Acta Cryst. (2006). E62, o2324-o2326 [ doi:10.1107/S160053680601720X ]
Thiaminium dipicrate
Online 12 May 2006
Key indicators
- Single-crystal X-ray study
- T = 293 K
- Mean
(C-C) = 0.007 Å
- Disorder in main residue
- R factor = 0.067
- wR factor = 0.240
- Data-to-parameter ratio = 10.2
checkCIF/PLATON results
No syntax errors found
Alert level A
PLAT242_ALERT_2_A Check Low Ueq as Compared to Neighbors for C141
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT242_ALERT_2_A Check Low Ueq as Compared to Neighbors for C142
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
Alert level B
PLAT201_ALERT_2_B Isotropic non-H Atoms in Main Residue(s) ....... 2
PLAT241_ALERT_2_B Check High Ueq as Compared to Neighbors for S111
PLAT241_ALERT_2_B Check High Ueq as Compared to Neighbors for C7
PLAT241_ALERT_2_B Check High Ueq as Compared to Neighbors for C131
PLAT242_ALERT_2_B Check Low Ueq as Compared to Neighbors for C101
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT242_ALERT_2_B Check Low Ueq as Compared to Neighbors for N13
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT430_ALERT_2_B Short Inter D...A Contact O14 .. O161 .. 2.83 Ang.
PLAT430_ALERT_2_B Short Inter D...A Contact O15 .. N82 .. 2.86 Ang.
Alert level C
PLAT026_ALERT_3_C Ratio Observed / Unique Reflections too Low .... 45 Perc.
PLAT042_ALERT_1_C Calc. and Rep. MoietyFormula Strings Differ .... ?
PLAT062_ALERT_4_C Rescale T(min) & T(max) by ..................... 1.01
PLAT199_ALERT_1_C Check the Reported _cell_measurement_temperature 293 K
PLAT200_ALERT_1_C Check the Reported _diffrn_ambient_temperature . 293 K
PLAT213_ALERT_2_C Atom O151 has ADP max/min Ratio ............. 3.20 prolat
PLAT213_ALERT_2_C Atom O152 has ADP max/min Ratio ............. 3.20 prolat
PLAT213_ALERT_2_C Atom C192 has ADP max/min Ratio ............. 3.80 prolat
PLAT220_ALERT_2_C Large Non-Solvent O Ueq(max)/Ueq(min) ... 2.50 Ratio
PLAT222_ALERT_3_C Large Non-Solvent H Ueq(max)/Ueq(min) ... 3.28 Ratio
PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for S112
PLAT241_ALERT_2_C Check High Ueq as Compared to Neighbors for C132
PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for C91
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for N82
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for C92
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for N11
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for N12
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for N21
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for N22
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT242_ALERT_2_C Check Low Ueq as Compared to Neighbors for N23
| Author Response: As the end terminal oxygen, it has large high Ueq
value. As well it is in disordered state. So, the comparision of this Carbon
with that atom can be overlooked.
|
PLAT250_ALERT_2_C Large U3/U1 Ratio for Average U(i,j) Tensor .... 3.00
PLAT301_ALERT_3_C Main Residue Disorder ......................... 18.00 Perc.
PLAT340_ALERT_3_C Low Bond Precision on C-C bonds (x 1000) Ang ... 7
PLAT414_ALERT_2_C Short Intra D-H..H-X H4B .. H7B .. 1.91 Ang.
PLAT432_ALERT_2_C Short Inter X...Y Contact O21 .. C6 .. 2.99 Ang.
PLAT432_ALERT_2_C Short Inter X...Y Contact O24 .. C13 .. 2.94 Ang.
PLAT480_ALERT_4_C Long H...A H-Bond Reported H6 .. O21 .. 2.62 Ang.
PLAT480_ALERT_4_C Long H...A H-Bond Reported H12A .. O12 .. 2.65 Ang.
2 ALERT level A = In general: serious problem
8 ALERT level B = Potentially serious problem
28 ALERT level C = Check and explain
0 ALERT level G = General alerts; check
3 ALERT type 1 CIF construction/syntax error, inconsistent or missing data
28 ALERT type 2 Indicator that the structure model may be wrong or deficient
4 ALERT type 3 Indicator that the structure quality may be low
3 ALERT type 4 Improvement, methodology, query or suggestion