![[HTML version]](/e/graphics/htmlborder.gif)
![[PDF version]](/e/graphics/pdfborder.gif)
![[Article Abstract]](/e/graphics/abstractborder.gif)
![[CIF]](/e/graphics/cifborder.gif)
![[3d view]](/e/graphics/3dviewborder.gif)
![[Structure Factors]](/e/graphics/structurefactorsborder.gif)
![[Buy article online]](/logos/buy.gif)
![[Contents scheme]](bv6015contents.gif)
Acta Cryst. (2005). E61, m793-m795 [ doi:10.1107/S1600536805008378 ]
Online 31 March 2005
No syntax errors found
Alert level C PLAT042_ALERT_1_C Calc. and Rep. MoietyFormula Strings Differ .... ? PLAT062_ALERT_4_C Rescale T(min) & T(max) by ..................... 0.88 PLAT244_ALERT_4_C Low 'Solvent' Ueq as Compared to Neighbors for N5 PLAT480_ALERT_4_C Long H...A H-Bond Reported H3 .. O1 .. 2.64 Ang.
Alert level G ABSTM02_ALERT_3_G When printed, the submitted absorption T values will be replaced by the scaled T values. Since the ratio of scaled T's is identical to the ratio of reported T values, the scaling does not imply a change to the absorption corrections used in the study. Ratio of Tmax expected/reported 0.877 Tmax scaled 0.877 Tmin scaled 0.655
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 4 ALERT level C = Check and explain 1 ALERT level G = General alerts; check 1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 0 ALERT type 2 Indicator that the structure model may be wrong or deficient 1 ALERT type 3 Indicator that the structure quality may be low 3 ALERT type 4 Improvement, methodology, query or suggestion
Copyright © International Union of Crystallography
IUCr Webmaster