short communications
Energy optimization of a regular macromolecular crystallography beamline for ultra-high-resolution crystallography
aStructural Biology Center, Biosciences Division, Argonne National Laboratory, Argonne, IL 60439, USA, bDepartment of Biochemistry and Molecular Biology, The University of Georgia, Athens, GA 30602, USA, cDepartment of Chemistry, The University of Toledo, Toledo, OH 43606, USA, and dBioscience Division, Protein Crystallography Station, Lujan Neutron Scattering Center, Los Alamos National Laboratory, Los Alamos, NM 87545, USA
*Correspondence e-mail: chen_j@lanl.gov
A practical method for operating existing undulator synchrotron beamlines at photon energies considerably higher than their standard operating range is described and applied at beamline 19-ID of the Structural Biology Center at the Advanced Photon Source enabling operation at 30 keV. Adjustments to the undulator spectrum were critical to enhance the 30 keV
while reducing the lower- and higher-energy harmonic contamination. A Pd-coated mirror and Al attenuators acted as effective low- and high-bandpass filters. The resulting at 30 keV, although significantly lower than with X-ray optics designed and optimized for this energy, allowed for accurate data collection on crystals of the small protein crambin to 0.38 Å resolution.Keywords: undulator; high energy; monochromator; harmonic.
1. Introduction
Collection of diffraction data at high photon energies (>25 keV) has numerous useful applications, among them obtaining ultra-high-resolution data on macromolecules, polycrystalline and amorphous materials, and structural investigations on small molecules. In particular, ultra-high-resolution data on macromolecular crystals can yield more accurate structures, reveal limited hydrogen atom positions, extract information about motions of atoms and macromolecules, and enable charge density analysis of structures. To date, nearly 600 structures in the Protein Data Bank have been solved at higher than 1.0 Å, with 47 structures resolved beyond 0.8 Å. These structures contain valuable information about bond lengths and angles, hydrogen atom positions, and therefore reveal great detail about the chemistry within protein structures and especially enzyme active sites. However, beamline operation at high energies and collection of ultra-high-resolution diffraction data remain challenging, and can involve major hardware adjustments. Beamline 19-ID at the Advanced Photon Source (APS) is an undulator beamline equipped with a Si(111) monochromator, a vertically focusing mirror with three lanes (Pd-coated, uncoated and Pt-coated), an array of Al and Ag filters for attenuation, and an ADSC Quantum 315r CCD detector (Rosenbaum et al., 2006). The standard operational energy range is 6.5–13.5 keV, extendable with some special effort to 19.5 keV. This report describes a method of utilizing undulator, monochromator, mirror and attenuator settings to operate 19-ID at 30 keV (0.413 Å) that may be applicable to similar stations at other synchrotrons.
2. Results and discussion
There are two general options for collecting ultra-high-resolution data. One option involves moving the detector into a position suitable for collecting high-angle reflections. At 19-ID, available θ adjustment and crystal-to-detector distance. Adjustment of offset offers little gain in maximum resolution, and the 2θ adjustment leads to loss of reciprocal-space sampling, a variety of spot shapes, high background and problems with data-processing program suites. A close crystal-to-detector distance results in significant shadowing from the goniostat and extreme elongation of spots at the edge of the detector. Another option to address many of the aforementioned problems is to operate the beamline at a higher energy setting resulting in the compression of the diffraction pattern on the detector. The majority of macromolecular crystallography (MX) beamlines use Si(111) as a monochromator crystal and have an operational short wavelength limit of ≥0.75 Å (16 keV). With some effort it is mostly possible to extend the energy range up to ∼20 keV. A photon energy of 21 keV was used to collect 0.55 Å data on Z-DNA crystals (Brzezinski et al., 2011), and similar high-energy settings (25 keV) were used to collect 0.48 Å data on crystals of crambin (Schmidt et al., 2011). To achieve a target resolution of 0.4 Å at 16 keV would require 2θ = 140°. Even at 19.5 keV the scattering angle would be 105°. As MX beamline end-stations are not set up for these scattering angles, it is necessary to go to higher energy, i.e. shorter-wavelength settings to collect ultra-high-resolution reflections in an efficient and accurate manner. To efficiently use the detector area and avoid excessive spot elongation the maximum scattering angle should be 2θ ≤ 60°, leading to a general metric where the wavelength of radiation used is equal to the desired highest resolution. In order to obtain 0.4 Å resolution data at 2θ = 60° one would need λ = dmin = 0.4 Å (31 keV). The detector should also be placed in a position to avoid shadowing from the goniometer head and other beamline components, and to avoid unusual effects at high energy, such as beam stop fluorescence.
of the detector include vertical offset, 2Out of the ∼150 biological beamlines at synchrotrons worldwide (https://biosync.sbkb.org), only four MX end-stations are rated for standard operation at 30 keV or higher energy, with none currently operational in North America. Since the design of the monochromator at 19-ID does not allow operation at 30 keV with Si(111), one possibility is to replace the monochromator crystal with a higher-index cut, e.g. Si(311) or Si(400). This is impractical as it involves a multi-day procedure of warming up the liquid-nitrogen-cooled monochromator, replacing the crystals, cooling the monochromator and re-calibration of the system. A more practical option is to use a higher-index reflection of the existing monochromator crystal, allowing for operation of the beamline in the normal Bragg-angle range. For example, using the Si(333) reflection provides a 30 keV output beam at the same Bragg-angle setting as for 10 keV from the Si(111) reflection. The major disadvantage of this is lower intensity: the bandwidth of Si(333) is 0.065 relative to Si(111), 0.32 relative to Si(311) and 0.36 relative to Si(400). Another disadvantage of using Si(333) is the presence of contaminating energies at 10 keV Si(111), 40 keV Si(444) and 50 keV Si(555), whereas Si(311) or Si(400) would have a single contaminating energy at 90 keV or 60 keV, respectively, both well separated from 30 keV and, thus, more effectively rejected by a mirror.
The strongest and potentially most serious contamination is the 10 keV sub-harmonic (Tables 1 and 2). If the diffraction pattern is recorded with a photon-counting pixel array detector, 10 keV photons are not counted. However, for integrating detectors, like CCD detectors, strong low-order h,k,l-peaks from 10 keV photons are integrated by the same pixels as the weaker 3h,3k,3l-peaks from 30 keV photons. The relative contribution of the 10 keV signal on the CCD is magnified by two factors. The integrated intensity of the diffraction peaks is proportional to λ2 and the primary of the scintillator in front of the CCD is only ∼15% at 30 keV compared with 94% at 10 keV. Thus, even with the three-times-higher light output per absorbed 30 keV photon the average signal per incident photon is higher for 10 keV photons than for 30 keV photons. The resulting strength, recorded by a CCD detector, of diffraction peaks arising from the contamination relative to the 30 keV component is listed in Table 3. Considering the ∼λ3 dependence of the the 10 keV on the sample should be <1/90 of the 30 keV in order to keep the 10 keV dose at <1/10 of the 30 keV dose.
|
|
|
The undulator X-ray source offers the unique ability to manipulate the a, Table 1). A more favorable is achieved by moving the fourth harmonic to 30 keV, reducing the 10 keV sub-harmonic by three orders of magnitude relative to the 30 keV while the 40 and 50 keV harmonics are about the same or reduced (Fig. 1b, Table 2). The even undulator harmonics are labeled as weak, although this is only true for the on-axis beam (see supporting information1). The intensity into the central cone is quite strong (Table 1). The even-harmonics maxima are also wider than those for the odd harmonics which gives more freedom to optimize the ratios of the contaminations to the 30 keV radiation without going too much off the maximum flux.
by changing the gap between the magnets. Normally, a gap is set so that one of the peaks of the is at the desired photon energy. In this case, the aim is to find a gap setting that minimizes contamination at 10, 40 and 50 keV relative to the intensity at 30 keV. The standard approach would be to set the undulator gap for the third or fifth harmonic at 30 keV; however, both emission spectra show a significant contamination of 10, 40 and 50 keV harmonics (Fig. 1Reduction of the higher harmonics intensities relative to the 30 keV ) show that, given the choice of Pd or Pt as the mirror coating, Pd gives the best ratio of 30 keV versus 40 keV reflectivity (Fig. 2). The calculations also suggest a grazing angle of about 2.0 mrad as the best balance between reasonable reflectivity at 30 keV and good rejection of 40 and 50 keV. The actual best mirror angle has to be determined experimentally since the actual density of the vapor-deposited surface coating is different from the bulk metal density and is not exactly known.
is achieved by careful setting of the grazing angle and selection of the surface coated lane of the vertical focusing mirror. Calculations of the reflectivity for 30, 40 and 50 keV radiation (Stepanov, undatedReduction of the strong 10 keV contamination is easily achieved with absorption filters. Aluminium, pure or common alloys, are suitable choices since there are no absorption edges between 10 keV and 30 keV and the ratio of the absorption coefficients is high. Al filters with attenuations at 10 keV between 30 (0.5 mm) and 104 (1.5 mm) are readily available from the filter array at most beamlines. Absorption filters will enhance the of the higher harmonics relative to 30 keV. Therefore, the attenuation factor should be kept at the minimum necessary for 10 keV reduction. To estimate the 10 keV contamination of the beam incident on the sample, a series of Al filters of increasing thickness were inserted and the transmitted measured with an ion chamber. By analyzing the decay versus filter thickness and accounting for the absorption coefficients of the filter material and the ion chamber gas (N2), an estimate of the ratio of 10 keV to 30 keV fluxes can be obtained. The higher energy contaminations are too small to be estimated by this method, but they are of less concern. Knowing the 10 keV contamination of the incident beam is only a first step. Most important is the detector signal of diffraction peaks attributable to 10 keV photons, relative to those attributable to 30 keV photons. An initial estimate of the detector signal of the 10 keV component can be obtained using the uncoated lane of the mirror surface, which does not reflect 30 keV photons, and recording diffraction images without and with filters. Then, after returning the mirror to the Pd lane that reflects the 30 keV the filter thickness should be gradually increased until, estimating from the decrease of the diffraction signal on the detector with increasing filter thickness, the remaining 10 keV contribution is small enough that it can be estimated well enough for correction of the diffraction data before processing. Filter thicknesses that absorb more than 30% at 30 keV (i.e. 1.3 mm Al) should be avoided because they noticeably enhance the higher harmonics.
It should be noted that accessing higher photon energies in the manner proposed here results in a greatly decreased λ2, and the low of the detector at 30 keV, the undulator emission also decreases with increasing photon energy. Fortunately, at high-energy third-generation storage rings like the APS there is enough at high photon energies to collect ultra-high-resolution data in a reasonable time despite the less-than-optimal way of accessing the very high photon energy regime.
and detector signal. In addition to the factors discussed above, such as the smaller bandwidth of the monochromator, the decrease of the integrated intensity of diffraction peaks withThe 30 keV beam was tested on crystals of the small protein crambin. Crambin forms the best-ordered macromolecular crystals known, diffracting to a published resolution of 0.48 Å (Schmidt et al., 2011). This setting enabled collection of a complete high-quality dataset at 19-ID at 10 K on a large (∼0.2 mm3) crystal, yielding data to a nominal resolution of 0.38 Å and an overall Rsym of 5.4% (Table 4). The low temperature of data collection has the advantage of decreased B-factors and background scattering, contributing to the extraordinary resolution obtained. A detailed structural is currently underway, in addition to efforts to further extend the resolution through careful data collection protocols and management of radiation damage.
|
Supporting information
Differences between even and odd harmonic profiles. DOI: https://doi.org/10.1107/S1600577514022619/cn5058sup1.pdf
Acknowledgements
The authors thank Dr Andrzej Joachimiak for helpful comments and discussions. This work was supported by US DOE-OBER, DE-AC02-06CH11357.
References
Brzezinski, K., Brzuszkiewicz, A., Dauter, M., Kubicki, M., Jaskolski, M. & Dauter, Z. (2011). Nucleic Acids Res. 39, 6238–6248. Web of Science CrossRef CAS PubMed Google Scholar
Rosenbaum, G., Alkire, R. W., Evans, G., Rotella, F. J., Lazarski, K., Zhang, R.-G., Ginell, S. L., Duke, N., Naday, I., Lazarz, J., Molitsky, M. J., Keefe, L., Gonczy, J., Rock, L., Sanishvili, R., Walsh, M. A., Westbrook, E. & Joachimiak, A. (2006). J. Synchrotron Rad. 13, 30–45. Web of Science CrossRef CAS IUCr Journals Google Scholar
Schmidt, A., Teeter, M., Weckert, E. & Lamzin, V. S. (2011). Acta Cryst. F67, 424–428. Web of Science CrossRef CAS IUCr Journals Google Scholar
Stepanov, S. (undated). X-ray Server, https://x-server.gmca.aps.anl.gov. Google Scholar
Tanaka, T. (undated). SPECTRA: a synchrotron radiation calculation code, https://radiant.harima.riken.go.jp/spectra/index.html. Google Scholar
© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.