Figure 4
Plots of θ-corrected X-ray diffraction results before (11 min) and after hydrothermal reaction. Homogenization significantly increases the intensity of the quartz 101 reflection, indicating some surface sensitivity of the in situ measurements. (See Fig. S3 for the full range) |