-field) (Ishii et al., 2011), nearest-neighboring (e.g. charge transfer) (Kao et al., 1996; Hasan et al., 2000; Kim et al., 2010) and collective (e.g. magnons) interactions (Hill et al., 2008), making it a comprehensive tool for the electron–electron interactions. When using a single-crystal sample, RIXS studies can be performed in a momentum-resolved manner. This is the most important advantage of RIXS when compared with other optical methods.
Another advantage of RIXS, particularly in the hard X-ray regime, is the large penetration length of photons. It not only ensures the bulk sensitivity of the observed spectra but also naturally leads us to extend the RIXS technique to measurement under extreme environments because the study of physical properties of materials under extreme environments is of central importance in condensed matter physics. In particular, pressure is one of the most important external parameters as it is a clean and efficient way to directly alter the interatomic distance, hence the
and the band width, which in turn affect drastically the physical properties. Therefore, experimental techniques for studying valence electronic states through the observation of low-energy excitations under high pressure are in high demand. Momentum resolution is further required for detailed studies of the electronic band structure of crystalline materials. In this respect RIXS perfectly matches the requirements, and a diamond anvil cell (DAC), which is commonly used as a device for generating high pressure, is suitable for this purpose.Shukla et al. (2003) and Rueff & Shukla (2010) have performed pioneering high-pressure RIXS experiments using a DAC and observed excitations of valence electrons in NiO and CoO. However, they measured polycrystalline samples, so that the advantage of momentum resolution was not exploited completely. To the best of our knowledge, momentum-resolved RIXS studies under high pressure have not yet been reported on single crystals. On the other hand, several works of non-resonant inelastic X-ray scattering (NIXS) using DACs have been performed to measure phonons under high pressure (Raymond et al., 2002, 2011; Farber et al., 2006; Loa et al., 2007). A common experimental difficulty of NIXS and RIXS experiments using single crystals under high pressure is disentanglement of the signal arising from the sample and the parasitic signal from the high-pressure gasket or the diamond around the sample. The parasitic signal might be larger in RIXS because the photon energy of RIXS (∼9 keV in the present study) is much lower than that of non-resonant which is typically above 20 keV and hence reduces incident photon intensity on the sample. Furthermore, the lower photon energy imposes additional constraints on the experimental geometry. For example, transmission geometry is almost impossible in RIXS. When one keeps the scattering angle close to 90° to minimize the the geometrical restriction is further severe.
Here we overcome these difficulties and report the first demonstration of the momentum-resolved RIXS to a single crystal under high pressure. To this end we have used a DAC specially designed to accommodate the RIXS geometry requirements while avoiding the parasitic signal from the gasket, by enabling to work in the reflection geometry with both incoming and scattered X-rays passing through the same diamond. Focus of the incoming beam was achieved using Be refractive lenses and a pinhole was placed to suppress scattering from the diamond. The sample is a single crystal of the two-leg ladder cuprate, Sr14–xCaxCu24O41, a composite system in which Cu2O3 two-leg ladders and CuO2 chains coexist with a different periodicity and the two-leg ladder is responsible for the conductivity. This choice is motivated both by the relatively strong RIXS signal previously observed on this system at ambient pressure (∼15 counts s−1 for the Mott gap excitation) (Ishii et al., 2007), and by reports that its physical properties vary greatly with external and/or chemical pressure, that is, an insulator–metal transition takes place at about 6 GPa for x = 0 and superconductivity sets in at around 3 GPa for x ≥ 9 (Kojima et al., 2001). These two phenomena call for a study of the momentum dependence of the electronic structure of Sr14–xCaxCu24O41 as a function of pressure, which we show in this paper for x = 11.5.
2. Experimental set-up
2.1. Beamline optics
RIXS experiments were performed at BL11XU of SPring-8. Incident X-rays were monochromated by a double-crystal Si(111) monochromator and a secondary Si(400) channel-cut monochromator. The incident X-ray energy was tuned to 8993 eV where charge excitations are resonantly enhanced (Ishii et al., 2007). Scattered X-rays were analyzed in energy by a spherically bent diced Ge(733) crystal on a Rowland circle of 2 m in diameter. The total energy resolution estimated from the full width at half-maximum (FWHM) of the elastic peak was about 500 meV. While a horizontal focus of 45 µm is achieved for the incoming beam with a cylindrical mirror, for this experiment we have added compound refractive lenses made of berylium (Be lenses) after the Si(111) monochromator in order to focus the beam vertically (Snigirev et al., 1996; Protopopov & Valiev, 1998). The Be lenses consist of seven holes of diameter 2.2 mm drilled in a Be block. The focal length is about 18.9 m, very close to the distance between the lenses and the sample position, 19 m. The performance of the Be lenses was checked by measurement of the vertical focus at the sample position using the knife-edge method, shown in Fig. 1. The open and filled profiles show the result of the knife-edge scan without and with the Be lenses, respectively. The vertical FWHM is found to decrease by a factor of four, from 800 to 200 µm, when using the Be lenses, confirming their adequacy.
2.2. Sample environment
Scattering and spectroscopic high-pressure experiments are often performed in the in-plane geometry with both incoming and scattered X-rays going through a Be gasket, owing to the low X-ray absorption of Be and the wide optical access (Hemley et al., 1997). However, Be being a metal, its loss spectrum shows several excitations between 0 and a few eV, and is therefore unsuitable for RIXS experiments. Because diamond is transparent up to about 6 eV loss, we decided to use a diamond-in/diamond-out geometry. The sample was loaded in the DAC as shown in Fig. 2, which has two custom-designed features to be fully compatible with the geometrical requirements of a single-crystal RIXS experiment. One is a large horizontal opening angle on one side of the cell to access wide momentum space keeping the condition of scattering angles near 90°. The condition minimizes the intensity of the as the is parallel to the polarization of the incident photons. The opening angles of the cell used in the present study are about 100° and 30° in the horizontal and vertical, respectively, and enabling us to cover the entire of the ladder (ac) plane of Sr14–xCaxCu24O41. The other is asymmetric thickness of the diamonds, 1.0 and 1.5 mm. In this diamond-in/diamond-out geometry the absorption effect by the diamond cannot be ignored. To minimize the absorption of X-rays by the diamond, both the incident and scattered beams pass through the thinner diamond as shown in Fig. 2(b). The path length of X-rays in the diamond anvil is times as long as the thickness of the diamond under practical experimental conditions: the incident and outgoing angles are 45° and the scattering angle is 90°. In this configuration we gain a factor of four in intensity, which is estimated from the transmission ratio of the 1 mm diamond to the 1.5 mm diamond for the respective path length. Here we used the of diamond (about 10.6 cm−1 at 8980 eV; Sasaki, 1990). Pressure was evaluated by the ruby-fluorescence method (Piermarini et al., 1975). A 1:1 mixture of Fluorinert F70 and F77 was used as the pressure-transmitting medium. The culet diameter of the diamond was 1 mm. A gasket made of stainless steel SUS301 was used, with a sample chamber of diameter 500 µm.
Single crystals of Sr14–xCaxCu24O41 (x = 0, 11.5) were grown by the traveling-solvent floating-zone method. The polished surface of a piece 120 µm × 300 µm × 70 µm in size was placed on the culet of the 1.5 mm-thick diamond, mounted so that the bc plane is almost parallel to the and that the incident beam impinges on the surface of the ac plane.
We use the Q = (H, K, L). Because the momentum dependence along the b axis is expected to be very small, we selected the b* component of the momentum transfer where the scattering angle was close to 90°.
of a face-centered orthorhombic of the ladder part to denote absolute momentum transfer,4. A pinhole as a post-sample slit system
In Fig. 3(a) the RIXS spectrum measured on a single crystal of the parent compound Sr14Cu24O41 at 2 GPa (filled circles) is compared with the spectrum measured away from the sample (open circles), which we use as a background spectrum. The spectrum obtained on the sample in the DAC is clearly different from the RIXS spectra obtained on the same compound at ambient pressure (Ishii et al., 2007), as in the former the elastic peak is asymmetric with a strong tail on the energy-loss side, and the intensity is stronger in the 7–8 eV range. We ascribed these two differences to elastic and respectively, from the diamond. Indeed, the incident beam sees the diamond as a point source, and because it is ∼1 mm away from the sample the resulting deviates to the energy-loss side. Further, the spectrum of the diamond starts at about 6 eV, which is assigned to an excitation across the band gap of the diamond (Caliebe et al., 2000). In order to reduce the signal from the diamond, we introduced a pinhole (300 µm diameter) as a post-sample slit system (Hiraoka & Cai, 2010), placed as close as possible to the DAC. Its function, schematically represented in Fig. 4, is to act as a collimator that allows the signal of interest to be scattered from the sample and blocks the scattering from the diamond. The effect of the pinhole is illustrated by the RIXS spectra measured on Sr2.5Ca11.5Cu24O41 with the pinhole in Fig. 3(b). The elastic line is symmetric and the intensity around 8 eV disappears in the background spectrum (open) and becomes comparable with the ambient-pressure spectra given by Ishii et al. (2007), thus highlighting the importance of using the pinhole. One might suspect that this single pinhole cannot shield the scattering from the diamond perfectly. Actually, scattered photons produced inside the diamond can still reach the analyzer, as shown by the dotted line in Fig. 4. In order to shield them completely, one has to assemble two (sample and detector) slits. Alternatively, the scattering from the diamond can be efficiently reduced using the spatial discrimination of a two-dimensional detector, as proposed recently by Verbeni et al. (2009). However, as a matter of fact, such scattered photons from inside the diamond are negligible in the spectra in Fig. 3(b). This is because the scattering from the diamond is strongest on its surface. As the incident photons penetrate inside the diamond, the intensity of the scattered photon is reduced. Therefore we conclude that a single pinhole is sufficient to remove the parasitic signal from the diamond for the present study.
3. Results
We measured momentum-resolved RIXS spectra under high pressure by using a single crystal of Sr2.5Ca11.5Cu24O41. The value of the applied pressure was 3 GPa. Fig. 5(a) depicts the RIXS raw spectra obtained at two momenta, Q = (0, K, 0) and (0, K, 0.5), corresponding to the zone center and zone boundary along the leg direction, respectively. Despite the very low intensity we have succeeded in measuring high-pressure RIXS spectra with reasonable statistics. We also show the raw spectra at ambient pressure at the same momenta in Fig. 5(b). The intensities at the two pressures are substantially different from each other because the spectra at ambient pressure were measured without the DAC. For instance, the intensity of the 3 GPa spectrum becomes about 120 times weaker than that of the ambient-pressure spectrum at the zone center. This reduction of intensity is due to several factors such as the attenuation of both incident and scattered beams by about 2.828 mm of diamond (∼0.048), the attenuation of the incident beam by the Be lenses (∼0.7), the difference in optical path length in air between the ambient- and high-pressure experiments, and also the decrease of the solid angle because of the pinhole.
In order to compare the spectra at 3 GPa and ambient pressure, we normalize the spectral intensity to the integrated intensity at 5–8 eV, based on the assumption that the spectral weight at high energy loss is unchanged with pressure. In Fig. 5(c) we compare the normalized RIXS spectra at the two momenta. Two excitations in the RIXS spectra of two-leg ladder cuprate were identified in the few-eV region (Ishii et al., 2007). While the intraband excitation in the Zhang–Rice singlet band appears around 1 eV, the excitation across the Mott gap, more precisely an excitation from the Zhang–Rice singlet band to the upper Hubbard band, appears above 2 eV. Differences between the line shapes of the ambient-pressure and the 3 GPa spectra are apparent. For both momenta the two spectra are found to intersect each other at 2 eV. We ascribe this phenomenon to a simultaneous occurrence of an enhancement of the intraband excitation and a change of the excitations across the Mott gap. We note that a similar behavior was observed in the temperature dependence of the RIXS spectra of Sr14Cu24O41 (Yoshida et al., 2010). Based on the analogy with the temperature-dependent results, we suggest that the high-pressure RIXS data may indicate that the number of holes in the ladders increases with pressure. More work at high pressure is needed to confirm the origin of this behavior.
6. Summary
We have developed the RIXS technique for high-pressure single-crystal experiments. To this end we introduced two devices in a regular optical system at BL11XU, SPring-8: Be lenses and a pinhole. We can obtain better focusing incident X-rays with Be lenses, and, with a pinhole as a post-sample slit system, we could suppress parasitic signals mainly from the diamond. Subsequently, we have performed high-pressure single-crystal RIXS experiments for Sr2.5Ca11.5Cu24O41. We found that changes of the excitations across the Mott gap and enhancement of the intraband excitation occur with pressure qualitatively.
Acknowledgements
We would like to acknowledge A. Q. R. Baron for the use of the Be lenses and K. Ohwada for technical assistance with the DAC. We thank NSRRC, Taiwan, for providing us with beam time for preliminary experiments at BL12XU/SPring-8. The synchrotron radiation experiments at SPring-8 were performed at BL11XU (proposals Nos. 2010A3502, 2010B3502 and 2011A3502) and BL12XU (proposal No. 2011A4261) with the approval of the Japan Synchrotron Radiation Research Institute (JASRI).
References
Ament, L. J. P., van Veenendaal, M., Devereaux, T. P., Hill, J. P. & van den Brink, J. (2011). Rev. Mod. Phys. 83, 705. Web of Science CrossRef Google Scholar
Caliebe, W. A., Soininen, J. A., Shirley, E. L., Kao, C.-C. & Hämäläinen, K. (2000). Phys. Rev. Lett. 84, 3907–3910. Web of Science CrossRef PubMed CAS Google Scholar
Farber, D. L., Krisch, M., Antonangeli, D., Beraud, A., Badro, J., Occelli, F. & Orlikowski, D. (2006). Phys. Rev. Lett. 96, 115502. Web of Science CrossRef PubMed Google Scholar
Hasan, M. Z., Isaacs, E. D., Shen, Z.-X., Miller, L. L., Tsutsui, K., Tohyama, T. & Maekawa, S. (2000). Science, 288, 1811–1814. Web of Science CrossRef PubMed CAS Google Scholar
Hemley, R. J., Mao, H.-k., Shen, G., Badro, J., Gillet, P., Hanfland, M. & Häusermann, D. (1997). Science, 276, 1242–1245. CrossRef CAS Web of Science Google Scholar
Hill, J. P., Blumberg, G., Kim, Y.-J., Ellis, D. S., Wakimoto, S., Birgeneau, R. J., Komiya, S., Ando, Y., Liang, B., Greene, R. L., Casa, D. & Gog, T. (2008). Phys. Rev. Lett. 100, 097001. Web of Science CrossRef PubMed Google Scholar
Hiraoka, N. & Cai, Y. Q. (2010). Synchrotron Radiat. News, 23, 26–31. CrossRef Google Scholar
Ishii, K., Ishihara, S., Murakami, Y., Ikeuchi, K., Kuzushita, K., Inami, T., Ohwada, K., Yoshida, M., Jarrige, I., Tatami, N., Niioka, S., Bizen, D., Ando, Y., Mizuki, J., Maekawa, S. & Endoh, Y. (2011). Phys. Rev. B, 83, 241101. CrossRef Google Scholar
Ishii, K., Tsutsui, K., Tohyama, T., Inami, T., Mizuki, J., Murakami, Y., Endoh, Y., Maekawa, S., Kudo, K., Koike, Y. & Kumagai, K. (2007). Phys. Rev. B, 76, 045124. CrossRef Google Scholar
Kao, C.-C., Caliebe, W. A. L., Hastings, J. B. & Gillet, J.-M. (1996). Phys. Rev. B, 54, 16361. CrossRef Google Scholar
Kim, Y.-J., Hill, J. P., Yamaguchi, H., Gog, T. & Casa, D. (2010). Phys. Rev. B, 81, 195202. CrossRef Google Scholar
Kojima, K. M., Motoyama, N., Eisaki, H. & Uchida, S. (2001). J. Electron Spectrosc. Relat. Phenom. 117–118, 237–250. Web of Science CrossRef CAS Google Scholar
Loa, I., Lundegaard, L. F., McMahon, M. I., Evans, S. R., Bossak, A. & Krisch, M. (2007). Phys. Rev. Lett. 99, 035501. Web of Science CrossRef PubMed Google Scholar
Piermarini, G., Block, S., Barnett, J. & Forman, R. (1975). J. Appl. Phys. 46, 2774–2780. CrossRef CAS Web of Science Google Scholar
Protopopov, V. & Valiev, K. (1998). Opt. Commun. 151, 297–312. Web of Science CrossRef CAS Google Scholar
Raymond, S., Bouchet, J., Lander, G. H., Le Tacon, M., Garbarino, G., Hoesch, M., Rueff, J.-P., Krisch, M., Lashley, J. C., Schulze, R. K. & Albers, R. C. (2011). Phys. Rev. Lett. 107, 136401. Web of Science CrossRef PubMed Google Scholar
Raymond, S., Rueff, J.-P., D'Astuto, M., Braithwaite, D., Krisch, M. & Flouquet, J. (2002). Phys. Rev. B, 66, 220301. CrossRef Google Scholar
Rueff, J.-P. & Shukla, A. (2010). Rev. Mod. Phys. 82, 847–896. Web of Science CrossRef CAS Google Scholar
Sasaki, S. (1990). KEK Report 90–16, pp. 1–143. KEK, Japan. Google Scholar
Shukla, A., Rueff, J.-P., Badro, J., Vanko, G., Mattila, A., de Groot, F. M. F. & Sette, F. (2003). Phys. Rev. B, 67, 081101. CrossRef Google Scholar
Snigirev, A., Kohn, V., Snigireva, I. & Lengeler, B. (1996). Nature (London), 384, 49–51. CrossRef CAS Web of Science Google Scholar
Verbeni, R., Pylkkänen, T., Huotari, S., Simonelli, L., Vankó, G., Martel, K., Henriquet, C. & Monaco, G. (2009). J. Synchrotron Rad. 16, 469–476. Web of Science CrossRef CAS IUCr Journals Google Scholar
Yoshida, M., Ishii, K., Ikeuchi, K., Jarrige, I., Murakami, Y., Mizuki, J., Tsutsui, K., Tohyama, T., Maekawa, S., Kudo, K., Koike, Y. & Endoh, Y. (2010). Physica C, 470, S145–S146. CrossRef CAS Google Scholar
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.