No syntax errors found




Alert level B PLAT213_ALERT_2_B Atom C21 has ADP max/min Ratio ............. 4.60 prolat PLAT242_ALERT_2_B Check Low Ueq as Compared to Neighbors for C20 PLAT331_ALERT_2_B Small Average Phenyl C-C Dist. C20 -C25 1.35 Ang.
Alert level C ABSTM02_ALERT_3_C The ratio of expected to reported Tmax/Tmin(RR') is < 0.90 Tmin and Tmax reported: 0.705 0.930 Tmin' and Tmax expected: 0.914 0.934 RR' = 0.774 Please check that your absorption correction is appropriate. SHFSU01_ALERT_2_C The absolute value of parameter shift to su ratio > 0.05 Absolute value of the parameter shift to su ratio given 0.087 Additional refinement cycles may be required. PLAT061_ALERT_3_C Tmax/Tmin Range Test RR' too Large ............. 0.77 PLAT080_ALERT_2_C Maximum Shift/Error ............................ 0.09 PLAT199_ALERT_1_C Check the Reported _cell_measurement_temperature 293 K PLAT200_ALERT_1_C Check the Reported _diffrn_ambient_temperature . 293 K PLAT213_ALERT_2_C Atom C22 has ADP max/min Ratio ............. 3.40 prolat PLAT220_ALERT_2_C Large Non-Solvent C Ueq(max)/Ueq(min) ... 3.00 Ratio PLAT230_ALERT_2_C Hirshfeld Test Diff for C28 - C29 .. 5.54 su PLAT230_ALERT_2_C Hirshfeld Test Diff for C28 - C33 .. 5.22 su PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for O3 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for C21 PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for C30 PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for C28 PLAT331_ALERT_2_C Small Average Phenyl C-C Dist. C28 -C33 1.36 Ang. PLAT340_ALERT_3_C Low Bond Precision on C-C bonds (x 1000) Ang ... 5
0 ALERT level A = In general: serious problem 3 ALERT level B = Potentially serious problem 16 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 2 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 14 ALERT type 2 Indicator that the structure model may be wrong or deficient 3 ALERT type 3 Indicator that the structure quality may be low 0 ALERT type 4 Improvement, methodology, query or suggestion