research papers\(\def\hfill{\hskip 5em}\def\hfil{\hskip 3em}\def\eqno#1{\hfil {#1}}\)

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775

Development of variable-magnification X-ray Bragg optics

CROSSMARK_Color_square_no_text.svg

aInstitute of Materials Structure Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki 305-0801, Japan
*Correspondence e-mail: keiichi.hirano@kek.jp

Edited by A. Momose, Tohoku University, Japan (Received 23 February 2015; accepted 6 May 2015; online 25 June 2015)

A novel X-ray Bragg optics is proposed for variable-magnification of an X-ray beam. This X-ray Bragg optics is composed of two magnifiers in a crossed arrangement, and the magnification factor, M, is controlled through the azimuth angle of each magnifier. The basic properties of the X-ray optics such as the magnification factor, image transformation matrix and intrinsic acceptance angle are described based on the dynamical theory of X-ray diffraction. The feasibility of the variable-magnification X-ray Bragg optics was verified at the vertical-wiggler beamline BL-14B of the Photon Factory. For X-ray Bragg magnifiers, Si(220) crystals with an asymmetric angle of 14° were used. The magnification factor was calculated to be tunable between 0.1 and 10.0 at a wavelength of 0.112 nm. At various magnification factors (M ≥ 1.0), X-ray images of a nylon mesh were observed with an air-cooled X-ray CCD camera. Image deformation caused by the optics could be corrected by using a 2 × 2 transformation matrix and bilinear interpolation method. Not only absorption-contrast but also edge-contrast due to Fresnel diffraction was observed in the magnified images.

1. Introduction

The X-ray Bragg magnifier based on asymmetric diffraction at a nearly perfect crystal (Kohra, 1972[Kohra, K. (1972). Proceedings of the Sixth International Conference on X-ray Optics and Microscopy, edited by G. Shinoda, K. Kohra and T. Ichinokawa, pp. 35-45. University of Tokyo Press.]) is a useful optical element for X-ray radiology and microscopy, and has been used at synchrotron facilities, for example, for X-ray microtomography (µ-CT) (Stampanoni et al., 2002[Stampanoni, M., Borchert, G., Abela, R. & Rüegsegger, P. (2002). J. Appl. Phys. 92, 7630-7635.], 2003[Stampanoni, M., Borchert, G., Abela, R. & Rüegsegger, P. (2003). Appl. Phys. Lett. 82, 2922-2924.]), analyzer-based phase-contrast imaging (Modregger et al., 2006[Modregger, P., Lübbert, D., Schäfer, P. & Köhler, R. (2006). Phys. Rev. B, 74, 054107.]; Hönnicke & Cusatis, 2007[Hönnicke, M. G. & Cusatis, C. (2007). Rev. Sci. Instrum. 78, 113708.]; Hirano, 2011[Hirano, K. (2011). Jpn. J. Appl. Phys. 50, 026402.]) and inline holography (Vagovič et al., 2013[Vagovič, P., Korytár, D., Cecilia, A., Hamann, E., Švéda, L., Pelliccia, D., Härtwig, J., Zápražný, Z., Oberta, P., Dolbnya, I., Shawney, K., Fleschig, U., Fiederle, M. & Baumbach, T. (2013). J. Synchrotron Rad. 20, 153-159.], 2014[Vagovič, P., Švéda, L., Cecilia, A., Hamann, E., Pelliccia, D., Gimenez, E. N., Korytár, D., Pavlov, K. M., Zápražný, Z., Zuber, M., Koenig, T., Olbinado, M., Yashiro, W., Momose, A., Fiederle, M. & Baumbach, T. (2014). Opt. Express, 22, 21508-21520.]). One of the most striking features of the X-ray Bragg magnifier is that it can cover a wide range of resolution from submicrometer (Kobayashi et al., 2001[Kobayashi, K., Izumi, K., Kimura, H., Kimura, S., Ibuki, T., Yokoyama, Y., Tsusaka, Y., Kagoshima, Y. & Matsui, J. (2001). Appl. Phys. Lett. 78, 132-134.]; Schäfer & Köhler, 2003[Schäfer, P. & Köhler, R. (2003). J. Phys. D, 36, A113-A117.]) up to submillimeter, thus filling the gap between X-ray microscopy and radiology. Another attractive feature is that it can be combined with X-ray single-photon-counting detectors such as PILATUS (Stampanoni et al., 2005[Stampanoni, M., Borchert, G. & Abela, R. (2005). Nucl. Instrum. Methods Phys. Res. A, 551, 119-124.]) and Medipix (Vagovič et al., 2013[Vagovič, P., Korytár, D., Cecilia, A., Hamann, E., Švéda, L., Pelliccia, D., Härtwig, J., Zápražný, Z., Oberta, P., Dolbnya, I., Shawney, K., Fleschig, U., Fiederle, M. & Baumbach, T. (2013). J. Synchrotron Rad. 20, 153-159.]), opening up a new possibility for high-resolution, wide-dynamic-range, high-sensitivity and fast X-ray imaging.

In the conventional X-ray Bragg magnifier, the magnification factor is given by M = [{{\sin({{\theta_{\rm{B}}}+\alpha})}/{\sin({{\theta_{\rm{B}}}-\alpha})}}], where θB is the Bragg angle and α is the angle between the diffracting lattice planes and the crystal surface. From this equation, it can be seen that the only ways to change the magnification factor are either to change the asymmetric angle, α, by replacing the magnifier crystal, or to change the Bragg angle, θB, by changing the X-ray wavelength. In either case, tedious procedures of rearranging the optics are required. Due to this lack of flexibility in tuning the magnification factor, use of the X-ray Bragg magnifier has long been hampered. In order to solve this problem, we developed a variable-magnification X-ray Bragg magnifier by introducing a new rotation axis (the [\hat\varphi]-axis) to the conventional Bragg magnifier (Hirano et al., 2014a[Hirano, K., Takahashi, Y. & Sugiyama, H. (2014a). Nucl. Instrum. Methods Phys. Res. A, 741, 78-83.],b[Hirano, K., Takahashi, Y. & Sugiyama, H. (2014b). Jpn. J. Appl. Phys. 53, 040302.]). Thus it became feasible to locate a region-of-interest (ROI) in a sample under low magnification, and then to observe the details of the ROI under an optimized magnification. Further, our variable-magnification X-ray Bragg magnifier was successfully applied to X-ray computed tomography (CT) (Hirano et al., 2014a[Hirano, K., Takahashi, Y. & Sugiyama, H. (2014a). Nucl. Instrum. Methods Phys. Res. A, 741, 78-83.]) and analyzer-based phase-contrast imaging (Hirano et al., 2014b[Hirano, K., Takahashi, Y. & Sugiyama, H. (2014b). Jpn. J. Appl. Phys. 53, 040302.]). However, our previous studies considered only one-dimensional magnification and demagnification. In this paper, we propose a new variable-magnification X-ray Bragg optics for two-dimensional magnification.

2. Variable-magnification X-ray Bragg optics

Our variable-magnification X-ray Bragg optics consists of two magnifier crystals in a crossed arrangement as schematically shown in Fig. 1[link]. The first crystal magnifies the incident beam in the x0 direction while the second crystal does so in the y0 direction. The glancing angle of each crystal, θj, is set at the Bragg condition. Here, the subscript j is 1 for the first magnifier and 2 for the second magnifier. The [{\hat\varphi}_j] axis is perpendicular to the diffracting lattice planes of the jth crystal, and we can scan the azimuth angle, φj, keeping the Bragg condition. This kind of diffraction geometry is known as the rotated-inclined geometry (Smither & Fernandez, 1994[Smither, R. K. & Fernandez, P. B. (1994). Nucl. Instrum. Methods Phys. Res. A, 347, 313-319.]) and is used for high-heat-load monochromators at SPring-8 (Uruga et al., 1995[Uruga, T., Kimura, H., Kohmura, Y., Kuroda, M., Nagasawa, H., Ohtomo, K., Yamaoka, H., Ishikawa, T., Ueki, T., Iwasaki, H., Hashimoto, S., Kashihara, Y. & Okui, K. (1995). Rev. Sci. Instrum. 66, 2254-2256.]; Yabashi et al., 1999[Yabashi, M., Yamazaki, H., Tamasaku, K., Goto, S., Takeshita, K., Mochizuki, T., Yoneda, Y., Furukawa, Y. & Ishikawa, T. (1999). Proc. SPIE, 3773, 2-13.]). The special case of this geometry (φ = 0°) is known as the inclined geometry (Hrdý, 1992[Hrdý, J. (1992). Rev. Sci. Instrum. 63, 459-460.]; Khounsary, 1992[Khounsary, A. M. (1992). Rev. Sci. Instrum. 63, 461-464.]; Macrander et al., 1992[Macrander, A. T., Lee, W. K., Smither, R. K., Mills, D. M., Rogers, C. S. & Khounsary, A. M. (1992). Nucl. Instrum. Methods Phys. Res. A, 319, 188-196.]; Lee et al., 1992[Lee, W. K., Macrander, A. T., Mills, D. M., Rogers, C. S., Smither, R. K. & Berman, L. E. (1992). Nucl. Instrum. Methods Phys. Res. A, 320, 381-387.]; Hrdý & Pacherová, 1993[Hrdý, J. & Pacherová, O. (1993). Nucl. Instrum. Methods Phys. Res. A, 327, 605-611.]), where the magnification factor is fixed at unity. For φ = +90° (φ = −90°), we have the conventional asymmetric situation at low (high) incident angle.

[Figure 1]
Figure 1
Variable-magnification X-ray Bragg optics.

The basic properties of our optics are described by the dynamical theory of X-ray diffraction (Zachariasen, 1945[Zachariasen, W. H. (1945). Theory of X-ray Diffraction in Crystals. New York: Wiley.]; Batterman & Cole, 1964[Batterman, B. W. & Cole, H. (1964). Rev. Mod. Phys. 36, 681-717.]; Ishikawa & Kohra, 1991[Ishikawa, T. & Kohra, K. (1991). Handbook on Synchrotron Radiation, Vol. 3, edited by G. S. Brown and D. E. Moncton, pp. 63-104. Amsterdam: North-Holland.]; Authier, 2001[Authier, A. (2001). Dynamical Theory of X-ray Diffraction. Oxford University Press.]). In the rotated-inclined diffraction geometry, it is well known that the exit beam has an off-scattering-plane component (Blasdell & Macrander, 1994[Blasdell, R. C. & Macrander, A. T. (1994a). Nucl. Instrum. Methods Phys. Res. A, 347, 320-323.]; Blasdell et al., 1994[Blasdell, R. C., Macrander, A. T. & Lee, W. K. (1994b). Nucl. Instrum. Methods Phys. Res. A, 347, 327-330.]). However, since this effect is usually smaller than 0.01° in the case of an X-ray Bragg magnifier, here we ignore it for the sake of simplicity. The effective asymmetric angle, [\alpha_j^{\,\prime}], is given by [\tan\alpha_j^{\,\prime}] = [\tan\alpha_j\sin\varphi_j]; therefore, the magnification factor is given by

[\eqalignno{{M_j}\left({{\varphi_j}} \right) & = {{\sin \left({{\theta _{{\rm{B}}j}} + \alpha_j^{\,\prime}} \right)} \over {\sin \left({{\theta _{{\rm{B}}j}} - \alpha_j^{\,\prime}} \right)}} \cr& = {{\cos {\alpha _j}\sin {\theta _{{\rm{B}}j}} + \sin {\alpha _j}\cos {\theta _{{\rm{B}}j}}\sin {\varphi _j}} \over {\cos {\alpha _j}\sin {\theta _{{\rm{B}}j}} - \sin {\alpha _j}\cos {\theta _{{\rm{B}}j}}\sin {\varphi _j}}}. &(1)}]

This equation clearly shows that the magnification factor is tunable through the azimuth angle, φj. For example, Fig. 2[link] shows the calculated magnification factor. Here we set the parameters as follows: [{\theta_{{\rm{B}}1}}] = [{\theta_{{\rm{B}}2}}] = 16.96°, [{\alpha_1}] = [{\alpha_2}] = 14° and [{\varphi_1}] = [{\varphi_2}] = [\varphi]. In this case the magnification factor varies between 0.1 and 10.

[Figure 2]
Figure 2
Calculated magnification factor under the following conditions: [{\theta_{{\rm{B}}1}}] = [{\theta_{{\rm{B}}2}}] = 16.96°, [{\alpha_1}] = [{\alpha_2}] = 14° and [{\varphi_1}] = [{\varphi_2}] = [\varphi].

From the viewpoint of the geometrical optics, a point (x0, y0) on the sample plane is projected by the first magnifier to a point (x1, y1), and then by the second magnifier to a point (x2, y2) on the detector plane according to the following equations:

[\left({\matrix{ {{x_1}} \cr {{y_1}} \cr } } \right) = \left({\matrix{ { - {M_1}} & {{L_1}} \cr 0 & 1 \cr } } \right)\left({\matrix{ {{x_0}} \cr {{y_0}} \cr } } \right), \eqno(2)]

[\left({\matrix{ {{x_2}} \cr {{y_2}} \cr } } \right) = \left({\matrix{ 1 & 0 \cr { - {L_2}} & { - {M_2}} \cr } } \right)\left({\matrix{ {{x_1}} \cr {{y_1}} \cr } } \right), \eqno(3)]

where

[{L_j}\left({{\varphi_j}}\right) = \tan{\alpha_j} \cos\alpha_j^{\,\prime} {{\sin\left({2{\theta_{{\rm{B}}j}}}\right)} \over {\sin\left({{\theta_{{\rm{B}}j}}-\alpha_j^{\,\prime}}\right)}} \cos{\varphi_j}. \eqno(4)]

Combining equations (2)[link] and (3)[link] we obtain

[\left({\matrix{ {{x_2}} \cr {{y_2}} \cr } } \right) = \left({\matrix{ { - {M_1}} & {{L_1}} \cr {{L_2}{M_1}} & { - {L_1}{L_2} - {M_2}} \cr } } \right)\left({\matrix{ {{x_0}} \cr {{y_0}} \cr } } \right). \eqno(5)]

For example, let us assume that the shape of the incident beam on the sample plane is square as shown in Fig. 3(a)[link]. Fig. 3(b)[link] shows calculated beam shapes on the detector plane for various azimuth angles under the same conditions as Fig. 2[link]. It is clearly seen that, due to the non-diagonal components of the transformation matrix in equation (5)[link], the square beam is deformed by the optics to the parallelogram beam except at [{\varphi_j}] = ±90°. However, in modern X-ray imaging with the widespread use of X-ray digital area sensors such as X-ray CCD cameras and flat panel sensors, we can easily correct this image deformation using equation (5)[link]. Note that the above discussion is based on the geometrical optics; therefore, equation (5)[link] is not valid in the wave optical region.

[Figure 3]
Figure 3
Shape of the beam (a) on the sample plane and (b) on the detector plane. The calculation conditions were the same as for Fig. 2[link].

The throughput of the optics depends on the intrinsic acceptance angle of each magnifier which is given by

[{\omega_{0j}}= \sqrt{{M_j}}\,{\omega_j},\eqno(6)]

where ωj is the full width at half-maximum (FWHM) of the rocking curve of the jth magnifier for the symmetric diffraction and is given by

[{\omega_j} \approx {2 \over {\sin \left({2{\theta _{{\rm{B}}j}}} \right)}}{{{r_{\rm{e}}}{\lambda ^2}} \over {\pi {V_j}}}\left| {{C_j}} \right|\left| {{F_{hj}}} \right| ,\eqno(7)]

where re is the classical electron radius, λ is the wavelength, Vj is the volume of the unit cell, Cj is the polarization factor and Fhj is the crystal structure factor. The polarization factor, Cj, is 1 for the σ-polarization and cos(2θBj) for the π-polarization.

The intrinsic angular divergence of the outgoing beam is given by

[{\omega_{Hj}}={{{\omega_j}}\big/{\sqrt{{M_j}}}}.\eqno(8)]

Note that the intrinsic angular divergence, [{\omega_{Hj}}], is not equivalent to the actual angular divergence, [\Delta{\theta_{Hj}}], for a polychromatic source (Brauer et al., 1995a[Brauer, S., Stephenson, G. B., Mochrie, S. G. J., Dierker, S. B., Fleming, R. M., Pindak, R., Robinson, I. K., Grubel, G., Als-Nielsen, J. & Abernathy, D. L. (1995a). Rev. Sci. Instrum. 66, 1506-1509.],b[Brauer, S., Stephenson, G. B. & Sutton, M. (1995b). J. Synchrotron Rad. 2, 163-173.]). Due to the polychromatic nature of the synchrotron radiation, the beam properties such as coherence depend on [\Delta{\theta_{Hj}}]. The actual angular divergence, [\Delta{\theta_{Hj}}], can be estimated based on the DuMond diagram (DuMond, 1937[DuMond, J. W. M. (1937). Phys. Rev. 52, 872-883.]).

Because each magnifier functions independently, we can assume that the spatial resolution in the x2 direction depends on the first magnifier, while that in the y2 direction on the second one. The image blurring in each direction originates from several factors such as the so-called penumbral blurring, the diffractive blurring caused by the X-ray penetration into the magnifier, the blurring due to the detector and so on (Hirano et al., 2014a[Hirano, K., Takahashi, Y. & Sugiyama, H. (2014a). Nucl. Instrum. Methods Phys. Res. A, 741, 78-83.]).

3. Experiments and results

In order to verify the feasibility of our variable-magnification X-ray Bragg optics, we performed experiments at the vertical-wiggler beamline BL-14B of the Photon Factory. The experiments were carried out only for the magnification-case (M ≥ 1.0). At first, the white beam from the light source was monochromated at 0.112 nm by a Si(111) double-crystal monochromator. Then the monochromatic beam linearly polarized in the vertical direction was incident to the variable-magnification X-ray Bragg optics. The polarization of the incident beam corresponded to σ-polarization for the first magnifier and π-polarization for the second magnifier. For magnifiers, we used asymmetric Si(220) crystals ([{\theta_{{\rm{B}}1}}] = [{\theta_{{\rm{B}}2}}] = 16.96°, [{\alpha_1}] = [{\alpha_2}] = 14°) made of non-doped float-zone silicon crystal (ρ ≥ 2000 Ω cm). The surface of the magnifier crystals was mechanochemically polished in order to remove defects and strain fields. The intrinsic acceptance angle was calculated to be [3.6^{\,\prime\prime}\sqrt{M_1}] for the first magnifier and [3.0^{\,\prime\prime}\sqrt{M_2}] for the second magnifier. Fig. 4[link] shows a photograph of the first magnifier crystal at φ1 = 0°. The [{\hat\theta_1}] axis was in the vertical direction. The φ1 stage was mounted on the θ1-stage so that the [{\hat\varphi_1}] axis would always become perpendicular to the [{\hat\theta_1}] axis, and perpendicular to the incident beam at θ1 = 0°. A two-axis tilt stage was mounted on the φ1 stage, with which we carefully aligned the orientation of the magnifier so that the diffracting lattice planes would become perpendicular to the [{\hat\varphi _1}] axis with an accuracy of a few arcseconds. Thus we could scan the azimuth angle, φ1, without losing the Bragg diffraction. A similar instrument was also used for the second magnifier crystal. Magnified X-ray images were observed by a fiber-coupled X-ray CCD camera (Photonic Science Ltd, X-ray Coolview FDI 40mm) consisting of a GdO2S:Tb scintillator, a 3.43:1.00 glass fiber plate and a CCD. At the scintillator, X-rays were converted to visible light, which was transmitted through the glass fiber plate and detected by the CCD. The effective pixel size was 23 µm (H) × 23 µm (V) and the number of pixels was 1384 (H) × 1032 (V).

[Figure 4]
Figure 4
Photograph of the first magnifier crystal at φ1 = 0°.

At first we estimated the spatial resolution of the optics at several magnification factors using MTF charts. The results were almost the same as the previous results obtained for the one-dimensional magnification optics (Hirano et al., 2014a[Hirano, K., Takahashi, Y. & Sugiyama, H. (2014a). Nucl. Instrum. Methods Phys. Res. A, 741, 78-83.]). The main determining factors of the spatial resolution were the effective pixel size of the X-ray CCD camera and the penumbral blurring. The penumbral blurring is given by [\Delta{x_p}] [\approx] sDss/Dsd, where s is the source size, Dss is the distance between the light source and the sample and Dsd is that between the sample and the detector. In our experiments, Dss was about 20 m and Dsd was about 1.2 m. The spatial resolution in the vertical direction was slightly better than that in the horizontal direction because of the flat shape of the electron beam. For example, the spatial resolution was estimated to be about 15 µm in the vertical direction and 20 µm in the horizontal direction at M1 = M2 = 5.9 ([{\varphi_1}] = [{\varphi_2}] = 60°).

As a sample we observed a nylon mesh, the period of which was about 1.1 mm in both the horizontal and vertical directions. Fig. 5(a)[link] shows a raw image of the sample observed by the X-ray CCD camera at [{\varphi_1}] = [{\varphi_2}] = 60° (M1 = M2 = 5.9) with an exposure time of 4 s. The raw image is deformed by the optics. Fig. 5(b)[link] shows an image corrected by equation (5)[link] and the bilinear interpolation method. For comparison, Fig. 5(c)[link] shows a non-deformed magnified image observed at [{\varphi_1}] = [{\varphi_2}] = 90° (M1 = M2 = 10.0) with an exposure time of 8 s. The shape of the corrected image in Fig. 5(b)[link] is almost the same as that of the non-deformed magnified image in Fig. 5(c)[link]. This shows that the image correction by equation (5)[link] and the bilinear interpolation method was successful. It is worth noting that not only absorption-contrast but also edge-contrast due to Fresnel diffraction is observed in both Figs. 5(b) and 5(c)[link]. The number of observed Fresnel fringe was one in both the horizontal and vertical directions, and finer fringes were not observed. This is due to the moderate spatial resolution described above.

[Figure 5]
Figure 5
(a) Deformed magnified image and (b) corrected magnified image of the nylon mesh obtained at [{\varphi_1}] = [{\varphi_2}] = 60° (M1 = M2 = 5.9). (c) Non-deformed magnified image of the sample obtained at [{\varphi_1}] = [{\varphi_2}] = 90° (M1 = M2 = 10.0). The period of the nylon mesh was about 1.1 mm in both the horizontal and vertical directions.

During the course of the azimuth scan, we observed multiple Bragg diffractions at several points where the crystal did not work as a magnifier. We need to keep the azimuth angle away from these angles in order to obtain a normal magnified image. For this purpose, a so-called `glitch map' (Cole et al., 1962[Cole, H., Chambers, F. H. & Dunn, H. M. (1962). Acta Cryst. 15, 138-144.]) is helpful. This glitch map is also useful in determining the origin of the azimuth angle for precise image correction.

The throughput of the optics can be improved by replacing the asymmetric silicon crystals with asymmetric germanium crystals. For example, let us assume that the asymmetric Si(220) crystals ([{\alpha_1}] = [{\alpha_2}] = 14°, [{\theta_{{\rm{B}}1}}] = [{\theta_{{\rm{B}}2}}] = 16.96°) are replaced by asymmetric Ge(220) crystals ([{\theta_{{\rm{B}}1}}] = [{\theta_{{\rm{B}}2}}] = 16.26°). In order to secure the same range of magnification factor (0.1 ≤ Mj ≤ 10.0), the asymmetric angle of the Ge(220) crystals must be set at [{\alpha_1}] = [{\alpha_2}] = 13.42°. The intrinsic acceptance angle is calculated to be [6.8^{\,\prime\prime}\sqrt{M_1}] for the first magnifier and [5.8^{\,\prime\prime}\sqrt{M_2}] for the second magnifier. This means that the total throughput of the germanium magnifiers is increased by 265% compared with that of the silicon magnifiers.

In the experiment we could control the magnification factor from 1.0 up to 10 with reasonable throughput even at a second-generation synchrotron radiation facility such as the Photon Factory. In fact, the exposure time was as short as 10 s at the maximum magnification factor (M1 = M2 = 10). A much wider range of magnification factor will be realised at third-generation synchrotron radiation facilities where submicro­meter resolutions have already been achieved with the conventional fixed-magnification X-ray Bragg optics (Kobayashi et al., 2001[Kobayashi, K., Izumi, K., Kimura, H., Kimura, S., Ibuki, T., Yokoyama, Y., Tsusaka, Y., Kagoshima, Y. & Matsui, J. (2001). Appl. Phys. Lett. 78, 132-134.]; Schäfer & Köhler, 2003[Schäfer, P. & Köhler, R. (2003). J. Phys. D, 36, A113-A117.]). We expect that the performance of our variable-magnification X-ray Bragg optics will be maximized at linac-based X-ray sources such as X-ray free-electron lasers (McNeil & Thompson, 2010[McNeil, B. W. J. & Thompson, N. R. (2010). Nat. Photon. 4, 814-821.]) and energy-recovery linacs (Levi, 2002[Levi, B. G. (2002). Phys. Today, 55, 23-25.]), which can produce diffraction-limited X-rays in both the horizontal and vertical directions.

In this paper we demonstrated the X-ray beam magnification in view of controlling the spatial resolution and field of view of the optical system. Another important usage of the X-ray Bragg magnifier is beam demagnification (condensation) for micro-beam production (Tsusaka et al., 2000[Tsusaka, Y., Yokoyama, K., Takeda, S., Urakawa, M., Kagoshima, Y., Matsui, J., Kimura, S., Kimura, H., Kobayashi, K. & Izumi, K. (2000). Jpn. J. Appl. Phys. 39, L635-L637.]). Our X-ray Bragg optics opens up a new possibility for producing a variable-size micro-beam. Unlike other focusing elements such as Fresnel zone plates (Baez, 1960[Baez, A. V. (1960). Nature (London), 186, 958.]), compound refractive lenses (Schroer et al., 2005[Schroer, C. G., Kupanov, O., Patommel, J., Boye, P., Feldkamp, J., Lengeler, B., Burghammer, M., Riekel, C., Vincze, L., Hart, A. & Küchler, M. (2005). Appl. Phys. Lett. 87, 124103.]), Kirkpatrick–Baez mirrors (Kirkpatrick & Baez, 1948[Kirkpatrick, P. & Baez, A. V. (1948). J. Opt. Soc. Am. 38, 766-773.]) and capillaries (Nakazawa, 1983[Nakazawa, H. (1983). J. Appl. Cryst. 16, 239-241.]), our variable-magnification X-ray Bragg optics does not cause serious deterioration in beam parallelity. Thanks to this advantage, our X-ray optics will be useful for investigating the defects and strain fields in electric devices by micro-beam diffraction experiments.

4. Conclusion

We have developed a novel variable-magnification X-ray Bragg optics composed of two magnifiers in a crossed arrangement. Based on the dynamical theory of X-ray diffraction, we described the basic properties of the optics such as the magnification factor, image transformation matrix and intrinsic acceptance angle. In the feasibility test performed at the vertical-wiggler beamline BL-14B of the Photon Factory, we could control the magnification factor between 1.0 and 10 with reasonable throughput at the wavelength of 0.112 nm. Furthermore, we could successfully correct the image deformation caused by the optics using the image transformation matrix and bilinear interpolation method.

Acknowledgements

This work was performed with the approval of the Program Advisory Committee of the Photon Factory (2013G054 and 2014G021).

References

First citationAuthier, A. (2001). Dynamical Theory of X-ray Diffraction. Oxford University Press.  Google Scholar
First citationBaez, A. V. (1960). Nature (London), 186, 958.  CrossRef Web of Science Google Scholar
First citationBatterman, B. W. & Cole, H. (1964). Rev. Mod. Phys. 36, 681–717.  CrossRef CAS Web of Science Google Scholar
First citationBlasdell, R. C. & Macrander, A. T. (1994a). Nucl. Instrum. Methods Phys. Res. A, 347, 320–323.  CrossRef Google Scholar
First citationBlasdell, R. C., Macrander, A. T. & Lee, W. K. (1994b). Nucl. Instrum. Methods Phys. Res. A, 347, 327–330.  CrossRef Google Scholar
First citationBrauer, S., Stephenson, G. B., Mochrie, S. G. J., Dierker, S. B., Fleming, R. M., Pindak, R., Robinson, I. K., Grubel, G., Als-Nielsen, J. & Abernathy, D. L. (1995a). Rev. Sci. Instrum. 66, 1506–1509.  CrossRef CAS Google Scholar
First citationBrauer, S., Stephenson, G. B. & Sutton, M. (1995b). J. Synchrotron Rad. 2, 163–173.  CrossRef CAS IUCr Journals Google Scholar
First citationCole, H., Chambers, F. H. & Dunn, H. M. (1962). Acta Cryst. 15, 138–144.  CrossRef CAS IUCr Journals Web of Science Google Scholar
First citationDuMond, J. W. M. (1937). Phys. Rev. 52, 872–883.  CrossRef CAS Google Scholar
First citationHirano, K. (2011). Jpn. J. Appl. Phys. 50, 026402.  CrossRef Google Scholar
First citationHirano, K., Takahashi, Y. & Sugiyama, H. (2014a). Nucl. Instrum. Methods Phys. Res. A, 741, 78–83.  CrossRef CAS Google Scholar
First citationHirano, K., Takahashi, Y. & Sugiyama, H. (2014b). Jpn. J. Appl. Phys. 53, 040302.  CrossRef Google Scholar
First citationHönnicke, M. G. & Cusatis, C. (2007). Rev. Sci. Instrum. 78, 113708.  Web of Science PubMed Google Scholar
First citationHrdý, J. (1992). Rev. Sci. Instrum. 63, 459–460.  Google Scholar
First citationHrdý, J. & Pacherová, O. (1993). Nucl. Instrum. Methods Phys. Res. A, 327, 605–611.  Google Scholar
First citationIshikawa, T. & Kohra, K. (1991). Handbook on Synchrotron Radiation, Vol. 3, edited by G. S. Brown and D. E. Moncton, pp. 63–104. Amsterdam: North-Holland.  Google Scholar
First citationKhounsary, A. M. (1992). Rev. Sci. Instrum. 63, 461–464.  CrossRef Web of Science Google Scholar
First citationKirkpatrick, P. & Baez, A. V. (1948). J. Opt. Soc. Am. 38, 766–773.  CrossRef PubMed CAS Web of Science Google Scholar
First citationKobayashi, K., Izumi, K., Kimura, H., Kimura, S., Ibuki, T., Yokoyama, Y., Tsusaka, Y., Kagoshima, Y. & Matsui, J. (2001). Appl. Phys. Lett. 78, 132–134.  Web of Science CrossRef CAS Google Scholar
First citationKohra, K. (1972). Proceedings of the Sixth International Conference on X-ray Optics and Microscopy, edited by G. Shinoda, K. Kohra and T. Ichinokawa, pp. 35–45. University of Tokyo Press.  Google Scholar
First citationLee, W. K., Macrander, A. T., Mills, D. M., Rogers, C. S., Smither, R. K. & Berman, L. E. (1992). Nucl. Instrum. Methods Phys. Res. A, 320, 381–387.  CrossRef Google Scholar
First citationLevi, B. G. (2002). Phys. Today, 55, 23–25.  CrossRef Google Scholar
First citationMcNeil, B. W. J. & Thompson, N. R. (2010). Nat. Photon. 4, 814–821.  Web of Science CrossRef CAS Google Scholar
First citationMacrander, A. T., Lee, W. K., Smither, R. K., Mills, D. M., Rogers, C. S. & Khounsary, A. M. (1992). Nucl. Instrum. Methods Phys. Res. A, 319, 188–196.  CrossRef Google Scholar
First citationModregger, P., Lübbert, D., Schäfer, P. & Köhler, R. (2006). Phys. Rev. B, 74, 054107.  Web of Science CrossRef Google Scholar
First citationNakazawa, H. (1983). J. Appl. Cryst. 16, 239–241.  CrossRef CAS IUCr Journals Google Scholar
First citationSchäfer, P. & Köhler, R. (2003). J. Phys. D, 36, A113–A117.  Google Scholar
First citationSchroer, C. G., Kupanov, O., Patommel, J., Boye, P., Feldkamp, J., Lengeler, B., Burghammer, M., Riekel, C., Vincze, L., Hart, A. & Küchler, M. (2005). Appl. Phys. Lett. 87, 124103.  CrossRef Google Scholar
First citationSmither, R. K. & Fernandez, P. B. (1994). Nucl. Instrum. Methods Phys. Res. A, 347, 313–319.  CrossRef Google Scholar
First citationStampanoni, M., Borchert, G. & Abela, R. (2005). Nucl. Instrum. Methods Phys. Res. A, 551, 119–124.  Web of Science CrossRef CAS Google Scholar
First citationStampanoni, M., Borchert, G., Abela, R. & Rüegsegger, P. (2002). J. Appl. Phys. 92, 7630–7635.  Web of Science CrossRef CAS Google Scholar
First citationStampanoni, M., Borchert, G., Abela, R. & Rüegsegger, P. (2003). Appl. Phys. Lett. 82, 2922–2924.  CrossRef CAS Google Scholar
First citationTsusaka, Y., Yokoyama, K., Takeda, S., Urakawa, M., Kagoshima, Y., Matsui, J., Kimura, S., Kimura, H., Kobayashi, K. & Izumi, K. (2000). Jpn. J. Appl. Phys. 39, L635–L637.  CrossRef CAS Google Scholar
First citationUruga, T., Kimura, H., Kohmura, Y., Kuroda, M., Nagasawa, H., Ohtomo, K., Yamaoka, H., Ishikawa, T., Ueki, T., Iwasaki, H., Hashimoto, S., Kashihara, Y. & Okui, K. (1995). Rev. Sci. Instrum. 66, 2254–2256.  CrossRef CAS Web of Science Google Scholar
First citationVagovič, P., Korytár, D., Cecilia, A., Hamann, E., Švéda, L., Pelliccia, D., Härtwig, J., Zápražný, Z., Oberta, P., Dolbnya, I., Shawney, K., Fleschig, U., Fiederle, M. & Baumbach, T. (2013). J. Synchrotron Rad. 20, 153–159.  Web of Science CrossRef IUCr Journals Google Scholar
First citationVagovič, P., Švéda, L., Cecilia, A., Hamann, E., Pelliccia, D., Gimenez, E. N., Korytár, D., Pavlov, K. M., Zápražný, Z., Zuber, M., Koenig, T., Olbinado, M., Yashiro, W., Momose, A., Fiederle, M. & Baumbach, T. (2014). Opt. Express, 22, 21508–21520.  PubMed Google Scholar
First citationYabashi, M., Yamazaki, H., Tamasaku, K., Goto, S., Takeshita, K., Mochizuki, T., Yoneda, Y., Furukawa, Y. & Ishikawa, T. (1999). Proc. SPIE, 3773, 2–13.  CrossRef Google Scholar
First citationZachariasen, W. H. (1945). Theory of X-ray Diffraction in Crystals. New York: Wiley.  Google Scholar

© International Union of Crystallography. Prior permission is not required to reproduce short quotations, tables and figures from this article, provided the original authors and source are cited. For more information, click here.

Journal logoJOURNAL OF
SYNCHROTRON
RADIATION
ISSN: 1600-5775
Follow J. Synchrotron Rad.
Sign up for e-alerts
Follow J. Synchrotron Rad. on Twitter
Follow us on facebook
Sign up for RSS feeds