Measurement of the X-ray mass attenuation coefficients of silver in the 5–20 keV range

CROSSMARK_Color_square_no_text.svg

aSchool of Physics, University of Melbourne, Australia, bSchool of Chemistry, University of Melbourne, Australia, and cSchool of Physics, La Trobe University, Australia
*Correspondence e-mail: chantler@unimelb.edu.au

(Received 14 June 2013; accepted 27 August 2013; online 7 February 2014)

The X-ray mass attenuation coefficients of silver were measured in the energy range 5–20 keV with an accuracy of 0.01–0.2% on a relative scale down to 5.3 keV, and of 0.09–1.22% on an absolute scale to 5.0 keV. This analysis confirms that with careful choice of foil thickness and careful correction for systematics, especially including harmonic contents at lower energies, the X-ray attenuation of high-Z elements can be measured with high accuracy even at low X-ray energies (<6 keV). This is the first high-accuracy measurement of X-ray mass attenuation coefficients of silver in the low energy range, indicating the possibility of obtaining high-accuracy X-ray absorption fine structure down to the L1 edge (3.8 keV) of silver. Comparison of results reported here with an earlier data set optimized for higher energies confirms accuracy to within one standard error of each data set collected and analysed using the principles of the X-ray extended-range technique (XERT). Comparison with theory shows a slow divergence towards lower energies in this region away from absorption edges. The methodology developed can be used for the XAFS analysis of compounds and solutions to investigate structural features, bonding and coordination chemistry.

1. Introduction

The development of theoretical and experimental investigations of the interaction of X-rays with atoms has been a continuing effort (Rehr & Albers, 2000[Rehr, J. & Albers, R. (2000). Rev. Mod. Phys. 72, 621-654.]; Joly, 2001[Joly, Y. (2001). J. Phys. B, 63, 125120.]; Chantler, 1995[Chantler, C. T. (1995). J. Phys. Chem. Ref. Data, 24, 71-82.], 2009[Chantler, C. T. (2009). Eur. Phys. J. 169, 147-153.]; Pettifer et al., 1999[Pettifer, R. F., Borowski, M. & Loeffen, P. W. (1999). J. Synchrotron Rad. 6, 217-219.]; Machali et al., 1987[Machali, F., Al-Barakati, G. G., El-Sayed, A. A. & Altaf, W. J. (1987). J. Phys. F, 17, 1279-1284.]; Mica et al., 1985[Mica, J. F., Martin, L. J. & Barnea, Z. (1985). J. Phys. C, 18, 5215-5223.]; Lytle, 2007[Lytle, F. (2007). Synchrotron Radiat. News, 20, 9.]). X-ray mass attenuation coefficients [μ/ρ] and form factors describe the interaction of X-rays with atoms and are widely used. Absolute measurement of [μ/ρ] is of great interest for testing of atomic theories and for comparison with existing tabulations of [μ/ρ] in the literature (e.g. FFAST and XCOM tabulations). X-ray mass attenuation coefficients are used in medical science to generate X-ray images and computed tomography (Lee et al., 1991[Lee, M. J., Hahn, P. F., Papanicolaou, N., Egglin, T. K., Saini, P. R., Mueller, S. & Simeone, J. F. (1991). Radiology, 179, 415-418.]). Measurements of X-ray mass attenuation coefficients are also important for the study of bonding and local atomic structure of materials and molecules (Han et al., 2002[Han, S. W., Stern, E. A., Haskel, D. & Moodenbaugh, A. R. (2002). Phys. Rev. B, 66, 094101.]; Ignatov et al., 2001[Ignatov, A., Yu, Ali, N. & Khalid, S. (2001). Phys. Rev. B, 64, 014413.]), of the density of electronic states (Hossain et al., 2005[Hossain, F., Riley, D. & Murch, G. (2005). Phys. Rev. B, 72, 235101.]) and to test predictions of the photoabsorption (Gerward et al., 1979[Gerward, L., Thuesen, G., Stibius Jensen, M. & Alstrup, I. (1979). Acta Cryst. A35, 852-857.]; Gerward, 1989[Gerward, L. (1989). Acta Cryst. A45, 1-3.]; Karabulut et al., 2005[Karabulut, A., Gurol, A., Budak, G. & Ertugrul, M. (2005). Nucl. Instrum. Methods Phys. Res. B, 227, 485-489.]) and elastic scattering (Hopersky et al., 2004[Hopersky, A. N., Petrov, I. D., Nadolinsky, A. M., Yavna, V. A. & Koneev, R. V. (2004). J. Phys. B, 37, 3313-3320.]; Khoperskii et al., 2005[Khoperskii, A., Nadolinskii, A., Yavna, V. & Koneev, R. (2005). Opt. Spectrosc. 98, 161-165.]) using bound state electron wavefunctions. Recently, nano-roughness measurement of thin foils has also become possible using X-ray mass attenuation data (Glover et al., 2009[Glover, J. L., Chantler, C. T. & de Jonge, M. D. (2009). Phys. Lett. A, 373, 1177-1180.]). Measurements of X-ray mass attenuation coefficients have, therefore, been a subject of great interest of several research groups around the world.

This work measures [μ/ρ] in the region between the K and L1 absorption edges of silver and tests the XERT (X-ray extended-range technique) for its suitability for high-accuracy XAFS measurements of such a high-Z element. We also extend measurements of the absorption of silver to lower energies, down to 5 keV, close to its L edge at 3.8 keV. To do this, we tested a number of foils between 5 µm and 100 µm thick for their suitability for accurate measurements at these lower energies. The thinnest 5 µm foil is well suited for accurate measurements at these low energies and will enable us to extend XAFS measurements to the K and L edges using silver foils and silver compounds in solution.

To confirm the high-accuracy in the present measurements, error analysis was performed for experimental systematics relating to dark-current, air-path attenuation, harmonic contamination and energy calibration; statistical reliability is a key question central to the application of XAFS for structural analysis of elements and compounds (Chantler et al., 2012[Chantler, C. T., Rae, N. A., Islam, M. T., Best, S. P., Yeo, J., Smale, L. F., Hester, J., Mohammadi, N. & Wang, F. (2012). J. Synchrotron Rad. 19, 145-158.]).

2. Experimental

The XERT (Chantler, 2009[Chantler, C. T. (2009). Eur. Phys. J. 169, 147-153.]; Chantler et al., 2001[Chantler, C. T., Tran, C. Q., Paterson, D. & Barnea, Z. (2001). Phys. Lett. A, 286, 338-346.]; de Jonge et al., 2006[Jonge, M. D. de, Tran, C. Q., Chantler, C. T. & Barnea, Z. (2006). Opt. Eng. 45, 046501.]) has been used for the high-accuracy measurement of mass attenuation coefficients of various elements, of form factors and X-ray absorption fine structure (XAFS), and has produced some of the most accurate measurements of mass attenuation coefficients (de Jonge et al., 2005[Jonge, M. D. de, Tran, C. Q., Chantler, C. T., Barnea, Z., Dhal, B. B., Cookson, D. J., Lee, W. K. & Mashayekhi, A. (2005). Phys. Rev. A, 71, 032702.]; Glover et al., 2008[Glover, J. L., Chantler, C. T., Barnea, Z., Rae, N. A., Creagh, D. C., Paterson, D. & Dhal, B. B. (2008). Phys. Rev. A, 78, 052902.]; Rae et al., 2010[Rae, N. A., Chantler, C. T., Barnea, Z., de Jonge, M. D., Tran, C. Q. & Hester, J. R. (2010). Phys. Rev. A, 81, 022904.]; Islam et al., 2010[Islam, M. T., Rae, N. A., Glover, J. L., Barnea, Z., de Jonge, M. D., Tran, C. Q., Wang, J. & Chantler, C. T. (2010). Phys. Rev. A, 81, 022903.]). XERT measurements are performed over an extended range of experimental parameters allowing the determination of sources of systematic errors such as scattering and fluorescence (Tran et al., 2004[Tran, C. Q., de Jonge, M. D., Barnea, Z. & Chantler, C. T. (2004). J. Phys. B, 37, 3163-3176.]), harmonic content (Barnea & Mohyla, 1974[Barnea, Z. & Mohyla, J. (1974). J. Appl. Cryst. 7, 298-299.]), energy drift (Glover et al., 2010[Glover, J. L., Chantler, C. T., Barnea, Z., Rae, N. A. & Tran, C. Q. (2010). J. Phys. B, 43, 085001.]), bandwidth (de Jonge et al., 2004a[Jonge, M. D. de, Barnea, Z., Tran, C. Q. & Chantler, C. T. (2004a). Phys. Rev. A, 69, 022717.]), dark current and the attenuation by the detectors and by the air path.

Fig. 1[link] represents a schematic of the experimental set-up at the ANBF, Tsukuba, Japan. In this work, the mass attenuation of silver was measured using an X-ray beam produced by a bending magnet at beamline 20B of the Photon Factory in Tsukuba, Japan. The X-ray beam was monochromated by a double-crystal monochromator using a monolithic silicon 111 crystal located in the first optical enclosure. The monochromated X-rays were passed through a pair of orthogonal adjustable slits for defining the beam cross-section (approximately 2 mm × 1.5 mm).

[Figure 1]
Figure 1
Schematic diagram of the experimental set-up for using the XERT at the ANBF, Tsukuba, Japan. The BigDiff powder diffractometer upstream (to the left) allows energy calibration using standard powder samples. The two daisy wheels (upstream and downstream) monitor harmonic contamination and scattering contributions.

Matched ion chambers were located upstream and downstream from the attenuating silver foils and were run using a flow of nitrogen gas. The beam intensity was continuously monitored. To achieve high precision, each of the measurements was repeated at least ten times. The monochromator was set to produce photons of energy well above 20 keV and then gradually stepped down to lower energies during the attenuation measurements to avoid effects of backlash.

The sample stage was configured so that it could hold three silver samples and translate and rotate them about horizontal and vertical axes perpendicular to the beam. Two daisy wheels containing 15 aluminium foils each around its perimeter were mounted between the sample stage and the two ion chambers. The aluminium foils had thicknesses varying over several orders of magnitude and allowed us to record additional information about thickness dependence of systematic errors.

2.1. The silver foil samples

A total of seven silver foils with nominal thicknesses ranging from 5 µm to 275 µm were used to measure the X-ray mass attenuation coefficients of the silver foils. The foils were supplied by Goodfellow with claimed purity of 99.99%. The masses and areas of the foils were determined from repeated measurements using a microgram balance and an optical comparator, respectively. The average for each foil was used with a respective standard error determined from the variance of the repeated measurements. Of the two 100 µm foils, the foil in the 15–20 keV energy range (Fig. 4) was used as the reference with a determined mass M = 0.6911 g ± 0.000001 (0.0014%) and area A = 6.493 cm2 ± 0.0019 (0.03%). The average integrated column density [ρt]av of the reference foil was found to be [ρt]av = 0.10644 g cm−2 ± 0.00003 (0.03%) from the ratio of the mass M to the area A of the foil. We identify the foils by their nominal thicknesses, but of course only measured values were used in the analysis.

3. Analysis details

3.1. Dark-current analysis

Dark currents were recorded by the ion chambers at each of the energies to correct for its effect on sample attenuations. The dark current is a function of time and has been shown to have significant effect on the attenuation measurements (Glover & Chantler, 2007[Glover, J. L. & Chantler, C. T. (2007). Meas. Sci. Technol. 18, 2916-2920.]). For the first time, a stepwise fitting procedure was followed to fit the recorded dark currents at two successive energies with respect to the time difference between the two measurements using a covariance matrix. The fitted dark currents were then subtracted from measurements recorded with and without the foil in both upstream and downstream ion chambers. This new approach to dark-current fitting produced greater consistency and lower χ2 values, thereby allowing reduction of uncertainty contributions from this particular source of systematic error.

3.2. Determination of integrated column density

The accurate determination of the integrated column density [ρt]c along the beam path is crucial for the determination of the X-ray mass attenuation coefficients [μ/ρ]. The present analysis used two different methods, i.e. full-foil mapping (de Jonge et al., 2004b[Jonge, M. D. de, Tran, C. Q., Chantler, C. T., Barnea, Z., Dhal, B. B., Cookson, D. J., Lee, W. K. & Mashayekhi, A. (2004b). Meas. Sci. Technol. 15, 1811-1822.]) and `central-region mapping' (Tran et al., 2003b[Tran, C. Q., Chantler, C. T. & Barnea, Z. (2003b). Phys. Rev. Lett. 90, 257401.],c[Tran, C. Q., Chantler, C. T., Barnea, Z., Paterson, D., Cookson, D. J. & Balaic, D. X. (2003c). Phys. Rev. A, 67, 042716.]; Rae et al., 2010[Rae, N. A., Chantler, C. T., Barnea, Z., de Jonge, M. D., Tran, C. Q. & Hester, J. R. (2010). Phys. Rev. A, 81, 022904.]) of the foil, to determine the integrated column density [ρt]c of the reference foil of nominal 100 µm thickness at the (central) point through which the 2 mm × 1.5 mm X-ray beam passed. The integrated column densities determined by the two methods were consistent. Table 1[link] and the rest of the paper uses the results of the full-foil mapping technique because of the lower uncertainty in the determined [ρt]c.

Table 1
Integrated column density [ρt]c of reference foils of nominal thickness tnom

Integrated column density of the reference foil was determined to be 0.108067 ± 0.000101(0.09%) using equation (1)[link]. Integrated column densities [ρt] of the foils were fitted implementing the Levenberg Marquardt algorithm [equation (3)[link]]. Several foils (100 µm, 10 µm, 50 µm and 5 µm foils) were fitted separately to correct for the effect of hysteresis due to multiple measurements and a non-monotonic cycling at 16.5 keV and 16 keV. There were two separate 100 µm foils [100 (1) and 100 (2)], and fitted results prior to hysteresis are labelled (a) while results after the hysteretic loop are labelled (b). The uncertainties of the column densities were determined by multiplying [({\chi^2_r})^{1/2}] with the fitted standard errors. [\chi^{2}_r] was large at this stage of analysis due to significant roughness and harmonic systematics, which are corrected and optimized as discussed in the text.

tnom (µm) Fitted values [ρt]c (g cm−2) Energy range (keV)
275 0.29221 ± 0.00106 17.00–20.00
100 (1a) 0.10813 ± 0.00031 17.00–20.00
100 (1b) 0.10740 ± 0.00074 16.00–16.50
100 (2) 0.10639 ± 0.00048 15.00–17.00
50a 0.05313 ± 0.00012 17.00–20.00
50b 0.05325 ± 0.00027 13.40–16.50
12 0.01328 ± 0.00007 5.00–17.00
10a 0.01137 ± 0.00009 16.00–17.00
10b 0.01133 ± 0.00006 5.00–16.50
5a 0.00501 ± 0.00004 15.00–16.50
5b 0.00503 ± 0.00003 5.00–16.00

The attenuations across the area of the foil were measured using an X-ray raster scan with the 2 mm × 1.5 mm beam size. The average [μ/ρ][ρt]av of the attenuations [μ/ρ][ρt]i across the area and the attenuation at the central point used for all attenuation measurements were determined from the obtained attenuation map of the foil. This followed the modelling of the foil and a fitting procedure applied to the experimental data. The mass m and area A of the foil were used to determine the average integrated column density [ρt]av. Finally, the information was used in equation (1)[link] to determine the integrated column density [ρt]c and the corresponding uncertainty of the reference foil,

[\eqalign{ [\rho t]_{\rm{c}} & = {{ \left[{\mu}/{\rho}\right][\rho t]_{\rm{c}} }\over{ [{\mu}/{\rho}][\rho t]_{\rm{av}} }} \,[\rho t]_{\rm{av}}, \cr \sigma_{[\rho t]_{\rm{c}}} & = \left[ \left({{\sigma_{[\mu t]_{\rm{c}}}} \over {[\mu t]_{\rm{c}}}}\right)^2 \,+\,\, \left({{\sigma_{[\mu t]_{\rm{av}}}} \over {[\mu t]_{\rm{av}}}}\right)^2 \,+ \,\,\left({{\sigma_{[\rho t]_{\rm{av}}}} \over {[\rho t]_{\rm{av}}}}\right)^2\right]^{1/2}.}\eqno(1)]

3.3. Modelling of the foil and removing the effect of the attenuation of the sample holder

To mount each of the silver foils, a Perspex sample holder was used which also attenuated the X-ray beam (Fig. 2[link]). The average attenuation of the foil was obtained following the subtraction of the attenuation of the Perspex holder used for mounting the foil. In order to remove the effect of the attenuation of the holder, a model of the attenuation of the foil and holder was constructed and fitted to the experimental data (Fig. 3[link]). A square-shaped foil was modelled with two parameters (x0, y0) as the central position where x and y describe its axes. The model was then fitted to the experimental data of X-ray attenuations across the entire area of the reference foil. The raster scan mapped the foil completely in both x and y directions. The thickness profile of the modelled foil was considered to have the attenuation of a truncated wedge-shaped foil described by Glover et al. (2010)[Glover, J. L., Chantler, C. T., Barnea, Z., Rae, N. A. & Tran, C. Q. (2010). J. Phys. B, 43, 085001.],

[\left[{{\mu}/{\rho}}\right][\rho t]_{{\rm{modelled}}_{\rm{foil}}} = \left[{{\mu}/{\rho}}\right][\rho t]_0 + m_x(x - x_0) + m_y(y - y_0),\eqno(2)]

where [μ/ρ][ρt]0 represents the attenuation at the central point (x0, y0) of the foil. The gradients of the wedge in the x and y directions are represented by the parameters mx and my.

[Figure 2]
Figure 2
Model of the sample holder. The Perspex transmission must be removed to reveal the map of the foil.
[Figure 3]
Figure 3
Model of the 100 µm-thick reference silver foil. The blue-shaded square shows the area of the foil over which the X-ray raster scan was performed and the small rectangular grids represent the size and footprint of the X-ray beam for the attenuation measurements of the full-foil mapping.

3.4. Determining the average and central-point attenuations, and uncertainties

The attenuation of the well defined holder was then subtracted from the fitted data to obtain the attenuation of the foil (Fig. 4[link]). For the accurate determination of the average attenuation of the foil, the average of all individual attenuations across the scanned portion of the foil was determined. Details of the procedure are described by Glover et al. (2010)[Glover, J. L., Chantler, C. T., Barnea, Z., Rae, N. A. & Tran, C. Q. (2010). J. Phys. B, 43, 085001.]. The standard error determined from the measurements across the foil was taken as the uncertainty of the average attenuation [μ/ρ][ρt]av.

[Figure 4]
Figure 4
Measured attenuation of the foil after subtraction of the modelled attenuation of the sample holder from the fitted full-foil attenuation. The pixels across the map represent the X-ray beam size of 2 mm × 1.5 mm and the colours indicate small thickness variations inevitable in all foils.
3.4.1. The central point attenuation and uncertainty

The area scan of the reference foil (100 µm) was performed with single-point measurements at 17 keV.

The central point attenuation of the reference foil incorporated information of repeated measurements of the central point together with the single-point measurements over the full-foil map,

[\left[{{\mu}/{\rho}}\right][\rho t]_{\rm{c}} = \left(\textstyle\sum\limits_N \left[{{\mu}/{\rho}}\right][\rho t]\right)/N.]

The central-point attenuation was obtained to be 3.039249 ± 0.000278. The average attenuation [μ/ρ][ρt]av was determined from the average of all measurements across the area map shown in Fig. 4[link], and found to be 2.993479 ± 0.002679. The obtained average and central-point attenuations were then used to determine the absolute integrated column density [ρt]c of the reference foil along the beam.

3.5. Determining the integrated column densities [ρt]c of the foils relative to the reference foil

A total of seven silver foils were used including the reference foil for the measurements. The full-foil map of the reference foil was used to determine the column densities [ρt] of the other foils using a fitting procedure.

A hysteretic effect occurred due to a non-monotonic energy cycling. Therefore, we fitted the foils before and after the hysteretic loop. Hence a total of 11 foils were fitted. For instance, the 50 µm foil was fitted over two independent ranges applied at energies before and after 16.5 keV. Similarly, the 10 µm and 12 µm foils were divided into multiple thicknesses to correct for the hysteresis effect across repeated energies 16.5 keV and 16 keV. This approach improved consistency between the weighted mean [μ/ρ]wm and the individual measurements [μ/ρ]i of the foils using two aperture sizes.

The local consistency between the [μ/ρ] of different foils and the result with the full-foil mapping is maintained to minimize χ2 following

[\chi^2= \sum\limits_{E_{\rm{i}}}\sum\limits_{S_{\rm{i}}} \left({{[\mu/\rho]_{E_{\rm{i}},S_{\rm{i}}} - [\mu/\rho]_{\rm{wm}}} \over {\sigma_{[\mu/\rho]_{E_{\rm{i}},S_{\rm{i}}}}}} \right)^2,\eqno(3)]

where [[\mu/\rho]_{E_{\rm{i}},S_{\rm{i}}}] is the mass attenuation coefficient of the sample Si at energy Ei with the associated uncertainty [\sigma_{[\mu/\rho]_{E_{\rm{i}},S_{\rm{i}}}}], and [μ/ρ]wm is the weighted mean of [[\mu/\rho]_{E_{\rm{i}},S_{\rm{i}}}] of all foils and aperture-dependent measurements at that energy.

3.6. Determining X-ray attenuation

X-ray intensities were recorded using an upstream (u) and a downstream (d) ion chamber with a sample placed in the path of the X-ray beam, without a sample, and shuttering the X-ray beam for dark-current measurements. Intensities without a sample in the path of the X-ray beam (blank measurements) were also recorded to characterize the air-path attenuation for the X-ray beam travelling the path between the ion chambers. X-ray intensities recorded with the sample, without the sample and the dark current were then used to determine the accurate X-ray attenuation of the sample.

Recorded intensities with the sample and without sample were normalized by subtracting the recorded dark current at each of the energies and used for determining the X-ray beam intensity for both samples and blanks (as a function of energy). The procedure of dark-current fitting and subtraction is discussed in §3.1[link]. The Beer–Lambert law was used for measuring the foil attenuation,

[\left[{{\mu}/{\rho}}\right] [\rho{t}] = -\ln\left[\,\overline{\left({{I_{\rm d} - D_{\rm d}} \over {I_{\rm u} - D_{\rm u}}}\right)}_{\rm s}\,\Big/\overline{\left({{I_{\rm d} - D_{\rm d}} \over {I_{\rm u} - D_{\rm u}}}\right)}_{\rm b}\right],\eqno(4)]

where the subscripts s and b refer to the intensities measured with a sample in the path of the beam and without any sample in the path, respectively. The foil attenuations as a function of energy are shown in Fig. 5[link].

[Figure 5]
Figure 5
Attenuations of seven silver foils with nominal thicknesses ranging from 5 µm to 275 µm, using equation (4)[link], versus nominal monochromator energy. At least three measurements using different thicknesses of foils were made at each energy. Measurements using all the foils were made at 17 keV where the area raster scan of the reference foil (100 µm thick) was made. The attenuation of the various sample thicknesses are represented by the different symbols as indicated.

The uncertainty of attenuation measurements was determined from the uncertainty contributions from dark-current measurements and from the intensities with and without a sample. A total of ten repeated measurements were made for each type of measurement (i.e. dark current, blank and sample measurements). The standard errors of the repeated measurements were used to determine the final uncertainty of the attenuation. Thus, the total uncertainty [\sigma_{[{{\mu}/{\rho}}][\rho t]}] of foil attenuations [[{{\mu}/{\rho}}][\rho t]] was determined as

[\sigma_{[{{\mu}/{\rho}}][\rho t]} = \left[\left({{\sigma_{I_{\rm{dc}}}} \over {I_{\rm{dc}}}}\right)^2 \,+\,\, \left({{\sigma_{(I_{\rm u}/I_{\rm d})}} \over {(I_{\rm u}/I_{\rm d})}}\right)_{\rm s}^2 \,+\,\, \left({{\sigma_{(I_{\rm u}/I_{\rm d})}} \over {I_{\rm u}/I_{\rm d}}}\right)_{\rm b}^2\right]^{1/2},\eqno(5)]

where Idc represents the dark current (i.e. recorded intensity when there is no X-ray beam), and the subscripts s and b denote the measurements with a sample in the beam and without a sample in the beam, respectively. The corresponding uncertainties of the foil attenuation are shown in Fig. 6[link] using the same symbols as in Fig. 5[link] to represent attenuations for foils of different thicknesses.

[Figure 6]
Figure 6
Percentage uncertainties (standard errors) of the foil attenuations versus nominal monochromator energy. Uncertainties typically varied from 0.002% to 0.14% where the larger uncertainties were contributed by the thickest foil of 275 µm used in the 17–20 keV energy range. The uncertainties of the attenuations of the other foils were no larger than 0.05% in the 6–17 keV energy range except at 13 keV reaching up to 0.14% due to beam clipping at that point. With the 10 µm- and 12 µm-thick foils, the uncertainties were relatively high at energies below 6 keV.

3.7. Energy calibration

A key experimental systematic is the energy offset functional caused by the overall hysteresis of the monochromator motor control, which contributes error to the recorded encoder angle of the monochromator (Tantau et al., 2013[Tantau, L. J., Islam, M. T., Payne, A. T., Tran, C. Q., Cheah, M. H., Best, S. P. & Chantler, C. T. (2013). Radiat. Phys. Chem. In the press.]). This is generically true for all motor or monochromator systems and should be characterized regularly. We used a powder diffractometer to measure directly the energies at which the mass attenuation coefficients of silver were measured, which is much more reliable than encoder settings and currently much more reliable than using an uncalibrated standard foil edge of indeterminate thickness. Two NIST powder standards, Si(640b) and LaB6(660), were used, the most accurate standards described in the literature. Energy measurements were carried out at every 1–2 keV covering the range of the energies where the attenuation measurements were performed. Detailed energy measurements have been reported by Rae et al. (2006[Rae, N. A., Chantler, C. T., Tran, C. Q. & Barnea, Z. (2006). Radiat. Phys. Chem. 75, 2063-2066.]). Figs. 7[link] and 8[link] show the difference between nominal and calibrated energies and the associated uncertainties of interpolated energies.

[Figure 7]
Figure 7
Plot of the difference between the calibrated X-ray energy and the nominal X-ray energy. The calibrated energies were determined using powder diffraction measurements performed on two standard powders, silicon and LaB6 (red error bars for specific points). Below 11 keV only the LaB6 powder diffraction patterns produced useful results. The known lattice parameter of the silicon standard and its ratio to the LaB6 standard were used to determine the energies of the beam. A linear interpolation was then applied to obtain all the energies at which the X-ray mass attenuation coefficients of silver were measured (dashed lines show one standard error upper and lower limits).
[Figure 8]
Figure 8
The standard error [\delta E] represents the uncertainties of the interpolated measured energies. A covariance matrix was used to determine the variances.

A least-squares procedure was performed to fit the differences between the nominal and calibrated energies. For determining the calibrated energy of every attenuation measurement, the best-fit parameters were used. The uncertainties of the interpolated energies were less than 0.62 eV.

4. Effect of harmonic contamination, roughness and their corrections

A 0.01–30% harmonic contamination was observed at lower energies from 8 keV down to 5 keV, which is the highest harmonic contamination observed by our group. This large higher-order harmonic contamination required special treatment for its correction. We investigated two methodologies to determine the contribution of harmonic contamination as harmonic fraction. The `sample method' used the attenuations of the three main silver foils in the regions of harmonic contamination (10 µm, 12 µm and 5 µm), while the `daisy-wheel method' used 14 aluminium foils with different thicknesses as mounted on the daisy wheel for harmonic and scattering signatures. Both methods found similar levels of contamination across the range of energies to within a few standard deviations. However, the `sample method' underestimated the correction, in part because of the sparse information with only three data points per energy. The daisy-wheel method, however, slightly overestimated the harmonic correction, despite a large number of independent measurements (14), in part due to the mismatch between sample and foil attenuation and the different location. Therefore, we investigated the pattern of discrepancies across the range between these estimates in order to minimize the variance. Several patterns were investigated; the optimum fit to the full data set was found using 0.808 times the estimated harmonic fraction from the daisy-wheel method. This approach achieved 0.09–1.22% accuracy in [μ/ρ] across the full range of energies and samples, and is reported in this paper. We note that there is obviously a residual systematic variance associated with this harmonic, which is dominated at the lowest three measured energies where the correction and its uncertainty are greatest; as such, the residual variance correctly estimates the uncertainty of the corrections in those regions.

4.1. Harmonic contamination and correction

When a monochromator is set to select a particular energy of X-rays, higher-order reflections may also contribute harmonic components to the incident X-ray beam (Tran et al., 2003a[Tran, C. Q., Barnea, Z., de Jonge, M. D., Dhal, B. B., Paterson, D., Cookson, D. J. & Chantler, C. T. (2003a). X-ray Spectrom. 32, 69-74.]; Barnea & Mohyla, 1974[Barnea, Z. & Mohyla, J. (1974). J. Appl. Cryst. 7, 298-299.]). These harmonic components were characterized at each of the energies where sample attenuations were measured using a set of aluminium filters. An upstream daisy wheel was used in the experimental set-up to measure the attenuations of 15 aluminium foils mounted around the perimeter of the daisy wheel with thicknesses ranging from 10 µm to 4000 µm. Harmonic components were detected at energies lower than 6.5 keV (Fig. 9[link]).

[Figure 9]
Figure 9
Fractional harmonic contributions at each of the energies at which the X-ray mass attenuation coefficients of silver were measured, based on the daisy-wheel method as discussed in the text. Clearly, the effect of harmonic contamination is noticeable at about 7 keV and increases with decreasing energy.

We used the FFAST tabulated X-ray mass attenuation coefficients of aluminium to characterize and correct for the effect of harmonic components in the X-ray beam. In the presence of harmonic components of energy En, the total transmission probability I/I0 equals the sum of the transmission probabilities for each of the energy components [\exp(-[{{\mu}/{\rho}}]_{E_n}[\rho{t}])] weighted by the relative intensity of each component in the incident beam and the relative detection efficiency for each energy component. If a fundamental energy E1 is contaminated by only one harmonic component of energy En, the measured attenuation is given by

[\eqalignno{ \exp\left\{-\left[{{\mu}/{\rho}}\right][\rho{t}] \right\} = {}& (1-f_n)\exp\left\{-\left[{{\mu}/{\rho}}\right]_{E_1}[\rho{t}]\right\} \cr& +\,\,f_n \exp\left\{-\left[{{\mu}/{\rho}}\right]_{E_n}[\rho{t}]\right\},&(6)}]

where fn is the fraction of the harmonic component of energy En present in the fundamental energy.

4.1.1. Fitting procedure and correction

With the use of this model, we fitted five parameters (harmonic fraction fn; attenuation [[{{\mu}/{\rho}}][\rho t]_{E_1}] for fundamental energy E1; attenuation [[{{\mu}/{\rho}}][\rho t]_{E_3}] for the third-order energy E3; a dark current correction; and an offset) to obtain the harmonic effect on the measurements. To obtain the best fit with the lowest [\chi^2_r], the [[{{\mu}/{\rho}}][\rho t]_{E_3}] parameter was constrained to the FFAST tabulated values at higher energies and was free at lower energies, while the critical output [[{{\mu}/{\rho}}][\rho t]_{E_1}] was free for all energies. The dark-current correction and offset were consistent with zero. Following this procedure, harmonic contamination was found to be smooth and monotonic at lower energies <7 keV whereas at higher energies no harmonic contamination was detected. At 5 keV, the obtained harmonic fraction was fn = 0.0029 ± 0.00011; the attenuation coefficient for the fundamental energy was [[{{\mu}/{\rho}}][\rho t]_{E_1}] and [({\chi^2_r})^{1/2}] was found to be 0.0512 at 5 keV. The highest contribution was found at 5 keV (0.29%). The harmonic effect on the attenuations of silver foil was then corrected for making use of the fractional harmonic contribution at each of the energies by reversing equation (6)[link]. This subtracts the attenuation for the higher-order Bragg peaks from the attenuation for the fundamental energy, thereby correcting for the harmonic contamination to the fundamental measurement. Harmonic effects up to 15% at energies lower than 7 keV were observed with two foils (10 µm and 12 µm).

This is the highest level of harmonic correction thus far achieved through applying this method.

4.2. Roughness correction

Attenuation of the 10 µm foil was affected by roughness, which was clear from the residual signature of the foil.

The roughness r.m.s. of the 10 µm foil was found to be 1.1 µm for the energy range 7–17 keV, for which the mass attenuation coefficient of the foil was corrected (Glover et al., 2008[Glover, J. L., Chantler, C. T., Barnea, Z., Rae, N. A., Creagh, D. C., Paterson, D. & Dhal, B. B. (2008). Phys. Rev. A, 78, 052902.]).

4.3. Effects of fluorescence

The interaction between X-rays with energies higher than that of the silver L1 edge and the silver samples can produce fluorescent photons. The present measurements were made in the 5–20 keV energy range which does not contain any absorption edge but the energies fall in between the L1 and K edges which can produce fluorescent photons due to the X-rays with energies higher than the L1 edge. The fraction of fluorescent photons scattered can be determined from aperture-dependent measurements (Glover et al., 2008[Glover, J. L., Chantler, C. T., Barnea, Z., Rae, N. A., Creagh, D. C., Paterson, D. & Dhal, B. B. (2008). Phys. Rev. A, 78, 052902.]; de Jonge et al., 2005[Jonge, M. D. de, Tran, C. Q., Chantler, C. T., Barnea, Z., Dhal, B. B., Cookson, D. J., Lee, W. K. & Mashayekhi, A. (2005). Phys. Rev. A, 71, 032702.]). To observe the effect of scattering, each of the scattered intensities was recorded using two different-sized apertures located on the daisy wheels between the samples and ion chambers (Fig. 10[link]).

[Figure 10]
Figure 10
Effect of fluorescence on the measurements for the 12 µm-thick foil. A maximum of 0.025% fluorescence contribution was determined from the percentage difference in the measurements using two different-sized apertures.

As expected, away from absorption edges the fluorescence correction was almost negligible (0.025%) (Fig. 10[link]).

4.4. Aperture- and thickness-dependent consistency of the results

At each of the measured energies, multiple values of the X-ray mass attenuation coefficient [μ/ρ] of silver were obtained by the use of multiple thicknesses, and two different-sized apertures on the daisy wheels allowed aperture-dependent measurements. We tested the consistency of the obtained X-ray mass attenuation coefficients of silver using those multiple measurements at each of the energies. For this consistency test, the percentage variation between the weighted mean and individual values was investigated (Fig. 11[link]).

[Figure 11]
Figure 11
Consistency between the measurements for different foil thicknesses and aperture sizes. This represents the percentage difference between [μ/ρ] of the individual foil and aperture measurements and their weighted mean at each of the energies. The 10 µm- and 12 µm-thick foils showed relatively good consistency at energies lower than 5.6 keV and consistency with the thinnest foil (5 µm) was found to be excellent throughout the energy range of measurements. A 10–25% harmonic contamination was found at lower energies, <8 keV, and correction was made to attain good consistency. The thickest foil (12 µm) in this energy range was affected most by the harmonic content.

Excellent consistency was achieved within 0.1% from 6 keV to 17 keV, with somewhat poorer consistency found below 6.5 keV and above 17 keV. The measurements below 6.5 keV contributed slightly larger uncertainties with the 10 µm and 12 µm foils, possibly due to incomplete subtraction of harmonic contributions. At the lowest two to three energies measured the influence of several systematics increases the variance and uncertainty.

4.5. Comparison of this work with theories and other experiments

The US National Institute for Standards and Technology (NIST) recommends two theoretical tabulations, FFAST (Chantler, 1995[Chantler, C. T. (1995). J. Phys. Chem. Ref. Data, 24, 71-82.], 2000[Chantler, C. T. (2000). J. Phys. Chem. Ref. Data, 29, 597-1048.]) and XCOM (Berger et al., 1998[Berger, M. J., Hubbell, J. H., Seltzer, S. M., Chang, J., Coursey, J. S., Sukumar, R. & Zucker, D. S. (1998). NIST Stand. Ref. Database, 8, 87-3597.]; Saloman et al., 1988[Saloman, E. B., Hubbell, J. H. & Scofield, J. H. (1988). At. Data Nucl. Data Tables, 38, 1.]), for the photoelectric absorption, and Compton and Rayleigh scattering of X-rays are commonly also used in the calculation of the X-ray mass attenuation coefficient. The measured X-ray mass attenuation coefficients of silver of this work are compared with the FFAST and XCOM tabulated values and found to be within 2% at the higher energies, with discrepancies increasing towards lower energies. The results were also compared with the few other experimental measurements in the literature in this energy range (5–20 keV).

Our results (Figs. 12[link] and Fig. 13[link]) show excellent agreement with the careful work of Tran et al. (2005)[Tran, C. Q., Chantler, C. T., Barnea, Z., de Jonge, M. D., Dhal, B. B., Chung, C. T. Y., Paterson, D. & Wang, J. (2005). J. Phys. B, 38, 89-107.] collected under independent conditions, with agreement to within one standard error across the range 16–20 keV, with a standard error of about 0.1%. The results also confirm a discrepancy with the FFAST tabulation of about 2% at the higher energies, which appears to increase towards lower energies. Comparison of the data with XCOM theory is smoother but also reaches 2%. This is not surprising since the theoretical predictions have an accuracy of order 1%.

[Figure 12]
Figure 12
Comparison of this work with two theories and other experimental measurements. This work is represented by diamonds, Sandiago & Gowa (1997[Sandiago, T. K. U. & Gowa, R. (1997). Pramana, 48, 1077.]) by circles, Tajuddin et al. (1995[Tajuddin, A. A., Chong, C., Shukri, A., Bandyopadhyay, T. & Bradley, A. (1995). Appl. Radiat. Isot. 46, 113-115.]) by triangles and Tran et al. (2005[Tran, C. Q., Chantler, C. T., Barnea, Z., de Jonge, M. D., Dhal, B. B., Chung, C. T. Y., Paterson, D. & Wang, J. (2005). J. Phys. B, 38, 89-107.]) by squares. Two theoretical values FFAST and XCOM are represented by solid and dotted lines. This conventional comparison does not provide information about the discrepancy between the measurements. The following plot of percentage difference of the measurements from the FFAST tabulated values reveals the discrepancy between the measurements and the theories (Fig. 13[link]).
[Figure 13]
Figure 13
Percentage discrepancy between theories and other experimental measurements. This work shows excellent agreement with the careful work of Tran et al. (2005[Tran, C. Q., Chantler, C. T., Barnea, Z., de Jonge, M. D., Dhal, B. B., Chung, C. T. Y., Paterson, D. & Wang, J. (2005). J. Phys. B, 38, 89-107.]) collected under independent conditions, with agreement to within one standard error across the range from 16 keV to 20 keV for a standard error of about 0.1%. The results also confirm a discrepancy between the measurements and the FFAST tabulation of about 2% at the higher energies, which increases towards lower energies. Comparison of the data to XCOM theory shows better agreement but also reaches 3%. This is not surprising since the theoretical predictions have an accuracy of order 1%.

This investigation calls for further investigations of the L1 and K edges of silver using the XERT which is able to obtain high accuracy in the energy ranges across the L1 and K absorption edges.

5. Results and discussion

5.1. The mass attenuation coefficients of silver

The mass attenuation coefficients of silver metal foils were determined by the XERT approach and presented in Table 2[link]. Six silver foils with different thicknesses were used in the energy range between 5 keV and 20 keV. To obtain the final attenuation coefficient [[{{\mu}/{\rho}}]] at a given energy, the weighted mean of [[{{\mu}/{\rho}}]] obtained from the different foil thicknesses and aperture-dependent measurements at that energy was used,

[\left[{{\mu}/{\rho}}\right]= {{\textstyle\sum\limits_{\rm all} {[{\mu}/{\rho}]_{{i}}}/\sigma^2_{[{\mu}/{\rho}]_{{i}}}} \Big/ {\textstyle\sum\limits_{\rm all}{1/\sigma^2_{[{\mu}/{\rho}]_{{i}}}}}},\eqno(7)]

where [[{{\mu}/{\rho}}]_{{i}}] are the measured mass attenuation coefficients obtained from the different thicknesses and [\sigma_{[{{\mu}/{\rho}}]_{{i}}}] are the corresponding errors of the measurements,

[\sigma_{[{{\mu}/{\rho}}]} = \left[{{\textstyle\sum\limits_{{i}}\left\{{([\mu/\rho]_i-\overline{[{\mu}/{\rho}]})}/{\sigma_{[{\mu}/{\rho}]_i}}\right\}^2} \over {(N-1)\textstyle\sum\limits_i{{1}/{\sigma^2_{[{\mu}/{\rho}]_i}}}}} + \left({{\sigma_{[\rho{t}]_{\rm c}}} \over {[\rho{t}]_{\rm c}}}\right)^2\right]^{1/2},\eqno(8)]

where [\overline{[{{\mu}/{\rho}}]}] is the weighted average of the [[{{\mu}/{\rho}}]_i], [\sigma_{[{{\mu}/{\rho}}]_i}] are the corresponding statistical errors in [[{{\mu}/{\rho}}]_i], and N is the number of foils with different thicknesses measured at a given energy.

Table 2
Measured total X-ray mass attenuation coefficients [μ/ρ]t, photoelectric mass absorption coefficients [μ/ρ]pe, imaginary components of the form factor f ′′ and the mass attenuation coefficients for Raleigh and Compton scattering [μ/ρ]R+C of silver in the 5–20 keV energy range, and their corresponding uncertainties.

The first column lists the measured energies (with uncertainties in eV) at which the quantities were determined. The second column lists the total mass attenuation coefficients with absolute uncertainties in parentheses. The third and fourth columns list the corresponding percentage relative and absolute uncertainties. The fifth column lists the photoelectric mass absorption coefficients determined by subtracting the mass attenuation coefficients for Rayleigh and Compton scattering from the total experimental absolute mass attenuation coefficients at the measured energies. The mass attenuation coefficients for Rayleigh and Compton scattering were taken as the average of FFAST and XCOM tabulated values and determined by interpolation at the measured energies. The uncertainty of [μ/ρ]R+C was determined from half of the variation between FFAST and XCOM tabulated values. The uncertainty of [μ/ρ]pe was determined from the uncertainty contributions of [μ/ρ]R+C and [μ/ρ]t. The imaginary components of the form factor were determined using equation (9)[link]. The uncertainty in f ′′ was estimated using equation (10)[link].

Energy (keV) [μ/ρ]t (cm2 g−1) σ([μ/ρ]r) (% absolute) σ([μ/ρ]a) (% absolute) [μ/ρ]pe (cm2 g−1) f ′′ (e atom−1) [μ/ρ]R+C (cm2 g−1)
20.06525 (58) 17.9785 (20) 0.011 0.088 16.740 (11) 0.86101 (56) 1.239 (13)
19.06124 (52) 20.6921 (36) 0.017 0.089 19.373 (11) 0.94660 (55) 1.319 (14)
18.05718 (46) 24.0298 (14) 0.006 0.087 22.622 (11) 1.04711 (49) 1.408 (15)
17.05313 (41) 28.1240 (28) 0.010 0.088 26.617 (10) 1.16355 (44) 1.507 (15)
16.55110 (39) 30.499 (22) 0.071 0.113 28.939 (24) 1.2278 (10) 1.561 (15)
16.04910 (36) 33.1993 (81) 0.024 0.090 31.582 (12) 1.29929 (49) 1.618 (14)
15.54701 (34) 36.2281 (66) 0.018 0.089 34.551 (10) 1.37697 (41) 1.677 (13)
15.04497 (33) 39.659 (12) 0.030 0.092 37.918 (14) 1.46237 (53) 1.741 (12)
14.84420 (32) 41.164 (19) 0.046 0.098 39.396 (20) 1.49911 (76) 1.767 (12)
14.64342 (31) 42.755 (11) 0.025 0.090 40.960 (12) 1.53753 (46) 1.794 (11)
14.44257 (31) 44.3646 (80) 0.018 0.089 42.5425 (98) 1.57503 (36) 1.822 (10)
14.24172 (30) 46.135 (16) 0.035 0.094 44.284 (17) 1.61670 (62) 1.8516 (95)
14.04092 (30) 47.954 (12) 0.026 0.091 46.074 (13) 1.65834 (47) 1.8797 (86)
13.84015 (30) 49.9145 (96) 0.019 0.089 48.005 (10) 1.70313 (37) 1.9096 (77)
13.63934 (29) 51.919 (17) 0.032 0.093 49.979 (17) 1.74743 (59) 1.9401 (67)
13.43850 (29) 54.074 (10) 0.019 0.089 52.102 (11) 1.79485 (37) 1.9715 (55)
13.23773 (29) 56.285 (84) 0.149 0.172 54.281 (84) 1.8420 (28) 2.0036 (42)
13.03687 (29) 58.743 (16) 0.027 0.091 56.707 (16) 1.89509 (54) 2.0365 (28)
12.83611 (29) 61.291 (28) 0.045 0.098 59.221 (28) 1.94864 (91) 2.0701 (11)
12.63525 (29) 64.020 (24) 0.037 0.094 61.916 (24) 2.00543 (76) 2.10460 (63)
12.43446 (29) 66.873 (20) 0.030 0.092 64.733 (20) 2.06338 (65) 2.1400 (25)
12.23364 (29) 69.933 (20) 0.029 0.092 67.756 (21) 2.12485 (64) 2.1766 (44)
12.03285 (29) 73.152 (20) 0.027 0.091 70.938 (20) 2.18812 (61) 2.2141 (64)
11.88227 (29) 75.687 (23) 0.030 0.092 73.444 (23) 2.23709 (70) 2.2430 (79)
11.73163 (30) 78.409 (24) 0.031 0.092 76.136 (25) 2.28969 (74) 2.2725 (95)
11.58104 (30) 81.158 (25) 0.031 0.092 78.856 (26) 2.34102 (76) 2.303 (11)
11.43044 (30) 84.149 (36) 0.042 0.097 81.815 (36) 2.3973 (11) 2.333 (13)
11.27979 (31) 87.181 (24) 0.027 0.091 84.817 (25) 2.45250 (71) 2.365 (15)
11.12919 (31) 90.540 (46) 0.051 0.101 88.143 (46) 2.5147 (13) 2.397 (17)
10.97859 (31) 93.897 (22) 0.023 0.090 91.467 (23) 2.57418 (65) 2.429 (19)
10.82801 (32) 97.485 (41) 0.042 0.097 95.022 (42) 2.6375 (12) 2.463 (21)
10.67736 (32) 101.250 (25) 0.025 0.091 98.753 (27) 2.70296 (74) 2.497 (24)
10.52679 (33) 105.358 (21) 0.020 0.089 102.827 (23) 2.77478 (63) 2.532 (26)
10.37618 (33) 109.663 (39) 0.036 0.094 107.096 (41) 2.8486 (11) 2.568 (28)
10.22556 (34) 114.133 (15) 0.013 0.088 111.529 (19) 2.92348 (50) 2.604 (31)
10.07496 (35) 118.853 (37) 0.031 0.092 116.211 (39) 3.0014 (10) 2.642 (33)
9.92435 (35) 123.792 (21) 0.017 0.089 121.112 (25) 3.08118 (63) 2.681 (36)
9.77371 (36) 129.140 (42) 0.032 0.093 126.420 (44) 3.1674 (11) 2.720 (38)
9.62312 (36) 134.677 (08) 0.006 0.087 131.916 (17) 3.25420 (41) 2.761 (41)
9.47253 (37) 140.651 (58) 0.041 0.096 137.850 (60) 3.3474 (15) 2.802 (43)
9.32192 (38) 146.798 (32) 0.021 0.090 143.954 (36) 3.44001 (85) 2.844 (46)
9.17131 (38) 153.554 (64) 0.041 0.096 150.667 (66) 3.5423 (15) 2.888 (49)
9.02069 (39) 160.660 (32) 0.020 0.089 157.727 (37) 3.64736 (85) 2.932 (52)
8.92029 (40) 165.237 (96) 0.058 0.105 162.275 (98) 3.7107 (22) 2.963 (54)
8.81988 (40) 170.545 (23) 0.013 0.088 167.552 (30) 3.78828 (67) 2.994 (56)
8.71947 (41) 175.848 (58) 0.033 0.093 172.822 (61) 3.8630 (14) 3.025 (58)
8.61909 (41) 181.513 (18) 0.010 0.088 178.455 (27) 3.94296 (60) 3.057 (60)
8.51867 (42) 187.243 (68) 0.037 0.094 184.153 (71) 4.0215 (16) 3.090 (62)
8.41826 (42) 193.382 (24) 0.012 0.088 190.259 (31) 4.10582 (67) 3.123 (64)
8.31785 (43) 199.733 (76) 0.038 0.095 196.576 (79) 4.1916 (17) 3.157 (66)
8.21747 (43) 206.406 (13) 0.006 0.087 203.214 (25) 4.28080 (52) 3.192 (68)
8.11704 (44) 213.266 (69) 0.032 0.093 210.039 (73) 4.3705 (15) 3.227 (70)
8.01663 (44) 220.693 (33) 0.015 0.088 217.430 (40) 4.46835 (82) 3.263 (72)
8.00711 (44) 221.235 (56) 0.025 0.091 217.969 (60) 4.4741 (12) 3.266 (72)
7.91623 (45) 228.262 (21) 0.009 0.088 224.963 (31) 4.56525 (63) 3.299 (74)
7.81584 (45) 236.089 (35) 0.015 0.088 232.752 (42) 4.66342 (84) 3.336 (76)
7.71542 (46) 244.576 (56) 0.023 0.090 241.202 (61) 4.7706 (12) 3.374 (78)
7.61504 (46) 253.292 (29) 0.012 0.088 249.879 (38) 4.87796 (73) 3.413 (80)
7.51462 (47) 262.520 (80) 0.031 0.092 259.068 (84) 4.9907 (16) 3.452 (82)
7.41422 (47) 271.873 (18) 0.006 0.087 268.381 (30) 5.10099 (57) 3.492 (84)
7.31381 (48) 282.11 (11) 0.040 0.096 278.57 (12) 5.2230 (22) 3.533 (86)
7.21342 (48) 292.731 (69) 0.024 0.090 289.156 (74) 5.3470 (14) 3.575 (88)
7.11301 (49) 304.17 (19) 0.065 0.108 300.55 (20) 5.4804 (36) 3.617 (90)
7.01258 (50) 316.101 (95) 0.030 0.092 312.440 (98) 5.6167 (18) 3.661 (92)
6.91218 (50) 328.37 (12) 0.036 0.094 324.67 (12) 5.7530 (22) 3.705 (94)
6.81178 (51) 341.17 (29) 0.084 0.121 337.42 (29) 5.8921 (50) 3.750 (96)
6.71138 (51) 354.71 (26) 0.072 0.113 350.91 (26) 6.0374 (44) 3.796 (98)
6.61096 (52) 368.63 (37) 0.101 0.134 364.79 (38) 6.1823 (64) 3.84 (10)
6.51058 (52) 383.96 (36) 0.095 0.129 380.07 (37) 6.3434 (61) 3.89 (10)
6.41016 (53) 400.29 (46) 0.114 0.143 396.34 (46) 6.5130 (75) 3.94 (10)
6.30977 (54) 416.86 (47) 0.112 0.142 412.87 (47) 6.6784 (76) 3.99 (11)
6.20935 (54) 434.79 (58) 0.133 0.159 430.75 (58) 6.8568 (92) 4.04 (11)
6.10894 (55) 454.13 (69) 0.151 0.174 450.04 (69) 7.047 (11) 4.09 (11)
6.00853 (55) 474.92 (59) 0.124 0.151 470.78 (59) 7.2515 (91) 4.14 (11)
5.90815 (56) 496.93 (97) 0.195 0.214 492.73 (97) 7.463 (15) 4.20 (11)
5.80774 (57) 518.90 (95) 0.183 0.203 514.64 (95) 7.662 (14) 4.25 (11)
5.70733 (57) 545 (1) 0.199 0.217 540 (1) 7.904 (16) 4.31 (11)
5.60692 (58) 569 (1) 0.194 0.212 565 (1) 8.120 (16) 4.37 (11)
5.50652 (58) 595 (1) 0.215 0.232 591 (1) 8.339 (18) 4.43 (11)
5.40611 (59) 623 (1) 0.175 0.196 618 (1) 8.566 (15) 4.49 (11)
5.30571 (60) 654 (1) 0.207 0.225 649 (1) 8.831 (18) 4.55 (12)
5.20530 (60) 687 (2) 0.273 0.286 682 (2) 9.107 (25) 4.61 (12)
5.10490 (61) 722 (3) 0.420 0.428 717 (3) 9.387 (40) 4.67 (12)
5.00449 (61) 746 (9) 1.217 1.220 741 (9) 9.50 (12) 4.73 (12)

The obtained mass attenuation coefficients using the integrated column densities [ρt]c by central-foil mapping have been found to be consistent with the full-foil mapping to within 0.15%. A summary of uncertainty and error contributions is presented in Table 3[link].

Table 3
Error contributions from variance and experimental systematics to 5.1 keV

Quantity Estimated errors Uncertainty contributions
[μ/ρ] 0.005–0.181% Relative uncertainty from variance
  0.0025% Fluorescence scattering
  0.001–0.002% Harmonic contaminations
  0.01–0.4% Weighted average of multiple samples at the same energy and roughness
[μ/ρ][ρt]c 0.048% Integrated column density determination and X-ray raster scan
E 0.3–0.6 eV Energy calibration

5.2. Derivation of photoelectric absorption, form factor and scattering components

Theoretically tabulated (FFAST and XCOM) scattering cross sections [[{{\mu}/{\rho}}]_{\rm R+C}] were derived (by interpolation) for the measured experimental energies at which X-ray mass attenuation coefficients were determined. The photoelectric mass absorption coefficient [[{{\mu}/{\rho}}]_{\rm pe}] was then determined by subtracting the theoretically tabulated scattering cross sections [[{{\mu}/{\rho}}]_{\rm R+C}] from the measured total mass attenuation coefficients [[{{\mu}/{\rho}}]] (Tran et al., 2004[Tran, C. Q., de Jonge, M. D., Barnea, Z. & Chantler, C. T. (2004). J. Phys. B, 37, 3163-3176.]). In this analysis, we used [[{{\mu}/{\rho}}]_{\rm R+C}] averaging the XCOM (Berger et al., 1998[Berger, M. J., Hubbell, J. H., Seltzer, S. M., Chang, J., Coursey, J. S., Sukumar, R. & Zucker, D. S. (1998). NIST Stand. Ref. Database, 8, 87-3597.]; Saloman et al., 1988[Saloman, E. B., Hubbell, J. H. & Scofield, J. H. (1988). At. Data Nucl. Data Tables, 38, 1.]) and FFAST (Chantler, 1995[Chantler, C. T. (1995). J. Phys. Chem. Ref. Data, 24, 71-82.], 2000[Chantler, C. T. (2000). J. Phys. Chem. Ref. Data, 29, 597-1048.]) tabulated values. The corresponding uncertainty of [[{{\mu}/{\rho}}]_{\rm pe}] was determined from the half of the variation between the two tabulations. The imaginary component of the atomic form factor [f^{\,\prime\prime}] is directly related to the photoelectric absorption,

[f^{\,\prime\prime} = {{EuA{[{\mu}/{\rho}]_{\rm pe}}} \over {2hcr_{\rm e}}},\eqno(9)]

where E is the photon energy in eV, u is the atomic mass unit, A is the relative atomic mass of silver, h is the Planck constant, c is the speed of light and re is the classical electron radius. The corresponding uncertainty in [f^{\,\prime\prime}] was evaluated using

[\sigma_{f^{\,\prime\prime}} = {{EuA} \over {2hcr_{\rm e}}}\left(\sigma^2_{[{{\mu}/{\rho}}]}+\Delta^2_{\rm RC}\right)^{{{1}/{2}}}.\eqno(10)]

5.3. Independent verification of potential accuracy of XERT

Comparison of results reported here with an earlier data set optimized for higher energies (Tran et al., 2005[Tran, C. Q., Chantler, C. T., Barnea, Z., de Jonge, M. D., Dhal, B. B., Chung, C. T. Y., Paterson, D. & Wang, J. (2005). J. Phys. B, 38, 89-107.]) confirms agreement to within one standard error of each data set collected and analysed using the principles of the XERT, in the region over which they overlap. These results (Figs. 12[link] and 13[link]) show excellent agreement with the careful earlier work (Tran et al., 2005[Tran, C. Q., Chantler, C. T., Barnea, Z., de Jonge, M. D., Dhal, B. B., Chung, C. T. Y., Paterson, D. & Wang, J. (2005). J. Phys. B, 38, 89-107.]) collected under independent conditions, with agreement to within one standard error across the range 16 keV to 20 keV, with a standard error of about 0.1%.

The earlier work reported accuracies between 0.27% and 0.4% away from the K-edge from measurements at the Advanced Photon Source, Chicago, 1BM, using a silicon 400 monochromating diffracting crystal, 2 mm × 2 mm aperture and N2 in ion chambers. The current data were collected at beamline 20B of the Photon Factory in Tsukuba, Japan. The X-ray beam was monochromated by a double-crystal monochromator using a monolithic silicon 111 crystal located in the first optical enclosure. The monochromated X-rays were passed through a pair of orthogonal adjustable slits for defining the beam cross section (approximately 2 mm × 1.5 mm). Harmonics, collimation, monochromatic and energy range were different in the two experiments. The sample stage location was also different, implying that systematic corrections including scattering were also of a different magnitude. While some of the foils used as samples were the same, the principle foil thicknesses used in the experiment were different. Even when the same foils were used, the points on the foil through which the X-ray beam passed were not the same.

Interestingly, both experiments used powder diffraction to calibrate the energies of the measured attenuations; but whereas the earlier experiment used a single Si 640b standard powder on a scanning six-circle goniometer, the current experiment used the powder in an image-plate environment using BigDiff, the large Australian powder diffractometer. The systematics for each of these differences are independent and the agreement from such different beamlines and arrangements is therefore quite remarkable.

The key marker for the self-consistency of the data after removal of systematic contributions is Fig. 10 of the earlier publication compared with Fig. 11[link] of this current paper. The consistencies are very similar, and it is not clear which results are superior on that basis. In the tables, the earlier experiment separated the statistical precision from the absolute measurement, and noted that the dominant systematic was the absolute calibration of the foils, with the second most dominant being the statistical precision, especially at the high energies involved.

Conversely, in the current experiment, the precision is generally improved, and the relative accuracy is generally improved; a significant uncertainty arises from the absolute calibration of the primary foil, and a significant uncertainty arises from the variance between measurements of different foils, including the accuracy of the transfer of thickness determination from primary foils to secondary foils (at higher energies). The fact that so many variables were so different and yet the overall technique generated accurate and consistent results in the region of overlap, at the extremes of energy of both data sets, is perhaps the greatest achievement of the X-ray extended range technique.

6. Conclusion

The X-ray mass attenuation coefficients of silver were determined with an accuracy of 0.01–0.2% on a relative scale down to 5.3 keV, and of 0.09–1.22% on an absolute scale to 5.0 keV. This analysis provides the most accurate measured X-ray mass attenuation coefficients of silver in the 5–20 keV energy range. The methodology developed in this analysis will be important for the XAFS investigation of the L and K edges of silver.

One of the key achievements from this analysis is the attainment of high accuracy at lower energies (lower than 10 keV) for such a high-Z element. This analysis indicates that high accuracy is obtainable at lower energies by the use of comparatively thin foils (5 µm) and by the use of dilute solutions of silver compounds if accurate transfer is possible. This work thus indicates that measurements of L-edge XAFS of silver (theoretically at 3.8 keV) are possible using XERT by making use of thinner silver foils at lower energies (3–6 keV).

Perhaps just as significant is the independent verification of the accuracy of the earlier work of Tran et al. (2005[Tran, C. Q., Chantler, C. T., Barnea, Z., de Jonge, M. D., Dhal, B. B., Chung, C. T. Y., Paterson, D. & Wang, J. (2005). J. Phys. B, 38, 89-107.]) to within one standard error, which confirms the potential accuracy of this technique and the portability with different diffracting monochromator crystals, energy ranges and foils.

Acknowledgements

The Australian Research Council (ARC) and the science faculty of the University of Melbourne are acknowledged for funding this work. The authors would like to thank the staff of the Australian National Beamline Facility (ANBF), Tsukuba, Japan, where the experiment was performed for their assistance in this work. As the ANBF is now closed, we dedicate this work to the efforts of the Australian and Japanese scientists who have worked together to make the beamline and collaboration such a success.

References

First citationBarnea, Z. & Mohyla, J. (1974). J. Appl. Cryst. 7, 298–299.  CrossRef IUCr Journals Web of Science Google Scholar
First citationBerger, M. J., Hubbell, J. H., Seltzer, S. M., Chang, J., Coursey, J. S., Sukumar, R. & Zucker, D. S. (1998). NIST Stand. Ref. Database, 8, 87–3597.  Google Scholar
First citationChantler, C. T. (1995). J. Phys. Chem. Ref. Data, 24, 71–82.  CrossRef CAS Google Scholar
First citationChantler, C. T. (2000). J. Phys. Chem. Ref. Data, 29, 597–1048.  Web of Science CrossRef CAS Google Scholar
First citationChantler, C. T. (2009). Eur. Phys. J. 169, 147–153.  Google Scholar
First citationChantler, C. T., Rae, N. A., Islam, M. T., Best, S. P., Yeo, J., Smale, L. F., Hester, J., Mohammadi, N. & Wang, F. (2012). J. Synchrotron Rad. 19, 145–158.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationChantler, C. T., Tran, C. Q., Paterson, D. & Barnea, Z. (2001). Phys. Lett. A, 286, 338–346.  Web of Science CrossRef CAS Google Scholar
First citationGerward, L. (1989). Acta Cryst. A45, 1–3.  CrossRef CAS Web of Science IUCr Journals Google Scholar
First citationGerward, L., Thuesen, G., Stibius Jensen, M. & Alstrup, I. (1979). Acta Cryst. A35, 852–857.  CrossRef CAS IUCr Journals Web of Science Google Scholar
First citationGlover, J. L. & Chantler, C. T. (2007). Meas. Sci. Technol. 18, 2916–2920.  Web of Science CrossRef CAS Google Scholar
First citationGlover, J. L., Chantler, C. T., Barnea, Z., Rae, N. A., Creagh, D. C., Paterson, D. & Dhal, B. B. (2008). Phys. Rev. A, 78, 052902.  Web of Science CrossRef Google Scholar
First citationGlover, J. L., Chantler, C. T., Barnea, Z., Rae, N. A. & Tran, C. Q. (2010). J. Phys. B, 43, 085001.  Web of Science CrossRef Google Scholar
First citationGlover, J. L., Chantler, C. T. & de Jonge, M. D. (2009). Phys. Lett. A, 373, 1177–1180.  Web of Science CrossRef CAS Google Scholar
First citationHan, S. W., Stern, E. A., Haskel, D. & Moodenbaugh, A. R. (2002). Phys. Rev. B, 66, 094101.  Web of Science CrossRef Google Scholar
First citationHopersky, A. N., Petrov, I. D., Nadolinsky, A. M., Yavna, V. A. & Koneev, R. V. (2004). J. Phys. B, 37, 3313–3320.  Web of Science CrossRef CAS Google Scholar
First citationHossain, F., Riley, D. & Murch, G. (2005). Phys. Rev. B, 72, 235101.  Web of Science CrossRef Google Scholar
First citationIgnatov, A., Yu, Ali, N. & Khalid, S. (2001). Phys. Rev. B, 64, 014413.  Web of Science CrossRef Google Scholar
First citationIslam, M. T., Rae, N. A., Glover, J. L., Barnea, Z., de Jonge, M. D., Tran, C. Q., Wang, J. & Chantler, C. T. (2010). Phys. Rev. A, 81, 022903.  Web of Science CrossRef Google Scholar
First citationJoly, Y. (2001). J. Phys. B, 63, 125120.  Google Scholar
First citationJonge, M. D. de, Barnea, Z., Tran, C. Q. & Chantler, C. T. (2004a). Phys. Rev. A, 69, 022717.  Google Scholar
First citationJonge, M. D. de, Tran, C. Q., Chantler, C. T. & Barnea, Z. (2006). Opt. Eng. 45, 046501.  Google Scholar
First citationJonge, M. D. de, Tran, C. Q., Chantler, C. T., Barnea, Z., Dhal, B. B., Cookson, D. J., Lee, W. K. & Mashayekhi, A. (2004b). Meas. Sci. Technol. 15, 1811–1822.  Web of Science CrossRef Google Scholar
First citationJonge, M. D. de, Tran, C. Q., Chantler, C. T., Barnea, Z., Dhal, B. B., Cookson, D. J., Lee, W. K. & Mashayekhi, A. (2005). Phys. Rev. A, 71, 032702.  Google Scholar
First citationKarabulut, A., Gurol, A., Budak, G. & Ertugrul, M. (2005). Nucl. Instrum. Methods Phys. Res. B, 227, 485–489.  Web of Science CrossRef CAS Google Scholar
First citationKhoperskii, A., Nadolinskii, A., Yavna, V. & Koneev, R. (2005). Opt. Spectrosc. 98, 161–165.  Web of Science CrossRef CAS Google Scholar
First citationLee, M. J., Hahn, P. F., Papanicolaou, N., Egglin, T. K., Saini, P. R., Mueller, S. & Simeone, J. F. (1991). Radiology, 179, 415–418.  CrossRef CAS PubMed Web of Science Google Scholar
First citationLytle, F. (2007). Synchrotron Radiat. News, 20, 9.  CrossRef Google Scholar
First citationMachali, F., Al-Barakati, G. G., El-Sayed, A. A. & Altaf, W. J. (1987). J. Phys. F, 17, 1279–1284.  CrossRef CAS Web of Science Google Scholar
First citationMica, J. F., Martin, L. J. & Barnea, Z. (1985). J. Phys. C, 18, 5215–5223.  Google Scholar
First citationPettifer, R. F., Borowski, M. & Loeffen, P. W. (1999). J. Synchrotron Rad. 6, 217–219.  Web of Science CrossRef CAS IUCr Journals Google Scholar
First citationRae, N. A., Chantler, C. T., Barnea, Z., de Jonge, M. D., Tran, C. Q. & Hester, J. R. (2010). Phys. Rev. A, 81, 022904.  Web of Science CrossRef Google Scholar
First citationRae, N. A., Chantler, C. T., Tran, C. Q. & Barnea, Z. (2006). Radiat. Phys. Chem. 75, 2063–2066.  Web of Science CrossRef CAS Google Scholar
First citationRehr, J. & Albers, R. (2000). Rev. Mod. Phys. 72, 621–654.  Web of Science CrossRef CAS Google Scholar
First citationSaloman, E. B., Hubbell, J. H. & Scofield, J. H. (1988). At. Data Nucl. Data Tables, 38, 1.  CrossRef Web of Science Google Scholar
First citationSandiago, T. K. U. & Gowa, R. (1997). Pramana, 48, 1077.  CrossRef Web of Science Google Scholar
First citationTajuddin, A. A., Chong, C., Shukri, A., Bandyopadhyay, T. & Bradley, A. (1995). Appl. Radiat. Isot. 46, 113–115.  CrossRef CAS Web of Science Google Scholar
First citationTantau, L. J., Islam, M. T., Payne, A. T., Tran, C. Q., Cheah, M. H., Best, S. P. & Chantler, C. T. (2013). Radiat. Phys. Chem. In the press.  Google Scholar
First citationTran, C. Q., Barnea, Z., de Jonge, M. D., Dhal, B. B., Paterson, D., Cookson, D. J. & Chantler, C. T. (2003a). X-ray Spectrom. 32, 69–74.  Web of Science CrossRef CAS Google Scholar
First citationTran, C. Q., Chantler, C. T. & Barnea, Z. (2003b). Phys. Rev. Lett. 90, 257401.  Web of Science CrossRef PubMed Google Scholar
First citationTran, C. Q., Chantler, C. T., Barnea, Z., de Jonge, M. D., Dhal, B. B., Chung, C. T. Y., Paterson, D. & Wang, J. (2005). J. Phys. B, 38, 89–107.  Web of Science CrossRef CAS Google Scholar
First citationTran, C. Q., Chantler, C. T., Barnea, Z., Paterson, D., Cookson, D. J. & Balaic, D. X. (2003c). Phys. Rev. A, 67, 042716.  Web of Science CrossRef Google Scholar
First citationTran, C. Q., de Jonge, M. D., Barnea, Z. & Chantler, C. T. (2004). J. Phys. B, 37, 3163–3176.  Web of Science CrossRef CAS Google Scholar

© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds