Reaction microscope endstation at FLASH21
aMax-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg, Germany, and bDeutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
*Correspondence e-mail: georg.schmid@mpi-hd.mpg.de, robert.moshammer@mpi-hd.mpg.de
A reaction microscope dedicated to multi-particle coincidence spectroscopy on gas-phase samples is installed at beamline FL26 of the free-electron laser FLASH2 in Hamburg. The main goals of the instrument are to follow the dynamics of atoms, molecules and small clusters on their natural time-scale and to study non-linear light–matter interaction with such systems. To this end, the reaction microscope is combined with an in-line extreme-ultraviolet (XUV) split-delay and focusing optics, which allows time-resolved XUV-XUV pump–probe spectroscopy to be performed.
Keywords: time-resolved molecular dynamics; non-linear light–matter interaction; reaction microscope; multi-particle coincidence spectroscopy; free-electron laser; XUV–XUV pump–probe spectroscopy.
1. Introduction
A complete picture of the formation, internal rearrangement and the break-up of a molecule is only obtained if the evolution of the reaction is observed in a time-resolved manner (Zewail, 2000). As underlying processes like charge migration and energy redistribution within the molecule typically happen within a few to tens of femtoseconds, a spectroscopic technique that is fast enough to record the reaction is needed (Zewail, 1988). With the invention of short-wavelength free-electron lasers (FELs) (Ackermann et al., 2007), the research area of atomic, molecular and optical (AMO) physics obtained a new experimental tool that provides femtosecond light pulses of extreme-ultraviolet (XUV) photons at unprecedented intensities (Feldhaus et al., 2013; Yabashi et al., 2013; Callegari et al., 2016). The unique properties of XUV FEL pulses allow XUV pump–probe spectroscopy to be employed to study dynamical processes like isomerization (Jiang et al., 2010a), nuclear wave-packet oscillations in molecules (Jiang et al., 2010b; Magrakvelidze et al., 2012), interatomic Coulombic decay (Schnorr et al., 2013), electron rearrangement in dissociating molecules (Schnorr et al., 2014), the expansion of clusters (Krikunova et al., 2012; Sauppe et al., 2018), non-equilibrium transient states in functional solids (Pontius et al., 2018) and attosecond interferometry (Usenko et al., 2017). Furthermore, short-wavelength FELs open up a new regime in non-linear light–matter interaction, e.g. multi-photon ionization can now be studied at XUV photon energies (Sorokin et al., 2007b; Moshammer et al., 2007; Richter et al., 2009; Hikosaka et al., 2010; Gerken et al., 2014).
Besides an appropriate light source, a detection apparatus, which extracts the essential information on the process under investigation, is decisive.
Reaction microscopes (REMIs) are state-of-the-art coincidence momentum imaging spectrometers to resolve and study fundamental reactions in atoms or molecules, triggered upon collisions with ions, the impact of electrons or absorption of photons (Ullrich et al., 2003).
Taking advantage of the synergy arising from the combination of a REMI and a high-repetition-rate XUV FEL (Rudenko et al., 2010; Moshammer & Schnorr, 2014), a dedicated user endstation is installed at beamline FL26 of the free-electron laser FLASH2 (Plönjes et al., 2016; Faatz et al., 2016). Fig. 1 shows the layout of the endstation. In this paper, the main components are introduced and commissioning results are discussed.
2. Reaction microscope
Reaction microscopes are multi-particle coincidence spectrometers for AMO physics, which allow measuring the initial energies and emission angles of the charged products, i.e. ions and electrons, of fundamental atomic and molecular reactions in the gas phase (Moshammer et al., 1996; Dörner et al., 2000).
To this end, the charged reaction fragments, i.e. atomic or molecular ions and electrons, are accelerated onto large-area time- and position-sensitive detectors. By measuring the time-of-flight (TOF) and the impact position of the particles on the detectors, the initial three-dimensional momentum vectors can be reconstructed. While the ions carry information about the nuclear dynamics during a reaction, the ejected electrons are sensitive to the electronic structure of the system under investigation. In the ideal case, electrons and ions are measured in coincidence and, by applying momentum conservation, fragments emerging from a single atom or molecule can be selected. This enables so-called kinematically complete experiments to be performed (Kurka et al., 2009).
The REMI installed at FLASH2 is schematically shown in Fig. 2. The FEL beam (purple) is focused into a supersonic gas jet (cf. Section 2.1), which contains the target atoms, molecules or clusters (green spheres). Created ions (red trajectory) and electrons (blue trajectory) are separated by their different charges and guided onto opposing detectors (cf. Section 2.3) by the electric field of the spectrometer (cf. Section 2.2). The magnetic field generated by a pair of Helmholtz coils forces the electrons in cyclotron orbits on their way to their detector. The combination of a homogeneous electric and magnetic field ensures a solid-angle acceptance of 4π for all ions and electrons of interest. In the following, the key components of the REMI are introduced.
2.1. Target injection
The target preparation is based on supersonic expansion of gas-phase samples. For this, gas is expanded through a nozzle from a high-pressure reservoir into vacuum and a supersonic jet is formed. In doing so, the undirected thermal energy of the gas particles is transformed into directed ).
which results in a decrease of internal temperature. The achieved temperature depends on several parameters, in particular on the specific gas, the nozzle diameter, the backing pressure and the temperature of the gas before the expansion (Scoles, 1988Three different nozzle assemblies are available at the REMI endstation. Firstly, a cooled nozzle allows to pre-cool the gas before the expansion. Cooling down to cryogenic temperatures is achieved by using a closed-cycle helium refrigerator cold-head, and very low jet temperatures are reached (for example ∼0.5 K for a helium jet). This results in very low momentum uncertainty of the target atoms or molecules. Hence, this nozzle assembly is suited for experiments that ask for a high-momentum resolution for the recoil-ions (Kurka et al., 2010). Secondly, a heatable nozzle can be installed to inject liquid and solid samples with low vapor pressure (Schnorr et al., 2014). It is based on sublimating the sample in a heatable reservoir outside of the vacuum. The molecules are then carried to the nozzle by a seeding gas or the vapor pressure. An increasing temperature gradient from the reservoir to the nozzle circumvents re-sublimation and, thus, clogging of the system. The heatable nozzle can operate up to temperatures of 200°C. Thirdly, a nozzle assembly where the reservoir for liquid samples is integrated into the is available. The design is based on evaporating the liquid as close as possible to the nozzle to prevent clogging by condensation. The system can be operated with and without a seeding gas. Using this nozzle assembly, the generation of water and water–rare-gas dimers has been accomplished (Meister, 2016).
The experimental implementation of the jet system is shown in Fig. 3. It features six vacuum stages that are differentially pumped. Hence, despite backing pressures of up to 70 bar in the nozzle, ultra-high-vacuum (UHV) conditions are preserved in the REMI interaction chamber (cf. Section 2.4). In order to form a supersonic jet, the gas expands from a high-pressure reservoir (0) through the nozzle (typical diameters 5−50 µm) into the vacuum of the first jet stage (1). A sharp-edged conical skimmer made of pure copper (inner diameter: 180 µm) is coaxially opposing the nozzle to peel off gas particles from the so-called zone of silence (cf. inset Fig. 3), i.e. a region where gas particles have supersonic speeds and low internal temperatures. A subsequent second skimmer (2) (inner diameter: 400 µm) geometrically selects only gas particles with a small momentum spread in the direction perpendicular to the jet-propagation direction (cf. inset Fig. 3). The nozzle assemblies introduced above are mounted on a triaxial xyz-manipulator, which allows adjustment of the distance between the nozzle and the first skimmer in the x-direction as well as the position in the perpendicular (y, z)-plane. The coordinate system is shown in Fig. 3. The subsequent stages (3, 4, 5, 6) are separated by apertures of 2 mm inner diameter. Three pairs of slits (two vertical, one horizontal) in the stages 4, 5 and 6 allow tuning of the jet divergence in the (y, z)-plane and thus the target extension along the FEL beam direction. Finally, a spatially well confined (diameter ≤ 2 mm), dilute (≤1010 particles cm−3) and cold (typically <20 K) beam of atoms, molecules or clusters enters the REMI spectrometer (cf. Section 2.2). The portion of the jet which is not ionized is collected in the jet dump to avoid an increase of gas pressure in the REMI interaction chamber. The REMI interaction chamber, jet dump stage (i) and jet dump stage (ii) are separated by tubes of 4 mm inner diameter for differential pumping.
2.2. Spectrometer
The REMI spectrometer is schematically depicted in Fig. 2. It consists of ring-electrodes to create a homogeneous electric field at the interaction point and between the two detectors of the REMI. The rings are separated by a distance of 10 mm and are made of annealed stainless steel. They have an inner diameter of 120 mm, an outer diameter of 200 mm and are 1 mm thick. The individual rings are electrically connected by a cascade of 100 kΩ resistors and a fixed voltage can be applied across the spectrometer. The inner boundaries of the rings are sharply edged towards the center to generate well defined equipotential planes. This ensures a homogeneous electric field over the entire inner volume of the spectrometer. Fine-meshed stainless steel grids (wire diameter: 30 µm; mesh size: 224 µm; transmittance: ∼80%) at both ends of the spectrometer ensure a defined termination of the electric field.
The spectrometer has a total length of 275 mm. In order to optimize the acceptance for ions with high kinetic energies, which emerge, for example, from Coulomb explosion of molecules (Schnorr et al., 2014), the ion side of the spectrometer is kept short (94.5 mm). The electron side is about a factor of two longer. An ion (red trajectory in Fig. 2) of mass m and charge q that is created at the interaction point (center of the REMI) with zero initial momentum reaches the detector after the time-of-flight
Here, U is the applied voltage and d is the distance between the interaction point and the detector. The proportionality of the TOF to the square root of the [cf. equation (1)] allows different ion species to be distinguished. The spectrometer does not have a field-free drift region or, in other words, the constant electric field is active over the whole length of the spectrometer, i.e. from the ion to the electron detector. A drift region, for, for example, time focusing (Wiley & McLaren, 1955), is not implemented since the starting point of the ions' and electrons' TOF is well defined by the small FEL focal spot diameter of <10 µm (cf. Section 5.1). Furthermore, a drift region would geometrically reduce the acceptance of the ion detector for ions with high kinetic energies.
Electrons with the same momenta as the recoiling ions move with much higher velocities compared with the heavier ions (mproton/me ≃ 1836). With high probability they would leave the spectrometer transversally and miss the electron detector. To avoid this, a magnetic field is applied parallel to the electric field. In the magnetic field electrons fly in cyclotron orbits to their detector (blue trajectory in Fig. 2). The magnetic field (of the order of B ≃ 10 Gauss) is generated by a pair of Helmholtz coils (cf. Fig. 2). As the cyclotron frequency is given by ω = qB/m, the trajectories of the heavier ions are not measurably changed by the magnetic field.
As ions from Coulomb explosions can have high kinetic energies, high electric fields of up to 100 V cm−1 must be applied to the spectrometer to achieve full angular acceptance for these ions. The actual acceptance depends on several parameters, in particular charge state and mass of the ions, as well as the velocity offset that the particles already have as they are contained in a propagating gas jet (cf. Section 2.1) before interacting with the FEL. Taking typical values for these parameters, the spectrometer has at least a full angular acceptance for ions with kinetic energies of up to 40 eV. In order to measure electrons and ions in coincidence with sufficient resolution, lower electric fields (≤10 V cm−1) need to be applied. In this operation mode, the spectrometer typically has a full angular acceptance for electrons with maximum kinetic energies of about 40 eV.
2.3. Detectors
Large-area micro-channel plate (MCP) detectors are used to measure the TOF and the impact position of ions and electrons. Each detector is equipped with a stack of MCPs (Wiza, 1979), which generates the signals and allows the TOF information to be extracted. A delay-line anode (Lampton et al., 1987) located behind the MCPs is used to obtain the position information. Fig. 4 gives an overview of the detector assembly and its working principle (Jagutzki et al., 2002b).
An impinging primary particle (ion or electron) initiates an electron avalanche in a channel of the MCPs. This leads to a drop in the voltage over the MCPs, which gives a signal [cf. Fig. 4(b)]. The TOF is measured relative to the FEL trigger: TOF = tMCP − ttrigger. The signal of tMCP is read out capacitively. After the MCPs, the electron cloud is attracted by the delay-line anode. The induced signal propagates to both ends of the delay-line wire [cf. Fig. 4(c)]. One of the position coordinates is given by x = . Here, t1 = t1* − tMCP and t2 = t2* − tMCP are the arrival times of the signal at the ends of the wire relative to the MCP timing signal tMCP. The effective propagation velocity of the signal along the wire is denoted by v⊥.
The ion detector is equipped with a stack of two 120 mm-diameter MCPs in a chevron arrangement [cf. Fig. 4(b)] and a delay-line anode. Specifically, it is a so-called quadanode as it consists of two perpendicularly oriented quadratic wire layers [cf. Fig. 4(a)]. The electron detector features three MCPs of 80 mm diameter in a Z-arrangement and a delay-line anode, which is made of three wire layers that are rotated by 60° relative to each other. This so-called hexanode delay-line anode improves the multi-particle hit by introducing redundancy (Jagutzki et al., 2002a).
2.4. Vacuum conditions
All ions and electrons, which are created inside the volume of the spectrometer (cf. Section 2.2), are accelerated towards the detectors (cf. Section 2.3) and are registered as events. The detectors, however, cannot discriminate between particles from the target and those from residual gas. At XUV photon energies above ∼15 eV, a single photon can ionize a residual gas molecule (e.g. H2, H2O, N2, O2). The XUV photoabsorption cross sections of residual-gas molecules and those of target atoms, molecules or clusters are of the same order of magnitude (Yeh & Lindau, 1985; Gallagher et al., 1988). In combination with FEL pulse energies of the order of some tens of µJ, this causes a non-negligible number of background events along the FEL beam inside the REMI spectrometer.
To minimize the number of background events, vacuum conditions of ≤10−11 mbar need to be reached in the REMI interaction chamber. The generation of such high vacua in a large vessel like the REMI interaction chamber (CF DN250 tube, length ∼80 cm) is difficult to achieve by turbomolecular pumps alone. Thus, the complete inner surface of the interaction chamber is coated with a thin film (∼1.5 µm) of non-evaporable getter (NEG) material. NEG is a special alloy, e.g. Ti–Zr–V, which has a large surface area. Thereby, the probability of molecules to stick to the chamber walls is increased. At extreme vacua (∼10−12 mbar), the thermal outgassing of H2 from the steel walls of the chamber is the major source of residual gas (Benvenuti et al., 1999). However, turbomolecular pumps are not well suited to pump H2 with typical H2 pumping speeds of only several hundreds l s−1 (Jousten, 2010). In contrast, the H2 pumping speed of the NEG coating of the REMI interaction chamber is estimated to be ∼3600 l s−1 (Benvenuti et al., 1999). However, after each venting, the coating needs to be re-activated by heating the chamber to temperatures of ≥200°C for at least 24 h (Benvenuti et al., 1999).
2.5. Data acquisition
FLASH features a special pulse repetition rate pattern. At 10 Hz repetition rate, pulse trains (maximum train length 800 µs) with an intra-train pulse separation between 1 and 25 µs are provided (Faatz et al., 2016). This burst-mode pulse pattern requires a data acquisition system, which is capable of processing the incoming signals of a REMI.
Four Acqiris DC282 digitizer cards, each with four channels, are used to record the voltage traces of each and every detector signal over a time range up to 800 µs. The highest sampling rate of the digitizer cards is 2 GHz (0.5 ns between two samples) and the maximum voltage range for each channel is ±5 V. The voltage trace for each channel recorded during the entire pulse train is stored internally on the digitizer cards. Then, the 10 Hz FEL trigger initiates the readout of the channels after the end of each pulse train. Zero suppression, peak finding on the signals and sorting of the data is done by computer algorithms in the online as well as the offline analysis (Schnorr, 2014). The analysis code GENERiC (General Analysis Code for Reaction Microscopes) is embedded in the Go4 (GSI Object Oriented On-line Off-line system) analysis environment (GSI, 2018) based on CERN's ROOT (CERN, 2018).
3. In-line XUV split-delay and focusing optics
The basic concept of the XUV optics is to split and focus the FEL beam before it enters the REMI.
The underlying geometry and working principle is depicted in Fig. 5. The FEL beam approaches from the left and first hits the split-mirror under a grazing angle of θ = 8°. The split-mirror is a plane mirror, which is horizontally cut into two coextensive pieces. The upper mirror is movable and can be translated back and forth along the mirror normal axis. Thus, a path difference can be introduced between the upper beam (green) and the lower beam (blue). The incoming FEL pulse is split into two and the path difference translates into a temporal delay td between the pump (blue) and the probe (green) pulse. After the splitting, the two beams are focused by an ellipsoidal mirror into the supersonic jet of the REMI. The grazing-incidence geometry and a carbon coating of the split and the ellipsoidal mirror guarantee high reflectivity over a broad photon energy range from 30 to 180 eV (cf. Fig. 7). This allows making use of the wavelength tunability of the FLASH2 variable-gap undulators (Faatz et al., 2016). The use of a single ellipsoidal mirror instead of a KB focusing system, implemented at other beamlines at FLASH (Erk et al., 2018), reduces the number of optical components in the beam path and thus increases the overall transmission of the beamline.
3.1. Split-mirror assembly
The split-mirror is the centerpiece of the XUV pump–probe optics. It consists of two plane mirrors with clear apertures of 120 mm × 10.5 mm each. In order to achieve femtosecond pump–probe resolution and to keep spatial overlap of both beams in the focus for all delay values, the upper mirror is movable by a kinematics based on piezo positioners. The split-mirror assembly is shown in Fig. 6.
The kinematics is custom-made by SmarAct GmbH. It allows the position of the upper mirror to be manipulated in three dimensions: linear motion along the mirror normal axis (travel), rotation along the vertical (tilt) and horizontal (tip) axis. The coordinate system is defined in Fig. 6. The rotational axes are set along the mirror surface. The maximum travel range of h = ±3 mm along the mirror normal translates into a maximum delay range of td = ±2.7 ps. Rotations up to a few degrees are possible for the tilt axis. The maximum tip rotation of ±20 mrad is limited by the minimal allowed gap distance of 100 µm between the two mirrors. The gap is intended to be as small as possible in order to minimize photon losses. The distance between the mirrors can be manually adjusted by three spring-mounted fine-thread screws.
The kinematics has three legs, each consisting of a linear piezo positioner, a linear guideway and a bearing (cf. Fig. 6). Due to the guideways and the bearings, linear motions of the piezo positioners translate into a linear motion along the travel direction and rotations around the tip or tilt axis. The positioners are SmarAct SLC-1730 nanometer-precision linear piezo positioners, which are based on the stick–slip principle (Hunstig, 2017). They are operated in closed-looped (encoder feedback) and are controlled by the SmarAct MCS controller module with the Advanced Sensor Calibration (ASC) option.
Based on the position resolution of the encoders (4 nm), the upper limit of the temporal resolution is estimated to be Δtd ≃ 4 as. Tests employing the interference pattern of an optical laser (wavelength 658 nm) confirm this limit. Tests on the pointing stability, i.e. the ability to maintain spatial overlap of both beams in the focus for all delays, are presented in Section 5.2.
3.2. Ellipsoidal mirror
After the split-mirror, the beam is focused by an ellipsoidal mirror (cf. Fig. 5). It is designed for a source distance of 85 m, a focal length of 1 m and an incidence angle of θ = 8°. The machining of the mono-crystalline silicon substrate was performed by Carl Zeiss SMT GmbH. The clear aperture of the mirror is 180 mm × 20 mm. The quality inspection of the manufacturer specifies the slope errors to be 0.84 arcsec (r.m.s.) tangential and 1.2 arcsec (r.m.s.) sagittal. The surface roughness is measured to be 0.19–0.24 nm. For high transmission over a broad XUV photon energy range, the mirror is coated with a 30 nm thin layer of carbon by optiXfab GmbH. The layer thickness has a relative error of ±5% and the lateral is >97%. At θ = 8°, the mirror has a reflectivity of >50% up to photon energies of 180 eV (cf. Fig. 7).
The split-mirrors are also carbon-coated in the same way and the mono-crystalline silicon substrates are of the same quality as the ellipsoidal mirror.
3.3. Hexapod kinematics
To obtain best focusing conditions and high transmission, the split and the ellipsoidal mirror need to be individually positioned in all three rotational and translational directions with microradian- and micrometre-precision. In order to achieve these accuracies, hexapod kinematics as shown in Fig. 8 are used.
The split-mirror assembly and the ellipsoidal mirror have their individual kinematics, which are mounted on two separate flanges of one vacuum chamber. A decoupled adjustment of both mirrors is essential for beam alignment and also indispensable to achieve optimal focusing conditions as well as to compensate manufacturing tolerances of the mirror chamber. The mounting on two separate supporting flanges also enables an independent removal of both mirror assemblies.
The general design of the kinematics has been developed by the group around T. Noll and Th. Zeschke from the Helmholtz Zentrum Berlin (HZB)/BESSYII (Noll et al., 2009). The design has been adapted by FMB Berlin GmbH, who also manufactured the kinematics and the surrounding vacuum chamber.
The hexapod has six legs, each consisting of two steel rope joints, a connection strut, a leaf spring, a bellow and a motorized actuator (cf. Fig. 8). By linearly pulling or pushing of the actuators, the legs react dynamically and the attached platform moves. The design uses stable steel rope joints instead of conventional bearings to increase the overall stiffness. The flexible copper–beryllium leaf springs prevent a lateral displacement of the upper joint in stressed positions of the joints. In contrast to usual hexapods, the driving motors are not directly part of the moving assembly. This decreases the total mass and potentially outgassing electrical parts stay outside the vacuum. Bellows separate the actuators from the vacuum. After baking of the vacuum chamber at 120°C for about 24 h, a pressure of 10−10 mbar was reached in the mirror chamber.
The hexapods are designed for rotations of Rx, Ry, Rz = ±0.5° and translations of Tx, Ty = ±3 mm laterally and Tz = ±5 mm vertically. The vertical travel of Tz = ±5 mm for the split-mirror assembly allows the complete FEL beam (10 mm diameter) to be put onto one of the split-mirrors. This option is used for experiments, which do not employ an XUV–XUV pump–probe scheme, e.g. XUV–IR pump–probe experiments (cf. Section 6). Tests have shown that the resolution for all translations is ΔTx, y, z ≃ 0.1 µm and for all rotations ΔRx, y, z ≃ 1 µrad. The movement of the hexapods is controlled by a LabVIEW program.2
4. Beamline
4.1. Accelerator tunnel section and experimental hall
An overview of the FEL beam transport and diagnostics at FLASH2 has been given by Plönjes et al. (2016). In the tunnel section, beam position monitors and a set of apertures followed by Ce:YAG fluorescence screens are used to monitor and to shape the FEL beam. The apertures are also utilized to adjust the transmitted pulse energy. The absolute pulse energy can be measured by a gas-monitor detector (GMD) (Tiedtke et al., 2009) or a micro-channel plate (MCP) tool (Bittner et al., 2007). A non-invasive online spectrometer (OPIS) measures the average photon energy (Braune et al., 2016). The accelerator tunnel section ends with a gas-filled attenuator, which allows the transmitted energy per pulse to be continuously adjusted.
The photon-diagnostics section in the experimental hall is equipped again with a second GMD, a further set of apertures and Ce:YAG fluorescence screens. Transmission filters are mounted to regulate the FEL intensity and to suppress harmonics. The filters of different materials and thicknesses (typically a few 100 nm) are mounted on two consecutive motorized wheels. Depending on the photon energy and intensity, different filters and combinations can be selected.
4.2. REMI beamline
In order to protect the vacuum conditions in the REMI interaction chamber (≤10−11 mbar) from the vacuum in the FLASH beamline (typically >10−9 mbar) and to reduce stray light, the beamline in front of the REMI is separated into five differentially pumped sections and has a total length of ∼6.3 m (cf. Fig. 9).
The sections are connected via small-diameter tubes (colored orange in Fig. 9) which leads to low gas conductance between the sections. The tubes are configured to reduce stray light. At the entrance and exit, chamfered copper apertures are clamped into the tubes. The chamfer is manufactured as sharp as possible in order to minimize the area where photons might scatter. The apertures have an inner diameter of 18 mm, while the tubes (lengths between 185 and 287 mm) themselves have an inner diameter of 26 mm [cf. Fig. 9(a)]. This configuration acts as a light baffle for photons that are scattered in off-axis directions.
After the mirror chamber, a further light baffle (colored blue in Fig. 9) is installed to prevent stray light in the direct vicinity of the REMI detectors. This light baffle consists of two apertures with respective inner diameters of 14 mm and 12 mm [cf. Fig. 9(b)]. They are made of roughened 625 µm thin silicon wafers and serve the same purpose as the copper apertures of the differential tubes, i.e. to remove undirected scattered photons.
At two distinct positions along the beamline, circular apertures on a moveable rail (aperture diameters from 4 to 10 mm in steps of 1 mm) are integrated (colored dark-green in Fig. 9). The apertures are chamfered with the sharp edge pointing towards the incoming beam again for reasons of stray light reduction. Additionally, the apertures' surfaces facing the beam are coated with a fluorescent ZnS powder, which facilitates the beam alignment. A third aperture (diameter 10 mm) which is part of the IR incoupling unit (colored red in Fig. 9, discussed in Section 6) is located directly in front of the REMI interaction chamber.
In total, three fluorescence screens (colored light-green in Fig. 9) can be inserted to monitor the position and the shape of the FEL beam. The first screen (20 mm × 20 mm) is located in front of the mirror chamber. A second screen (25 mm × 25 mm) can be placed between the split and the ellipsoidal mirror to monitor the shape of the split beam and the illumination uniformity on the split-mirrors. A third screen (20 mm × 20 mm) is located in front of the REMI. Each screen consists of a stack of a Ce:YAG plate (200 µm thick) and a roughened silicon plate (625 µm thick). The Ce:YAG plate faces the FEL beam and fluoresces upon illumination with XUV photons. The roughened silicon plate, which is mounted behind the Ce:YAG plate, is used to visualize the optical alignment laser (wavelength 658 nm).
A pair of horizontal slits (colored light-brown in Fig. 9) can be used to block the upper or the lower part of the incoming FEL beam. This option is useful for adjusting the downstream XUV split-delay and focusing optics (cf. Section 3), e.g. to check how the pulse energy in the pump and the probe pulse is distributed.
4.3. REMI interaction chamber and photon dump
In order to spatially overlap the foci at the nominal interaction point with the gas jet (cf. Section 3), a fluorescence screen can be moved into the center of the REMI spectrometer. This target screen is 10 mm × 10 mm in size and coated with a thin film of Ce:YAG powder. A CCD camera (Basler acA1300-30gc with Sony ICX445 CCD sensor, 1.3 MP, pixel size 3.75 µm × 3.75 µm, sensor size 4.9 mm × 3.6 mm) in combination with an optical magnification system (Navitar 1-60135D, overall magnification 2.4) images the fluorescence of the foci from outside. The vacuum of the REMI interaction chamber is separated from the following photon dump by two differentially pumped sections. The corresponding differential tubes are colored orange in Fig. 10.
The beam profile and position after the REMI can be monitored by a Ce:YAG fluorescence screen (20 mm × 20 mm) (colored light-green in Fig. 10). The fluorescence screen is followed by a 1 m-long CF DN40 tube. Two bellows (colored yellow in Fig. 10) at each end allow to slightly tilt or bank out the entire tube. This option is applied to minimize photon back-scattering from the FEL dump. The photon dump is terminated by a copper plate, which is electrically connected (colored brown in Fig. 10). The voltage signals induced by impinging FEL pulses serve as a reference for the pulse arrival times and the pulse energies. From the first valve (colored light-blue in Fig. 10) onwards, the entire photon dump is mounted on a single supporting frame. This way, it can be quickly removed for setting up a subsequent optional experiment behind the REMI. The first valve is located 827 mm behind the center of the REMI. Taking the maximum diameter of 10 mm of the incoming FEL beam before focusing, the diverging FEL beam has a maximum diameter of ∼8.3 mm at this position.
5. Commissioning results
5.1. Focal spot size
A wavefront sensor (WFS) (Keitel et al., 2016) has been used to analyze the optical properties of the new XUV split-delay and focusing optics (cf. Section 3). For the measurements at ℏω = 56 eV a Compact Hartmann Sensor (Keitel et al., 2016) was used. The intensity profile of the smallest achieved focus is shown in Fig. 11.
A diameter of d ≃ 3 µm (FWHM) was obtained. Assuming a pulse energy of Epulse = 10 µJ and a typical of T = 50 fs, this corresponds to an intensity of I ≃ 1015 W cm−2.
The charge states reached in multi-photon ionization of xenon are a further benchmark of the achieved intensity and thus the focus size. Fig. 12 shows the TOF spectrum of xenon ions recorded at a photon energy of ℏω = 100 eV and a pulse energy of Epulse ≃ 20 µJ.
For this measurement, the entire FEL beam was placed onto the lower split-mirror to avoid losses due to the gap between the two mirrors. For each charge state several close-lying TOF peaks appear reflecting the naturally abundant isotopes of xenon. The charge states are marked by arrows and Xe15+ is the highest charge state observed. Richter et al. (2009) measured Xe14+ at I = 1.7 × 1015 W cm−2 and Sorokin et al. (2007a) reported Xe15+ at I = 2 × 1015 W cm−2. Taking these values, the intensity reached with the present setup is estimated to be 1 × 1015 to 2 × 1015 W cm−2. This is in accordance with the focal spot size measured with the WFS for the given pulse energy of Epulse ≃ 20 µJ and an estimated of T = 50 fs. In XUV pump–probe operation, the FEL beam is put on both split mirrors. In this configuration, the highest recorded charge state is Xe11+, which according to Sorokin et al. (2007a) corresponds to an intensity of I ≃ 5 × 1014 W cm−2.
5.2. Pointing stability of the split-mirrors
It is crucial for any pump–probe experiment to maintain spatial overlap of the two foci during delay scans. In order to determine the pointing stability of the split-mirror assembly (cf. Section 3.1), the target screen is moved to the nominal focal position in the center of the REMI spectrometer (cf. Section 4.3). The FEL intensity needs to be strongly attenuated by the beamline filters (cf. Section 4.1) to not destroy the screen. The fluorescence spots of the movable and the fixed focus are then observed by the CCD camera with the optical magnification system from outside (cf. Section 4.3). The CCD camera is read out with the 10 Hz FEL trigger. The two foci are spatially separated by about 150 µm, which allows the centroid positions of the fluorescence spots [spot sizes 64 ± 12 µm (FWHM)] of the movable and the fixed focus to be determined. To this end, both spots are selected by regions of interest. These regions are then projected, background is subtracted and the centroids are calculated from the center-of-mass of the projections. A sub-pixel resolution of below 1.6 µm is reached with this method. The delay is scanned and for each delay step the centroid position of the spot of the movable focus is determined relative to that of the fixed focus in the horizontal (x) and vertical (y) direction. The relative deviation Δx of the centroid positions in the x-direction is plotted as a function of the pump–probe delay in Fig. 13(a).
For this plot, the entire delay range has been scanned four times. Between Δx(−2000 fs) = +15 µm and Δx(+2000 fs) = −30 µm, an absolute deviation of 45 µm exists. Additionally, anharmonic oscillations are superimposed on this almost linear slope. The origin of this non-linear behavior is not understood. It might be caused by an imperfect synchronization of the movements of the three piezo positioners (cf. Section 3.1). In order to compensate the slope and the anharmonic oscillations, the position versus delay curve is recorded in a separate calibration measurement and interpolated by splines, which is then used for correcting the movements of the piezo kinematics. Four delay scans using the correction are superimposed in Fig. 13(b). The small width of the distribution [cf. inset of Fig. 13(b)] shows the high precision and reproducibility of the piezo kinematics. The 1σ-deviation over the entire delay range is σΔx = (2.2 ± 0.5) µm. In the vertical direction Δy, corrections are also necessary and a comparable stability is achieved as well. Hence, for pump–probe experiments, the two foci are spatially well overlapped when the delay-dependent correction obtained by the method introduced above is applied.
5.3. Stray-light reduction
Stray light, i.e. scattered XUV photons that trigger events at the ion or electron detector of the REMI (cf. Section 2.3), is a major source of background events. With the in-line XUV split-delay and focusing optics (cf. Section 3), a significant reduction of stray light is achieved compared with a formerly used back-reflecting split-mirror (Jiang et al., 2010a; Schnorr et al., 2013). Using similar FEL pulse energies, the stray light background is reduced by a factor of about 15. In the previous setup, an FEL beam of 10 mm diameter first passed the REMI interaction chamber before it was focused into the gas jet. This back-reflecting geometry facilitated undirected scattered photons. With the new split-delay and focusing optics, however, a well collimated FEL beam passes the REMI interaction chamber only once.
5.4. Electron-ion coincidences
As a next step, after commissioning of the FEL beamline, the REMI itself was tested. To this end, two-photon double-ionization (TPDI) of neon at a photon energy ℏω = 44 eV has been studied using the in-line XUV optics (cf. Section 3). At a photon energy of 44 eV, TPDI proceeds via the so-called sequential channel: the absorption of one photon leads to the formation of a real intermediate state of the singly charged Ne+ ion, which then absorbs a second photon resulting in a doubly charged Ne2+ ion,
Although the two ionization steps might be regarded as completely independent at first glance, the two ejected electrons (e1 and e2) are correlated, which is, for example, reflected in the angular distributions of the first- and second-step electrons (Kheifets, 2007; Fritzsche et al., 2008; Grum-Grzhimailo et al., 2009). To unambiguously measure the angular distribution of the first-step electron in TPDI, this electron needs to be distinguished from an electron emerging from another ionization event. This is possible, if the two ejected electrons (e1 and e2) and the corresponding Ne2+ ion are measured in coincidence [cf. equation (2)].
A so-called photoelectron–photoelectron–photoion coincidence (PePePiCo) map may be used as feedback as to whether the coincident detection of electrons and ions was successful. In such a plot, the ion TOF is plotted against the sum of the TOFs of the first and the second electron arriving at the detector. The PePePiCo plot for TPDI of neon at a photon energy of ℏω = 44 eV is shown in Fig. 14.
In a true coincident event, the sum momentum of all ejected particles (electrons and ions) is constant. As the TOF of a particle is in first approximation directly proportional to its momentum, the diagonal line in Fig. 14 indicates the coincident detection of a Ne2+ ion and the two ejected electrons. According to the geometry of the REMI spectrometer (cf. Fig. 2), an ion that starts with an initial momentum towards the ion detector has a shorter TOF. Due to momentum conservation, the corresponding electrons start with initial momenta towards their detector and the sum TOF1 + TOF2 is short as well. In the opposite case, i.e. where the ion has an initial momentum towards the electron detector, the ion TOF is larger and thus also the sum TOF of the two electrons is larger. The PePePiCo map of Fig. 14 shows that with the background reduction (cf. Section 5.3) achieved by the design of the beamline (cf. Section 4.2) and by focusing with the in-line XUV optics (cf. Section 3), detailed studies on two- and multi-photon ionization of atoms, molecules and small clusters are possible at the REMI endstation. In contrast to previous experiments, e.g. TPDI of Ne at 44 eV has already been studied using a REMI at FLASH1 (Kurka et al., 2009), these studies can now be carried out in a time-resolved manner using the in-line XUV split-delay and focusing optics (cf. Section 3).
5.5. Delay-dependent release spectra
The fragmentation of argon dimers (Ar2) at a photon energy of ℏω = 24.8 eV is taken as a case study to test the pump–probe capability of the split-delay and focusing optics. The release (KER) of the dimer fragments is measured as a function of the pump–probe delay. The KER is approximately given by
with q1 and q2 being the ion charges [atomic units are used in equation (3)]. The dependence of the KER on the internuclear distance R allows conclusions to be drawn on the nuclear dynamics during the fragmentation. In Fig. 15, the KER of the Ar+ + Ar+ coincidence channel is plotted as a function of the pump–probe delay td.
Over the entire range, delay-independent contributions at 3.8 eV and 5.3 eV are present. They stem from the absorption of two photons within one pulse, the pump or the probe. The contribution at 3.8 eV is assigned to the direct fragmentation at the equilibrium internuclear distance Req = 7.18 a.u. by absorbing two photons. As depicted by the curves (PECs) in Fig. 16, this happens sequentially via the intermediate Ar+(3p−1)–Ar state within one FEL pulse. The contribution at 5.3 eV is induced by an interatomic Coulombic decay (ICD) of a one-site ionized and excited Ar+(3p−2nl)–Ar state (Miteva et al., 2014) (cf. Fig. 16). The decay onto the repulsive Ar+(3p−1)–Ar+(3p−1) state takes place at an internuclear distance R < Req, which according to equation (3) results in a higher KER compared with the fragmentation at Req.
Besides the delay-independent contributions, a pump–probe signal is visible in Fig. 15. It starts at time zero at 3.8 eV and asymptotically reaches KERs of ∼1.0 eV for large delays. This signal is attributed to dissociative The pump pulse initiates the dissociation of the dimer into a charged and a neutral fragment (cf. Fig. 16),
Then, the delayed probe pulse interrupts the dissociation at td by ionizing to a doubly charged state (cf. Fig. 16),
The overall KER is given by the +(3p−1)–Ar and the final Ar+(3p−1)–Ar+(3p−1) PEC,
accumulated on the initial ArFor large delays |td| → ∞, Efinal[R(|td| → ∞)] = Efinal(R → ∞) and no KER is accumulated on the final Ar+(3p−1)–Ar+(3p−1) curve. Thus, the asymptotic KER of ∼1.0 eV of Ar+ + Ar+ ions is a signature of the Ar+(3p−1)–Ar precursor state. The asymptotic limit is reached at large delays |td| ≥ 2 ps, which corresponds to a slow dissociation of the dimer. The visibility of the signal over at least ±2 ps confirms the pump–probe capability over a large delay range and implies that the setup allows long-lasting dynamics to be traced.
The results presented in Sections 5.4 and 5.5 demonstrate that the in-line XUV split-delay and focusing optics opens up new opportunities for time-resolved electron–ion coincidence spectroscopy at FLASH2.
6. Future upgrades
An IR pump–probe laser is the next upgrade to the FLASH2 facility (FLASH2, 2018). It is also connected to the REMI endstation. The 800 nm laser system is OPCPA based and in the final stage will deliver pulses of sub-20 fs duration in burst-mode (10 Hz bursts with an intra-burst repetition rate of 50 kHz initially). The individual pulses are foreseen to have energies of up to 0.5 mJ. The timing jitter between FEL and IR pulses is initially <50 fs (RMS). With tight focusing, peak IR intensities of >1015 W cm−2 should be attainable. First experiments at the REMI endstation using the IR pump–probe laser were performed in the end of 2018. The incoupling mirror for the IR laser is installed in the last section of the REMI beamline (colored light-red in Fig. 9). A two-inch silver-coated plane mirror is mounted on a precision rotational feed-through, which is installed on a triaxial xyz-manipulator. To overlap the FEL and the IR beam co-linearly, the IR beam is deflected by 90°. The IR incoupling mirror has a hole of 4 mm diameter for the focused FEL beam to pass through. The IR laser is focused outside of the vacuum by a lens with a focal length of 40 cm. The differential pumping tube between IR incoupling and REMI interaction chamber (4th tube in Fig. 9) has an inner diameter of 22 mm. Thus, an IR beam of ≤35 mm diameter at the position of the lens can pass through the tube without clipping.
In the near future, in cooperation with DESY and the Leibniz University of Hanover, a high harmonic generation (HHG) source will also be integrated into the REMI beamline. This will further extend the portfolio of available radiation sources and allow for two-color VUV–XUV pump–probe spectroscopy.
Furthermore, the in-line geometry of the XUV focusing optics leaves room to re-use the FEL beam in a downstream experiment taking out the photon dump (cf. Section 4.3). For example, a grating spectrometer operating on a shot-to-shot level could be useful to correlate the REMI data to the spectra of individual FEL pulses.
The next upgrade of the REMI apparatus itself will include a modular jet system. It will be mounted on rails and thus enables to easily switch between different sample injection systems.
7. Summary
In this contribution, the reaction microscope (REMI) endstation at beamline FL26 of the free-electron laser FLASH2 has been presented. The instrument is dedicated to time-resolved AMO-physics experiments on small quantum systems like atoms, molecules and small clusters by exploiting multi-particle coincidence spectroscopy. The sample injection, the design of the spectrometer, the functionality of the time- and position-sensitive detectors, the vacuum requirements and the data acquisition of the REMI were introduced. The design and the key parts of an in-line XUV split-delay and focusing optics were presented. The optics is based on grazing-incidence mirrors. With this the fast wavelength tunability of the FLASH2 variable-gap undulators can be efficiently exploited in XUV–XUV pump–probe experiments. A dedicated beamline section allows the FEL beam to be monitored and to be aligned before it enters the mirror chamber and the REMI. The beamline also serves as a differential pumping section to maintain UHV conditions of ≤10−11 mbar in the REMI interaction chamber. In the design of the beamline, special emphasis has been put on stray-light suppression, which is essential to perform multi-particle coincidence experiments at an FEL. Commissioning results demonstrate in particular the working capability of the in-line XUV split-delay and focusing optics. The endstation will be connected to the FLASH2 pump–probe laser system, which will enable XUV–IR pump–probe experiments in the near future. Further upgrades will contain an HHG source and a modular jet system.
Footnotes
1This article will form part of a virtual special issue on X-ray free-electron lasers.
‡Current address: Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
2The core part of the program has been gratefully adopted from J. P. Müller from the TU Berlin used for the KB optics at the CAMP endstation at FLASH1.
Acknowledgements
The authors thank the entire FLASH team including the accelerator, photon diagnostics and beamline groups. We are particularly grateful to C. Kaiser from the MPIK Heidelberg who helped in setting up the endstation. We especially acknowledge M. Brachmanski from FLASH for his support during the setup phase. Thanks also to B. Keitel, E. Plönjes-Palm, T. Wodzinski and M. Ruiz Lopez who helped with operating the wavefront sensor.
Funding information
Funding for this research was provided by: Volkswagen Foundation (a Peter Paul Ewald Fellowship scholarship to KS).
References
Ackermann, W., Asova, G., Ayvazyan, V., Azima, A., Baboi, N., Bähr, J., Balandin, V., Beutner, B., Brandt, A., Bolzmann, A., Brinkmann, R., Brovko, O. I., Castellano, M., Castro, P., Catani, L., Chiadroni, E., Choroba, S., Cianchi, A., Costello, J. T., Cubaynes, D., Dardis, J., Decking, W., Delsim-Hashemi, H., Delserieys, A., Di Pirro, G., Dohlus, M., Düsterer, S., Eckhardt, A., Edwards, H. T., Faatz, B., Feldhaus, J., Flöttmann, K., Frisch, J., Fröhlich, L., Garvey, T., Gensch, U., Gerth, Ch., Görler, M., Golubeva, N., Grabosch, H., Grecki, M., Grimm, O., Hacker, K., Hahn, U., Han, J. H., Honkavaara, K., Hott, T., Hüning, M., Ivanisenko, Y., Jaeschke, E., Jalmuzna, W., Jezynski, T., Kammering, R., Katalev, V., Kavanagh, K., Kennedy, E. T., Khodyachykh, S., Klose, K., Kocharyan, V., Körfer, M., Kollewe, M., Koprek, W., Korepanov, S., Kostin, D., Krassilnikov, M., Kube, G., Kuhlmann, M., Lewis, C. L. S., Lilje, L., Limberg, T., Lipka, D., Löhl, F., Luna, H., Luong, M., Martins, M., Meyer, M., Michelato, P., Miltchev, V., Möller, W. D., Monaco, L., Müller, W. F. O., Napieralski, O., Napoly, O., Nicolosi, P., Nölle, D., Nuñez, T., Oppelt, A., Pagani, C., Paparella, R., Pchalek, N., Pedregosa-Gutierrez, J., Petersen, B., Petrosyan, B., Petrosyan, G., Petrosyan, L., Pflüger, J., Plönjes, E., Poletto, L., Pozniak, K., Prat, E., Proch, D., Pucyk, P., Radcliffe, P., Redlin, H., Rehlich, K., Richter, M., Roehrs, M., Roensch, J., Romaniuk, R., Ross, M., Rossbach, J., Rybnikov, V., Sachwitz, M., Saldin, E. L., Sandner, W., Schlarb, H., Schmidt, B., Schmitz, M., Schmüser, P., Schneider, J. R., Schneidmiller, E. A., Schnepp, S., Schreiber, S., Seidel, M., Sertore, D., Shabunov, A. V., Simon, C., Simrock, S., Sombrowski, E., Sorokin, A. A., Spanknebel, P., Spesyvtsev, R., Staykov, L., Steffen, B., Stephan, F., Stulle, F., Thom, H., Tiedtke, K., Tischer, M., Toleikis, S., Treusch, R., Trines, D., Tsakov, I., Vogel, E., Weiland, T., Weise, H., Wellhöfer, M., Wendt, M., Will, I., Winter, A., Wittenburg, K., Wurth, W., Yeates, P., Yurkov, M. V., Zagorodnov, I. & Zapfe, K. (2007). Nat. Photon. 1, 336–342. Web of Science CrossRef Google Scholar
Benvenuti, C., Chiggiato, P., Pinto, P. C., Santana, A. E., Hedley, T., Mongelluzzo, A., Ruzinov, V. & Wevers, I. (1999). Vacuum, 53, 219–225. Web of Science CrossRef CAS Google Scholar
Bittner, L., Maschinenphysik, D., Feldhaus, J., Hahn, U., Hesse, M., Jastrow, U., Kocharyan, V., Radcliffe, P., Saldin, E., Schneidmiller, E., Tiedtke, K., Timmann, B., Treusch, R., Bargen, N., Yurkov, M., Brovko, O., Kharlamov, D., Lokhmatov, V., Matyushevskiy, E. & Syresin, E. (2007). Proceedings of the 29th International Free-Electron Laser Conference (FEL2007), 26–31 August 2007, Novosibirsk, Russia. Google Scholar
Braune, M., Brenner, G., Dziarzhytski, S., Juranić, P., Sorokin, A. & Tiedtke, K. (2016). J. Synchrotron Rad. 23, 10–20. Web of Science CrossRef CAS IUCr Journals Google Scholar
Callegari, C., Prince, K. C. & Ueda, K. (2016). Synchrotron Radiat. News, 29(3), 21–25. CrossRef Google Scholar
CERN (2018). ROOT, https://root.cern.ch/. Last request: 22/12/2018. Google Scholar
Dörner, R., Mergel, V., Jagutzki, O., Spielberger, L., Ullrich, J., Moshammer, R. & Schmidt-Böcking, H. (2000). Phys. Rep. 330, 95–192. Google Scholar
Erk, B., Müller, J. P., Bomme, C., Boll, R., Brenner, G., Chapman, H. N., Correa, J., Düsterer, S., Dziarzhytski, S., Eisebitt, S., Graafsma, H., Grunewald, S., Gumprecht, L., Hartmann, R., Hauser, G., Keitel, B., von Korff Schmising, C., Kuhlmann, M., Manschwetus, B., Mercadier, L., Müller, E., Passow, C., Plönjes, E., Ramm, D., Rompotis, D., Rudenko, A., Rupp, D., Sauppe, M., Siewert, F., Schlosser, D., Strüder, L., Swiderski, A., Techert, S., Tiedtke, K., Tilp, T., Treusch, R., Schlichting, I., Ullrich, J., Moshammer, R., Möller, T. & Rolles, D. (2018). J. Synchrotron Rad. 25, 1529–1540. Web of Science CrossRef CAS IUCr Journals Google Scholar
Faatz, B., Plönjes, E., Ackermann, S., Agababyan, A., Asgekar, V., Ayvazyan, V., Baark, S., Baboi, N., Balandin, V., Bargen, N., Bican, Y., Bilani, O., Bödewadt, J., Böhnert, M., Böspflug, R., Bonfigt, S., Bolz, H., Borges, F., Borkenhagen, O., Brachmanski, M., Braune, M., Brinkmann, A., Brovko, O., Bruns, T., Castro, P., Chen, J., Czwalinna, M. K., Damker, H., Decking, W., Degenhardt, M., Delfs, A., Delfs, T., Deng, H., Dressel, M., Duhme, H., Düsterer, S., Eckoldt, H., Eislage, A., Felber, M., Feldhaus, J., Gessler, P., Gibau, M., Golubeva, N., Golz, T., Gonschior, J., Grebentsov, A., Grecki, M., Grün, C., Grunewald, S., Hacker, K., Hänisch, L., Hage, A., Hans, T., Hass, E., Hauberg, A., Hensler, O., Hesse, M., Heuck, K., Hidvegi, A., Holz, M., Honkavaara, K., Höppner, H., Ignatenko, A., Jäger, J., Jastrow, U., Kammering, R., Karstensen, S., Kaukher, A., Kay, H., Keil, B., Klose, K., Kocharyan, V., Köpke, M., Körfer, M., Kook, W., Krause, B., Krebs, O., Kreis, S., Krivan, F., Kuhlmann, J., Kuhlmann, M., Kube, G., Laarmann, T., Lechner, C., Lederer, S., Leuschner, A., Liebertz, D., Liebing, J., Liedtke, A., Lilje, L., Limberg, T., Lipka, D., Liu, B., Lorbeer, B., Ludwig, K., Mahn, H., Marinkovic, G., Martens, C., Marutzky, F., Maslocv, M., Meissner, D., Mildner, N., Miltchev, V., Molnar, S., Mross, D., Müller, F., Neumann, R., Neumann, P., Nölle, D., Obier, F., Pelzer, M., Peters, H., Petersen, K., Petrosyan, A., Petrosyan, G., Petrosyan, L., Petrosyan, V., Petrov, A., Pfeiffer, S., Piotrowski, A., Pisarov, Z., Plath, T., Pototzki, P., Prandolini, M. J., Prenting, J., Priebe, G., Racky, B., Ramm, T., Rehlich, K., Riedel, R., Roggli, M., Röhling, M., Rönsch-Schulenburg, J., Rossbach, J., Rybnikov, V., Schäfer, J., Schaffran, J., Schlarb, H., Schlesselmann, G., Schlösser, M., Schmid, P., Schmidt, C., Schmidt-Föhre, F., Schmitz, M., Schneidmiller, E., Schöps, A., Scholz, M., Schreiber, S., Schütt, K., Schütz, U., Schulte-Schrepping, H., Schulz, M., Shabunov, A., Smirnov, P., Sombrowski, E., Sorokin, A., Sparr, B., Spengler, J., Staack, M., Stadler, M., Stechmann, C., Steffen, B., Stojanovic, N., Sychev, V., Syresin, E., Tanikawa, T., Tavella, F., Tesch, N., Tiedtke, K., Tischer, M., Treusch, R., Tripathi, S., Vagin, P., Vetrov, P., Vilcins, S., Vogt, M., Wagner, A. Z., Wamsat, T., Weddig, H., Weichert, G., Weigelt, H., Wentowski, N., Wiebers, C., Wilksen, T., Willner, A., Wittenburg, K., Wohlenberg, T., Wortmann, J., Wurth, W., Yurkov, M., Zagorodnov, I. & Zemella, J. (2016). New J. Phys. 18, 062002. Web of Science CrossRef Google Scholar
Fechner, L. (2014). High-Resolution Experiments on Strong-Field Ionization of Atoms and Molecules. Springer International Publishing. Google Scholar
Feldhaus, J., Krikunova, M., Meyer, M., Möller, T., Moshammer, R., Rudenko, A., Tschentscher, T. & Ullrich, J. (2013). J. Phys. B At. Mol. Opt. Phys. 46, 164002. Web of Science CrossRef Google Scholar
FLASH2 (2018). FLASH2 pump–probe laser system, https://photon-science.desy.de/facilities/flash/beamlines/optical_laser_systems/index_eng.html. Last request: 12/04/2018. Google Scholar
Fritzsche, S., Grum-Grzhimailo, A. N., Gryzlova, E. V. & Kabachnik, N. M. (2008). J. Phys. B At. Mol. Opt. Phys. 41, 165601. Web of Science CrossRef Google Scholar
Gallagher, J. W., Brion, C. E., Samson, J. A. R. & Langhoff, P. W. (1988). J. Phys. Chem. Ref. Data, 17, 9–153. CrossRef CAS Web of Science Google Scholar
Gerken, N., Klumpp, S., Sorokin, A. A., Tiedtke, K., Richter, M., Bürk, V., Mertens, K., Juranić, P. & Martins, M. (2014). Phys. Rev. Lett. 112, 213002. Web of Science CrossRef Google Scholar
Grum-Grzhimailo, A. N., Gryzlova, E. V., Strakhova, S. I., Kabachnik, N. M. & Fritzsche, S. (2009). J. Phys. Conf. Ser. 194, 012004. Google Scholar
GSI (2018). Go4, https://go4.gsi.de/. Last request: 22/12/2018. Google Scholar
Henke, B. L., Gullikson, E. M. & Davis, J. C. (1993). At. Data Nucl. Data Tables, 54, 181–342. CrossRef CAS Web of Science Google Scholar
Hikosaka, Y., Fushitani, M., Matsuda, A., Tseng, C.-M., Hishikawa, A., Shigemasa, E., Nagasono, M., Tono, K., Togashi, T., Ohashi, H., Kimura, H., Senba, Y., Yabashi, M. & Ishikawa, T. (2010). Phys. Rev. Lett. 105, 133001. Web of Science CrossRef PubMed Google Scholar
Hunstig, M. (2017). Actuators, 6, 7. Web of Science CrossRef Google Scholar
Jagutzki, O., Cerezo, A., Czasch, A., Dörner, R., Hattas, M., Huang, M., Mergel, V., Spillmann, U., Ullmann-Pfleger, K., Weber, T., Schmidt-Böcking, H. & Smith, G. (2002a). IEEE Trans. Nucl. Sci. 49, 2477–2483. Web of Science CrossRef Google Scholar
Jagutzki, O., Mergel, V., Ullmann-Pfleger, K., Spielberger, L., Spillmann, U., Dörner, R. & Schmidt-Böcking, H. (2002b). Nucl. Instrum. Methods Phys. Res. A, 477, 244–249. Web of Science CrossRef CAS Google Scholar
Jiang, Y. H., Rudenko, A., Herrwerth, O., Foucar, L., Kurka, M., Kühnel, K. U., Lezius, M., Kling, M. F., van Tilborg, J., Belkacem, A., Ueda, K., Düsterer, S., Treusch, R., Schröter, C. D., Moshammer, R. & Ullrich, J. (2010a). Phys. Rev. Lett. 105, 263002. Web of Science CrossRef PubMed Google Scholar
Jiang, Y. H., Rudenko, A., Pérez-Torres, J., Herrwerth, O., Foucar, L., Kurka, M., Kühnel, K. U., Toppin, M., Plésiat, E., Morales, F., Martín, F., Lezius, M., Kling, M. F., Jahnke, T., Dörner, R., Sanz-Vicario, J. L., van Tilborg, J., Belkacem, A., Schulz, M., Ueda, K., Zouros, T., Düsterer, S., Treusch, R., Schröter, C. D., Moshammer, R. & Ullrich, J. (2010b). Phys. Rev. A, 81, 051402. Web of Science CrossRef Google Scholar
Jousten, K. (2010). Wutz Handbuch Vakuumtechnik. Praxis, 10th ed. Wiesbaden: Vieweg + Teubner. Google Scholar
Keitel, B., Plönjes, E., Kreis, S., Kuhlmann, M., Tiedtke, K., Mey, T., Schäfer, B. & Mann, K. (2016). J. Synchrotron Rad. 23, 43–49. Web of Science CrossRef CAS IUCr Journals Google Scholar
Kheifets, A. S. (2007). J. Phys. B At. Mol. Opt. Phys. 40, F313–F318. Web of Science CrossRef CAS Google Scholar
Krikunova, M., Adolph, M., Gorkhover, T., Rupp, D., Schorb, S., Bostedt, C., Roling, S., Siemer, B., Mitzner, R., Zacharias, H. & Möller, T. (2012). J. Phys. B At. Mol. Opt. Phys. 45, 105101. Web of Science CrossRef Google Scholar
Kurka, M., Feist, J., Horner, D. A., Rudenko, A., Jiang, Y. H., Kühnel, K. U., Foucar, L., Rescigno, T. N., McCurdy, C. W., Pazourek, R., Nagele, S., Schulz, M., Herrwerth, O., Lezius, M., Kling, M. F., Schöffler, M., Belkacem, A., Düsterer, S., Treusch, R., Schneider, B. I., Collins, L. A., Burgdörfer, J., Schröter, C. D., Moshammer, R. & Ullrich, J. (2010). New J. Phys. 12, 073035. Web of Science CrossRef Google Scholar
Kurka, M., Rudenko, A., Foucar, L., Kühnel, K. U., Jiang, Y. H., Ergler, T., Havermeier, T., Smolarski, M., Schössler, S., Cole, K., Schöffler, M., Dörner, R., Gensch, M., Düsterer, S., Treusch, R., Fritzsche, S., Grum-Grzhimailo, A. N., Gryzlova, E. V., Kabachnik, N. M., Schröter, C. D., Moshammer, R. & Ullrich, J. (2009). J. Phys. B At. Mol. Opt. Phys. 42, 141002. Web of Science CrossRef Google Scholar
Lampton, M., Siegmund, O. & Raffanti, R. (1987). Rev. Sci. Instrum. 58, 2298–2305. CrossRef CAS Web of Science Google Scholar
Magrakvelidze, M., Herrwerth, O., Jiang, Y. H., Rudenko, A., Kurka, M., Foucar, L., Kühnel, K. U., Kübel, M., Johnson, N. G., Schröter, C. D., Düsterer, S., Treusch, R., Lezius, M., Ben-Itzhak, I., Moshammer, R., Ullrich, J., Kling, M. F. & Thumm, U. (2012). Phys. Rev. A, 86, 013415. Web of Science CrossRef Google Scholar
Meister, S. (2016). Master thesis, University of Heidelberg, Germany. Google Scholar
Miteva, T., Chiang, Y.-C., Kolorenč, P., Kuleff, A., Gokhberg, K. & Cederbaum, L. S. (2014). J. Chem. Phys. 141, 064307. Web of Science CrossRef PubMed Google Scholar
Moshammer, R., Jiang, Y. H., Foucar, L., Rudenko, A., Ergler, T., Schröter, C. D., Lüdemann, S., Zrost, K., Fischer, D., Titze, J., Jahnke, T., Schöffler, M., Weber, T., Dörner, R., Zouros, T., Dorn, A., Ferger, T., Kühnel, K. U., Düsterer, S., Treusch, R., Radcliffe, P., Plönjes, E. & Ullrich, J. (2007). Phys. Rev. Lett. 98, 203001. Web of Science CrossRef PubMed Google Scholar
Moshammer, R. & Schnorr, K. (2014). Molecular Physics and Gas-Phase Chemistry with Free-Electron Lasers, pp. 1–29. Cham: Springer International Publishing. Google Scholar
Moshammer, R., Unverzagt, M., Schmitt, W., Ullrich, J. & Schmidt-Böcking, H. (1996). Nucl. Instrum. Methods Phys. Res. B, 108, 425–445. CrossRef CAS Web of Science Google Scholar
Noll, T., Holldack, K., Reichardt, G., Schwarzkopf, O. & Zeschke, T. (2009). Precis. Eng. 33, 291–304. Web of Science CrossRef Google Scholar
Plönjes, E., Faatz, B., Kuhlmann, M. & Treusch, R. (2016). AIP Conf. Proc. 1741, 020008. Google Scholar
Pontius, N., Beye, M., Trabant, C., Mitzner, R., Sorgenfrei, F., Kachel, T., Wöstmann, M., Roling, S., Zacharias, H., Ivanov, R., Treusch, R., Buchholz, M., Metcalf, P., Schüssler-Langeheine, C. & Föhlisch, A. (2018). Struct. Dyn. 5, 054501. Web of Science CrossRef PubMed Google Scholar
Richter, M., Amusia, M. Y., Bobashev, S. V., Feigl, T., Juranić, P. N., Martins, M., Sorokin, A. A. & Tiedtke, K. (2009). Phys. Rev. Lett. 102, 163002. Web of Science CrossRef PubMed Google Scholar
Rudenko, A., Jiang, Y. H., Kurka, M., Kühnel, K. U., Foucar, L., Herrwerth, O., Lezius, M., Kling, M. F., Schröter, C. D., Moshammer, R. & Ullrich, J. (2010). J. Phys. B At. Mol. Opt. Phys. 43, 194004. Web of Science CrossRef Google Scholar
Sauppe, M., Rompotis, D., Erk, B., Bari, S., Bischoff, T., Boll, R., Bomme, C., Bostedt, C., Dörner, S., Düsterer, S., Feigl, T., Flückiger, L., Gorkhover, T., Kolatzki, K., Langbehn, B., Monserud, N., Müller, E., Müller, J. P., Passow, C., Ramm, D., Rolles, D., Schubert, K., Schwob, L., Senfftleben, B., Treusch, R., Ulmer, A., Weigelt, H., Zimbalski, J., Zimmermann, J., Möller, T. & Rupp, D. (2018). J. Synchrotron Rad. 25, 1517–1528. Web of Science CrossRef CAS IUCr Journals Google Scholar
Schmid, G. (2018). PhD thesis, University of Heidelberg, Germany. Google Scholar
Schnorr, K. (2014). PhD thesis, University of Heidelberg, Germany. Google Scholar
Schnorr, K., Senftleben, A., Kurka, M., Rudenko, A., Foucar, L., Schmid, G., Broska, A., Pfeifer, T., Meyer, K., Anielski, D., Boll, R., Rolles, D., Kübel, M., Kling, M. F., Jiang, Y. H., Mondal, S., Tachibana, T., Ueda, K., Marchenko, T., Simon, M., Brenner, G., Treusch, R., Scheit, S., Averbukh, V., Ullrich, J., Schröter, C. D. & Moshammer, R. (2013). Phys. Rev. Lett. 111, 093402. Web of Science CrossRef PubMed Google Scholar
Schnorr, K., Senftleben, A., Kurka, M., Rudenko, A., Schmid, G., Pfeifer, T., Meyer, K., Kübel, M., Kling, M. F., Jiang, Y. H., Treusch, R., Düsterer, S., Siemer, B., Wöstmann, M., Zacharias, H., Mitzner, R., Zouros, T. J. M., Ullrich, J., Schröter, C. D. & Moshammer, R. (2014). Phys. Rev. Lett. 113, 073001. Web of Science CrossRef PubMed Google Scholar
Scoles, G. (1988). Atomic and Molecular Beam Methods: 1. Atomic and Molecular Beam Methods. Oxford University Press. Google Scholar
Sorokin, A. A., Bobashev, S. V., Feigl, T., Tiedtke, K., Wabnitz, H. & Richter, M. (2007a). Phys. Rev. Lett. 99, 213002. Web of Science CrossRef PubMed Google Scholar
Sorokin, A. A., Wellhöfer, M., Bobashev, S. V., Tiedtke, K. & Richter, M. (2007b). Phys. Rev. A, 75, 051402. Web of Science CrossRef Google Scholar
Stoychev, S. D., Kuleff, A. I., Tarantelli, F. & Cederbaum, L. S. (2008). J. Chem. Phys. 128, 014307. Web of Science CrossRef PubMed Google Scholar
Tiedtke, K., Azima, A., von Bargen, N., Bittner, L., Bonfigt, S., Düsterer, S., Faatz, B., Frühling, U., Gensch, M., Gerth, C., Guerassimova, N., Hahn, U., Hans, T., Hesse, M., Honkavaar, K., Jastrow, U., Juranic, P., Kapitzki, S., Keitel, B., Kracht, T., Kuhlmann, M., Li, W. B., Martins, M., Núñez, T., Plönjes, E., Redlin, H., Saldin, E. L., Schneidmiller, E. A., Schneider, J. R., Schreiber, S., Stojanovic, N., Tavella, F., Toleikis, S., Treusch, R., Weigelt, H., Wellhöfer, M., Wabnitz, H., Yurkov, M. V. & Feldhaus, J. (2009). New J. Phys. 11, 023029. Web of Science CrossRef Google Scholar
Ullrich, J., Moshammer, R., Dorn, A., Dörner, R., Schmidt, L. & Schmidt-Böcking, H. (2003). Rep. Prog. Phys. 66, 1463–1545. Web of Science CrossRef CAS Google Scholar
Usenko, S., Przystawik, A., Jakob, M. A., Lazzarino, L. L., Brenner, G., Toleikis, S., Haunhorst, C., Kip, D. & Laarmann, T. (2017). Nat. Commun. 8, 15626. Web of Science CrossRef PubMed Google Scholar
Wiley, W. C. & McLaren, I. H. (1955). Rev. Sci. Instrum. 26, 1150–1157. CrossRef CAS Web of Science Google Scholar
Wiza, J. (1979). Nucl. Instrum. Methods, 162, 587–601. CAS Google Scholar
Yabashi, M., Tanaka, H., Tanaka, T., Tomizawa, H., Togashi, T., Nagasono, M., Ishikawa, T., Harries, J. R., Hikosaka, Y., Hishikawa, A., Nagaya, K., Saito, N., Shigemasa, E., Yamanouchi, K. & Ueda, K. (2013). J. Phys. B At. Mol. Opt. Phys. 46, 164001. Web of Science CrossRef Google Scholar
Yeh, J. J. & Lindau, I. (1985). At. Data Nucl. Data Tables, 32, 1–155. CrossRef CAS Web of Science Google Scholar
Zewail, A. H. (1988). Science, 242, 1645–1653. CrossRef PubMed CAS Web of Science Google Scholar
Zewail, A. H. (2000). J. Phys. Chem. A, 104, 5660–5694. Web of Science CrossRef CAS Google Scholar