No syntax errors found
Alert level C CRYSC01_ALERT_1_C The word below has not been recognised as a standard identifier. colouless CRYSC01_ALERT_1_C No recognised colour has been given for crystal colour. PLAT062_ALERT_4_C Rescale T(min) & T(max) by ..................... 0.77 PLAT153_ALERT_1_C The su's on the Cell Axes are Equal (x 100000) . 200 Ang.
Alert level G ABSTM02_ALERT_3_G When printed, the submitted absorption T values will be replaced by the scaled T values. Since the ratio of scaled T's is identical to the ratio of reported T values, the scaling does not imply a change to the absorption corrections used in the study. Ratio of Tmax expected/reported 0.773 Tmax scaled 0.500 Tmin scaled 0.182 PLAT199_ALERT_1_G Check the Reported _cell_measurement_temperature 293 K PLAT200_ALERT_1_G Check the Reported _diffrn_ambient_temperature . 293 K
0 ALERT level A = In general: serious problem 0 ALERT level B = Potentially serious problem 4 ALERT level C = Check and explain 3 ALERT level G = General alerts; check 5 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 0 ALERT type 2 Indicator that the structure model may be wrong or deficient 1 ALERT type 3 Indicator that the structure quality may be low 1 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check